Evaluation of noninvasive follow-up methods for the detection of intracranial in-stent restenosis: a phantom study.

Abstract:

OBJECTIVES:Intra-arterial digital subtraction angiography (IA-DSA), an invasive procedure, is the current reference examination after percutaneous transluminal angioplasty and stenting for the detection of in-stent restenosis (ISR). In this phantom study, we evaluated flat-panel angiographic computed tomography after intravenous contrast agent application (IV-ACT) and multidetector computed tomographic angiography (MDCTA) as potential noninvasive follow-up alternatives after intracranial percutaneous transluminal angioplasty and stenting. MATERIALS AND METHODS:We simulated an intracranial vessel using a silicon tube placed inside a human skull. Three different stent systems were deployed inside the silicon tubes, each with diameters of 3 or 4 mm. Three grades of ISR (25%, 50%, and 75%) were simulated. The IA-DSA and IV-ACT examinations were performed on a flat-panel detector angiography system. The MDCTA images were acquired with a 128-slice computed tomographic scanner. The mean stenosis diameters, measured with each technique, were compared using the Bland-Altman plot. The difference between the known stenosis diameter and the measured stenosis diameter was calculated for each examination. RESULTS:Stenosis measurements on the IA-DSA images showed no statistically significant differences compared with the known stenosis diameters (P = 0.19). In the 3-mm stent category, when compared with the known stenosis diameter, mean (SD) differences of 0.01 (0.15) mm, 0.03 (0.24) mm and 0.16 (0.5) mm were calculated for the IA-DSA, IV-ACT, and MDCTA stenosis measurements, respectively. As for the 4-mm stents, IA-DSA and IV-ACT were again very accurate, with mean (SD) differences of -0.03 (0.11) mm and 0.07 (0.19) mm, respectively, compared with the known stenosis diameters, whereas MDCTA overestimated ISR, with a mean (SD) difference of 0.49 (0.53) mm. The Bland-Altman plots show a mean (SD) difference of 0.08 (0.2) mm between IA-DSA and IV-ACT (95% confidence interval, 0.05-0.11) and a mean (SD) difference of 0.34 (0.56) mm between IA-DSA and MDCTA measurements (95% confidence interval, 0.25-0.42). CONCLUSIONS:In our phantom study, IA-DSA was the only examination to predict accurately degrees of stenosis compared with the known stenosis diameters. The results of the IV-ACT measurements were comparable with those of IA-DSA. Multidetector computed tomographic angiography was less accurate in the quantification of stenosis, usually overestimating ISR.

journal_name

Invest Radiol

journal_title

Investigative radiology

authors

Psychogios MN,Schramm P,Amelung N,Pilgram-Pastor SM,Gröschel K,Wasser K,Frölich AM,Mohr A,Knauth M

doi

10.1097/RLI.0b013e318276db43

subject

Has Abstract

pub_date

2013-02-01 00:00:00

pages

98-103

issue

2

eissn

0020-9996

issn

1536-0210

journal_volume

48

pub_type

杂志文章
  • Evaluation of CT time-density curves of lower-limb veins.

    abstract:UNLABELLED:Szapiro D, Ghaye B, Willems V, et al. Evaluation of CT time-density curves of lower-limb veins. Invest Radiol 2001;36:164-169. RATIONALE AND OBJECTIVES:To evaluate time-density curves of the lower-limb veins for optimization of CT venography. METHODS:Fifty patients referred for chest CT were randomized int...

    journal_title:Investigative radiology

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1097/00004424-200103000-00005

    authors: Szapiro D,Ghaye B,Willems V,Zhang L,Albert A,Dondelinger RF

    更新日期:2001-03-01 00:00:00

  • Screening mammography. A risk versus risk decision.

    abstract::The potential risk of a radiologic procedure often is compared with the potential benefit of the procedure. While risk vs. benefit analysis has been useful as a step toward increased communication and understanding among radiologists, referring physicians, and the general public, it has the disadvantage that risk and ...

