Right-Angled Traction Bronchiectasis in Differentiating Idiopathic Pulmonary Fibrosis Without Honeycombing From Idiopathic Nonspecific Interstitial Pneumonia.

Abstract:

OBJECTIVES:The aim of this study was to conduct a radiopathologic evaluation of right-angled traction bronchiectasis to differentiate idiopathic pulmonary fibrosis (IPF) without honeycombing from idiopathic nonspecific interstitial pneumonia (NSIP). MATERIALS AND METHODS:The derivation cohort included 78 consecutive patients with idiopathic NSIP (n = 39) or IPF (n = 39) without honeycombing who underwent preoperative thin-section computed tomography scans at a single tertiary hospital. The validation cohort comprised 22 patients (14 IPF and 8 NSIP) from another institution. We assessed conventional computed tomography findings, right-angled traction bronchiectasis on minimum intensity projection (MinIP) images, and pathologic features associated with right-angled bronchiectasis. Right-angled traction bronchiectasis was defined as abrupt kinking of a single bronchus by over 90 degrees or an abrupt angle close to 180 degrees of branching bronchi in the background of fibrosis. In the validation cohort, we evaluated the proportion of correct IPF diagnoses and interobserver agreement of 4 radiologists before and after reviewing MinIP images. RESULTS:A probable usual interstitial pneumonia (UIP) pattern (odds ratio [OR], 6.948; 95% confidence interval [CI], 1.525-31.654; P = 0.012) and right-angled traction bronchiectasis (OR, 6.004; 95% CI, 1.980-18.209; P = 0.002) were independently associated with IPF. Patients with right-angled traction bronchiectasis were more likely to have extensive reticular opacity (OR, 1.149; 95% CI, 1.077-1.225; P < 0.001) and pathologically were more likely to have a broad extent of subpleural fibrosis (OR, 4.000; 95% CI, 1.457-10.987; P = 0.007) and relatively thick fibrosis (OR, 7.750; 95% CI, 2.504-23.991; P < 0.001). After reviewing MinIP images, the proportion of correct diagnoses increased from 40.9% to 54.5% to 50.0% to 77.3%. The mean kappa value for right-angled traction bronchiectasis was 0.489 ± 0.192. CONCLUSIONS:Right-angled traction bronchiectasis pathologically reflected a subpleural predominance of fibrosis and partly supported the radiologic differentiation of IPF without honeycombing from idiopathic NSIP.

journal_name

Invest Radiol

journal_title

Investigative radiology

authors

Kim H,Yoon SH,Lee HJ,Song SG,Koh J,Jeon YK,Chae KJ,Jin GY,Jin KN,Lee KY,Goo JM

doi

10.1097/RLI.0000000000000651

subject

Has Abstract

pub_date

2020-06-01 00:00:00

pages

387-395

issue

6

eissn

0020-9996

issn

1536-0210

journal_volume

55

pub_type

杂志文章
  • Identifying tumor vascular permeability heterogeneity with magnetic resonance imaging contrast agents.

    abstract:RATIONALE AND OBJECTIVES:Dynamic contrast enhanced (DCE) MR mammography (MRM) uses tumor capillary density differences for prognosis. The heterogeneous response of permeability-surface area products (PS = Kp<-->t) was examined in mammary tumors, as a function of contrast agent size, to determine what effect ROI size mi...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-200204000-00003

    authors: Aref M,Brechbiel M,Wiener EC

    更新日期:2002-04-01 00:00:00

  • Diminished cerebrospinal fluid beta-endorphin concentration in monkeys with arachnoiditis.

    abstract::Altered concentrations of brain beta endorphin and spinal cord encephalin have been reported in mice with iatrogenic arachnoiditis. We measured beta-endorphin concentration in cerebrospinal fluid (CSF) in normal monkeys and in monkeys with various degrees of arachnoiditis resulting from myelography and spinal surgery ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198803000-00006

    authors: Lipman BT,Haughton VM

    更新日期:1988-03-01 00:00:00

  • The effect of some iodinated contrast media on human plasma butyrylcholinesterase activity.

