Abstract:
OBJECTIVES:The aim of this study was to compare F-fluorodeoxyglucose (FDG) positron emission tomography (PET)/magnetic resonance (MR) (with and without diffusion-weighted imaging [DWI]) to F-FDG PET/computed tomography (CT), with regard to the assessment of nodal and extranodal involvement, in patients with Hodgkin lymphoma and non-Hodgkin lymphoma, without restriction to FDG-avid subytpes. MATERIALS AND METHODS:Patients with histologically proven lymphoma were enrolled in this prospective, institutional review board-approved study. After a single F-FDG injection, patients consecutively underwent F-FDG PET[Fraction Slash]CT and F-FDG PET/MR on the same day for staging or restaging. Three sets of images were analyzed separately: F-FDG PET/CT, F-FDG PET/MR without DWI, and F-FDG PET/MR with DWI. Region-based agreement and examination-based sensitivity and specificity were calculated for F-FDG PET/CT, F-FDG PET/MR without DWI, and F-FDG PET/MR DWI. Maximum and mean standardized uptake values (SUVmax, SUVmean) on F-FDG PET/CT and F-FDG PET/MR were compared and correlated with minimum and mean apparent diffusion coefficients (ADCmin, ADCmean). RESULTS:Thirty-four patients with a total of 40 examinations were included. Examination-based sensitivities for F-FDG PET/CT, F-FDG PET/MR, and F-FDG PET/MR DWI were 82.1%, 85.7%, and 100%, respectively; specificities were 100% for all 3 techniques; and accuracies were 87.5%, 90%, and 100%, respectively. F-FDG PET/CT was false negative in 5 of 40 examinations (all with mucosa-associated lymphoid tissue lymphoma), and F-FDG PET/MR (without DWI) was false negative in 4 of 40 examinations. Region-based percentages of agreement were 99% (κ, 0.95) between F-FDG PET/MR DWI and F-FDG PET/CT, 99.2% (κ, 0.96) between F-FDG PET/MR and F-FDG PET/CT, and 99.4% (κ, 0.97) between F-FDG PET/MR DWI and F-FDG PET/MR. There was a strong correlation between F-FDG PET/CT and F-FDG PET/MR for SUVmax (r = 0.83) and SUVmean (r = 0.81) but no significant correlation between ADCmin and SUVmax (F-FDG PET/CT: r = 0.46, P = 0.65; F-FDG PET/MR: r = 0.64, P = 0.53) or between ADCmean and SUVmean (respectively, r = -0.14, P = 0.17 for the correlation with PET/CT and r = -0.14, P = 0.14 for the correlation with PET/MR). CONCLUSIONS:F-FDG PET/MR and F-FDG PET/CT show a similar diagnostic performance in lymphoma patients. However, if DWI is included in the F-FDG PET/MR protocol, results surpass those of F-FDG PET/CT because of the higher sensitivity of DWI for mucosa-associated lymphoid tissue lymphomas.
journal_name
Invest Radioljournal_title
Investigative radiologyauthors
Giraudo C,Raderer M,Karanikas G,Weber M,Kiesewetter B,Dolak W,Simonitsch-Klupp I,Mayerhoefer MEdoi
10.1097/RLI.0000000000000218subject
Has Abstractpub_date
2016-03-01 00:00:00pages
163-9issue
3eissn
0020-9996issn
1536-0210journal_volume
51pub_type
杂志文章abstract:RATIONALE AND OBJECTIVE:The authors performed a retrospective study in ultrasound to investigate new aspects in the sonomorphology of lymph node metastases of the neck. In this study, it could be demonstrated the first time that the histologic characteristics of the metastases determine the sonographic appearance. In a...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199609000-00001
更新日期:1996-09-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:The authors synthesized and tested a novel hydrogel system proposed for use in extra- and intravascular radiologic interventions, such as chemoembolizations and embolizations, and as a vehicle for sustained drug release. MATERIALS:The material was specifically designed to meet the prerequisite...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199312000-00001
更新日期:1993-12-01 00:00:00
abstract::Magnetic resonance (MR) methods have been used to study the metabolic and vascular response of model tumors to tumor necrosis factor (TNF). Magnetic resonance measurements demonstrated acute reductions in tumor blood flow, measured from tumor uptake of D2O, and in tumor adenosine triphosphate (ATP), measured by 31P ma...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198912000-00022
更新日期:1989-12-01 00:00:00
abstract::The large intestines of eight boxer dogs with canine histiocytic ulcerative colitis (CHUC) and 10 normal dogs were studied by in vivo angiography and postmortem microangiography. The vascular abnormalities were correlated with the gross and histologic pathology found at necropsy. The angiographic abnormalities were ...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-197505000-00005
更新日期:1975-05-01 00:00:00
abstract:OBJECTIVE:The aims of this study were to compare 3 contrast agents and to define feasible doses for quantitative lung perfusion imaging using the dual-bolus approach in dynamic contrast-enhanced (DCE) magnetic resonance imaging (MRI). MATERIALS AND METHODS:Ten healthy volunteers (6 males, 4 females; mean age, 23.5 yea...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0000000000000224
更新日期:2016-03-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:To assess the potential of magnetic resonance imaging (MRI) for evaluating the evolution of tumor necrosis, the authors evaluated 28 VX2 carcinomas inoculated in the thigh muscles of rabbits. METHODS:MRI of VX2 carcinomas at 2.0 T was done with spin-echo technique 1 week (14 tumors) and 3 week...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199301000-00010
