Abstract:
RATIONALE AND OBJECTIVES:To develop a computer-assisted analysis of complex joint motion based on standard fluoroscopic sequences. MATERIALS AND METHODS:Fluoroscopic sequences of 10 normal shoulders and 20 patients after total shoulder arthroplasty were recorded during abduction and adduction. The analysis of the shoulder motion was based on automated tracking of selected components (models) of the shoulder joint. After processing the digitized images with an edge-detection procedure, visible edges were defined as base models. These models were tracked frame by frame. Several automated postprocessing evaluation procedures were developed and tested. RESULTS:The amounts of rotation and translation of the glenohumeral joint can be quantified and related. The mean translation parallel to the glenoid in the normal shoulder joints was 2.8 mm and 1.9 mm in joints after shoulder arthroplasty. The mean translation perpendicular to the glenoid was 0.9 mm and 0.8 mm, respectively. In complex motion patterns (ie, combined glenohumeral and thoracoscapular motion), electronic stabilization of an object (ie, stabilization of scapula) and, thus, separate analysis of each component. CONCLUSION:Computer assisted analysis allows automated evaluation of complex joint motion based on standard fluoroscopic sequences.
journal_name
Invest Radioljournal_title
Investigative radiologyauthors
Pfirrmann CW,Huser M,Székely G,Hodler J,Gerber Cdoi
10.1097/00004424-200202000-00004keywords:
subject
Has Abstractpub_date
2002-02-01 00:00:00pages
73-6issue
2eissn
0020-9996issn
1536-0210journal_volume
37pub_type
杂志文章abstract:OBJECTIVES:To test the feasibility of a single MR-based examination allowing for the comprehensive assessment of renal anatomy, function, and vascular status in candidates for kidney transplantation. MATERIALS AND METHODS:Twelve healthy potential kidney donors (mean age: 47 +/- 14 [standard deviation] years, 3 men and...
journal_title:Investigative radiology
pub_type: 临床试验,杂志文章
doi:10.1097/RLI.0b013e3181b35a70
更新日期:2009-11-01 00:00:00
abstract::The feasibility of control of traumatic hepatic hemorrhage by angiographic transcatheter embolization was investigated. Bleeding sites were created in the livers of each of twelve dogs, and the hepatic artery was occluded with Gelfoam. Successful control of bleeding was demonstrated by postembolization angiography in ...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-197801000-00014
更新日期:1978-01-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:Target-specific magnetic resonance (MR) contrast agents are being developed to improve the accuracy of MR imaging. The purpose of this study was to determine the mechanism of cell uptake, and modes of intracellular trafficking of a prototypical iron oxide label (RMA) used in the synthesis of so...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199510000-00006
更新日期:1995-10-01 00:00:00
abstract::Virtually all receiver operating characteristic (ROC) studies of medical imaging methods have involved data collected on a discrete confidence-rating scale, though in principle ROC studies can be conducted with either discrete or continuous scales. Continuous scales provide potential advantages in medical applications...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199202000-00016
更新日期:1992-02-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:Ultrasound can cause destruction of microbubble contrast agents used to enhance medical ultrasound imaging. This study sought to characterize the dynamics of this interaction by direct visual observation of microbubbles during insonification in vitro by a medical ultrasound imaging system. MET...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199812000-00004
更新日期:1998-12-01 00:00:00
abstract::At a given radiation dosage and field of view, five variables are under meaningful control for intravenous digital subtraction angiography (IV-DSA): concentration and quantity of contrast media injected, volume of injectate, rate of injection, and site of injection. Some controversy exists regarding the selection of a...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198401000-00007
更新日期:1984-01-01 00:00:00
abstract::Erythrocytes at various concentrations were examined with a sensitive A-mode ultrasonic scanner; simultaneous measurements were made under light microscopic control. Individual erythrocytes caused weak (about 1 dB) echoes while erythrocyte aggregates (ten to 100 cells) produced stronger echoes (up to 15 dB), grossly p...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198508000-00014
更新日期:1985-08-01 00:00:00
abstract::Magnetic resonance angiography (MRA) for application in the musculoskeletal system is progressing at a rapid pace. The clinical role of this new technique is still being developed, although a number of uses have already become well recognized, and MRA is diffusing into clinical practice. This article describes the bas...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199212002-00014