    abstract::The effect of three iodinated contrast media (CM) on human plasma butyrylcholinesterase (BuChE) activity was studied during the intravenous pyelography (i.v.P). BuChE is an enzyme that participates in the metabolism of acetylcholine and hydrolyzes food esters and drugs such as nondepolarizing muscle relaxants and loca...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199805000-00008

    authors: Mironidou M,Ximitidou O,Christopoulos S,Kokkas B

    更新日期:1998-05-01 00:00:00

  • Comparison of Fenestra VC Contrast-enhanced computed tomography imaging with gadopentetate dimeglumine and ferucarbotran magnetic resonance imaging for the in vivo evaluation of murine liver damage after ischemia and reperfusion.

    abstract:OBJECTIVES:Comparison of intravenous Fenestra VC-enhanced computed tomography (CT) with gadopentetate dimeglumine and Ferucarbotran contrast-enhanced magnetic resonance imaging (MRI) for the in vivo imaging of hepatic ischemia/reperfusion injury (IRI) in a murine model. MATERIAL AND METHODS:After induction of hepatic ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e318155aa2e

    authors: Choukèr A,Lizak M,Schimel D,Helmberger T,Ward JM,Despres D,Kaufmann I,Bruns C,Löhe F,Ohta A,Sitkovsky MV,Klaunberg B,Thiel M

    更新日期:2008-02-01 00:00:00

  • Observer variation in abdominal CT.

    abstract::Observer performance in radiologic interpretation has traditionally been based upon Receiver Operating Characteristic (ROC) analysis. A statistical method that evaluates the reproducibility or consistency of radiologic interpretation is presented. Since this method is not based upon pathologic verification, it cannot ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198411000-00024

    authors: Herman S,DeBoer G,Rideout DF,Majesky IF

    更新日期:1984-11-01 00:00:00

  • Incidence and methods of diagnosis of musculoskeletal injuries incurred in Operations Desert Shield and Desert Storm.

    abstract:RATIONALE AND OBJECTIVES:The authors studied the incidence and distribution of orthopedic injuries sustained in Operation Desert Shield and Desert Storm by evaluating whether existing diagnostic imaging modalities were sufficient to diagnose the types of musculoskeletal injuries incurred. The authors also sought to det...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199703000-00006

    authors: Truax AL,Chandnani VP,Chacko AK,Gonzalez DM

    更新日期:1997-03-01 00:00:00

  • A new animal model for testing renal tolerance of contrast agents.

    abstract:RATIONALE AND OBJECTIVES:To develop a new animal model for the evaluation of the renal tolerance of contrast agent and its application to diatrizoate and iotrolan injections in comparison to saline and mannitol solution. MATERIALS AND METHODS:The nephrotoxic potential of intravenously injected contrast agents in Beagl...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/01.rli.0000087096.61127.13

    authors: Krause W,Gilles T

    更新日期:2003-11-01 00:00:00

  • Fluorinated blood substitute retention in the rat measured by fluorine-19 magnetic resonance imaging.

    abstract:RATIONALE AND OBJECTIVES:Emulsions of perfluorocarbons (PFCs) have been tested as blood substitutes. However, evidence exists that there is long-term retention of some PFCs by the organs of the reticuloendothelial system (RES). The authors investigate organ retention of the blood substitute component, perfluorotripropy...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199208000-00012

    authors: Meyer KL,Carvlin MJ,Mukherji B,Sloviter HA,Joseph PM

    更新日期:1992-08-01 00:00:00

  • Comparison of 1.5 and 3 T BOLD MR to study oxygenation of kidney cortex and medulla in human renovascular disease.

    abstract:OBJECTIVES:Imaging of the kidney using blood oxygen level dependent MR presents a major opportunity to examine differences in tissue oxygenation within the cortex and medulla applicable to human disease. We sought to define the differences between regions within kidneys and to optimize selection of regions of interest ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e3181b4c1e8

    authors: Gloviczki ML,Glockner J,Gomez SI,Romero JC,Lerman LO,McKusick M,Textor SC

    更新日期:2009-09-01 00:00:00

  • Diatrizoate contrast agents: 2-amino-5-acetamido-, and 3,5-diamino-2,4,6-triiodobenzoates.

    abstract::We have examined the metabolic behavior of several triiodobenzoic acid derivatives because of the observed mutagenicity and cytotoxicity of 3-amino-5-acetamido-2,4,6-triiodobenzoate (I) and 3,5-diamino-2,4,6-triiodobenzoate (II). Measurements were facilitated using iodine-131 (131I)-labeled compounds. Drug retention i...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:

    authors: Weiss R,Hsu B,Wheeler L,Norman A,Riley RF

    更新日期:1981-11-01 00:00:00

  • Fibroblast response to gadolinium: role for platelet-derived growth factor receptor.

