Value of in vivo T2 measurement for myocardial fibrosis assessment in diabetic mice at 11.75 T.

Abstract:

OBJECTIVE:The aim of the study was to assess the value of in vivo T2 measurements to noninvasively quantify myocardial fibrosis in diabetic mice at 11.75 T. Diabetic cardiomyopathy is characterized by extracellular matrix alteration and microcirculation impairment. These conditions might provide electrical heterogeneity, which is a substrate for arrhythmogenesis. T1 mapping has been proposed to quantify diffuse myocardial fibrosis in cardiac diseases but has several limitations. T2 measurement may represent an alternative for fibrosis quantification at high magnetic field. MATERIALS AND METHODS:A magnetic resonance imaging protocol including in vivo T2 measurements at 11.75 T was performed in 9 male C57BL/6J mice after 8 weeks of streptozotocin-induced diabetes and in 9 control mice. Programmed ventricular stimulation was performed in both groups. T2 measurements were compared with histologic quantification of fibrosis using picrosirius red staining. RESULTS:Myocardial T2 was significantly lower in diabetic mice (13.8 ± 2.8 ms) than in controls (18.9 ± 2.3 ms, P < 0.001). There was a good correlation between T2 and fibrosis area obtained by histopathology (R = 0.947, P < 0.001). During programmed ventricular stimulation, 3 nonsustained ventricular tachycardias were induced in diabetic mice versus none in the control group. CONCLUSIONS:The in vivo T2 relaxation time strongly correlated with myocardial fibrosis area assessed with histologic staining in diabetic mice.

journal_name

Invest Radiol

journal_title

Investigative radiology

authors

Bun SS,Kober F,Jacquier A,Espinosa L,Kalifa J,Bonzi MF,Kopp F,Lalevee N,Zaffran S,Deharo JC,Cozzone PJ,Bernard M

doi

10.1097/RLI.0b013e318243e062

subject

Has Abstract

pub_date

2012-05-01 00:00:00

pages

319-23

issue

5

eissn

0020-9996

issn

1536-0210

journal_volume

47

pub_type

杂志文章
  • Characterization of ultrasmall magnetite [correction of paramagnetic magnetite] particles as superparamagnetic contrast agents in MRI.

    abstract:RATIONALE AND OBJECTIVES:Very small dextran-coated magnetite particles were developed. These particles can be used either as immunospecific contrast agents for MRI by coupling to antibodies or as an interstitial contrast agent. METHODS:The particles were synthesized from iron chloride/dextran solutions. Size was evalu...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-200009000-00006

    authors: Grimm J,Karger N,Lüsse S,Winoto-Morbach S,Krisch B,Müller-Hülsbeck S,Heller M

    更新日期:2000-09-01 00:00:00

  • Control of experimental traumatic hepatic hemorrhage by transcatheter embolization.

    abstract::The feasibility of control of traumatic hepatic hemorrhage by angiographic transcatheter embolization was investigated. Bleeding sites were created in the livers of each of twelve dogs, and the hepatic artery was occluded with Gelfoam. Successful control of bleeding was demonstrated by postembolization angiography in ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-197801000-00014

    authors: Tyler T,Rosenbaum HD

    更新日期:1978-01-01 00:00:00

  • Image fusion in dual energy computed tomography: effect on contrast enhancement, signal-to-noise ratio and image quality in computed tomography angiography.

    abstract:OBJECTIVE:The aim of this study was to evaluate the influence of different weighting factors on contrast enhancement, signal-to-noise ratio (SNR), and image quality in image fusion in dual energy computed tomography (DECT) angiography. MATERIAL AND METHODS:Fifteen patients underwent a CT angiography of the aorta with ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e31818c3d4b

    authors: Behrendt FF,Schmidt B,Plumhans C,Keil S,Woodruff SG,Ackermann D,Mühlenbruch G,Flohr T,Günther RW,Mahnken AH

    更新日期:2009-01-01 00:00:00

  • Hemodynamic effect of iodinated high-viscosity contrast medium in the rat kidney: a diffusion-weighted MRI feasibility study.

    abstract:RATIONALE AND OBJECTIVES:To assess the abilities of dynamic diffusion-weighted MRI to demonstrate the effects in vivo of a high-viscosity iodinated contrast agent on medullary and cortical blood flow in the rat kidney. METHODS:Dynamic diffusion-weighted, echoplanar MR images obtained from five b-value single-shot acqu...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-200011000-00001

    authors: Laissy JP,Menegazzo D,Dumont E,Piekarski JD,Karila-Cohen P,Chillon S,Schouman-Claeys E

