Abstract:
PURPOSE:The relaxivities of 3 macrocyclic gadolinium-based contrast agents (GBCAs) were determined in human plasma and blood under standardized and clinically relevant laboratory conditions. METHODS:The T1 relaxivity, r1, was determined in human plasma at 1.5, 3, and 7 T, and in human blood at 3 T at 37°C in phantoms containing 4 different concentrations of the macrocyclic GBCAs gadobutrol, gadoteridol, and gadoterate. An inversion recovery turbo spin echo sequence was used to generate images with several inversion times. The T1-times were obtained by fitting the signal intensities to the signal equation. r1 was obtained by a 1/y-weighted regression of the T1-rates over the concentration of the GBCAs. RESULTS:For gadobutrol, the obtained r1 [L/(mmol·s)] in human plasma at 1.5 T, 3 T, and 7 T, and in human blood at 3 T was 4.78 ± 0.12, 4.97 ± 0.59, 3.83 ± 0.24, and 3.47 ± 0.16. For gadoteridol, r1 was 3.80 ± 0.10, 3.28 ± 0.09, 3.21 ± 0.07, and 2.61 ± 0.16, and for gadoterate, 3.32 ± 0.13, 3.00 ± 0.13, 2.84 ± 0.09, and 2.72 ± 0.17. CONCLUSIONS:The relaxivity of gadobutrol is significantly higher than that of gadoteridol and gadoterate at all magnetic field strengths and in plasma as well as in blood, whereas that of gadoteridol was higher than gadoterate only in plasma at 1.5 and 7 T. This is in accordance with results from 3 previous studies obtained in different media.
journal_name
Invest Radioljournal_title
Investigative radiologyauthors
Szomolanyi P,Rohrer M,Frenzel T,Noebauer-Huhmann IM,Jost G,Endrikat J,Trattnig S,Pietsch Hdoi
10.1097/RLI.0000000000000577subject
Has Abstractpub_date
2019-09-01 00:00:00pages
559-564issue
9eissn
0020-9996issn
1536-0210journal_volume
54pub_type
杂志文章abstract:OBJECTIVE:To investigate the efficacy of true fast imaging with steady state precession (true-FISP) compared with T2-weighted fast spin echo (T2W-FSE) in monitoring changes in cyst volume and renal expansion in an ischemia reperfusion (IR) injured PKD1 knockout (IKO) mouse model. MATERIALS AND METHODS:The animal study...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0b013e3181be3501
更新日期:2010-01-01 00:00:00
abstract::At a given radiation dosage and field of view, five variables are under meaningful control for intravenous digital subtraction angiography (IV-DSA): concentration and quantity of contrast media injected, volume of injectate, rate of injection, and site of injection. Some controversy exists regarding the selection of a...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198401000-00007
更新日期:1984-01-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:To compare technical aspects and neointima formation of a new Nitinol stent and a Wallstent. METHODS:A Nitinol sten and a Wallstent were placed into the iliac arteries of 14 sheep (total of 28 stents) and followed angiographically. Seven sheep were killed after 1 month and 7 after 4.5 months. ...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199507000-00004
更新日期:1995-07-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:Density of trabecular bone structures in human heel bones was assessed by 3D magnetic resonance (MR) gradient echo imaging (GEI) with multiple echoes. Different spatial resolutions were applied to investigate the influence of the pixel size on signal characteristics in GEI and to find suitable ...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-200007000-00001
更新日期:2000-07-01 00:00:00
abstract::A high-speed computed tomography (CT) scanner was used for measuring flow in a phantom and in the common carotid arteries of six dogs. The general ability of the scanner to assess flow using contrast media boluses was tested with the phantom. The validated simple concept was then used in the animals. The carotid blood...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198712000-00008
更新日期:1987-12-01 00:00:00
abstract:OBJECTIVES:The purpose of this study was to evaluate the extent to which various commercially available gadolinium-containing contrast-enhancing (CE) agents can interfere with the measurement of calcium levels by currently used laboratory methods, suggesting (spurious) hypocalcemia or hypercalcemia with a potential ris...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/01.rli.0000170447.45577.5e
