Abstract:
:Erythrocytes at various concentrations were examined with a sensitive A-mode ultrasonic scanner; simultaneous measurements were made under light microscopic control. Individual erythrocytes caused weak (about 1 dB) echoes while erythrocyte aggregates (ten to 100 cells) produced stronger echoes (up to 15 dB), grossly proportional to the size of the aggregates. The latter type echoes were characteristic of higher erythrocyte concentrations (hematocrit 0.1 - 0.8). It is concluded that these echoes originate from red cell aggregates within the stagnant blood.
journal_name
Invest Radioljournal_title
Investigative radiologyauthors
Alanen A,Kormano Mdoi
10.1097/00004424-198508000-00014subject
Has Abstractpub_date
1985-08-01 00:00:00pages
521-4issue
5eissn
0020-9996issn
1536-0210journal_volume
20pub_type
杂志文章abstract::We developed a new, cineangiographic method to accurately measure the dynamic changes in the internal diameter of human arteries in vivo. Cine films were digitized at a spatial resolution of 4 microns/pixel, using a line image sensor. The vessel edges, with a Gaussian fit to a unilateral profile curve of the vessel, w...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198909000-00005
更新日期:1989-09-01 00:00:00
abstract::The potential risk of a radiologic procedure often is compared with the potential benefit of the procedure. While risk vs. benefit analysis has been useful as a step toward increased communication and understanding among radiologists, referring physicians, and the general public, it has the disadvantage that risk and ...
journal_title:Investigative radiology
pub_type: 杂志文章,评审
doi:10.1097/00004424-198901000-00005
更新日期:1989-01-01 00:00:00
abstract::The residency program at the University of Pennsylvania offers a 1-month fellowship for senior residents in medical student education. Instructional philosophy, methods, and content are discussed, observed, practiced, and evaluated. Close supervision and immediate feedback provide training particularly needed by futur...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199006000-00028
更新日期:1990-06-01 00:00:00
abstract::The effect of intravenous urography (IVU) on the excretion rate and precipitation of Tamm-Horsfall glycoprotein (THG) has been evaluated in 19 patients. Urine samples were collected immediately before the administration of contrast medium (U1) and then during the period of the excretion urogram (U2). The urinary THG: ...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198501000-00014
更新日期:1985-01-01 00:00:00
abstract:OBJECTIVES:Volumetric magnetic resonance (MR)-guided high-intensity focused ultrasound (HIFU) is a completely noninvasive image-guided thermal ablation technique. Recently, there has been growing interest in the use of MR-HIFU for noninvasive ablation of malignant tumors. Of particular interest for noninvasive ablation...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0b013e3182820257
更新日期:2013-06-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:To assess whether differences in cerebral atrophy and white matter lesions or in the presence of lactate and lipid signals can explain the observed differences in brain choline, creatine, and N-acetylaspartate levels between healthy elderly women and men. METHODS:In addition to standard magnet...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-200110000-00005
更新日期:2001-10-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:Very small dextran-coated magnetite particles were developed. These particles can be used either as immunospecific contrast agents for MRI by coupling to antibodies or as an interstitial contrast agent. METHODS:The particles were synthesized from iron chloride/dextran solutions. Size was evalu...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-200009000-00006
更新日期:2000-09-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:To compare electron beam tomography (EBT) with MR imaging (MRI) for detection of restenosis after coronary angioplasty (PTCA). METHODS:One hundred eighteen patients after PTCA were investigated. By EBT, 50 axial images were acquired (3-mm slice thickness, 120-160 mL radiographic contrast agent...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-200207000-00005
更新日期:2002-07-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:Magnetic resonance imaging (MRI) techniques seem to be very promising for 3D dosimetry studies, but long imaging acquisition time limits their use. A new fast T1 mapping protocol, easy to implement on a conventional MR imager, has been used to determine dose distributions on Fricke gels. METHO...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199903000-00014
更新日期:1999-03-01 00:00:00
abstract::Renal arteriography gives a reliable anatomic delineation of the renal vasculature. However, the presence of renal arterial disease does not determine the physiologic significance of the lesion. The intravenous infusion of saralasin, a specific angiotensin II antagonist, has been investigated as a method for identify...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-197711000-00006
更新日期:1977-11-01 00:00:00
abstract:OBJECTIVES:The aim of this study was to investigate the impact on metal artifacts and dose efficiency of using a tin filter in combination with high-energy threshold (TH) images of a photon-counting detector (PCD) computed tomography (CT) system. MATERIALS AND METHODS:A 3D-printed spine with pedicle screws was scanned...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0000000000000535
更新日期:2019-04-01 00:00:00
abstract:OBJECTIVES:Intra-arterial digital subtraction angiography (IA-DSA), an invasive procedure, is the current reference examination after percutaneous transluminal angioplasty and stenting for the detection of in-stent restenosis (ISR). In this phantom study, we evaluated flat-panel angiographic computed tomography after i...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0b013e318276db43
更新日期:2013-02-01 00:00:00
abstract:OBJECTIVES:The aim of this work was to quantitatively evaluate the pharmacokinetic pattern of Gd-EOB-DTPA in a model of isolated and perfused mouse liver by using magnetic resonance imaging (MRI) and monochromatic quantitative computed tomography (MQCT). MATERIALS AND METHODS:For MQCT, perfusions were realized with th...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/01.rli.0000174474.43772.58
更新日期:2005-09-01 00:00:00
abstract::A method is presented for selective catheterization and filming of the small internal spermatic and proper hepatic arteries in rabbits. The angiograms thus obtained afford clear delineation of the vessels and their branches and can enhance radiographic investigation of a variety of experimental disease models. ...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-197705000-00009
更新日期:1977-05-01 00:00:00