    journal_title:Investigative radiology

    pub_type: 杂志文章,评审

    doi:10.1097/00004424-198901000-00005

    authors: Ritenour ER,Hendee WR

    更新日期:1989-01-01 00:00:00

  • 3.0 Tesla high spatial resolution contrast-enhanced magnetic resonance angiography (CE-MRA) of the pulmonary circulation: initial experience with a 32-channel phased array coil using a high relaxivity contrast agent.

    abstract:PURPOSE:To evaluate the technical feasibility of high spatial resolution contrast-enhanced magnetic resonance angiography (CE-MRA) with highly accelerated parallel acquisition at 3.0 T using a 32-channel phased array coil, and a high relaxivity contrast agent. MATERIALS AND METHODS:Ten adult healthy volunteers (5 men,...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/01.rli.0000261937.77365.6a

    authors: Nael K,Fenchel M,Krishnam M,Finn JP,Laub G,Ruehm SG

    更新日期:2007-06-01 00:00:00

  • Fluorescent bacterial magnetic nanoparticles as bimodal contrast agents.

    abstract:OBJECTIVES:The purpose of this study was to assess whether fluorochrome-coupled bacterial magnetic nanoparticles can be used as bimodal contrast agent for both magnetic resonance imaging (MRI) and near-infrared fluorescence optical (NIRF) imaging of cultured macrophages. MATERIALS AND METHODS:Bacterial magnetic nanopa...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/01.rli.0000255832.44443.e7

    authors: Lisy MR,Hartung A,Lang C,Schüler D,Richter W,Reichenbach JR,Kaiser WA,Hilger I

    更新日期:2007-04-01 00:00:00

  • Systematic evaluation and increased structure in a radiology elective.

    abstract::Diagnostic radiology is expanding, playing an increasingly central role in patient care, which heightens the importance of radiology teaching in undergraduate medical education. This study examined the impact of increased structure and systematic evaluation on student performance in a radiology elective. The evaluatio...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198505000-00003

    authors: Blane CE,Calhoun JG,Maxim BR,Martel W,Davis WK

    更新日期:1985-05-01 00:00:00

  • Sclerotherapy of the gallbladder in pigs. Development of a balloon catheter for a single-step procedure.

    abstract::Gallbladder sclerotherapy after permanent cystic duct occlusion, to prevent gallstone recurrence in nonsurgical gallstone therapy, is at least a two-stage procedure. A balloon catheter was developed to perform gallbladder sclerotherapy with only temporary occlusion of the cystic duct, and the efficacy and safety of th...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199109000-00005

    authors: Brakel K,Laméris JS,Vergunst H,Ten Kate FJ,Nijs HG,Terpstra OT

    更新日期:1991-09-01 00:00:00

  • Contrast-to-noise-ratio measurements in three-dimensional magnetic resonance angiography.

    abstract:RATIONALE AND OBJECTIVES:The authors report on the development and preliminary validation of a technique for measuring contrast-to-noise ratio (CNR) at all points along selected vessel segments in the original three-dimensional magnetic resonance angiography (MRA) dataset. METHODS:Contrast-to-noise ratio dependencies ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199311000-00005

    authors: Du Y,Parker DL,Davis WL,Blatter DD

    更新日期:1993-11-01 00:00:00

  • Lactate accumulation in ischemic- and anoxic-isolated rat hearts assessed by H-1 spectroscopy.

    abstract::Proton magnetic resonance (MR) spectroscopy with homonuclear editing was used to assess lactate accumulation in ischemic and anoxic hearts perfused according to the Langendorff method. An increase in the lactate signal was observed after 5 minutes of ischemia and after 10 to 20 minutes of anoxia. This study demonstrat...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198708000-00004

    authors: Richards TL,Terrier F,Sievers RE,Lipton MJ,Moseley ME,Higgins CB

    更新日期:1987-08-01 00:00:00

  • Phantom testing of peripheral artery. Absolute blood flow measurement with digital arteriography.

    abstract::A technique to measure absolute arterial blood flow in ml/min has been developed utilizing software programs with high-speed digital recording for the off-line analysis of intra-arterial injections of contrast medium. Measurements of pulsatile flow in a phantom for a physical flow model showed that calculations with t...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198503000-00017

    authors: Forbes G,Gray JE,Felmlee JP

    更新日期:1985-03-01 00:00:00

  • Blood velocity calculated from volumetric dynamic computed tomography angiography.