更新日期:2005-08-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:The clinically most widely used devices (Porstmann-plug, Rashkind-umbrella, Botallooccluder) have inherent specific limitations (eg, transarterial approach, residual shunts, limited retrieval). The authors assess practicability, efficacy, and tissue reaction of the new retrievable transvenous p...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199709000-00004
更新日期:1997-09-01 00:00:00
abstract::An isotopic radiation source 125I was investigated for use in soft tissue radiaography, with particular attention to possible use in mammography for mass screening. Film sensitivities, exposure rates, absorbed doeses, contrast and resolution were determined, and compared to conventional x-ray units. It was found that ...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-197509000-00007
更新日期:1975-09-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:To evaluate the changes in the microbubble population of a currently available ultrasound contrast agent (USCA) through attenuation measurements to optimize its clinical use. MATERIALS AND METHODS:The microbubble population from a galactose-based USCA (Levovist, Schering AG, Germany) was chara...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-200212000-00006
更新日期:2002-12-01 00:00:00
abstract::The authors compared the renal toxicity of the low osmolality radiocontrast agents, iohexol and ioxaglate, and the ionic agent, iothalamate, at equivalent iodine dose, using experimental models in vitro and in vivo. In isolated perfused rat kidneys, all agents induced comparable biphasic hemodynamic changes, associate...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199104000-00008
更新日期:1991-04-01 00:00:00
abstract::The association of GE Medical Systems and the AUR represents a unique collaboration between academic radiology and industry that bears important potential for elevating the quality of clinical research in radiology and developing a cadre of high-quality radiologist researchers for the future. The establishment of the ...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199305000-00001
更新日期:1993-05-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:Dynamic contrast enhanced (DCE) MR mammography (MRM) uses tumor capillary density differences for prognosis. The heterogeneous response of permeability-surface area products (PS = Kp<-->t) was examined in mammary tumors, as a function of contrast agent size, to determine what effect ROI size mi...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-200204000-00003
更新日期:2002-04-01 00:00:00
abstract::Three facets of dual-energy quantitative computed tomography are studied: (1) the algorithm for postprocessing data (the methods of Cann, Laval-Jeantet et al, Goodsitt et al [two methods], and Nickoloff et al); (2) the influence of choice of tissue-equivalent materials for calibration; and (3) the difference between c...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199008000-00003
更新日期:1990-08-01 00:00:00
abstract::Twenty-six patients who had received 43 grafts were studied before and after coronary artery vein bypass surgery. Cine ventriculograms taken in the right anterior oblique projection were analyzed and regional ejection fractions calculated. Single and multiple grafts were considered separately as were thrombosed and pa...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-197705000-00001
更新日期:1977-05-01 00:00:00
abstract:OBJECTIVE:To evaluate the effectiveness of a dual magnetic resonance-near infrared fluorescence optical imaging agent, poly(l-glutamic acid)-DTPA-Gd-NIR813, for both preoperative and intraoperative visualization and characterization of sentinel lymph nodes (SLN) in mice. MATERIALS AND METHODS:Poly(L-glutamic acid) was...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0b013e31804f5a79
更新日期:2007-08-01 00:00:00
abstract::With the ongoing development of new contrast agents, questions develop concerning the cardiac effects of these drugs. We used the perfused rat heart model to investigate the effects on cardiac and coronary function of hypertonic ionic (sodium chloride) and nonionic (glucose) solutions and conventional and low osmolali...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199003000-00009
更新日期:1990-03-01 00:00:00
abstract:BACKGROUND:Nephrogenic systemic fibrosis (NSF) has been related to the use of gadolinium-based contrast agents (GBCAs) in patients undergoing dialysis. The Prospective Fibrose Nephrogénique Systémique study, a French prospective study supported by the French drug regulatory agency (Agence Nationale de Sécurité du Médic...
