Comparison of left ventricular ejection fraction and regional contractility fraction pre and post coronary angiography.

Abstract:

:Thirty patients [four normals, eight with mild and 18 with severe coronary artery disease (CAD)] were studied to evaluate left ventricular function type and post coronary angiography. The end diastolic volume (EDV), end systolic volume (ESV), ejection fraction (EF) and the regional contractility fractions (RCF) of eight ventricular segments were evaluated by left ventriculography. The RCF's were analyzed, in addition to the EF's to ascertain the effect of contrast material upon normal and scarred or ischemic segments of the left ventricle, and to rule out spurious findings in the EF due to coexistent reciprocal changes in RCF's. There was good correlation (r = .45 to .97 and p less than .01 to less than .001) in the above parameters of left ventricular function in patients with and without CAD before and after angiography. Thus, although intraventricular and intracoronary injections of contrast material produce transient changes in myocardial contractility, in a clinical setting left ventriculography may be performed prior to or following coronary angiography without danger of spurious results in normals and in patients with CAD.

journal_name

Invest Radiol

journal_title

Investigative radiology

authors

Sos TA,Baltaxe HA

doi

10.1097/00004424-197603000-00009

keywords:

subject

Has Abstract

pub_date

1976-03-01 00:00:00

pages

138-45

issue

2

eissn

0020-9996

issn

1536-0210

journal_volume

11

pub_type

杂志文章
  • Detection and characterization of crystal suspensions using single-source dual-energy computed tomography: a phantom model of crystal arthropathies.

    abstract:OBJECTIVES:The aim of this study was to perform phantom measurements to prove the feasibility of single-source dual-energy computed tomography (DECT) of the extremities using a volume scan mode. In addition, we, for the first time, wanted to determine which concentrations of monosodium urate (MSU) in gout and calcium p...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000099

    authors: Diekhoff T,Kiefer T,Stroux A,Pilhofer I,Juran R,Mews J,Blobel J,Tsuyuki M,Ackermann B,Hamm B,Hermann KG

    更新日期:2015-04-01 00:00:00

  • Magnetic resonance imaging-guided percutaneous biopsy of mediastinal masses: diagnostic performance and safety.

    abstract:OBJECTIVE:The objective of this study was to evaluate the diagnostic performance and safety of magnetic resonance (MR) imaging-guided percutaneous mediastinal biopsy procedures using a 0.23-T open MR system with optical tracking navigation. MATERIALS AND METHODS:A retrospective analysis of 59 participants (38 males an...

    journal_title:Investigative radiology

    pub_type: 临床试验,杂志文章

    doi:10.1097/RLI.0b013e31827a4a17

    authors: Lü Y,Fritz J,Li C,Liu M,Lee P,Wu L,Carrino JA

    更新日期:2013-06-01 00:00:00

  • Analysis of edge-tracking errors inherent in fluoroscopic images of the beating heart.

    abstract:RATIONALE AND OBJECTIVES:Because of the complex relationships between the dynamic three-dimensional cardiac surface shape and its projected image, errors arise with the use of two-dimensional silhouettes to measure displacements of the heart. The character and frequency of such errors are examined. METHODS:A high-prec...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199403000-00004

    authors: McInerney JJ,Weldner PW,Herr MD,Copenhaver GL

    更新日期:1994-03-01 00:00:00

  • Hepatic parenchymal changes after the intraarterial injection of lipiodol in tumor-bearing rabbits.

    abstract:RATIONALE AND OBJECTIVES:The influence of lipiodol injection on hepatic morphology and function was investigated in 119 rabbits with hepatic VX2 tumors. METHODS:The rabbits were divided into the following three groups, according to the materials injected via the proper hepatic artery: group 1 received doxorubicin (Adr...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199302000-00009

    authors: Akashi Y,Koreeda C,Mizuno T,Inoue K,Kawa SK,Tanaka Y

    更新日期:1993-02-01 00:00:00

  • Critical Questions Regarding Gadolinium Deposition in the Brain and Body After Injections of the Gadolinium-Based Contrast Agents, Safety, and Clinical Recommendations in Consideration of the EMA's Pharmacovigilance and Risk Assessment Committee Recommend

    abstract::For magnetic resonance, the established class of intravenous contrast media is the gadolinium-based contrast agents. In the 3 decades since initial approval, these have proven in general to be very safe for human administration. However, in 2006, a devastating late adverse reaction to administration of the less stable...

    journal_title:Investigative radiology

    pub_type: 杂志文章,评审

    doi:10.1097/RLI.0000000000000374

    authors: Runge VM

    更新日期:2017-06-01 00:00:00

  • Applications of voxel shifting in magnetic resonance imaging.

