Temperature-Sensitive Frozen-Tissue Imaging for Cryoablation Monitoring Using STIR-UTE MRI.

Abstract:

PURPOSE:The aim of this study was to develop a method to delineate the lethally frozen-tissue region (temperature less than -40°C) arising from interventional cryoablation procedures using a short tau inversion-recovery ultrashort echo-time (STIR-UTE) magnetic resonance (MR) imaging sequence. This method could serve as an intraprocedural validation of the completion of tumor ablation, reducing the number of local recurrences after cryoablation procedures. MATERIALS AND METHODS:The method relies on the short T1 and T2* relaxation times of frozen soft tissue. Pointwise Encoding Time with Radial Acquisition, a 3-dimensional UTE sequence with TE = 70 microseconds, was optimized with STIR to null tissues with a T1 of approximately 271 milliseconds, the threshold T1. Because the T1 relaxation time of frozen tissue in the temperature range of -40°C < temperature < -8°C is shorter than the threshold T1 at the 3-tesla magnetic field, tissues in this range should appear hyperintense. The sequence was evaluated in ex vivo frozen tissue, where image intensity and actual tissue temperatures, measured by thermocouples, were correlated. Thereafter, the sequence was evaluated clinically in 12 MR-guided prostate cancer cryoablations, where MR-compatible cryoprobes were used to destroy cancerous tissue and preserve surrounding normal tissue. RESULTS:The ex vivo experiment using a bovine muscle demonstrated that STIR-UTE images showed regions approximately between -40°C and -8°C as hyperintense, with tissues at lower and higher temperatures appearing dark, making it possible to identify the region likely to be above the lethal temperature inside the frozen tissue. In the clinical cases, the STIR-UTE images showed a dark volume centered on the cryoprobe shaft, Vinner, where the temperature is likely below -40°C, surrounded by a doughnut-shaped hyperintense volume, where the temperature is likely between -40°C and -8°C. The hyperintense region was itself surrounded by a dark volume, where the temperature is likely above -8°C, permitting calculation of Vouter. The STIR-UTE frozen-tissue volumes, Vinner and Vouter, appeared significantly smaller than signal voids on turbo spin echo images (P < 1.0 × 10), which are currently used to quantify the frozen-tissue volume ("the iceball"). The ratios of the Vinner and Vouter volumes to the iceball were 0.92 ± 0.08 and 0.29 ± 0.07, respectively. In a single postablation follow-up case, a strong correlation was seen between Vinner and the necrotic volume. CONCLUSIONS:Short tau inversion-recovery ultrashort echo-time MR imaging successfully delineated the area approximately between -40°C and -8°C isotherms in the frozen tissue, demonstrating its potential to monitor the lethal ablation volume during MR-guided cryoablation.

journal_name

Invest Radiol

journal_title

Investigative radiology

authors

Tokuda J,Wang Q,Tuncali K,Seethamraju RT,Tempany CM,Schmidt EJ

doi

10.1097/RLI.0000000000000642

subject

Has Abstract

pub_date

2020-05-01 00:00:00

pages

310-317

issue

5

eissn

0020-9996

issn

1536-0210

journal_volume

55

pub_type

杂志文章
  • Ioversol clinical safety summary.

    abstract::The authors evaluated double-blind comparative and open-label clinical trials in 1,186 patients who received ioversol to evaluate the safety and efficacy of ioversol, a new nonionic low-osmolality contrast medium, at iodine concentrations of 32%, 24%, and 16%. The results indicate that ioversol was well tolerated in a...

    journal_title:Investigative radiology

    pub_type: 临床试验,杂志文章

    doi:10.1097/00004424-198906001-00020

    authors: Benamor M,Aten EM,McElvany KD,Lankin DG,James MA,Buy-Gandal T,Harashe LT,Weinandt WJ

    更新日期:1989-06-01 00:00:00

  • The pediatric tracheostomy: III). An appraisal of xerography.

