Detection and characterization of crystal suspensions using single-source dual-energy computed tomography: a phantom model of crystal arthropathies.

Abstract:

OBJECTIVES:The aim of this study was to perform phantom measurements to prove the feasibility of single-source dual-energy computed tomography (DECT) of the extremities using a volume scan mode. In addition, we, for the first time, wanted to determine which concentrations of monosodium urate (MSU) in gout and calcium pyrophosphate (CP) in pseudogout are needed to detect or distinguish these soft tissue depositions with DECT. MATERIALS AND METHODS:We created a hand-shaped plastic phantom assembled with a descending order of concentrations of MSU (6.25%-50%) and CP (1.56%-50%) with similar attenuation in conventional computed tomographic (CT) images. Dual-energy imaging was done on a standard 320-row CT scanner with acquisition of 2 volumes: one at 80 and the other at 135 kV. Using linear regression analysis, dual-energy gradients were calculated for MSU and CP. Thereafter, we selected a specific region of interest on the dual-energy graph to color-code MSU and CP on the images. Three blinded readers scored 10 scans of the randomly equipped phantom, corresponding to 60 samples, to determine the sensitivity and specificity of this technique. Receiver operating characteristics analysis was done to determine the diagnostic power. RESULTS:We found a dual-energy gradient for MSU of 1.020 ± 0.006 and for CP of 0.673 ± 0.001. Assessment of the randomized phantom scans indicates reliable detection of MSU at concentrations of 12.5 % or higher and that of CP at 6.25 % or higher, corresponding to deposits with mean Hounsfield unit values of 59.8 for MSU and 101.1 for CP. The sensitivity for MSU ranged from 83.3% to 97.3% at 15/90 mA (135/80 kV) and from 86.7% to 97.3% at 100/570 mA. Specificity was 96.7% to 100% in 15/90 mA and 100% in 100/570 mA of scans. However, there was inferior sensitivity for CP owing to lower concentrations. In the receiver operating characteristics analysis, the area under the curve for MSU ranged from 0.867 to 0.947 at 15/90 mA and from 0.867 to 0.919 at 100/570 mA and that for CP from 0.659 to 0.745 and from 0.718 to 0.750, respectively. CONCLUSIONS:This phantom study shows that single-source DECT allows detection and characterization of crystal deposits when present in soft tissue at relatively low concentrations. Further studies in patients have to prove its benefits in diagnostic imaging and treatment monitoring as well as its significance compared with dual-source CT systems.

journal_name

Invest Radiol

journal_title

Investigative radiology

authors

Diekhoff T,Kiefer T,Stroux A,Pilhofer I,Juran R,Mews J,Blobel J,Tsuyuki M,Ackermann B,Hamm B,Hermann KG

doi

10.1097/RLI.0000000000000099

subject

Has Abstract

pub_date

2015-04-01 00:00:00

pages

255-60

issue

4

eissn

0020-9996

issn

1536-0210

journal_volume

50

pub_type

杂志文章
  • Direct video-microscopic observation of the dynamic effects of medical ultrasound on ultrasound contrast microspheres.

    abstract:RATIONALE AND OBJECTIVES:Ultrasound can cause destruction of microbubble contrast agents used to enhance medical ultrasound imaging. This study sought to characterize the dynamics of this interaction by direct visual observation of microbubbles during insonification in vitro by a medical ultrasound imaging system. MET...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199812000-00004

    authors: Klibanov AL,Ferrara KW,Hughes MS,Wible JH Jr,Wojdyla JK,Dayton PA,Morgan KE,Brandenburger GH

    更新日期:1998-12-01 00:00:00

  • Magnetic resonance evaluation of regional left ventricular function. Effect of through-plane motion.

    abstract:RATIONALE AND OBJECTIVES:Measurements of segmental contraction of the left ventricle by standard magnetic resonance imaging (MRI) and two-dimensional echocardiography involve the comparison of diastolic and systolic time frames acquired from the same imaging plane in space. As the cone-shaped left ventricle shortens al...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199209000-00004

    authors: Pattynama PM,Doornbos J,Hermans J,van der Wall EE,de Roos A

    更新日期:1992-09-01 00:00:00

  • Quantitative evaluation of perfusion and permeability of peripheral tumors using contrast-enhanced computed tomography.