    abstract::Due to the nature of three-dimensional Fourier transform (3-DFT) data acquisition in magnetic resonance imaging (MRI), the spatial relation between a resolved volume element (a voxel) and the object can be manipulated easily. Those manipulations have practical consequences in terms of registering slice positions with ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199012000-00006

    authors: Kramer D,Li A,Simovsky I,Hawryszko C,Hale J,Kaufman L

    更新日期:1990-12-01 00:00:00

  • First-in-Human Ultrasound Molecular Imaging With a VEGFR2-Specific Ultrasound Molecular Contrast Agent (BR55) in Prostate Cancer: A Safety and Feasibility Pilot Study.

    abstract:OBJECTIVE:BR55, a vascular endothelial growth factor receptor 2 (VEGFR2)-specific ultrasound molecular contrast agent (MCA), has shown promising results in multiple preclinical models regarding cancer imaging. In this first-in-human, phase 0, exploratory study, we investigated the feasibility and safety of the MCA for ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000362

    authors: Smeenge M,Tranquart F,Mannaerts CK,de Reijke TM,van de Vijver MJ,Laguna MP,Pochon S,de la Rosette JJMCH,Wijkstra H

    更新日期:2017-07-01 00:00:00

  • Temperature-Sensitive Frozen-Tissue Imaging for Cryoablation Monitoring Using STIR-UTE MRI.

    abstract:PURPOSE:The aim of this study was to develop a method to delineate the lethally frozen-tissue region (temperature less than -40°C) arising from interventional cryoablation procedures using a short tau inversion-recovery ultrashort echo-time (STIR-UTE) magnetic resonance (MR) imaging sequence. This method could serve as...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000642

    authors: Tokuda J,Wang Q,Tuncali K,Seethamraju RT,Tempany CM,Schmidt EJ

    更新日期:2020-05-01 00:00:00

  • Measurement of distensibility of blood vessels using cineangiograms.

    abstract::We developed a new, cineangiographic method to accurately measure the dynamic changes in the internal diameter of human arteries in vivo. Cine films were digitized at a spatial resolution of 4 microns/pixel, using a line image sensor. The vessel edges, with a Gaussian fit to a unilateral profile curve of the vessel, w...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198909000-00005

    authors: Sugahara T,Yanagihara Y,Uyama C,Maeda H,Takafuchi M,Azumi T

    更新日期:1989-09-01 00:00:00

  • The uptake of manganese dipyridoxal-diphosphate by chemically induced hepatocellular carcinoma in rats. A correlation between contrast-media-enhanced magnetic resonance imaging, tumor differentiation, and vascularization.

    abstract:OBJECTIVES AND RATIONALE:Negative enhancement of implanted liver tumors has been achieved in preclinical studies on manganese dipyridoxal-diphosphate (Mn-DPDP), a new hepatobiliary specific contrast agent for magnetic resonance imaging (MRI). The authors investigated the effects of Mn-DPDP on primary liver cancer and i...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199306000-00011

    authors: Ni Y,Marchal G,Zhang X,Van Hecke P,Michiels J,Yu J,Rummeny E,Lodemann KP,Baert AL

    更新日期:1993-06-01 00:00:00

  • Auditory cortex activation in deaf subjects during cochlear electrical stimulation. Evaluation by functional magnetic resonance imaging.

    abstract:RATIONALE AND OBJECTIVES:The authors detect activation in the auditory cortex during cochlear electrical stimulation in deaf patients using functional magnetic resonance (MR) imaging. METHODS:Stimulating electrode was inserted gently under local anesthesia close to the round window membrane of the cochlea in seven coc...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199705000-00007

    authors: Berthezène Y,Truy E,Morgon A,Giard MH,Hermier M,Franconi JM,Froment JC

    更新日期:1997-05-01 00:00:00

  • Time continuous tracking and segmentation of cardiovascular magnetic resonance images using multidimensional dynamic programming.

    abstract::In this article, we propose a semiautomatic method for time-continuous contour detection in all phases of the cardiac cycle in magnetic resonance sequences. The method is based on multidimensional dynamic programming. After shape parameterization, cost hypercubes are filled with image-feature derived cost function val...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/01.rli.0000194070.88432.24

    authors: Uzümcü M,van der Geest RJ,Swingen C,Reiber JH,Lelieveldt BP

    更新日期:2006-01-01 00:00:00

  • Diminished cerebrospinal fluid beta-endorphin concentration in monkeys with arachnoiditis.

    abstract::Altered concentrations of brain beta endorphin and spinal cord encephalin have been reported in mice with iatrogenic arachnoiditis. We measured beta-endorphin concentration in cerebrospinal fluid (CSF) in normal monkeys and in monkeys with various degrees of arachnoiditis resulting from myelography and spinal surgery ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198803000-00006

    authors: Lipman BT,Haughton VM

    更新日期:1988-03-01 00:00:00

  • Lactate accumulation in ischemic- and anoxic-isolated rat hearts assessed by H-1 spectroscopy.

