Abstract:
PURPOSE:To evaluate the technical feasibility of high spatial resolution contrast-enhanced magnetic resonance angiography (CE-MRA) with highly accelerated parallel acquisition at 3.0 T using a 32-channel phased array coil, and a high relaxivity contrast agent. MATERIALS AND METHODS:Ten adult healthy volunteers (5 men, 5 women, aged 21-66 years) underwent high spatial resolution CE-MRA of the pulmonary circulation. Imaging was performed at 3 T using a 32-channel phase array coil. After intravenous injection of 1 mL of gadobenate dimeglumine (Gd-BOPTA) at 1.5 mL/s, a timing bolus was used to measure the transit time from the arm vein to the main pulmonary artery. Subsequently following intravenous injection of 0.1 mmol/kg of Gd-BOPTA at the same rate, isotropic high spatial resolution data sets (1 x 1 x 1 mm3) CE-MRA of the entire pulmonary circulation were acquired using a fast gradient-recalled echo sequence (TR/TE 3/1.2 milliseconds, FA 18 degrees) and highly accelerated parallel acquisition (GRAPPA x 6) during a 20-second breath hold. The presence of artifact, noise, and image quality of the pulmonary arterial segments were evaluated independently by 2 radiologists. Phantom measurements were performed to assess the signal-to-noise ratio (SNR). Statistical analysis of data was performed by using Wilcoxon rank sum test and 2-sample Student t test. The interobserver variability was tested by kappa coefficient. RESULTS:All studies were of diagnostic quality as determined by both observers. The pulmonary arteries were routinely identified up to fifth-order branches, with definition in the diagnostic range and excellent interobserver agreement (kappa = 0.84, 95% confidence interval 0.77-0.90). Phantom measurements showed significantly lower SNR (P < 0.01) using GRAPPA (17.3 +/- 18.8) compared with measurements without parallel acquisition (58 +/- 49.4). CONCLUSION:The described 3 T CE-MRA protocol in addition to high T1 relaxivity of Gd-BOPTA provides sufficient SNR to support highly accelerated parallel acquisition (GRAPPA x 6), resulting in acquisition of isotopic (1 x 1 x 1 mm3) voxels over the entire pulmonary circulation in 20 seconds.
journal_name
Invest Radioljournal_title
Investigative radiologyauthors
Nael K,Fenchel M,Krishnam M,Finn JP,Laub G,Ruehm SGdoi
10.1097/01.rli.0000261937.77365.6asubject
Has Abstractpub_date
2007-06-01 00:00:00pages
392-8issue
6eissn
0020-9996issn
1536-0210pii
00004424-200706000-00009journal_volume
42pub_type
杂志文章abstract:RATIONALE AND OBJECTIVES:Studies describing the effects of radiographic contrast media (RCM) in leukocyte chemotaxis have been contradictory. No studies have been performed after in-vivo exposure. The authors assess the effect of RCM on leukocytes following in-vivo exposure. METHODS:Seventeen patients were studied aft...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199401000-00012
更新日期:1994-01-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:Echogenic antibody-conjugated anionic liposomes have been developed that allow directed tissue targeting and acoustic enhancement. These are not efficient for gene delivery. A cationic formulation that allows directed gene delivery while retaining acoustic properties may provide more efficient ...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-200012000-00007
更新日期:2000-12-01 00:00:00
abstract::Magnetic resonance spectroscopy (MRS) has been most extensively applied to the study of animal models and not humans. The major reason for this extensive animal research is due to the nature of the early magnetic resonance high-field magnets, which only permitted the study of isolated cells, tissues, or small animals....