    abstract::Comparatively new in the roentgen evaluation of infants and children, xerography would appear to be ideal for portraying the pediatric airway. Since the radiation dose of xerography is higher than conventional radiography, its image quality is the subject of careful scrutiny in a pediatric setting here described in 23...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-197807000-00002

    authors: Scott JR,Kramer SS,Griscom NT

    更新日期:1978-07-01 00:00:00

  • Low-osmolality contrast media-induced ventricular fibrillation.

    abstract::We evaluated the incidence of ventricular fibrillation with low-osmolality contrast media by right coronary arteriography in eleven adult mongrel dogs. Following insertion of the catheter into the right coronary artery, a test solution was infused for 25 seconds (total 11 mL) or until fibrillation occurred. The test s...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198904000-00008

    authors: Hayakawa K,Yamashita K

    更新日期:1989-04-01 00:00:00

  • The biliary and urinary excretion of sodium tyropanoate and sodium ipodate in dogs: pharmacokinetics, influence of bile salts and choleretic effects with comparison to iopanoic acid.

    abstract::The biliary and urinary excretion of sodium tyropanoate (Bilopaque) and sodium ipodate (Oragrafin) were studied in unanesthetized bile-fistula dogs using stepwise, increasing, intravenous infusions of the contrast materials. A constant intravenous infusion of sodium taurocholate was administered at the rate of either ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-197701000-00017

    authors: Berk RN,Loeb PM,Cobo-Frenkel A,Barnhart JL

    更新日期:1977-01-01 00:00:00

  • Impact of Impaired Renal Function on Gadolinium Retention After Administration of Gadolinium-Based Contrast Agents in a Mouse Model.

    abstract:OBJECTIVES:The aim of this study was to investigate the impact of impaired renal function on gadolinium (Gd) retention in various organs after Gd-based contrast agent injection. MATERIALS AND METHODS:After local animal care and review committee approval, 23 normal mice and 26 with renal failure were divided into 4 tre...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000295

    authors: Kartamihardja AA,Nakajima T,Kameo S,Koyama H,Tsushima Y

    更新日期:2016-10-01 00:00:00

  • Optimizing an ultrasound contrast agent's stability using in vitro attenuation measurements.

    abstract:RATIONALE AND OBJECTIVES:To evaluate the changes in the microbubble population of a currently available ultrasound contrast agent (USCA) through attenuation measurements to optimize its clinical use. MATERIALS AND METHODS:The microbubble population from a galactose-based USCA (Levovist, Schering AG, Germany) was chara...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-200212000-00006

    authors: Correas JM,Kurtisovski E,Bridal SL,Amararene A,Hélénon O,Berger G

    更新日期:2002-12-01 00:00:00

  • Microcomputer-based technique for 3-D reconstruction and volume measurement of computer tomographic images. Part 1: Phantom studies.

    abstract::This paper presents a microcomputer-based technique that accurately quantifies volumes from computed tomographic (CT) scans of irregularly shaped objects as well as displaying 3-D reconstructions. The method uses standard CT film, allowing analysis of previous or outside CT studies. The planimetry method showed less t...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198812000-00001

    authors: Albright RE Jr,Fram EK

    更新日期:1988-12-01 00:00:00

  • Elimination of gadolinium-ethoxybenzyl-DTPA in a rat model of severely impaired liver and kidney excretory function. An experimental study in rats.

    abstract:RATIONALE AND OBJECTIVES:The authors investigated whether gadolinium-ethoxybenzyl-DTPA (Gd-EOB-DTPA) can be eliminated in the absence of the two usual excretory pathways (urinary or biliary) and whether a remaining excretory pathway is able to compensate for impaired liver or kidney function. METHODS:The study was per...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199402000-00017

    authors: Mühler A,Heinzelmann I,Weinmann HJ

    更新日期:1994-02-01 00:00:00

  • Interference of gadolinium-containing contrast-enhancing agents with colorimetric calcium laboratory testing.

    abstract:OBJECTIVES:The purpose of this study was to evaluate the extent to which various commercially available gadolinium-containing contrast-enhancing (CE) agents can interfere with the measurement of calcium levels by currently used laboratory methods, suggesting (spurious) hypocalcemia or hypercalcemia with a potential ris...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/01.rli.0000170447.45577.5e

    authors: Löwe A,Balzer T,Hirt U

    更新日期:2005-08-01 00:00:00

  • Comparison of left ventricular ejection fraction and regional contractility fraction pre and post coronary angiography.

