Abstract:
RATIONALE AND OBJECTIVES:To assess the potential of magnetic resonance imaging (MRI) for evaluating the evolution of tumor necrosis, the authors evaluated 28 VX2 carcinomas inoculated in the thigh muscles of rabbits. METHODS:MRI of VX2 carcinomas at 2.0 T was done with spin-echo technique 1 week (14 tumors) and 3 weeks (14 tumors) after the inoculation of tumor cells. T1- and T2-weighted images were obtained with 500/30 and 2,500/80 sequences; the authors also performed enhanced T1-weighted images with contrast medium. MRI and histopathologic findings were compared. RESULTS:Enhanced T1-weighted images with gadolinium-DTPA (Gd-DTPA) (dimeglumine gadopentetate) could depict necrosis in almost all tumors (27/28) and were the most sensitive technique followed by T2- and T1-weighted images. T2-weighted images best permitted the evaluation of the characteristics of necrotic areas in VX2 carcinomas, followed by T1-weighted images with contrast enhancement, and unenhanced T1-weighted images. On T2-weighted images, low-intensity areas of necrotic areas correspond to areas of early necrosis, isointense areas corresponded to areas of intermediate necrosis, and high-intensity areas corresponded to the late phase of necrosis. CONCLUSIONS:MRI is useful in depicting necrosis and characterizing different phases of necrosis in VX2 carcinomas.
journal_name
Invest Radioljournal_title
Investigative radiologyauthors
Choi BI,Lee DH,Han MCdoi
10.1097/00004424-199301000-00010subject
Has Abstractpub_date
1993-01-01 00:00:00pages
33-8issue
1eissn
0020-9996issn
1536-0210journal_volume
28pub_type
杂志文章abstract:RATIONALE AND OBJECTIVES:Because of the complex relationships between the dynamic three-dimensional cardiac surface shape and its projected image, errors arise with the use of two-dimensional silhouettes to measure displacements of the heart. The character and frequency of such errors are examined. METHODS:A high-prec...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199403000-00004
更新日期:1994-03-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:To characterize the long-term effects of therapeutic doses of ionizing radiation on the uptake and distribution of percutaneously delivered particulate contrast media in normal lymph nodes. METHODS:Two milliliters of an iodinated nanoparticle suspension (76 mg I/mL) was injected subcutaneously...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-200003000-00007
更新日期:2000-03-01 00:00:00
abstract::Comparatively new in the roentgen evaluation of infants and children, xerography would appear to be ideal for portraying the pediatric airway. Since the radiation dose of xerography is higher than conventional radiography, its image quality is the subject of careful scrutiny in a pediatric setting here described in 23...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-197807000-00002
更新日期:1978-07-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:Dynamic contrast enhanced (DCE) MR mammography (MRM) uses tumor capillary density differences for prognosis. The heterogeneous response of permeability-surface area products (PS = Kp<-->t) was examined in mammary tumors, as a function of contrast agent size, to determine what effect ROI size mi...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-200204000-00003
更新日期:2002-04-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:The author analyzes findings of consistency of rotator-cuff calcifications found at ultrasound (US)-guided needle treatment compared with findings of plain radiography, US, and computed tomography (CT). METHODS:Twenty patients had rotator-cuff calcifications (mean diameter, 1.5 cm; range, 1.1-...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199605000-00010
更新日期:1996-05-01 00:00:00
abstract::A method is presented by whichcomputed tomography scans carried out at a number of energies may be utilized to obtain cross-sectional images of density and atomic number in addition to the conventional array of linear attenuation coefficients. This type of analysis has been carried out for various substances of biolog...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-197703000-00016
更新日期:1977-03-01 00:00:00
abstract:OBJECTIVES:Ferumoxytol, an intravenous iron supplement, can be used in off-label mode as a contrast agent in magnetic resonance imaging. The aim of this study was to assess whether ferumoxytol can be used as a marker of inflammation in animal models of acute and chronic inflammatory kidney diseases. MATERIAL AND METHO...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0000000000000209
更新日期:2016-02-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:To evaluate the imaging characteristics of various iliac artery stents and stent-grafts in a multislice, computed tomography angiography (MSCTA) phantom study. METHODS:Twelve types of stents and three stent-grafts made of different materials (steel, nitinol, tantalum, cobalt-based alloy) were ...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-200112000-00004
更新日期:2001-12-01 00:00:00
abstract::A new technique for the noninvasive measurement of an index of renal blood flow is described. The method utilizes ultrasound determined renal volume and radionuclide assessment of the mean transit time of a pertechnetate bolus through the kidneys. From this information a value for flow is calculated according to compa...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198307000-00009
更新日期:1983-07-01 00:00:00
abstract::Urine samples were collected from 200 subjects undergoing intravenous pyelography. The urine histamine levels were compared with those of 132 normal control subjects, 11 subjects with systemic mastocytosis, six subjects with idiopathic anaphylaxis, and ten subjects experiencing mild anaphylactic reactions during aller...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198403000-00007
更新日期:1984-03-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:To evaluate the safety and pharmacokinetics of a newly developed MR contrast medium consisting of very small superparamagnetic iron oxide particles (VSOP) coated with citrate (VSOP-C184) in a clinical phase I trial. METHODS:A total of 18 healthy subjects received either VSOP-C184 (core diamete...