abstract:OBJECTIVES:The aim of this study was to conduct a radiopathologic evaluation of right-angled traction bronchiectasis to differentiate idiopathic pulmonary fibrosis (IPF) without honeycombing from idiopathic nonspecific interstitial pneumonia (NSIP). MATERIALS AND METHODS:The derivation cohort included 78 consecutive p...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0000000000000651
更新日期:2020-06-01 00:00:00
abstract::Recent publications of the magnetic resonance safety profile of neurostimulators, cardiac pacemakers, and other implanted devices imply that these devices are no longer a contraindication for magnetic resonance imaging. It is very promising that patients who have these implanted devices may in the future no longer be ...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/01.rli.0000185898.59140.91
更新日期:2005-12-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:As part of a general examination of the effect of blood flow patterns on the growth and risk of rupture of abdominal aortic aneurysms, the authors investigated the flow through an experimental model of a fusiform aneurysm. MATERIALS AND METHODS:Aneurysms were simulated in polyvinyl chloride tu...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199207000-00008
更新日期:1992-07-01 00:00:00
abstract:OBJECTIVE:The purpose of this study was to assess the ability of a flow-sensitive alternating inversion recovery-arterial spin labeling (FAIR-ASL) technique to track renal perfusion changes during pharmacologic and physiologic alterations in renal blood flow using microspheres as a gold standard. MATERIALS AND METHODS...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0b013e3181f5e101
更新日期:2011-02-01 00:00:00
abstract:PURPOSE:The aim of this study was to investigate if a quantitative evaluation of a magnetic resonance (MR) perfusion examination of the myocardium can achieve a comparable diagnostic accuracy as a semiquantitative evaluation. METHODS:A total of 31 patients with suspected coronary artery disease underwent MR imaging an...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0b013e31824f54cb
更新日期:2012-06-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:To evaluate the role of granulocytes in reperfusion injury after liver transplantation. The authors injected radiolabeled granulocytes to determine if human liver graft outcome could be correlated with granulocyte accumulation. MATERIALS AND METHODS:Pure granulocyte suspension was prepared fro...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199603000-00003
更新日期:1996-03-01 00:00:00
abstract::Diagnostic radiology is expanding, playing an increasingly central role in patient care, which heightens the importance of radiology teaching in undergraduate medical education. This study examined the impact of increased structure and systematic evaluation on student performance in a radiology elective. The evaluatio...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198505000-00003
更新日期:1985-05-01 00:00:00
abstract:OBJECTIVES:The objectives of this study were to assess the feasibility of magnetic resonance cholangiography (MRC) using biliary-secreted gadoxetic acid at 7 T and to compare it with T2-weighted (w) MRC at 3 T. MATERIALS AND METHODS:Ten healthy volunteers were examined on a 7-T whole-body magnetic resonance system. T2...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0000000000000004
更新日期:2014-05-01 00:00:00
abstract::Comparatively new in the roentgen evaluation of infants and children, xerography would appear to be ideal for portraying the pediatric airway. Since the radiation dose of xerography is higher than conventional radiography, its image quality is the subject of careful scrutiny in a pediatric setting here described in 23...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-197807000-00002
更新日期:1978-07-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:The authors studied the long-term distribution of gadolinium (Gd) in mice and rats after the administration of four commercially available magnetic resonance imaging contrast media. The goals were to determine any possible product dissociation in vivo and to evaluate the effects that product ex...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199506000-00008
更新日期:1995-06-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:The aim of the study was to examine the effects of azelastine on proliferation, clonogenic activity, cell-cycle, and migration of human aortic smooth-muscle cells (haSMCs) in vitro. METHODS:HaSMCs were treated for 4 days with azelastine (1 micromol/L, 25 micromol/L, 50 micromol/L). Half of the...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-200205000-00002
更新日期:2002-05-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:To establish a pig model suitable for imitating pulmonary emboli to facilitate research in the diagnosis of pulmonary embolism. METHODS:Thirteen animals were anesthetized, mechanically ventilated, and subjected to pulmonary artery catheterization initiated from the right external jugular vein....
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-200005000-00003
更新日期:2000-05-01 00:00:00
abstract:OBJECTIVE:The aim of this study was to evaluate the influence of different weighting factors on contrast enhancement, signal-to-noise ratio (SNR), and image quality in image fusion in dual energy computed tomography (DECT) angiography. MATERIAL AND METHODS:Fifteen patients underwent a CT angiography of the aorta with ...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0b013e31818c3d4b
更新日期:2009-01-01 00:00:00
abstract:PURPOSE:The purpose of this study was to evaluate image quality of a spectral photon-counting detector (PCD) computed tomography (CT) system for evaluation of major arteries of the head and neck compared with conventional single-energy CT scans using energy-integrating detectors (EIDs). METHODS:In this institutional r...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0000000000000418
更新日期:2018-03-01 00:00:00
abstract::Advances in the field of magnetic resonance (MR) as it pertains to clinical diagnostic radiology are examined in this review on the basis of publications in Investigative Radiology over the past 2 years (2005-2006). The articles published during that timeframe are discussed, organizationally wise, by anatomic region w...
journal_title:Investigative radiology
pub_type: 杂志文章,评审
doi:10.1097/01.rli.0000250461.03245.5c
更新日期:2006-12-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:The suitability of paramagnetic complexes as magnetic resonance contrast agents depends on various factors such as their relaxivity, stability, selectivity, and the inertness toward transmetallation by endogenous ions. The transmetallation of a series of 18 gadolinium complexes by the Zn2+ ion ...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-200102000-00008
更新日期:2001-02-01 00:00:00