    abstract::Thirty patients [four normals, eight with mild and 18 with severe coronary artery disease (CAD)] were studied to evaluate left ventricular function type and post coronary angiography. The end diastolic volume (EDV), end systolic volume (ESV), ejection fraction (EF) and the regional contractility fractions (RCF) of eig...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-197603000-00009

    authors: Sos TA,Baltaxe HA

    更新日期:1976-03-01 00:00:00

  • Response of tumors to therapy studied by 31P magnetic resonance spectroscopy.

    abstract::Magnetic resonance (MR) methods have been used to study the metabolic and vascular response of model tumors to tumor necrosis factor (TNF). Magnetic resonance measurements demonstrated acute reductions in tumor blood flow, measured from tumor uptake of D2O, and in tumor adenosine triphosphate (ATP), measured by 31P ma...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198912000-00022

    authors: Karczmar GS,Meyerhoff DJ,Speder A,Valone F,Wilkinson M,Shine N,Boska MD,Weiner MW

    更新日期:1989-12-01 00:00:00

  • Diatrizoate contrast agents: 2-amino-5-acetamido-, and 3,5-diamino-2,4,6-triiodobenzoates.

    abstract::We have examined the metabolic behavior of several triiodobenzoic acid derivatives because of the observed mutagenicity and cytotoxicity of 3-amino-5-acetamido-2,4,6-triiodobenzoate (I) and 3,5-diamino-2,4,6-triiodobenzoate (II). Measurements were facilitated using iodine-131 (131I)-labeled compounds. Drug retention i...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:

    authors: Weiss R,Hsu B,Wheeler L,Norman A,Riley RF

    更新日期:1981-11-01 00:00:00

  • Hepatocellular carcinoma: correlation between vascular endothelial growth factor level and degree of enhancement by multiphase contrast-enhanced computed tomography.

    abstract:RATIONALE AND OBJECTIVES:To determine whether vascular endothelial growth factor (VEGF) is a histopathological factor influencing contrast enhancement of hepatocellular carcinoma (HCC) on computed tomography (CT). METHODS:Twenty-two nodular HCCs underwent multiphase helical CT and surgery. Tumor size, histological gra...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-200108000-00008

    authors: Kwak BK,Shim HJ,Park ES,Kim SA,Choi D,Lim HK,Park CK,Chung JW,Park JH

    更新日期:2001-08-01 00:00:00

  • Evolution of the ablation region after magnetic resonance-guided high-intensity focused ultrasound ablation in a Vx2 tumor model.

    abstract:OBJECTIVES:Volumetric magnetic resonance (MR)-guided high-intensity focused ultrasound (HIFU) is a completely noninvasive image-guided thermal ablation technique. Recently, there has been growing interest in the use of MR-HIFU for noninvasive ablation of malignant tumors. Of particular interest for noninvasive ablation...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e3182820257

    authors: Wijlemans JW,Deckers R,van den Bosch MA,Seinstra BA,van Stralen M,van Diest PJ,Moonen CT,Bartels LW

    更新日期:2013-06-01 00:00:00

  • Contrast and electrolyte dynamics of the intravenous pyelogram. II. Disparities in serum and urine concentrations of meglumine and anion.

    abstract::Intravenous or intra-aortic injections of meglumine iothalamate in dogs indicate a slightly different tissue distribution and excretory pattern of the meglumine cation and the iothalamate anion. Differences in serum and urinary concentrations of these ions suggest some cellular penetration of the meglumine anion. In a...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-197507000-00004

    authors: Lasser EC,Lang JH,Hamblin AE,Rosen L

    更新日期:1975-07-01 00:00:00

  • High-Signal Intensity in the Dentate Nucleus and Globus Pallidus on Unenhanced T1-Weighted Images: Evaluation of the Macrocyclic Gadolinium-Based Contrast Agent Gadobutrol.