    abstract::Proton magnetic resonance (MR) spectroscopy with homonuclear editing was used to assess lactate accumulation in ischemic and anoxic hearts perfused according to the Langendorff method. An increase in the lactate signal was observed after 5 minutes of ischemia and after 10 to 20 minutes of anoxia. This study demonstrat...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198708000-00004

    authors: Richards TL,Terrier F,Sievers RE,Lipton MJ,Moseley ME,Higgins CB

    更新日期:1987-08-01 00:00:00

  • Control of experimental traumatic hepatic hemorrhage by transcatheter embolization.

    abstract::The feasibility of control of traumatic hepatic hemorrhage by angiographic transcatheter embolization was investigated. Bleeding sites were created in the livers of each of twelve dogs, and the hepatic artery was occluded with Gelfoam. Successful control of bleeding was demonstrated by postembolization angiography in ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-197801000-00014

    authors: Tyler T,Rosenbaum HD

    更新日期:1978-01-01 00:00:00

  • Assessment and monitoring tumor vascularity with contrast-enhanced ultrasound maximum intensity persistence imaging.

    abstract:OBJECTIVES:Contrast-enhanced ultrasound imaging is increasingly being used in the clinic for assessment of tissue vascularity. The purpose of our study was to evaluate the effect of different contrast administration parameters on the in vivo ultrasound imaging signal in tumor-bearing mice using a maximum intensity pers...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e3181f9202d

    authors: Pysz MA,Foygel K,Panje CM,Needles A,Tian L,Willmann JK

    更新日期:2011-03-01 00:00:00

  • Evaluation of CT time-density curves of lower-limb veins.

    abstract:UNLABELLED:Szapiro D, Ghaye B, Willems V, et al. Evaluation of CT time-density curves of lower-limb veins. Invest Radiol 2001;36:164-169. RATIONALE AND OBJECTIVES:To evaluate time-density curves of the lower-limb veins for optimization of CT venography. METHODS:Fifty patients referred for chest CT were randomized int...

    journal_title:Investigative radiology

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1097/00004424-200103000-00005

    authors: Szapiro D,Ghaye B,Willems V,Zhang L,Albert A,Dondelinger RF

    更新日期:2001-03-01 00:00:00

  • Magnetic resonance imaging of the cerebral aqueduct. Signal intensity time curves demonstrated by fast acquisition with multiple excitation (FAME).

    abstract::Using cardiac-gated fast acquisition with multiple excitation (FAME), time curves of the cerebral aqueduct signals were derived in 19 healthy volunteers and 14 patients. A mean curve of the normal subjects was determined during systole. A relatively stable point of time was found at 270 msec after the R-wave supposed ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198911000-00004

    authors: van den Hout JH,Bakker CJ,Mali WP,van Dijk P,Faber JA,Feldberg MA,Gooskens RH,Witkamp TD

    更新日期:1989-11-01 00:00:00

  • Advances in magnetic resonance (2006).

    abstract::Advances in the field of magnetic resonance (MR) as it pertains to clinical diagnostic radiology are examined in this review on the basis of publications in Investigative Radiology over the past 2 years (2005-2006). The articles published during that timeframe are discussed, organizationally wise, by anatomic region w...

    journal_title:Investigative radiology

    pub_type: 杂志文章,评审

    doi:10.1097/01.rli.0000250461.03245.5c

    authors: Runge VM

    更新日期:2006-12-01 00:00:00

  • A preliminary study of MRI quantification of simulated calcified pulmonary nodules.

    abstract::The potential of magnetic resonance imaging (MRI) quantification of calcium for the evaluation of pulmonary nodules was investigated in simulated nodules. Calcium salts do not contain mobile protons and thus have no signal on MR proton images. To determine whether the absence of signal from partially calcified nodules...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198711000-00001

    authors: Gamsu G,de Geer G,Cann C,Müller N,Brito A

    更新日期:1987-11-01 00:00:00

  • Effects of dilating the canine pulmonary annulus with two balloons. Doppler ultrasound and postmortem findings.

    abstract::Simultaneous inflation of two balloons may be necessary for balloon dilation valvuloplasty in patients with a large annulus. We examined the cardiovascular effects of dilating the pulmonary annulus with two balloons in 18 normal dogs using pulsed Doppler ultrasound and gross and microscopic examination. When the ratio...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198808000-00005

    authors: Butto F,Burke B,Berry JM,Amplatz K,Bass JL

    更新日期:1988-08-01 00:00:00

  • Computerized case-based instructional system for computed tomography and magnetic resonance imaging of brain tumors.