    abstract:RATIONALE AND OBJECTIVES:Our purpose was to validate contrast-enhanced computed tomography (CECT)-derived quantitative measures of perfusion and permeability against gold standard techniques of fluorescent microspheres and Evan's Blue dye, respectively. MATERIALS AND METHODS:Normal and tumor-bearing (R3230AC) Fischer ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/01rli.0000124456.82985.35

    authors: Pollard RE,Garcia TC,Stieger SM,Ferrara KW,Sadlowski AR,Wisner ER

    更新日期:2004-06-01 00:00:00

  • Effect of Age on High T1 Signal Intensity of the Dentate Nucleus and Globus Pallidus in a Large Population Exposed to Gadodiamide.

    abstract:OBJECTIVE:The purpose of this study was to assess the effect of age and number of previous injections of gadodiamide on the signal intensity of unenhanced T1-weighted (T1w) images of the dentate nucleus and globus pallidus in a large population. MATERIALS AND METHODS:A large, single-center retrospective population sur...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000431

    authors: Quattrocchi CC,Errante Y,Mallio CA,Marinelli L,LoVullo G,Giannotti G,Della Sala SW,van der Molen AJ,Beomonte Zobel B

    更新日期:2018-04-01 00:00:00

  • Iopamidol as a gastrointestinal contrast agent. Lack of peritoneal reactivity.

    abstract::The ideal contrast agent in patients suspected of having gastrointestinal perforation is an iso-osmolar, or nearly iso-osmolar substance, that causes no peritoneal reaction. Iopamidol is a nonionic water-soluble contrast medium that may be considered in such situations. Intraperitoneal injections of ionic and nonionic...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199002000-00008

    authors: Ferrante SL,Schreiman JS,Rouse JW,Rysavy JA,Cheng SC,Frick MP

    更新日期:1990-02-01 00:00:00

  • Comparison of left ventricular ejection fraction and regional contractility fraction pre and post coronary angiography.

    abstract::Thirty patients [four normals, eight with mild and 18 with severe coronary artery disease (CAD)] were studied to evaluate left ventricular function type and post coronary angiography. The end diastolic volume (EDV), end systolic volume (ESV), ejection fraction (EF) and the regional contractility fractions (RCF) of eig...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-197603000-00009

    authors: Sos TA,Baltaxe HA

    更新日期:1976-03-01 00:00:00

  • Nephrogenic systemic fibrosis in patients with chronic kidney disease who received gadopentetate dimeglumine.

    abstract:OBJECTIVE:To determine the prevalence of nephrogenic systemic fibrosis (NSF) in patients with chronic kidney disease (CKD) who have received gadopentetate dimeglumine. MATERIALS AND METHODS:We retrospectively studied all patients who underwent contrast-enhanced magnetic resonance imagings (CE-MRIs) between January 1, ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e31819343ba

    authors: Hope TA,Herfkens RJ,Denianke KS,LeBoit PE,Hung YY,Weil E

    更新日期:2009-03-01 00:00:00

  • Preclinical profile of the monodisperse iodinated macromolecular blood pool agent P743.

    abstract:RATIONALE AND OBJECTIVES:To summarize the chemical synthesis, physicochemical characterization, pharmacokinetic behavior, and biological evaluation of P743, a new macromolecular iodinated contrast medium. METHODS:The synthesis and molecular modeling of the iodinated macromolecule P743 are described. The pharmacokineti...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-200101000-00006

    authors: Idée JM,Port M,Robert P,Raynal I,Prigent P,Dencausse A,Le Greneur S,Tichkowsky I,Le Lem G,Bourrinet P,Mugel T,Benderbous S,Devoldere L,Bourbouze R,Meyer D,Bonnemain B,Corot C

    更新日期:2001-01-01 00:00:00

  • Facilitated Diagnosis of Pneumothoraces in Newborn Mice Using X-ray Dark-Field Radiography.

    abstract:OBJECTIVE:The aim of this study was to evaluate the diagnostic value of x-ray dark-field imaging in projection radiography-based depiction of pneumothoraces in the neonatal murine lung, a potentially life-threatening medical condition that requires a timely and correct diagnosis. MATERIALS AND METHODS:By the use of a ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000285

    authors: Hellbach K,Yaroshenko A,Willer K,Pritzke T,Baumann A,Hesse N,Auweter S,Reiser MF,Eickelberg O,Pfeiffer F,Hilgendorff A,Meinel FG