更新日期:1992-12-01 00:00:00
abstract::The authors reexamined a suspected difference in the effects of clinical information upon detection of nodules vs. more diverse lesions by directly incorporating classification specificity into detection ROC analysis. Categorical prompts, correct for specific abnormalities, led to detection superior to unprompted read...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198801000-00011
更新日期:1988-01-01 00:00:00
abstract:OBJECTIVES:The aim of this study was to develop and verify a method to obtain good temporal resolution T2-weighted 4-dimensional (4D-T2w) magnetic resonance imaging (MRI) by using motion information from T1-weighted 4D (4D-T1w) MRI, to support treatment planning in MR-guided radiotherapy. MATERIALS AND METHODS:Ten pat...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0000000000000381
更新日期:2017-10-01 00:00:00
abstract:OBJECTIVES:The aims of this study were to implement and systematically evaluate the performance of a new parameter-free segmented algorithm for analysis of diffusion imaging data using a combined intravoxel incoherent motion and diffusion kurtosis imaging (IVIM-DKI) model of spin diffusion in comparison with the simple...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0000000000000223
更新日期:2016-03-01 00:00:00
abstract:OBJECTIVES:Thermal dose in tumor tissue is a key factor for regional hyperthermia (HT) combined with chemotherapy and for drug delivery using thermosensitive liposomes (TSL). It influences therapy outcome, affects the accumulation of liposomes, and triggers the content release from TSL in the target tissue. For the dev...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0b013e31818768cd
更新日期:2008-12-01 00:00:00
abstract:OBJECTIVES:The purpose of our study was to assess the potential for radiation dose reduction in digital postinterventional digital mammograms after marker placement. MATERIALS AND METHODS:One hundred consecutive cases of marker placement (hook-wire localization or postbiopsy clip marker placement), with 200 full-field...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/01.rli.0000163743.63063.9f
更新日期:2005-06-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:The authors investigated whether the ability of human malignant melanoma cells to increase in cell number or their ability to remain viable was compromised by high-field strength static magnetic fields. Normal human fibroblasts also were studied to determine if any magnetic field-related altera...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199210000-00014
更新日期:1992-10-01 00:00:00
abstract::Effectiveness of terbutaline, a potent uterine muscle relaxant, for differentiation of temporary and anatomic interstitial fallopian tube obstruction (IFTO) at hysterosalpingography (HSG) was explored. In 43 IFTO evaluated, HSG after terbutaline showed patency in only one of 16 tubes in which IFTO was caused by spasm ...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198803000-00010
更新日期:1988-03-01 00:00:00
abstract:OBJECTIVES:The objective of this study was to evaluate the use of dielectric pads for improving high spatial resolution imaging of the inner ear at 7 T. MATERIALS AND METHODS:Two sets of dielectric pads were designed using electromagnetic simulations and implemented using a deuterated suspension of barium titanate. Th...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0000000000000026
更新日期:2014-05-01 00:00:00
abstract::We evaluated the density distribution (anterior-posterior) of the right lung in 19 acutely anesthetized supine dogs using computed transmission tomography (CTT). Eleven dogs served as controls, and eight received 0.12 cc/kg of intravenously administered oleic acid. The latter were sequentially imaged over 1 hour. Nine...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:
更新日期:1984-05-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:The capability of an indirect computed tomographic lymphography (CT-LG) using a nonionic monometric contrast medium iopamidol for visualizing breast lymphatic pathways was preliminarily tested. MATERIALS AND METHODS:In 10 female dogs, a total of 0.5 and 1 mL of undiluted iopamidol was injected...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-200302000-00002
更新日期:2003-02-01 00:00:00
abstract:RATIONAL AND OBJECTIVES:Magnetic resonance (MR) scan technique and lesion detectability were evaluated using a newly developed spinal abscess model in the New Zealand White rabbit. METHODS:To create the lesion, an epidural needle was inserted under fluoroscopic guidance in the lumbar region and advanced to penetrate t...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199804000-00008