journal_title:Investigative radiology
pub_type: 临床试验,杂志文章
doi:10.1097/RLI.0000000000000000
更新日期:2014-02-01 00:00:00
abstract::The results of an in vitro mixed hemadsorption (MHA) assay predicted the success of in vivo tumor localization using a radioiodinated, monoclonal, IgG1 antibody (A2) with reactivity to the human bladder carcinoma cell line RT4. In vitro, murine monoclonal antibodies A2 and G6, demonstrated reactivity to RT4 with titer...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198411000-00011
更新日期:1984-11-01 00:00:00
abstract:OBJECTIVES:The objective of this study was to prospectively compare diagnostic performance and time efficiency of a double-reading paradigm in which a first-reader computer-aided detection (CAD) is followed by a fast 2-dimensional review (DR FR-CAD) with those of a double reading with second-reader CAD (SR CAD). MATER...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0000000000000009
更新日期:2014-03-01 00:00:00
abstract::Urine samples were collected from 200 subjects undergoing intravenous pyelography. The urine histamine levels were compared with those of 132 normal control subjects, 11 subjects with systemic mastocytosis, six subjects with idiopathic anaphylaxis, and ten subjects experiencing mild anaphylactic reactions during aller...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198403000-00007
更新日期:1984-03-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:To compare the diagnostic efficacy of a standard dose of MRI contrast agent in the evaluation of primary brain tumors and metastases using a high-field 3 tesla MR unit versus a 1.5 tesla MR unit. METHODS:Sixteen patients with brain tumors were examined at both field strengths using identical a...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-200203000-00003
更新日期:2002-03-01 00:00:00
abstract::Post-angioplasty restenosis (PARS) in atherosclerotic lesions of medium and small arteries occurs in about one-third of cases in the first year following percutaneous transluminal angioplasty (PTA) (early PARS). PARS includes acute spasm, dissection with reclosure, elastic recoil, fibrocellular proliferative response,...
journal_title:Investigative radiology
pub_type: 临床试验,杂志文章,多中心研究
doi:10.1097/00004424-198811000-00002
更新日期:1988-11-01 00:00:00
abstract:OBJECTIVES:The aim of this study was to investigate the impact of impaired renal function on gadolinium (Gd) retention in various organs after Gd-based contrast agent injection. MATERIALS AND METHODS:After local animal care and review committee approval, 23 normal mice and 26 with renal failure were divided into 4 tre...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0000000000000295
更新日期:2016-10-01 00:00:00
abstract:OBJECTIVES:The objective of this study was to evaluate the frequency and characteristics of artifacts in segmentation-based attenuation correction maps (μ-maps) of positron emission tomography/magnetic resonance (PET/MR) and their impact on PET interpretation and the standardized uptake value (SUV) quantification in no...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0000000000000131
更新日期:2015-05-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:The object of this study was to determine by flow cytometry the cellular and DNA content of the washings of core biopsy samples and needles obtained during stereotactic core biopsies of clinically occult suspicious lesions. METHODS:Fourteen-gauge core multipass biopsy inner-needle saline washi...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199801000-00008
更新日期:1998-01-01 00:00:00
abstract::Magnetic resonance spectroscopy (MRS) has been most extensively applied to the study of animal models and not humans. The major reason for this extensive animal research is due to the nature of the early magnetic resonance high-field magnets, which only permitted the study of isolated cells, tissues, or small animals....
journal_title:Investigative radiology
pub_type: 杂志文章,评审
doi:10.1097/00004424-198912000-00004
更新日期:1989-12-01 00:00:00
abstract:PURPOSE:The aim of this study was to evaluate the feasibility of a prototype volume-interpolated breath-hold examination (VIBE) sequence using compressed sensing (VIBECS) for rapid multiphase arterial magnetic resonance imaging (MRI) at different temporal resolution during free-breathing in comparison with a convention...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0000000000000459
更新日期:2018-10-01 00:00:00
abstract::Breast calcification diagnosis was studied by using clinical findings and computerized image processing of a mammogram in a network of trained expert learning systems (Outcome Advisor [OA]). The system was tested with records not used for training and performance was compared with radiologist. The network was 72% accu...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199106000-00004
更新日期:1991-06-01 00:00:00
abstract:PURPOSE:The purpose of this study was to evaluate image quality of a spectral photon-counting detector (PCD) computed tomography (CT) system for evaluation of major arteries of the head and neck compared with conventional single-energy CT scans using energy-integrating detectors (EIDs). METHODS:In this institutional r...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0000000000000418
更新日期:2018-03-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:The effect of varying exposure parameters on the detectability of a fracture with digital and conventional radiography were examined. METHODS:A macerated fractured skull was imaged by film-screen radiography (FSR) and digital storage phosphor radiography (DR) with various exposure values. Five...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199303000-00010
更新日期:1993-03-01 00:00:00