    更新日期:2000-11-01 00:00:00

  • Intravoxel incoherent motion diffusion-weighted imaging of pancreatic neuroendocrine tumors: prediction of the histologic grade using pure diffusion coefficient and tumor size.

    abstract:PURPOSE:The purpose of this study was to assess the value of intravoxel incoherent motion and diffusion-weighted imaging for predicting the histologic grade of pancreatic neuroendocrine tumors (PNETs). MATERIALS AND METHODS:Forty patients with surgically diagnosed PNETs who underwent preoperative magnetic resonance im...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000028

    authors: Hwang EJ,Lee JM,Yoon JH,Kim JH,Han JK,Choi BI,Lee KB,Jang JY,Kim SW,Nickel MD,Kiefer B

    更新日期:2014-06-01 00:00:00

  • Pathophysiology of radiocontrast nephropathy: a role for medullary hypoxia.

    abstract::Recent experimental data underlies the role of hypoxic tubular injury in the pathophysiology of radiocontrast nephropathy. Although systemic transient hypoxemia, increased blood viscosity, and a leftward shift of the oxygen-hemoglobin dissociation curve may all contribute to intrarenal hypoxia, imbalance between oxyge...

    journal_title:Investigative radiology

    pub_type: 杂志文章,评审

    doi:10.1097/00004424-199911000-00004

    authors: Heyman SN,Reichman J,Brezis M

    更新日期:1999-11-01 00:00:00

  • Mechanism of hepatic parenchyma-specific contrast of microbubble-based contrast agent for ultrasonography: microscopic studies in rat liver.

    abstract:OBJECTIVE:The objective of this study was to elucidate the mechanism of hepatic parenchyma-specific contrast of Sonazoid (microbubble contrast agent) using microscopic techniques. MATERIALS AND METHODS:Sonazoid was intravenously injected into rats to investigate the microbubble dynamics and distribution within hepatic...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e31805f2682

    authors: Watanabe R,Matsumura M,Munemasa T,Fujimaki M,Suematsu M

    更新日期:2007-09-01 00:00:00

  • Feasibility of 3T dynamic contrast-enhanced magnetic resonance-guided biopsy in localizing local recurrence of prostate cancer after external beam radiation therapy.

    abstract:OBJECTIVES:The objective of this study was to assess the feasibility of the combination of magnetic resonance (MR)-guided biopsy (MRGB) and diagnostic 3T MR imaging in the localization of local recurrence of prostate cancer (PCa) after external beam radiation therapy (EBRT). MATERIALS AND METHODS:Twenty-four consecuti...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e3181c7bcda

    authors: Yakar D,Hambrock T,Huisman H,Hulsbergen-van de Kaa CA,van Lin E,Vergunst H,Hoeks CM,van Oort IM,Witjes JA,Barentsz JO,Fütterer JJ

    更新日期:2010-03-01 00:00:00

  • Pyrroxamide, a nonionic nitroxyl spin label contrast agent for magnetic resonance imaging. Mutagenesis and cell survival.

    abstract::Pyrroxamide [N-(1-hydroxymethyl-2,3-dihydroxypropyl)-2,2,5,5-tetramethyl pyrrolidine-1-oxyl-3-carboxyamide] is a newly tested nonionic monomeric nitroxyl compound with demonstrated effectiveness for MRI contrast enhancement at doses as low as 10(-3) M. Pyrroxamide and its hydroxylamine metabolic derivative were tested...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198808000-00013

    authors: Gordon DG,Brasch RC,Ogan MD,Deen D

    更新日期:1988-08-01 00:00:00

  • Evaluation of complex joint motion with computer-based analysis of fluoroscopic sequences.

    abstract:RATIONALE AND OBJECTIVES:To develop a computer-assisted analysis of complex joint motion based on standard fluoroscopic sequences. MATERIALS AND METHODS:Fluoroscopic sequences of 10 normal shoulders and 20 patients after total shoulder arthroplasty were recorded during abduction and adduction. The analysis of the shou...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-200202000-00004

    authors: Pfirrmann CW,Huser M,Székely G,Hodler J,Gerber C

    更新日期:2002-02-01 00:00:00

  • Elimination of gadolinium-ethoxybenzyl-DTPA in a rat model of severely impaired liver and kidney excretory function. An experimental study in rats.