    abstract:OBJECTIVE:The purpose of this study was to assess the effects of gadolinium (Gd3+), provided as gadolinium chloride, on fibroblast function. MATERIALS AND METHODS:Human dermal fibroblasts in monolayer culture and intact skin in organ culture were exposed to the lanthanide metal (1-20 μM). RESULTS:Increased proliferat...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e3181e943d2

    authors: Bhagavathula N,Dame MK,DaSilva M,Jenkins W,Aslam MN,Perone P,Varani J

    更新日期:2010-12-01 00:00:00

  • Automated calibration in vascular X-ray images using the accurate localization of catheter marker bands.

    abstract:RATIONALE AND OBJECTIVES:To develop a new automated calibration method for vessel measurements in vascular x-ray images. METHODS:Radiopaque marker bands mounted equidistantly on a small catheter were acquired in vitro at five image intensifier (II) sizes in x-ray projection images. The positions of the marker centers ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-200004000-00002

    authors: Van Assen HC,Vrooman HA,Egmont-Petersen M,Bosch HG,Koning G,Van Der Linden EL,Goedhart B,Reiber JH

    更新日期:2000-04-01 00:00:00

  • Ultrasonic echoes registered from erythrocytes.

    abstract::Erythrocytes at various concentrations were examined with a sensitive A-mode ultrasonic scanner; simultaneous measurements were made under light microscopic control. Individual erythrocytes caused weak (about 1 dB) echoes while erythrocyte aggregates (ten to 100 cells) produced stronger echoes (up to 15 dB), grossly p...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198508000-00014

    authors: Alanen A,Kormano M

    更新日期:1985-08-01 00:00:00

  • First-pass evaluation of myocardial output during dipyridamole stress using turbo-FLASH magnetic resonance imaging.

    abstract:RATIONALE AND OBJECTIVES:This study evaluated the value of dynamically enhanced fast low-angle shot (FLASH) magnetic resonance (MR) imaging in measuring cardiac output with and without dipyridamole pharmacological stress. METHODS:Ten subjects underwent rest and stress MR imaging. Rest images were acquired using electr...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199611000-00003

    authors: Tello R,Hartnell GG,Hill TC,Cerel A,Finn JP,Kamalesh M,Cohen M,Lewis S

    更新日期:1996-11-01 00:00:00

  • A Single-Arm, Multicenter Validation Study of Prostate Cancer Localization and Aggressiveness With a Quantitative Multiparametric Magnetic Resonance Imaging Approach.

    abstract:OBJECTIVES:The aims of this study were to assess the discriminative performance of quantitative multiparametric magnetic resonance imaging (mpMRI) between prostate cancer and noncancer tissues and between tumor grade groups (GGs) in a multicenter, single-vendor study, and to investigate to what extent site-specific dif...

    journal_title:Investigative radiology

    pub_type: 杂志文章,多中心研究

    doi:10.1097/RLI.0000000000000558

    authors: Maas MC,Litjens GJS,Wright AJ,Attenberger UI,Haider MA,Helbich TH,Kiefer B,Macura KJ,Margolis DJA,Padhani AR,Selnæs KM,Villeirs GM,Fütterer JJ,Scheenen TWJ

    更新日期:2019-07-01 00:00:00

  • Manganese dipyridoxyl diphosphate (MnDPDP)-enhanced magnetic resonance imaging of acute reperfused myocardial injury in a cat model: part I: comparison with pathologic examination.

    abstract:RATIONALE AND OBJECTIVES:To investigate the capacity of manganese dipyridoxyl diphosphate (MnDPDP)-enhanced magnetic resonance imaging (MRI) to discriminate the injured myocardium from the normal myocardium in a cat model. MATERIALS AND METHODS:Fourteen cats were prepared for acute myocardial infarction with 90-minute...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:

    authors: Kim TH,Yang DH,Choi JW,Kim ST,Yoon JH,Shin JH,Seo JB,Gong GY,Lim TH

    更新日期:2005-01-01 00:00:00

  • Ultrasound Time-Harmonic Elastography of the Pancreas: Reference Values and Clinical Feasibility.