    abstract:OBJECTIVE:Though functional intravascular parameters such as blood velocity and direction of blood flow are available via imaging modalities such as Doppler ultrasound and phase contrast magnetic resonance imaging, such quantitative information is not yet supported by computed tomography (CT). In this study, we examine...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e3181ea3588

    authors: Barfett JJ,Fierstra J,Mikulis DJ,Krings T

    更新日期:2010-12-01 00:00:00

  • The effects of radiographic contrast media on myocardial contractility and coronary resistance: osmolality, ionic concentration, and viscosity.

    abstract::With the ongoing development of new contrast agents, questions develop concerning the cardiac effects of these drugs. We used the perfused rat heart model to investigate the effects on cardiac and coronary function of hypertonic ionic (sodium chloride) and nonionic (glucose) solutions and conventional and low osmolali...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199003000-00009

    authors: Fleetwood G,Bettmann MA,Gordon JL

    更新日期:1990-03-01 00:00:00

  • Improved diagnosis of pulmonary emphysema using in vivo dark-field radiography.

    abstract:OBJECTIVES:The purpose of this study was to assess whether the recently developed method of grating-based x-ray dark-field radiography can improve the diagnosis of pulmonary emphysema in vivo. MATERIALS AND METHODS:Pulmonary emphysema was induced in female C57BL/6N mice using endotracheal instillation of porcine pancr...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000067

    authors: Meinel FG,Yaroshenko A,Hellbach K,Bech M,Müller M,Velroyen A,Bamberg F,Eickelberg O,Nikolaou K,Reiser MF,Pfeiffer F,Yildirim AÖ

    更新日期:2014-10-01 00:00:00

  • Magnetic resonance imaging in a spinal abscess model. Preliminary report.

    abstract:RATIONAL AND OBJECTIVES:Magnetic resonance (MR) scan technique and lesion detectability were evaluated using a newly developed spinal abscess model in the New Zealand White rabbit. METHODS:To create the lesion, an epidural needle was inserted under fluoroscopic guidance in the lumbar region and advanced to penetrate t...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199804000-00008

    authors: Runge VM,Williams NM,Lee C,Timoney JF

    更新日期:1998-04-01 00:00:00

  • Importance of parametric mapping and deconvolution in analyzing magnetic resonance myocardial perfusion images.

    abstract:AIM:: We sought to improve the clinical interpretation of first-pass myocardial magnetic resonance perfusion. Parametric analyses of the myocardial distribution of the contrast agent have been proposed. The objective of the present study was to compare the effectiveness of visual analysis and of a parametric approach i...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/01.rli.0000197980.89673.4b

    authors: Carme S,Maï W,Mazzadi A,Janier M,Revel D,Magnin I,Wiart M,Neyran B,Canet-Soulas E

    更新日期:2006-04-01 00:00:00

  • Correlation of flow velocity measurements by magnetic resonance phase contrast imaging and intravascular Doppler ultrasound.

    abstract:RATIONALE AND OBJECTIVES:The authors compare the magnetic resonance (MR) phase contrast flow velocity measurements in varying concentric stenoses with invasive measurements obtained with a Doppler guidewire. METHODS:Flow velocity measurements were obtained using a calibrated 0.018 inch 12 MHz Doppler guidewire and a 1...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199808000-00001

    authors: Hoppe M,Heverhagen JT,Froelich JJ,Kunisch-Hoppe M,Klose KJ,Wagner HJ

    更新日期:1998-08-01 00:00:00

  • Low-dose spiral computed tomography of the thorax: comparison with the standard-dose technique.

    abstract:RATIONALE AND OBJECTIVES:This study was conducted to determine whether significant reduction in radiation dose (250 mAs-->50 mAs), in chest computed tomography (CT) using volume acquisition affects image quality or the detectability of pathologic findings in the lung and mediastinum. METHODS:Phantom studies were condu...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199802000-00002

    authors: Takahashi M,Maguire WM,Ashtari M,Khan A,Papp Z,Alberico R,Campbell W,Eacobacci T,Herman PG