    abstract:RATIONALE AND OBJECTIVES:The authors investigated whether gadolinium-ethoxybenzyl-DTPA (Gd-EOB-DTPA) can be eliminated in the absence of the two usual excretory pathways (urinary or biliary) and whether a remaining excretory pathway is able to compensate for impaired liver or kidney function. METHODS:The study was per...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199402000-00017

    authors: Mühler A,Heinzelmann I,Weinmann HJ

    更新日期:1994-02-01 00:00:00

  • Observer variation in abdominal CT.

    abstract::Observer performance in radiologic interpretation has traditionally been based upon Receiver Operating Characteristic (ROC) analysis. A statistical method that evaluates the reproducibility or consistency of radiologic interpretation is presented. Since this method is not based upon pathologic verification, it cannot ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198411000-00024

    authors: Herman S,DeBoer G,Rideout DF,Majesky IF

    更新日期:1984-11-01 00:00:00

  • Alteration of human tumor cell adhesion by high-strength static magnetic fields.

    abstract:RATIONALE AND OBJECTIVES:The authors investigated whether the ability of human malignant melanoma cells to increase in cell number or their ability to remain viable was compromised by high-field strength static magnetic fields. Normal human fibroblasts also were studied to determine if any magnetic field-related altera...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199210000-00014

    authors: Short WO,Goodwill L,Taylor CW,Job C,Arthur ME,Cress AE

    更新日期:1992-10-01 00:00:00

  • The etiology and implications of dense cavitary "photopenia" on myocardial perfusion scintigraphy.

    abstract::Dense cavitary "photopenia" was observed on 21 of 200 consecutive stress perfusion scintigrams. A prominent finding in many cases, it sometimes occupied only a portion of the region overlying the ventricular cavity, was often seen in some projections and not others, and was frequently adjacent to myocardial perfusion ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198507000-00009

    authors: Dae M,Canhasi B,Botvinick E,Olvera S,Schechtmann N,Engelstad B,Hattner R,Schiller N,O'Connell W,Faulkner D

    更新日期:1985-07-01 00:00:00

  • Evaluation of postprocessing dual-energy methods in quantitative computed tomography. Part 2. Practical aspects.

    abstract::Three facets of dual-energy quantitative computed tomography are studied: (1) the algorithm for postprocessing data (the methods of Cann, Laval-Jeantet et al, Goodsitt et al [two methods], and Nickoloff et al); (2) the influence of choice of tissue-equivalent materials for calibration; and (3) the difference between c...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199008000-00003

    authors: van Kuijk C,Grashuis JL,Steenbeek JC,Schütte HE,Trouerbach WT

    更新日期:1990-08-01 00:00:00

  • Evaluation and validation of ureteric jet index by glomerular filtration rate.

    abstract:RATIONALE AND OBJECTIVES:Ureteric jet index (UJI), a newly developed technique derived from color Doppler ultrasonography, may hold promise in evaluating renal function because of its ability to evaluate individual renal function and the use of nonionizing radiation. To assess the usefulness of UJI, the authors in this...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199908000-00001

    authors: Chiu NT,Wu CC,Yao WJ,Tu DG,Lee BF,Tong YC,Pan CC

    更新日期:1999-08-01 00:00:00

  • Digital mammography using iodine-based contrast media: initial clinical experience with dynamic contrast medium enhancement.

    abstract:PURPOSE:We sought to evaluate the potential of dynamic contrast enhancement after the intravenous administration of an iodine-based contrast medium in full-field digital mammography. MATERIAL AND METHODS:A protocol for image acquisition was established for contrast-enhanced mammography and the mammography unit (Senogr...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/01.rli.0000167421.83203.4e

    authors: Diekmann F,Diekmann S,Jeunehomme F,Muller S,Hamm B,Bick U

    更新日期:2005-07-01 00:00:00

  • Solid, part-solid, or non-solid?: classification of pulmonary nodules in low-dose chest computed tomography by a computer-aided diagnosis system.

    abstract:OBJECTIVES:The purpose of this study was to develop and validate a computer-aided diagnosis (CAD) tool for automatic classification of pulmonary nodules seen on low-dose computed tomography into solid, part-solid, and non-solid. MATERIALS AND METHODS:Study lesions were randomly selected from 2 sites participating in t...

    journal_title:Investigative radiology

    pub_type: 临床试验,杂志文章,多中心研究,随机对照试验

    doi:10.1097/RLI.0000000000000121

    authors: Jacobs C,van Rikxoort EM,Scholten ET,de Jong PA,Prokop M,Schaefer-Prokop C,van Ginneken B

    更新日期:2015-03-01 00:00:00

  • Mixing problems of low flow hepatic artery infusion. Improvement with small caliber double lumen balloon catheters.