    abstract:OBJECTIVE:The aim of this study was to compare changes in the signal intensity (SI) ratio of the dentate nucleus (DN) to the pons, DN to cerebrospinal fluid (CSF), and globus pallidus (GP) to thalamus on unenhanced T1-weighted magnetic resonance imaging (MRI) scans after serial injections of the macrocyclic gadolinium-...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000227

    authors: Radbruch A,Weberling LD,Kieslich PJ,Hepp J,Kickingereder P,Wick W,Schlemmer HP,Bendszus M

    更新日期:2015-12-01 00:00:00

  • Evaluation of gadolinium 2,5-BPA-DO3A, a new macrocyclic hepatobiliary chelate, in normal liver and metastatic disease on high field magnetic resonance imaging.

    abstract:RATIONALE AND OBJECTIVES:A new hepatobiliary gadolinium chelate, gadolinium (Gd) 2,5-BPA-DO3A, was compared in two animal species with Gd HP-DO3A (gadoteridol), a clinically approved extracellular contrast agent, and Gd Cy2-DOTA, a second hepatobiliary chelate in preclinical development. The ligand in Gd 2,5-BPA-DO3A i...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199601000-00003

    authors: Runge VM,Wells JW,Williams NM

    更新日期:1996-01-01 00:00:00

  • Some practical issues of experimental design and data analysis in radiological ROC studies.

    abstract::Receiver operating characteristic (ROC) analysis has been used in a broad variety of medical imaging studies during the past 15 years, and its advantages over more traditional measures of diagnostic performance are now clearly established. But despite the essential simplicity of the approach, workers in the field ofte...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198903000-00012

    authors: Metz CE

    更新日期:1989-03-01 00:00:00

  • Microangiographic anatomy of the cat's eye.

    abstract::The microangiographic anatomy of the cat's eye is presented. The characteristic vascular pattern of each of the three distinct circulations, retinal choroidal, and ciliary is described and illustrated. ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-197501000-00007

    authors: Rothman SL,Kier EL,Deuker DK

    更新日期:1975-01-01 00:00:00

  • Sonography of the kidneys in hemolytic uremic syndrome.

    abstract::The sonographic appearance of kidneys in patients presenting with acute renal failure due to hemolytic-uremic syndrome (HUS) was evaluated and compared with that in an age-matched control series. In nine patients with HUS, the renal cortex was typically hyperechogenic and the renal pyramids appeared sonolucent. The re...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198607000-00006

    authors: Kenney PJ,Brinsko RE,Patel DV,Spitzer RE,Farrar FM

    更新日期:1986-07-01 00:00:00

  • Cine phase-contrast magnetic resonance imaging for analysis of flow phenomena in experimental aortic dissection.

    abstract::Using a 1.5 T magnetic resonance imaging (MRI) system, cine phase-contrast and magnitude images were obtained in three phantoms that simulated different anatomic configurations of aortic dissection. The dissection phantoms were made of compliant materials, and pulsatile flow was used in all experiments. Phantoms diffe...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199112000-00007

    authors: Iwai F,Sostman HD,Evans AJ,Nadel SN,Hedlund LW,Beam CA,Charles HC,Spritzer CE

    更新日期:1991-12-01 00:00:00

  • Comparative evaluation of digital radiography versus conventional radiography of fractured skulls.

    abstract:OBJECTIVES:The authors assessed the relative efficacy of conventional and digital storage-phosphor radiographs for the detection of skull fractures. METHODS:Fifty conventional film-screen radiographs (FSR) and 50 digital storage-phosphor radiographs (DR) with 66 fractures were compared. Five radiologists evaluated ima...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199308000-00005

    authors: Langen HJ,Klein HM,Wein B,Stargardt A,Günther RW

    更新日期:1993-08-01 00:00:00

  • Applications of voxel shifting in magnetic resonance imaging.

    abstract::Due to the nature of three-dimensional Fourier transform (3-DFT) data acquisition in magnetic resonance imaging (MRI), the spatial relation between a resolved volume element (a voxel) and the object can be manipulated easily. Those manipulations have practical consequences in terms of registering slice positions with ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199012000-00006

    authors: Kramer D,Li A,Simovsky I,Hawryszko C,Hale J,Kaufman L

    更新日期:1990-12-01 00:00:00

  • Terbutaline in diagnosis of interstitial fallopian tube obstruction.