    更新日期:2016-10-01 00:00:00

  • Evaluation of neuroendocrine liver metastases: a comparison of dynamic contrast-enhanced magnetic resonance imaging and positron emission tomography/computed tomography.

    abstract:OBJECTIVES:The objective of this study was to evaluate the correlation between dynamic gadoxetic acid-enhanced magnetic resonance imaging parameters and specific uptake values (SUVs) derived from ¹⁸fluorodeoxyglucose (¹⁸F-FDG) and ⁶⁸Ga-DOTA-Tyr(3)-octreotate (⁶⁸Ga-DOTATATE) positron emission tomography/computed tomogra...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e3182a4eb4a

    authors: Armbruster M,Sourbron S,Haug A,Zech CJ,Ingrisch M,Auernhammer CJ,Nikolaou K,Paprottka PM,Rist C,Reiser MF,Sommer WH

    更新日期:2014-01-01 00:00:00

  • Mechanism of hepatic parenchyma-specific contrast of microbubble-based contrast agent for ultrasonography: microscopic studies in rat liver.

    abstract:OBJECTIVE:The objective of this study was to elucidate the mechanism of hepatic parenchyma-specific contrast of Sonazoid (microbubble contrast agent) using microscopic techniques. MATERIALS AND METHODS:Sonazoid was intravenously injected into rats to investigate the microbubble dynamics and distribution within hepatic...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e31805f2682

    authors: Watanabe R,Matsumura M,Munemasa T,Fujimaki M,Suematsu M

    更新日期:2007-09-01 00:00:00

  • The use of continuous and discrete confidence judgments in receiver operating characteristic studies of diagnostic imaging techniques.

    abstract::Virtually all receiver operating characteristic (ROC) studies of medical imaging methods have involved data collected on a discrete confidence-rating scale, though in principle ROC studies can be conducted with either discrete or continuous scales. Continuous scales provide potential advantages in medical applications...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199202000-00016

    authors: Rockette HE,Gur D,Metz CE

    更新日期:1992-02-01 00:00:00

  • Observer variation in detecting the radiologic features associated with bronchiolitis.

    abstract::Chest radiographs are commonly obtained to assess children for bronchiolitis, both to corroborate the diagnosis and to exclude other diagnostic possibilities. Their utility in this setting has not previously been examined. Using a blinded, randomized study design, we examined the interobserver and intraobserver variat...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199102000-00004

    authors: Coblentz CL,Babcook CJ,Alton D,Riley BJ,Norman G

    更新日期:1991-02-01 00:00:00

  • Evaluation of diffusion-weighted MR imaging at inclusion in an active surveillance protocol for low-risk prostate cancer.

    abstract:PURPOSE:We aimed to determine whether diffusion-weighted magnetic resonance imaging, by means of the apparent diffusion coefficient (ADC), is able to guide magnetic resonance-guided biopsy in patients fit for active surveillance (AS) and identify patients harboring high-grade Gleason components not suitable for AS. MA...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e31827b711e

    authors: Somford DM,Hoeks CM,Hulsbergen-van de Kaa CA,Hambrock T,Fütterer JJ,Witjes JA,Bangma CH,Vergunst H,Smits GA,Oddens JR,van Oort IM,Barentsz JO,MR-PRIAS Collaboration Group.

    更新日期:2013-03-01 00:00:00

  • Interventional atrioseptostomy by application of monopolar high-frequency alternating current. In vitro evaluation of a new device.

    abstract:RATIONALE AND OBJECTIVES:The authors evaluate the use of a new device for interventional creation of atrial septal defects (ASD) working with high-frequency alternating current in an in vitro study with porcine atria. METHODS:The device consists of a symmetrical cage of six superelastic monofile wires, including a mic...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199702000-00003

    authors: Grabitz RG,Handt S,Vanopbroeke HJ,Seghaye MC,Franke A,Osypka P,von Bernuth G

    更新日期:1997-02-01 00:00:00

  • A new class of contrast agents for magnetic resonance imaging based on selective reduction of water-T2 by chemical exchange.