更新日期:1993-01-01 00:00:00
abstract:PURPOSE:We aimed to determine whether diffusion-weighted magnetic resonance imaging, by means of the apparent diffusion coefficient (ADC), is able to guide magnetic resonance-guided biopsy in patients fit for active surveillance (AS) and identify patients harboring high-grade Gleason components not suitable for AS. MA...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0b013e31827b711e
更新日期:2013-03-01 00:00:00
abstract::A high-speed computed tomography (CT) scanner was used for measuring flow in a phantom and in the common carotid arteries of six dogs. The general ability of the scanner to assess flow using contrast media boluses was tested with the phantom. The validated simple concept was then used in the animals. The carotid blood...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198712000-00008
更新日期:1987-12-01 00:00:00
abstract:OBJECTIVES:The purpose of this study was to evaluate the extent to which various commercially available gadolinium-containing contrast-enhancing (CE) agents can interfere with the measurement of calcium levels by currently used laboratory methods, suggesting (spurious) hypocalcemia or hypercalcemia with a potential ris...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/01.rli.0000170447.45577.5e
更新日期:2005-08-01 00:00:00
abstract::Thoracic metastases from squamous carcinoma and adenocarcinoma of the cervix were studied by reviewing 245 consecutive cases to describe comparative incidence, natural history, and radiographic patterns. The incidence of chest metastases was higher for adenocarcinoma (20%) than for squamous carcinoma (4%). Few patient...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198003000-00004
更新日期:1980-03-01 00:00:00
abstract::A double-blind randomized study of ten patients compared Hexabrix 32% to Renografin-60 in TMJ arthrography. Equivalent volumes of contrast material were injected under fluoroscopic observation, with film quality and patient subjective response graded independently by three radiologists. In immediate arthrogram quality...
journal_title:Investigative radiology
pub_type: 临床试验,杂志文章
doi:10.1097/00004424-198411001-00032
更新日期:1984-11-01 00:00:00
abstract::A method of teaching radiology residents by identification of general and specific objectives to be accomplished during each time segment of the four-year training program has been developed. The objectives are incorporated into an educational contract that is signed by the resident and rotation director at the beginn...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198612000-00009
更新日期:1986-12-01 00:00:00
abstract::Proton magnetic resonance (MR) spectroscopy with homonuclear editing was used to assess lactate accumulation in ischemic and anoxic hearts perfused according to the Langendorff method. An increase in the lactate signal was observed after 5 minutes of ischemia and after 10 to 20 minutes of anoxia. This study demonstrat...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198708000-00004
更新日期:1987-08-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:The authors evaluate the use of a new device for interventional creation of atrial septal defects (ASD) working with high-frequency alternating current in an in vitro study with porcine atria. METHODS:The device consists of a symmetrical cage of six superelastic monofile wires, including a mic...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199702000-00003
更新日期:1997-02-01 00:00:00
abstract::A battery of tests for toxicity assessment of new contrast media is reviewed. Cell toxicity in a protozoan culture (Blepharisma americanum); lethal dose determination in mice; EEG Spectral analysis following cisternography in rabbits; ED50 and LD50 determination by intra- and pericerebral injection in rats; intraciste...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198011001-00053
更新日期:1980-11-01 00:00:00
abstract::A new technique for the noninvasive measurement of an index of renal blood flow is described. The method utilizes ultrasound determined renal volume and radionuclide assessment of the mean transit time of a pertechnetate bolus through the kidneys. From this information a value for flow is calculated according to compa...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198307000-00009
更新日期:1983-07-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:To demonstrate the usefulness of a model of the parenchymous vascularization to evaluate texture analysis methods. METHODS:Slices with thickness varying from 1 to 4 mm were reformatted from a 3D vascular model corresponding to either normal tissue perfusion or local hypervascularization. Param...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199903000-00004
更新日期:1999-03-01 00:00:00
abstract::We measured the amounts of three types of radiographic contrast media (RCM) that could be entrapped in liposomes prepared by the dehydration-rehydration vesicle (DRV) technique. To make DRVs, one initially makes water-containing, small unilamellar vesicles, adds contrast media and lyophilizes the mixture. Upon rehydra...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198802000-00009