    更新日期:1998-02-01 00:00:00

  • Assessment of large bowel motility by cine magnetic resonance imaging using two different prokinetic agents: a feasibility study.

    abstract:OBJECTIVES:We sought to assess large bowel motility, induced by 2 prokinetic agents, senna tea and erythromycin, using functional cine magnetic resonance imaging (MRI). MATERIALS AND METHODS:Twelve volunteers underwent functional cine MRI before and after the administration of senna tea or erythromycin. The protocol c...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/01.rli.0000183054.43131.a8

    authors: Buhmann S,Kirchhoff C,Wielage C,Mussack T,Reiser MF,Lienemann A

    更新日期:2005-11-01 00:00:00

  • Mechanical and biochemical cardiac disturbances induced by bolus administration of iodinated contrast media and noniodinated solutions.

    abstract:RATIONALE AND OBJECTIVES:Bolus injection of iodinated contrast media has been observed to alter myocardial mechanical function, but the consequences on cellular metabolism are poorly documented. Modifications of metabolic parameters (intracellular pH as well as adenosine triphosphate [ATP], phosphocreatine, and inorgan...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199501000-00001

    authors: Goossens A,Vander Elst L,Van Haverbeke Y,Muller RN

    更新日期:1995-01-01 00:00:00

  • Assessment and monitoring tumor vascularity with contrast-enhanced ultrasound maximum intensity persistence imaging.

    abstract:OBJECTIVES:Contrast-enhanced ultrasound imaging is increasingly being used in the clinic for assessment of tissue vascularity. The purpose of our study was to evaluate the effect of different contrast administration parameters on the in vivo ultrasound imaging signal in tumor-bearing mice using a maximum intensity pers...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e3181f9202d

    authors: Pysz MA,Foygel K,Panje CM,Needles A,Tian L,Willmann JK

    更新日期:2011-03-01 00:00:00

  • Vein graft-coated stents for endovascular occlusion of canine experimental arteriovenous fistulae.

    abstract:RATIONALE AND OBJECTIVES:To evaluate different vein graft-coated stent systems in the endovascular treatment of experimental arteriovenous fistulae (AVF) in a canine model. METHODS:Bilateral carotid-to-external jugular vein AVF were created. Two balloon-expandable tantalum stents (Strecker stent), two self-expanding n...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199901000-00004

    authors: Schellhammer F,Wahkloo AK,Nagursky H,Schumacher M

    更新日期:1999-01-01 00:00:00

  • Comparative evaluation of digital radiography versus conventional radiography of fractured skulls.

    abstract:OBJECTIVES:The authors assessed the relative efficacy of conventional and digital storage-phosphor radiographs for the detection of skull fractures. METHODS:Fifty conventional film-screen radiographs (FSR) and 50 digital storage-phosphor radiographs (DR) with 66 fractures were compared. Five radiologists evaluated ima...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199308000-00005

    authors: Langen HJ,Klein HM,Wein B,Stargardt A,Günther RW

    更新日期:1993-08-01 00:00:00

  • Evaluation of radiologist interpretive performance using blinded reads by multiple external readers.

    abstract:OBJECTIVE:To demonstrate a method of assessing radiologic diagnostic agreement utilizing multiple blinded external readers. METHODS:Six body CT studies interpreted by one reader (primary reader) at the host institution were compiled with patient identifiers removed. Brief clinical histories that were available to the ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e3181d2ee97

    authors: Ryan AF,Semelka RC,Molina PL,Yonkers S,Vaidean G

    更新日期:2010-04-01 00:00:00

  • D-galactose-based signal-enhanced color Doppler sonography of breast tumors and tumorlike lesions.

    abstract:RATIONALE AND OBJECTIVES:This study sought to evaluate prospectively the diagnostic potential of unenhanced and enhanced color Doppler and power Doppler for the differentiation of tumors and tumorlike lesions of the breast. METHODS:Ninety-two patients with 110 tumors or tumorlike lesions of the breast were investigate...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199902000-00003

    authors: Schroeder RJ,Maeurer J,Vogl TJ,Hidajat N,Hadijuana J,Venz S,Weber S,Felix R

    更新日期:1999-02-01 00:00:00

  • Tubal sterilization by selective catheterization in an animal model.