    abstract::Compounds containing mobile protons can act as contrast agents by increasing the value of the term (1/12 - 1/11). The efficiency of this method is markedly pH- and field-dependent. There are many such compounds allowing a choice to be made based on the characteristics of the tissue or organ, magnetic field strength, a...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198809001-00058

    authors: Aime S,Nano R,Grandi M

    更新日期:1988-09-01 00:00:00

  • Radiologic-pathologic-clinical correlation in mechanisms of disease course.

    abstract::The interdisciplinary approach to medical education has often been deficient in medical school curricula. Because of the nonintegrated approach to medical education, problem solving capabilities are not fostered. The clinical presentation of a patient, the imaging modalities used to investigate the patient, and the ul...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198604000-00015

    authors: Oldham SA,Jacobson F

    更新日期:1986-04-01 00:00:00

  • Establishing Reference Intervals for Gadolinium Concentrations in Blood, Plasma, and Urine in Individuals Not Previously Exposed to Gadolinium-Based Contrast Agents.

    abstract:OBJECTIVES:Over the recent years, there have been increasing concerns that exposure to gadolinium-based contrast agents (GBCAs) may be associated with retention of Gd within the skin, bones, and solid organs in patients with normal renal function, although the clinical implications of this deposition remain to be estab...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000657

    authors: Layne KA,Wood DM,Dixon-Zegeye M,Archer JRH,Raja K,Dargan PI

    更新日期:2020-07-01 00:00:00

  • The radiation dosimetry and normal value study of 99mTc-HMPAO-labeled leukocytes.

    abstract:RATIONALE AND OBJECTIVES:Indium-111 (111In)-labeled leukocyte scanning has been used frequently in patients suspected of having infections. Recently, technetium-99m hexamethylpropylene amine oxime (99mTc-HMPAO) has been used to label leukocytes. This study was undertaken to determine the distribution and dosimetry of 9...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199404000-00010

    authors: Brown ML,Hung JC,Vetter RJ,O'Connor MK,Chowdhury S,Forstrom LA

    更新日期:1994-04-01 00:00:00

  • Low-dose spiral computed tomography of the thorax: comparison with the standard-dose technique.

    abstract:RATIONALE AND OBJECTIVES:This study was conducted to determine whether significant reduction in radiation dose (250 mAs-->50 mAs), in chest computed tomography (CT) using volume acquisition affects image quality or the detectability of pathologic findings in the lung and mediastinum. METHODS:Phantom studies were condu...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199802000-00002

    authors: Takahashi M,Maguire WM,Ashtari M,Khan A,Papp Z,Alberico R,Campbell W,Eacobacci T,Herman PG

    更新日期:1998-02-01 00:00:00

  • Altered cerebrovenous drainage in patients with migraine as assessed by phase-contrast magnetic resonance imaging.

    abstract:OBJECTIVE:We aimed to assess whether migraine is associated with changes in the distribution of the venous drainage through primary and secondary pathways by using phase-contrast magnetic resonance imaging (MRI). METHODS:We examined 26 patients (37.3 ± 13.9 years) with recurring migraine headaches and 26 age- and gend...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e318210ecf5

    authors: Koerte IK,Schankin CJ,Immler S,Lee S,Laubender RP,Grosse C,Eftimov L,Milde-Busch A,Reiser M,Straube A,Heinen F,Alperin N,Ertl-Wagner B

    更新日期:2011-07-01 00:00:00

  • Continuous Hepatic Arterial Multiphase Magnetic Resonance Imaging During Free-Breathing.

    abstract:PURPOSE:The aim of this study was to evaluate the feasibility of a prototype volume-interpolated breath-hold examination (VIBE) sequence using compressed sensing (VIBECS) for rapid multiphase arterial magnetic resonance imaging (MRI) at different temporal resolution during free-breathing in comparison with a convention...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000459

    authors: Weiss J,Notohamiprodjo M,Taron J,Martirosian P,Nickel D,Bamberg F,Nikolaou K,Othman AE

    更新日期:2018-10-01 00:00:00

  • Automated calibration in vascular X-ray images using the accurate localization of catheter marker bands.

    abstract:RATIONALE AND OBJECTIVES:To develop a new automated calibration method for vessel measurements in vascular x-ray images. METHODS:Radiopaque marker bands mounted equidistantly on a small catheter were acquired in vitro at five image intensifier (II) sizes in x-ray projection images. The positions of the marker centers ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-200004000-00002

    authors: Van Assen HC,Vrooman HA,Egmont-Petersen M,Bosch HG,Koning G,Van Der Linden EL,Goedhart B,Reiber JH