journal_title:Investigative radiology
pub_type: 临床试验,杂志文章,随机对照试验
doi:10.1097/01.rli.0000129472.45832.b0
更新日期:2004-07-01 00:00:00
abstract:OBJECTIVE:The objective of this study was to evaluate a high spatial resolution 3-dimensional (3D) contrast-enhanced magnetic resonance (CE-MR) venography protocol for evaluation of intracranial venous system using highly accelerated parallel imaging at 3.0 T. MATERIALS AND METHODS:Ten patients (4 male, 6 female; age,...
journal_title:Investigative radiology
pub_type: 临床试验,杂志文章
doi:10.1097/01.rli.0000236992.21065.04
更新日期:2006-10-01 00:00:00
abstract:OBJECTIVES:The aim of this study was to assess the effectiveness of a model-based iterative reconstruction (MBIR) in improving image quality and diagnostic performance of ultralow-dose computed tomography (ULDCT) of the lung. MATERIALS AND METHODS:The institutional review board approved this study, and all patients pr...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0b013e3182562a89
更新日期:2012-08-01 00:00:00
abstract::Due to the nature of three-dimensional Fourier transform (3-DFT) data acquisition in magnetic resonance imaging (MRI), the spatial relation between a resolved volume element (a voxel) and the object can be manipulated easily. Those manipulations have practical consequences in terms of registering slice positions with ...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199012000-00006
更新日期:1990-12-01 00:00:00
abstract:OBJECTIVES:The purpose of this study was to evaluate the extent to which various commercially available gadolinium-containing contrast-enhancing (CE) agents can interfere with the measurement of calcium levels by currently used laboratory methods, suggesting (spurious) hypocalcemia or hypercalcemia with a potential ris...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/01.rli.0000170447.45577.5e
更新日期:2005-08-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:To analyze changes in Doppler ultrasound variables of the portal vein in relation to liver biopsy findings, the authors performed a prospective study of 316 Doppler ultrasound examinations in the first 2 weeks after orthotopic liver transplantation on 23 patients. METHODS:Recordings were obtai...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199612000-00007
更新日期:1996-12-01 00:00:00
abstract:OBJECTIVES:Volumetric magnetic resonance (MR)-guided high-intensity focused ultrasound (HIFU) is a completely noninvasive image-guided thermal ablation technique. Recently, there has been growing interest in the use of MR-HIFU for noninvasive ablation of malignant tumors. Of particular interest for noninvasive ablation...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0b013e3182820257
更新日期:2013-06-01 00:00:00
abstract::Human gallstones were surgically placed into the gallbladders of 200 swine. Eight of these swine were used as a prospective series to verify that the placement and presence of human gallstones in their gallbladders caused no significant pathologic changes in the gallbladder and that the gallstones were not spontaneous...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198902000-00005
更新日期:1989-02-01 00:00:00
abstract:OBJECTIVES:The aim of this study was to investigate the feasibility of nonenhanced magnetic resonance angiography (MRA) of the lower extremities at 7 tesla (T). MATERIALS AND METHODS:Eight healthy volunteers were examined on a 7-T whole-body magnetic resonance system. For image acquisition, a custom-built 16-channel t...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0b013e3182839c2b
更新日期:2013-07-01 00:00:00
abstract:OBJECTIVES:The aim of this study was to evaluate the effect of structured reports (SRs) in comparison to nonstructured, free-text (FT) rectal magnetic resonance imaging (MRI) reports in patients with histologically proven rectal cancer and potential effects of both types of reporting on referring surgeons' satisfaction...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0000000000000336
更新日期:2017-04-01 00:00:00