    abstract::Effectiveness of terbutaline, a potent uterine muscle relaxant, for differentiation of temporary and anatomic interstitial fallopian tube obstruction (IFTO) at hysterosalpingography (HSG) was explored. In 43 IFTO evaluated, HSG after terbutaline showed patency in only one of 16 tubes in which IFTO was caused by spasm ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198803000-00010

    authors: Thurmond AS,Novy M,Rösch J

    更新日期:1988-03-01 00:00:00

  • Cerebral embolization in rats induced by red blood cells treated with hypertonic X-ray contrast medium.

    abstract:RATIONALE AND OBJECTIVES:Hypertonic X-ray contrast media induce morphologic changes in red blood cells (RBCs) and reduce their deformability when measured in vitro. This study investigated whether RBCs treated with hypertonic contrast media could induce circulatory as well as metabolic disturbances in vivo. METHODS:Au...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:

    authors: Miyazawa T,Murayama C,Yamanaka T,Fritz-Zieroth B

    更新日期:1993-09-01 00:00:00

  • Comparison of Gd(DTPA-BMA) (Omniscan) versus Gd(HP-DO3A) (ProHance) relative to gadolinium retention in human bone tissue by inductively coupled plasma mass spectroscopy.

    abstract:OBJECTIVE:The objective of this study was to determine the gadolinium (Gd) concentration remaining in human bone tissue after administration of standard clinical doses of 2 Gd-based contrast agents: ProHance and Omniscan. MATERIALS AND METHODS:After administration of 0.1 mmol/kg of Gd chelate to patients undergoing hi...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/01.rli.0000186569.32408.95

    authors: White GW,Gibby WA,Tweedle MF

    更新日期:2006-03-01 00:00:00

  • Value of in vivo T2 measurement for myocardial fibrosis assessment in diabetic mice at 11.75 T.

    abstract:OBJECTIVE:The aim of the study was to assess the value of in vivo T2 measurements to noninvasively quantify myocardial fibrosis in diabetic mice at 11.75 T. Diabetic cardiomyopathy is characterized by extracellular matrix alteration and microcirculation impairment. These conditions might provide electrical heterogeneit...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e318243e062

    authors: Bun SS,Kober F,Jacquier A,Espinosa L,Kalifa J,Bonzi MF,Kopp F,Lalevee N,Zaffran S,Deharo JC,Cozzone PJ,Bernard M

    更新日期:2012-05-01 00:00:00

  • Preliminary evaluation of Hexabrix for temporomandibular joint arthrography.

    abstract::A double-blind randomized study of ten patients compared Hexabrix 32% to Renografin-60 in TMJ arthrography. Equivalent volumes of contrast material were injected under fluoroscopic observation, with film quality and patient subjective response graded independently by three radiologists. In immediate arthrogram quality...

    journal_title:Investigative radiology

    pub_type: 临床试验,杂志文章

    doi:10.1097/00004424-198411001-00032

    authors: Katzberg RW

    更新日期:1984-11-01 00:00:00

  • Comparison of vascular opacification after bolus injection of iodixanol-320 iohexol-350.

    abstract:RATIONALE AND OBJECTIVES:The vascular opacification characteristics of a new nonionic, dimeric contrast agent, iodixanol, have been compared with a nonionic, monomeric agent, iohexol, using ultrafast computed tomography (UFCT). METHODS:In 10 experiments with mongrel dogs, the contrast agents were alternately injected ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199212000-00011

    authors: Gould R,Brasch RC,Sievers R,Baxter A,Aicher K

    更新日期:1992-12-01 00:00:00

  • Biodistribution of radiolabeled, formulated gadopentetate, gadoteridol, gadoterate, and gadodiamide in mice and rats.

    abstract:RATIONALE AND OBJECTIVES:The authors studied the long-term distribution of gadolinium (Gd) in mice and rats after the administration of four commercially available magnetic resonance imaging contrast media. The goals were to determine any possible product dissociation in vivo and to evaluate the effects that product ex...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199506000-00008

    authors: Tweedle MF,Wedeking P,Kumar K

    更新日期:1995-06-01 00:00:00