    abstract:RATIONALE AND OBJECTIVES:A computerized system that applies the case-based approach to training radiologists to diagnose brain tumors was designed. The authors attempted to provide residents a tool that supports their visual memory and inducts case-based reasoning. METHODS:A relational database with a digital image li...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199404000-00020

    authors: Macura RT,Macura KJ,Toro VE,Binet EF,Trueblood JH,Ji K

    更新日期:1994-04-01 00:00:00

  • An overview of neck node sonography.

    abstract:RATIONALE AND OBJECTIVES:Gray scale and power Doppler sonography are commonly used to evaluate cervical lymph nodes. This study was undertaken to identify which of the features used in ultrasound of cervical lymph nodes is readily applicable in routine clinical practice. METHODS:Two hundred and eight-six patients diag...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-200206000-00005

    authors: Ahuja A,Ying M

    更新日期:2002-06-01 00:00:00

  • Magnetic resonance angiography in infrapopliteal arterial disease: prospective comparison of 1.5 and 3 Tesla magnetic resonance imaging.

    abstract:PURPOSE:To prospectively determine the accuracy of 1.5 Tesla (T) and 3 T magnetic resonance angiography (MRA) versus digital subtraction angiography (DSA) in the depiction of infrageniculate arteries in patients with symptomatic peripheral arterial disease. PATIENTS AND METHODS:A prospective 1.5 T, 3 T MRA, and DSA co...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/01.rli.0000262581.52315.ef

    authors: Diehm N,Kickuth R,Baumgartner I,Srivastav SK,Gretener S,Husmann MJ,Jaccard Y,Do do D,Triller J,Bonel HM

    更新日期:2007-06-01 00:00:00

  • Accuracy of ultrasound in fetal femur length determination. Ultrasound phantom study.

    abstract::An ultrasound phantom was constructed simulating fetal femurs in amniotic fluid. Bones of 26, 36, 50, 58, and 70 mm, representative of gestational ages ranging from 17 to 36 weeks, were scanned with mechanical sector, phased sector, and linear array systems (ATL, Diasonics, Acuson, and GE). Measurements were made with...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198505000-00016

    authors: Gamba JL,Bowie JD,Dodson WC,Hedlund LW

    更新日期:1985-05-01 00:00:00

  • The blood-brain barrier: effects of nonionic contrast media with and without addition of Ca2+ and Mg2+.

    abstract::Trypan blue and 197HgCl2 were used as markers of the increased leakage through the blood-brain barrier which developed after selective injection of different contrast media formulations into the internal carotid arteries of rabbits. Interest was focused on a new, experimental, nonionic medium (C-29) and possible effec...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-197907000-00007

    authors: Golman K

    更新日期:1979-07-01 00:00:00

  • Longitudinal Computed Tomography Monitoring of Pelvic Bones in Patients With Breast Cancer Using Automated Bone Subtraction Software.

    abstract:OBJECTIVE:The aim of this study was to optimize computed tomography (CT) surveillance of skeletal metastases in patients with breast cancer through the use of osseous subtraction maps between baseline and follow-up examinations created by a novel software algorithm. The new postprocessing algorithm segments the origina...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000343

    authors: Horger M,Thaiss WM,Wiesinger B,Ditt H,Fritz J,Nikolaou K,Kloth C

    更新日期:2017-02-01 00:00:00

  • Fibroblast response to gadolinium: role for platelet-derived growth factor receptor.

    abstract:OBJECTIVE:The purpose of this study was to assess the effects of gadolinium (Gd3+), provided as gadolinium chloride, on fibroblast function. MATERIALS AND METHODS:Human dermal fibroblasts in monolayer culture and intact skin in organ culture were exposed to the lanthanide metal (1-20 μM). RESULTS:Increased proliferat...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e3181e943d2

    authors: Bhagavathula N,Dame MK,DaSilva M,Jenkins W,Aslam MN,Perone P,Varani J

    更新日期:2010-12-01 00:00:00

  • Delayed Gadolinium Leakage in Ocular Structures: A Potential Marker for Age- and Vascular Risk Factor-Related Small Vessel Disease?

    abstract:BACKGROUND:Gadolinium leakage in ocular structures (GLOS) was recently observed in fluid-attenuated inversion recovery (FLAIR) images obtained the day after an initial gadolinium injection in stroke patients. The specificity of GLOS to stroke and its mechanisms remain unclear. OBJECTIVE:We investigated the factors ass...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000757

    authors: Galmiche C,Moal B,Marnat G,Sagnier S,Schweitzer C,Dousset V,Sibon I,Tourdias T

    更新日期:2021-01-19 00:00:00

  • A computer program for the localization of small areas in roentgenological images.

    abstract::A method and associated algorithm are presented which allow a simple and accurate determination to be made of the location of small symmetric areas presented in roentgenological images. The method utilizes an operator to visually spot object positions but eliminates the need for critical positoning accuracy on the ope...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-197603000-00007

    authors: Keller RA,Baily NA