更新日期:1988-02-01 00:00:00
abstract::The biliary and urinary excretion of sodium tyropanoate (Bilopaque) and sodium ipodate (Oragrafin) were studied in unanesthetized bile-fistula dogs using stepwise, increasing, intravenous infusions of the contrast materials. A constant intravenous infusion of sodium taurocholate was administered at the rate of either ...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-197701000-00017
更新日期:1977-01-01 00:00:00
abstract:OBJECTIVE:: This feasibility study was performed to assess whether dynamic contrast-enhanced ultrasound (CEUS) and transient arterial occlusion are able to detect alterations in the microvascular perfusion and arterial perfusion reserve in patients suffering from peripheral arterial disease (PAD) in comparison with hea...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0b013e3182183a77
更新日期:2011-08-01 00:00:00
abstract:OBJECTIVES:The objective of this study was to prospectively compare diagnostic performance and time efficiency of a double-reading paradigm in which a first-reader computer-aided detection (CAD) is followed by a fast 2-dimensional review (DR FR-CAD) with those of a double reading with second-reader CAD (SR CAD). MATER...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0000000000000009
更新日期:2014-03-01 00:00:00
abstract:OBJECTIVES:The objectives of this study were to assess the feasibility of magnetic resonance cholangiography (MRC) using biliary-secreted gadoxetic acid at 7 T and to compare it with T2-weighted (w) MRC at 3 T. MATERIALS AND METHODS:Ten healthy volunteers were examined on a 7-T whole-body magnetic resonance system. T2...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0000000000000004
更新日期:2014-05-01 00:00:00
abstract:OBJECTIVE:The aim of this study was to optimize computed tomography (CT) surveillance of skeletal metastases in patients with breast cancer through the use of osseous subtraction maps between baseline and follow-up examinations created by a novel software algorithm. The new postprocessing algorithm segments the origina...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0000000000000343
更新日期:2017-02-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:The authors developed a two-dimensional breathhold magnetic resonance (MR) technique for the direct imaging of pulmonary emboli. METHODS:In vitro MR imaging was performed to demonstrate the potential generation of clot-blood contrast by in vivo pulmonary embolism (PE). A two-dimensional magnet...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199708000-00001
更新日期:1997-08-01 00:00:00
abstract:OBJECTIVES:The aim of this study was to perform phantom measurements to prove the feasibility of single-source dual-energy computed tomography (DECT) of the extremities using a volume scan mode. In addition, we, for the first time, wanted to determine which concentrations of monosodium urate (MSU) in gout and calcium p...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0000000000000099
更新日期:2015-04-01 00:00:00
abstract:OBJECTIVES:The aims of this study were to investigate and validate quantitative susceptibility mapping (QSM) for lesional iron quantification in cerebral cavernous malformations (CCMs). MATERIALS AND METHODS:Magnetic resonance imaging studies were performed in phantoms and 16 patients on a 3-T scanner. Susceptibility ...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0000000000000043
更新日期:2014-07-01 00:00:00
abstract::The application of intravenous, intrathecal, and inhalation enhancement techniques to the CT evaluation of the nonhuman primate (Papio cynocephalus/anubis) is described. The falx cerebri cortical vasculature, vein of Galen, straight sinus and tentorium cerebelli were defined with intravenous enhancement. Intrathecal C...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-197901000-00014
更新日期:1979-01-01 00:00:00
abstract::A silicone gel phantom material is described. It can be molded into any shape and it can contain internal cavities. The material is selfsealing allowing the cavities to be filled with liquids. A simple geometric phantom consisting of a rectangular solid with a single internal spherical cavity was fabricated and imaged...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198702000-00013
更新日期:1987-02-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:We investigated whether it is possible to investigate degenerative changes in human tissue on a sub-100-microm resolution scale not only on special high-field small-bore MR-microscopy systems but also on a 3T whole-body MR-scanner. METHODS:Spin-spin relaxation, proton density, and diffusion mi...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/01.RLI.0000068620.17569.83
更新日期:2003-07-01 00:00:00
abstract::Video dilution technique (VDT) is currently performed in conjunction with routine cerebral angiography to determine carotid blood flow in humans. Preliminary results indicate that the blood flows (as a percentage of cardial output) of the common, internal, and external carotid arteries are 8.5%, 5.5%, and 3.0%, respec...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198105000-00004
更新日期:1981-05-01 00:00:00