    abstract:OBJECTIVES:Pancreatic ductal adenocarcinoma (PDAC) is a very aggressive tumor with a very low 5-year survival rate of 8%. The aims of this study are to determine reference values and physiologic confounders in healthy pancreas and to assess the diagnostic accuracy of ultrasound time-harmonic elastography (THE) in the d...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000638

    authors: Burkhardt C,Tzschätzsch H,Schmuck R,Bahra M,Jürgensen C,Pelzer U,Hamm B,Braun J,Sack I,Marticorena Garcia SR

    更新日期:2020-05-01 00:00:00

  • Screening mammography. A risk versus risk decision.

    abstract::The potential risk of a radiologic procedure often is compared with the potential benefit of the procedure. While risk vs. benefit analysis has been useful as a step toward increased communication and understanding among radiologists, referring physicians, and the general public, it has the disadvantage that risk and ...

    journal_title:Investigative radiology

    pub_type: 杂志文章,评审

    doi:10.1097/00004424-198901000-00005

    authors: Ritenour ER,Hendee WR

    更新日期:1989-01-01 00:00:00

  • Experimental nephrotoxicity of the radiocontrast agents iohexol, ioxaglate, and iothalamate. An in vitro and in vivo study.

    abstract::The authors compared the renal toxicity of the low osmolality radiocontrast agents, iohexol and ioxaglate, and the ionic agent, iothalamate, at equivalent iodine dose, using experimental models in vitro and in vivo. In isolated perfused rat kidneys, all agents induced comparable biphasic hemodynamic changes, associate...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199104000-00008

    authors: Brezis M,Greenfeld Z,Herman M,Meyer JJ,Heyman SN,Rosen S

    更新日期:1991-04-01 00:00:00

  • Noninvasive inductive stent heating: alternative approach to prevent instent restenosis?

    abstract:RATIONALE AND OBJECTIVES:To test noninvasive inductive heating of implanted vascular stents as an alternative approach for reduction or prevention of neointimal hyperplasia. METHODS:Calorimetric pretests were performed to get an orientation on the different parameters of influence for inductive heating of stents. The ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/01.rli.0000117881.42422.72

    authors: Floren MG,Günther RW,Schmitz-Rode T

    更新日期:2004-05-01 00:00:00

  • Correlation of Histological Vessel Characteristics and Diffusion-Weighted Imaging Intravoxel Incoherent Motion-Derived Parameters in Pancreatic Ductal Adenocarcinomas and Pancreatic Neuroendocrine Tumors.

    abstract:OBJECTIVE:To investigate the correlation between intravoxel incoherent motion (IVIM) model-derived parameters and histologically determined microvascularity in pancreatic ductal adenocarcinomas (PDACs) and pancreatic neuroendocrine tumors (PNETs). MATERIALS AND METHODS:From April 2013 to May 2014, 42 patients with mal...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000187

    authors: Klau M,Mayer P,Bergmann F,Maier-Hein K,Hase J,Hackert T,Kauczor HU,Grenacher L,Stieltjes B

    更新日期:2015-11-01 00:00:00

  • Perfusion quantitation by ultrafast computed tomography.

    abstract::Flow measurements can be made with computed tomography (CT) scanners using iodinated, nonionic contrast media as a first-pass indicator. Ultrafast CT (UFCT) is an ideal machine to make these measurements because of its short scan time (50 mseconds) and interscan delay (< or = 0.6 seconds). Additionally, UFCT can acqui...

    journal_title:Investigative radiology

    pub_type: 杂志文章,评审

    doi:10.1097/00004424-199212002-00004

    authors: Gould RG

    更新日期:1992-12-01 00:00:00

  • Percutaneous radiofrequency ablation of hepatic colorectal metastases: technique, indications, results, and new promises.

    abstract::Surgical resection is the standard of care for colorectal metastases isolated to the liver. However, only 10-25% of the patients are eligible for resection because of extent and location of the disease in the liver or concurrent medical conditions. Image-guided radiofrequency (RF) ablation is a minimally invasive tech...

    journal_title:Investigative radiology

    pub_type: 杂志文章,评审

    doi:10.1097/00004424-200411000-00007

    authors: Lencioni R,Crocetti L,Cioni D,Della Pina C,Bartolozzi C

    更新日期:2004-11-01 00:00:00

  • Opacification phase effects of angiographic contrast medium on left ventricular size and function: influence of initial ventricular volume and the pericardium.