abstract::Lymphangiograms of canine cardiac and pulmonary efferent mediastinal lymphatics were made by cannulation and injection of Ethiodol. Injections were made singly and serially. The mediastinal lymphatics and lymph nodes, which constitute the pathways of drainage of the heart and lungs, were delineated from the point of c...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-197901000-00012
更新日期:1979-01-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:The authors investigated whether the ability of human malignant melanoma cells to increase in cell number or their ability to remain viable was compromised by high-field strength static magnetic fields. Normal human fibroblasts also were studied to determine if any magnetic field-related altera...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199210000-00014
更新日期:1992-10-01 00:00:00
abstract:OBJECTIVE:There is little published information regarding the efficacy of paclitaxel-coated balloon catheters except for the iopromide-containing formulation, and less is known about the kind of toxicity at overdose. The aim of our study was to assess 2 different paclitaxel matrix formulations on angioplasty balloon ca...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0b013e31820577df
更新日期:2011-04-01 00:00:00
abstract::Flow measurements can be made with computed tomography (CT) scanners using iodinated, nonionic contrast media as a first-pass indicator. Ultrafast CT (UFCT) is an ideal machine to make these measurements because of its short scan time (50 mseconds) and interscan delay (< or = 0.6 seconds). Additionally, UFCT can acqui...
journal_title:Investigative radiology
pub_type: 杂志文章,评审
doi:10.1097/00004424-199212002-00004
更新日期:1992-12-01 00:00:00
abstract:OBJECTIVES:To evaluate the performance of black-blood diffusion-weighted (DW)-EPI sequences with parallel imaging for the detection of focal liver lesions in comparison with a standard T2-weighted (T2-w) sequence. MATERIALS AND METHODS:Twenty patients with known or suspected focal liver lesions underwent liver MRI usi...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0b013e31816200b5
更新日期:2008-04-01 00:00:00
abstract::The extent to which various concentrations of the paramagnetic metal ions [gadolinium (III), manganese (II), chromium (III), iron (III), nickel (II), copper (II), and cobalt (II)] affect proton magnetic relaxation times of distilled water, 4% human serum albumin (HSA), and dog plasma was studied in vitro. The pH of wa...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198602000-00009
更新日期:1986-02-01 00:00:00
abstract:OBJECTIVES:In late December 2019, an outbreak of coronavirus disease (COVID-19) in Wuhan, China was caused by a novel coronavirus, newly named severe acute respiratory syndrome coronavirus 2. We aimed to quantify the severity of COVID-19 infection on high-resolution chest computed tomography (CT) and to determine its r...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0000000000000674
更新日期:2020-06-01 00:00:00
abstract:OBJECTIVES:To test the feasibility of a single MR-based examination allowing for the comprehensive assessment of renal anatomy, function, and vascular status in candidates for kidney transplantation. MATERIALS AND METHODS:Twelve healthy potential kidney donors (mean age: 47 +/- 14 [standard deviation] years, 3 men and...
journal_title:Investigative radiology
pub_type: 临床试验,杂志文章
doi:10.1097/RLI.0b013e3181b35a70
更新日期:2009-11-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:To study cellular mechanisms that cause contrast media nephropathy, an in vitro system for proximal and distal tubular cells has been established to evaluate the influence of x-ray contrast media on tubular function. METHODS:Confluent cell cultures of the two renal cell lines, proximal tubule ...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199411000-00002
更新日期:1994-11-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:Magnetic resonance imaging (MRI) techniques seem to be very promising for 3D dosimetry studies, but long imaging acquisition time limits their use. A new fast T1 mapping protocol, easy to implement on a conventional MR imager, has been used to determine dose distributions on Fricke gels. METHO...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199903000-00014
更新日期:1999-03-01 00:00:00