    更新日期:2000-04-01 00:00:00

  • Keratinization and necrosis. Morphologic aspects of lymphatic metastases in ultrasound.

    abstract:RATIONALE AND OBJECTIVE:The authors performed a retrospective study in ultrasound to investigate new aspects in the sonomorphology of lymph node metastases of the neck. In this study, it could be demonstrated the first time that the histologic characteristics of the metastases determine the sonographic appearance. In a...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199609000-00001

    authors: Mäurer J,Willam C,Steinkamp HJ,Knollmann FD,Felix R

    更新日期:1996-09-01 00:00:00

  • Long-term effect of irradiation on lymph node uptake of interstitially delivered nanoparticulate contrast media.

    abstract:RATIONALE AND OBJECTIVES:To characterize the long-term effects of therapeutic doses of ionizing radiation on the uptake and distribution of percutaneously delivered particulate contrast media in normal lymph nodes. METHODS:Two milliliters of an iodinated nanoparticle suspension (76 mg I/mL) was injected subcutaneously...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-200003000-00007

    authors: Wisner ER,Théon A,Griffey SM,McIntire GL

    更新日期:2000-03-01 00:00:00

  • Development and evaluation of a phantom for dynamic contrast-enhanced imaging.

    abstract:OBJECTIVES:Dynamic contrast-enhanced imaging allows assessing functional information in addition to morphology using various modalities. Several applications have been established in clinical practice; however, there is no standard with respect to injection protocols or postprocessing algorithms. The purpose of this st...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e318250a72c

    authors: Brauweiler R,Eisa F,Hupfer M,Nowak T,Kolditz D,Kalender WA

    更新日期:2012-08-01 00:00:00

  • Hepatocellular carcinoma: correlation between vascular endothelial growth factor level and degree of enhancement by multiphase contrast-enhanced computed tomography.

    abstract:RATIONALE AND OBJECTIVES:To determine whether vascular endothelial growth factor (VEGF) is a histopathological factor influencing contrast enhancement of hepatocellular carcinoma (HCC) on computed tomography (CT). METHODS:Twenty-two nodular HCCs underwent multiphase helical CT and surgery. Tumor size, histological gra...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-200108000-00008

    authors: Kwak BK,Shim HJ,Park ES,Kim SA,Choi D,Lim HK,Park CK,Chung JW,Park JH

    更新日期:2001-08-01 00:00:00

  • Effect of intraarticular pressure on patellar position. Computed tomography study in cadaveric specimens.

    abstract:RATIONALE AND OBJECTIVES:The purpose of the study was to evaluate the effect of articular fluid distention on patellar position at different degrees of knee angulation. METHODS:Patellar position in 10 cadaveric knee specimens was determined with 30, 100, and 200 mm Hg joint distention at 45, 20, and 5 degrees of knee ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199602000-00001

    authors: Brossmann J,Koch S,Schwarzenberg H,Link J,Muhle C,Bull CC,Heller M

    更新日期:1996-02-01 00:00:00

  • Reflux of ethanol during experimental liver ethanol injections.

    abstract:RATIONALE AND OBJECTIVES:The reflux of ethanol into the peritoneal cavity during percutaneous ethanol injection therapy (PEIT) of liver neoplasms may cause pain and other side effects. This article studies the optimal injection technique to minimize the reflux of ethanol. METHODS:A technique using normal postmortem pi...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199211000-00008

    authors: Vehmas T

    更新日期:1992-11-01 00:00:00

  • Sclerotherapy of the gallbladder in pigs. Development of a balloon catheter for a single-step procedure.

    abstract::Gallbladder sclerotherapy after permanent cystic duct occlusion, to prevent gallstone recurrence in nonsurgical gallstone therapy, is at least a two-stage procedure. A balloon catheter was developed to perform gallbladder sclerotherapy with only temporary occlusion of the cystic duct, and the efficacy and safety of th...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199109000-00005

    authors: Brakel K,Laméris JS,Vergunst H,Ten Kate FJ,Nijs HG,Terpstra OT

    更新日期:1991-09-01 00:00:00