    abstract::Prior studies of the opacification-phase effects of left ventricular (LV) injection of angiographic contrast medium (CM) on LV size and function have yielded discrepant results. A sensitive ultrasonic technique was used to measure LV dimension (Di) in 10 open-chest dogs with physiologic heart rates, and injection of s...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198209000-00009

    authors: LeWinter MM,Pavelec RS

    更新日期:1982-09-01 00:00:00

  • A comparison of iopromide with iopamidol and iohexol for contrast-enhanced computed tomography.

    abstract:RATIONALE AND OBJECTIVES:Iopromide is a new monomeric, nonionic contrast agent that exhibits low osmolality and low viscosity in high concentration in aqueous solutions. Double-blind, randomized clinical trials have established the efficacy, safety, and tolerance of iopromide for excretory urography, coronary angiograp...

    journal_title:Investigative radiology

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1097/00004424-199405001-00015

    authors: Goldberg SN,Abrahams J,Drayer BP,Golding S,Bernardino M,Brunetti J

    更新日期:1994-05-01 00:00:00

  • A direct comparison of noninvasive coronary angiography by electron beam tomography and navigator-echo-based magnetic resonance imaging for the detection of restenosis following coronary angioplasty.

    abstract:RATIONALE AND OBJECTIVES:To compare electron beam tomography (EBT) with MR imaging (MRI) for detection of restenosis after coronary angioplasty (PTCA). METHODS:One hundred eighteen patients after PTCA were investigated. By EBT, 50 axial images were acquired (3-mm slice thickness, 120-160 mL radiographic contrast agent...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-200207000-00005

    authors: Ropers D,Regenfus M,Stilianakis N,Birke S,Kessler W,Moshage W,Laub G,Daniel WG,Achenbach S

    更新日期:2002-07-01 00:00:00

  • Increased ablation zones using a cryo-based internally cooled bipolar RF applicator in ex vivo bovine liver.

    abstract:PURPOSE:To evaluate the feasibility of ex vivo ablation implementing a cryo-based internally cooled bipolar radiofrequency (RF) applicator and to determine the influence of power and gas pressure on the size and shape of the resulting ablation zones. MATERIALS AND METHODS:Two hundred twenty-five ablations were perform...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e3181b66d11

    authors: Rempp H,Voigtländer M,Clasen S,Kempf S,Neugebauer A,Schraml C,Schmidt D,Claussen CD,Enderle MD,Goldberg SN,Pereira PL

    更新日期:2009-12-01 00:00:00

  • Does dilution of contrast media affect contrast enhancement? An experimental study in rats.

    abstract::The effect of contrast media (CM) dilution on contrast enhancement was studied using CM representing four structurally different molecular types at osmolalities ranging from 135 to 1340 mosm/kg. Diatrizoate (ionic monomer), iopamidol (nonionic monomer), ioxaglate (ionic dimer), and iodecol (nonionic dimer) were each g...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198809001-00014

    authors: Dean PB,Kivisaari L,Kormano M

    更新日期:1988-09-01 00:00:00

  • A double-blind comparative study of Hexabrix and Renografin-76 in aortography and visceral arteriography.

    abstract::A diatrizoate compound (Renografin-76) and low osmolality Hexabrix were compared in a double-blind study of 50 adults undergoing arteriographic examination. Subjective and objective assessment of pain reaction for each contrast injection rated lower overall for Hexabrix. Discomfort associated with Renografin was great...

    journal_title:Investigative radiology

    pub_type: 临床试验,杂志文章

    doi:10.1097/00004424-198411001-00012

    authors: Barth KH,Mertens MA

    更新日期:1984-11-01 00:00:00

  • Hepatic kinetics and magnetic resonance imaging of gadolinium-EOB-DTPA in dogs.

    abstract:RATIONALE AND OBJECTIVES:To measure the hepatic uptake and biliary elimination kinetics of gadolinium (Gd)-EOB-DTPA in dogs. METHOD:Two groups of four beagles each were anesthetized and given an intravenous bolus of 25 mumol/kg or 250 mumol/kg of Gd-EOB-DTPA. Blood, hepatic bile, and urine were collected over 140 minu...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199604000-00005

    authors: Benness G,Khangure M,Morris I,Warwick A,Burrows P,Vogler H,Weinmann HJ

    更新日期:1996-04-01 00:00:00