更新日期:1998-04-01 00:00:00
abstract:OBJECTIVES:We compared the image quality and diagnostic performance of 2 fat-suppression methods for black-blood T2-weighted fast spin-echo (FSE), which are as follows: (a) short T1 inversion recovery (STIR; FSE-STIR) and (b) spectral adiabatic inversion recovery (SPAIR; FSE-SPAIR), for detection of acute myocardial in...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0b013e3182718672
更新日期:2013-01-01 00:00:00
abstract:OBJECTIVES:Comparison of intravenous Fenestra VC-enhanced computed tomography (CT) with gadopentetate dimeglumine and Ferucarbotran contrast-enhanced magnetic resonance imaging (MRI) for the in vivo imaging of hepatic ischemia/reperfusion injury (IRI) in a murine model. MATERIAL AND METHODS:After induction of hepatic ...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0b013e318155aa2e
更新日期:2008-02-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:To evaluate the role of granulocytes in reperfusion injury after liver transplantation. The authors injected radiolabeled granulocytes to determine if human liver graft outcome could be correlated with granulocyte accumulation. MATERIALS AND METHODS:Pure granulocyte suspension was prepared fro...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199603000-00003
更新日期:1996-03-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:To evaluate the short-term effects of a new nitinol stent on canine arteries. METHODS:Eighteen nitinol mesh stents were placed in abdominal aortas, common iliac arteries, and renal arteries of six dogs. Angiography was performed to evaluate the patency rates and structural changes of arteries ...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199905000-00007
更新日期:1999-05-01 00:00:00
abstract:PURPOSE:The relaxivities of 3 macrocyclic gadolinium-based contrast agents (GBCAs) were determined in human plasma and blood under standardized and clinically relevant laboratory conditions. METHODS:The T1 relaxivity, r1, was determined in human plasma at 1.5, 3, and 7 T, and in human blood at 3 T at 37°C in phantoms ...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0000000000000577
更新日期:2019-09-01 00:00:00
abstract::Attenuation correction (AC) is an essential step in the positron emission tomography (PET) data reconstruction process to provide accurate and quantitative PET images. The introduction of PET/magnetic resonance (MR) hybrid systems has raised new challenges but also possibilities regarding PET AC. While in PET/computed...
journal_title:Investigative radiology
pub_type: 杂志文章,评审
doi:10.1097/RLI.0000000000000289
更新日期:2016-10-01 00:00:00
abstract:OBJECTIVES:Contrast-enhanced ultrasound imaging is increasingly being used in the clinic for assessment of tissue vascularity. The purpose of our study was to evaluate the effect of different contrast administration parameters on the in vivo ultrasound imaging signal in tumor-bearing mice using a maximum intensity pers...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0b013e3181f9202d
更新日期:2011-03-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:The effect of varying exposure parameters on the detectability of a fracture with digital and conventional radiography were examined. METHODS:A macerated fractured skull was imaged by film-screen radiography (FSR) and digital storage phosphor radiography (DR) with various exposure values. Five...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199303000-00010
更新日期:1993-03-01 00:00:00
abstract::Four-hour delayed contrast-enhanced computed tomography (DCECT) shows promise for improved detection of focal liver lesions. No previous studies have examined the use of nonionic contrast materials for DCECT. The authors undertook a case-controlled study in monkeys to define the relative efficacies of iopamidol and di...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198910000-00010
更新日期:1989-10-01 00:00:00
abstract::The authors compared the renal toxicity of the low osmolality radiocontrast agents, iohexol and ioxaglate, and the ionic agent, iothalamate, at equivalent iodine dose, using experimental models in vitro and in vivo. In isolated perfused rat kidneys, all agents induced comparable biphasic hemodynamic changes, associate...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199104000-00008
更新日期:1991-04-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:This study was devised to develop a method of measuring the acute effects of radiocontrast media on renal function and assessing the relationship of the dose of radiocontrast media infused with the incidence of radiocontrast-induced renal failure. In addition, the drug adenosine phosphate-magne...
journal_title:Investigative radiology
pub_type: 临床试验,杂志文章,随机对照试验
doi:10.1097/00004424-199406000-00004
更新日期:1994-06-01 00:00:00