journal_title:Investigative radiology
pub_type: 杂志文章,评审
doi:10.1097/00004424-198912000-00004
更新日期:1989-12-01 00:00:00
abstract:PURPOSE:The aim of this study was to compare qualitative and quantitative image quality and geometric distortion of 4 magnetic resonance diffusion-weighted imaging (DWI) sequences of the prostate using comparable imaging parameters and similar acquisition times. METHODS AND MATERIALS:Axial T2-weighted turbo spin echo ...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0000000000000429
更新日期:2018-04-01 00:00:00
abstract::The authors compared the renal toxicity of the low osmolality radiocontrast agents, iohexol and ioxaglate, and the ionic agent, iothalamate, at equivalent iodine dose, using experimental models in vitro and in vivo. In isolated perfused rat kidneys, all agents induced comparable biphasic hemodynamic changes, associate...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199104000-00008
更新日期:1991-04-01 00:00:00
abstract:OBJECTIVE:The aim of this study was to evaluate the influence of different weighting factors on contrast enhancement, signal-to-noise ratio (SNR), and image quality in image fusion in dual energy computed tomography (DECT) angiography. MATERIAL AND METHODS:Fifteen patients underwent a CT angiography of the aorta with ...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0b013e31818c3d4b
更新日期:2009-01-01 00:00:00
abstract:OBJECTIVES:The aim of this study was to investigate if pancreatic steatosis measured by proton density fat fraction (PDFF) is associated with exocrine pancreatic function defined by fecal elastase concentrations. MATERIALS AND METHODS:A total of 1458 volunteers (777 women; age range, 21-88 years) underwent magnetic re...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0000000000000554
更新日期:2019-07-01 00:00:00
abstract::Because of a need to correlate pulmonary microvascular changes with physiologic data during lung injury, in vitro and in vivo pulmonary capillary microangiography was performed on normal dogs and those subjected to oleic acid injury and glass bead microembolization. During these studies, no significant differences wer...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:
更新日期:1983-01-01 00:00:00
abstract::A series of 5-hydroxyacylamino-2,4,6-triiodo-N,N'-hydroxy-alkyl-isophtalamides was prepared in order to study the structural requirements for high water solubility and low toxicity. Among the amides substituted by 2-hydroxyethyl; 2,3-dihydroxypropyl; 1,3-dihydroxypropyl-; and 1,1-dihydroxy-methyl-2-oxyethyl- groups, t...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198011001-00065
更新日期:1980-11-01 00:00:00
abstract:OBJECTIVES:The objective of this study was to prospectively compare diagnostic performance and time efficiency of a double-reading paradigm in which a first-reader computer-aided detection (CAD) is followed by a fast 2-dimensional review (DR FR-CAD) with those of a double reading with second-reader CAD (SR CAD). MATER...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0000000000000009
更新日期:2014-03-01 00:00:00
abstract:OBJECTIVES:To test the feasibility of a single MR-based examination allowing for the comprehensive assessment of renal anatomy, function, and vascular status in candidates for kidney transplantation. MATERIALS AND METHODS:Twelve healthy potential kidney donors (mean age: 47 +/- 14 [standard deviation] years, 3 men and...
journal_title:Investigative radiology
pub_type: 临床试验,杂志文章
doi:10.1097/RLI.0b013e3181b35a70
更新日期:2009-11-01 00:00:00
abstract:PURPOSE:We sought to evaluate the potential of dynamic contrast enhancement after the intravenous administration of an iodine-based contrast medium in full-field digital mammography. MATERIAL AND METHODS:A protocol for image acquisition was established for contrast-enhanced mammography and the mammography unit (Senogr...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/01.rli.0000167421.83203.4e
更新日期:2005-07-01 00:00:00
abstract:OBJECTIVES:The aim of this study was to compare F-fluorodeoxyglucose (FDG) positron emission tomography (PET)/magnetic resonance (MR) (with and without diffusion-weighted imaging [DWI]) to F-FDG PET/computed tomography (CT), with regard to the assessment of nodal and extranodal involvement, in patients with Hodgkin lym...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0000000000000218
更新日期:2016-03-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:To assess the abilities of dynamic diffusion-weighted MRI to demonstrate the effects in vivo of a high-viscosity iodinated contrast agent on medullary and cortical blood flow in the rat kidney. METHODS:Dynamic diffusion-weighted, echoplanar MR images obtained from five b-value single-shot acqu...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-200011000-00001
更新日期:2000-11-01 00:00:00
abstract:OBJECTIVES:The aim of this study was to perform phantom measurements to prove the feasibility of single-source dual-energy computed tomography (DECT) of the extremities using a volume scan mode. In addition, we, for the first time, wanted to determine which concentrations of monosodium urate (MSU) in gout and calcium p...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0000000000000099
更新日期:2015-04-01 00:00:00
abstract:OBJECTIVES:The aim of this study was to investigate the impact on metal artifacts and dose efficiency of using a tin filter in combination with high-energy threshold (TH) images of a photon-counting detector (PCD) computed tomography (CT) system. MATERIALS AND METHODS:A 3D-printed spine with pedicle screws was scanned...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0000000000000535
更新日期:2019-04-01 00:00:00
abstract::Gastrografin and Amipaque with identical iodine content and flavoring were orally administered in 100 ml doses to 10 healthy volunteers in a double-blind crossover study. The nonionic Amipaque has only about one third of the osmolality of Gastrografin, and draws less fluid into the bowel lumen. Consequently there is l...