    abstract:RATIONAL AND OBJECTIVES:The feasibility of tubal occlusion by selective salpingography was tested in an animal model; three novel occluding materials also were tested for this application. METHODS:Unilateral selective salpingography was performed in three groups of six rabbits; fallopian tubes were embolized with etha...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199402000-00007

    authors: Maubon A,Rouanet JP,Laurent A,Joujoux JM,Cover S,Courtieu C,Wassef M,Godlewski G,Honiger J,Lopez FM

    更新日期:1994-02-01 00:00:00

  • Role of iodinated contrast material in the evaluation of myocardial infarction by computerized transmission tomography.

    abstract::In vivo and in vitro studies have shown that areas of myocardial infarctions can be delineated on CT scans after intravenous administration of iodinated contrast material to dogs with experimental myocardial infarctions. Within the first minute after intravenous administration of contrast material (initial myocardial ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198011001-00039

    authors: Higgins CB,Siemers PT,Newell JD,Schmidt W

    更新日期:1980-11-01 00:00:00

  • Clinical comparison between a currently available single-loop and an investigational dual-channel endorectal receive coil for prostate magnetic resonance imaging: a feasibility study at 1.5 and 3 T.

    abstract:OBJECTIVES:The objectives of this study were to test the feasibility of an investigational dual-channel next-generation endorectal coil (NG-ERC) in vivo, to quantitatively assess signal-to-noise ratio (SNR), and to get an impression of image quality compared with the current clinically available single-loop endorectal ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e3182a56678

    authors: Vos EK,Sambandamurthy S,Kamel M,McKenney R,van Uden MJ,Hoeks CM,Yakar D,Scheenen TW,Fütterer JJ

    更新日期:2014-01-01 00:00:00

  • Ultrasound analysis of tongue, hyoid, and larynx activity during swallowing.

    abstract::Using real-time ultrasound, the motions of the tongue, hyoid bone, and larynx were monitored and timed during swallowing in ten normal subjects. A well-defined propulsive wave of the tongue was observed during swallowing a 5-cc water bolus. The body of the hyoid bone was identified on the ultrasound scan as a high ech...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198403000-00003

    authors: Shawker TH,Sonies B,Hall TE,Baum BF

    更新日期:1984-03-01 00:00:00

  • The importance of nuclear magnetic relaxation dispersion (NMRD) profiles in MRI contrast media development.

    abstract::Observation of the relaxivity of MRI contrast media over a wide range of magnetic fields is not only necessary for predicting their efficiency at any field but also compulsory for understanding and improving their mechanisms of action. The best experimental approach to this problem is the field cycling method, which a...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198809001-00047

    authors: Muller RN,Vander Elst L,Rinck PA,Vallet P,Maton F,Fischer H,Roch A,Van Haverbeke Y

    更新日期:1988-09-01 00:00:00

  • Microbubble contrast agents: targeted ultrasound imaging and ultrasound-assisted drug-delivery applications.

    abstract::The use of microbubble contrast agents for general tissue delineation and perfusion enjoys steady interest in ultrasound imaging. Microbubbles as contrast materials require a small dosage and show excellent detection sensitivity. Targeting ligands on the surface of microbubbles permit the selective accumulation of the...

    journal_title:Investigative radiology

    pub_type: 杂志文章,评审

    doi:10.1097/01.rli.0000199292.88189.0f

    authors: Klibanov AL

    更新日期:2006-03-01 00:00:00

  • Dual Plasma Sampling Method to Determine the Hepatic and Renal Clearance of the 2 Diastereoisomers of Gd-EOB-DTPA.

    abstract:OBJECTIVES:The aim of this study was to develop a method to determine hepatic and renal clearance of the 2 diastereoisomers (Gd-A, Gd-B) of Gd-EOB-DTPA separately. MATERIALS AND METHODS:Between July 2017 and February 2018, 41 patients with hepatic disease were prospectively included. For each patient, 1 mL of iopromid...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000622

    authors: Yuan X,Wang S,Shi W,Cai Y,Chen Y,Chen M,Peng Y,Ao G

    更新日期:2020-03-01 00:00:00