journal_title:Investigative radiology
pub_type: 临床试验,杂志文章
doi:10.1097/00004424-197811000-00008
更新日期:1978-11-01 00:00:00
abstract::Compounds containing mobile protons can act as contrast agents by increasing the value of the term (1/12 - 1/11). The efficiency of this method is markedly pH- and field-dependent. There are many such compounds allowing a choice to be made based on the characteristics of the tissue or organ, magnetic field strength, a...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198809001-00058
更新日期:1988-09-01 00:00:00
abstract::Previous investigations in this laboratory have confirmed the observation of facial muscle twitching during intracarotid injections of nonionic contrast media (CM) in rabbits. The reaction appears to be a locally mediated effect. To further investigate this reaction, cortical electroencephalogram (EEG) and facial elec...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199009000-00010
更新日期:1990-09-01 00:00:00
abstract::This article reviews the computer system hardware and software, applications programs, and computer network services that are available on microcomputers for use by the radiologist. The American College of Radiology Institute computer network is described, which is specifically designed to help the practicing radiolog...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198602000-00015
更新日期:1986-02-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:Very small dextran-coated magnetite particles were developed. These particles can be used either as immunospecific contrast agents for MRI by coupling to antibodies or as an interstitial contrast agent. METHODS:The particles were synthesized from iron chloride/dextran solutions. Size was evalu...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-200009000-00006
更新日期:2000-09-01 00:00:00
abstract:OBJECTIVES:The aims of this study were, first, to evaluate a deep learning-based, automatic glioblastoma (GB) tumor segmentation algorithm on clinical routine data from multiple centers and compare the results to a ground truth, manual expert segmentation, and second, to evaluate the quality of the segmentation results...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0000000000000484
更新日期:2018-11-01 00:00:00
abstract::Due to the nature of three-dimensional Fourier transform (3-DFT) data acquisition in magnetic resonance imaging (MRI), the spatial relation between a resolved volume element (a voxel) and the object can be manipulated easily. Those manipulations have practical consequences in terms of registering slice positions with ...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199012000-00006
更新日期:1990-12-01 00:00:00
abstract::The biliary and urinary excretion of sodium tyropanoate (Bilopaque) and sodium ipodate (Oragrafin) were studied in unanesthetized bile-fistula dogs using stepwise, increasing, intravenous infusions of the contrast materials. A constant intravenous infusion of sodium taurocholate was administered at the rate of either ...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-197701000-00017
更新日期:1977-01-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:The authors developed a two-dimensional breathhold magnetic resonance (MR) technique for the direct imaging of pulmonary emboli. METHODS:In vitro MR imaging was performed to demonstrate the potential generation of clot-blood contrast by in vivo pulmonary embolism (PE). A two-dimensional magnet...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199708000-00001
更新日期:1997-08-01 00:00:00
abstract:OBJECTIVE:The aim of this study was to assess and compare the overall performance, reliability, variability, as well as the accuracy of diffusion tensor imaging (DTI) and fiber tracking metrics, for the muscles of the calf at 3 T and 7 T. MATERIALS AND METHODS:Ten volunteers (5 males; mean age, 29.1 ± 4.7 years), with...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0000000000000508
更新日期:2019-01-01 00:00:00
abstract:OBJECTIVE:As an imaging modality for follow-up during continuous or repeated hepatic arterial infusion chemotherapy using a hepatic intra-arterial indwelling catheter, the usefulness of CT while infusing contrast through the indwelling catheter (reservoir port) was examined. METHODS:Using reservoir ports implanted in ...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199912000-00003
更新日期:1999-12-01 00:00:00
abstract:PURPOSE:The aim of this study was to evaluate the feasibility of a prototype volume-interpolated breath-hold examination (VIBE) sequence using compressed sensing (VIBECS) for rapid multiphase arterial magnetic resonance imaging (MRI) at different temporal resolution during free-breathing in comparison with a convention...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0000000000000459
更新日期:2018-10-01 00:00:00
abstract:OBJECTIVES:The aim of this study was to investigate the impact of a novel iterative denoising and image enhancement technique in T1-weighted precontrast and postcontrast volume-interpolated breath-hold examination (VIBE) of the abdomen on image quality, noise levels, and diagnostic confidence without change of acquisit...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0000000000000746
更新日期:2020-11-18 00:00:00
abstract:RATIONALE AND OBJECTIVES:To compare the diagnostic efficacy of a standard dose of MRI contrast agent in the evaluation of primary brain tumors and metastases using a high-field 3 tesla MR unit versus a 1.5 tesla MR unit. METHODS:Sixteen patients with brain tumors were examined at both field strengths using identical a...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-200203000-00003
更新日期:2002-03-01 00:00:00