    abstract::The problem of inhomogeneous mixing encountered during hepatic artery (HA) chemotherapy infusion was assessed and a practical solution examined. A glass model of the human HA distribution was used to determine mixing homogeneity of low flow (1.4 mL/minute) dye infusion into pulsatile flow (280-300 mL/minute) of a flui...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198807000-00007

    authors: Barth KH,Lutz RJ,Kremers PW,Miller DL

    更新日期:1988-07-01 00:00:00

  • Radiolabeled leukocytes and platelets.

    abstract::Radiolabeled blood cells are widely used for both clinical and research studies. In vitro and in vivo studies have shown the tagging process does not significantly affect function. The labeling techniques and clinical uses of labeled leukocytes and platelets are reviewed. ...

    journal_title:Investigative radiology

    pub_type: 杂志文章,评审

    doi:10.1097/00004424-198603000-00001

    authors: Datz FL

    更新日期:1986-03-01 00:00:00

  • Ultrahigh-field imaging of the biliary tract at 7 T: initial results of gadoxetic acid-enhanced magnetic resonance cholangiography.

    abstract:OBJECTIVES:The objectives of this study were to assess the feasibility of magnetic resonance cholangiography (MRC) using biliary-secreted gadoxetic acid at 7 T and to compare it with T2-weighted (w) MRC at 3 T. MATERIALS AND METHODS:Ten healthy volunteers were examined on a 7-T whole-body magnetic resonance system. T2...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000004

    authors: Fischer A,Kraff O,Orzada S,Nensa F,Schäfer LC,Ladd ME,Umutlu L,Lauenstein TC

    更新日期:2014-05-01 00:00:00

  • Intravascular ultrasound imaging of vascular responsiveness in isolated perfused canine arteries.

    abstract::We investigated the feasibility of using intravascular ultrasound imaging to analyze vascular physiology in various arterial beds. Canine superficial femoral, external iliac, and common carotid arteries were harvested and suspended and perfused in a bath of oxygenated, heated, physiologic salt solution. A 6-Fr, 20-MHz...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199103000-00010

    authors: Wilson MW,Webb RC,Marx MV,Meyer CR,Gallagher MA,Haarer SL,Buda AJ,Williams DM

    更新日期:1991-03-01 00:00:00

  • Screening mammography. A risk versus risk decision.

    abstract::The potential risk of a radiologic procedure often is compared with the potential benefit of the procedure. While risk vs. benefit analysis has been useful as a step toward increased communication and understanding among radiologists, referring physicians, and the general public, it has the disadvantage that risk and ...

    journal_title:Investigative radiology

    pub_type: 杂志文章,评审

    doi:10.1097/00004424-198901000-00005

    authors: Ritenour ER,Hendee WR

    更新日期:1989-01-01 00:00:00

  • Comparison of open- and closed-chest canine model for quantification of coronary stenosis severity by myocardial contrast echocardiography.

    abstract:RATIONALE AND OBJECTIVES:The objective of the present study was to compare the data regarding the ability of real-time myocardial contrast echocardiography (MCE) to assess altered myocardial blood flow produced by graded coronary stenoses between open- and closed-chest canine models. MATERIALS AND METHODS:Three grades...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-200301000-00006

    authors: Masugata H,Peters B,Lafitte S,Yao B,Strachan M,Ling Kwan O,Ohmori K,Mizushige K,Kohno M

    更新日期:2003-01-01 00:00:00

  • Evaluation of radiologist interpretive performance using blinded reads by multiple external readers.

    abstract:OBJECTIVE:To demonstrate a method of assessing radiologic diagnostic agreement utilizing multiple blinded external readers. METHODS:Six body CT studies interpreted by one reader (primary reader) at the host institution were compiled with patient identifiers removed. Brief clinical histories that were available to the ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e3181d2ee97

    authors: Ryan AF,Semelka RC,Molina PL,Yonkers S,Vaidean G

    更新日期:2010-04-01 00:00:00

  • Evaluation of the prostate imaging reporting and data system for the detection of prostate cancer by the results of targeted biopsy of the prostate.

    abstract:PURPOSE:The purpose of this study was to evaluate the magnetic resonance prostate imaging reporting and data system (PI-RADS) for the detection of prostate cancer by the results of magnetic resonance imaging (MRI)-guided biopsy of the prostate as a reference standard. PATIENTS AND METHODS:In 55 patients who had underg...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000030

    authors: Baur AD,Maxeiner A,Franiel T,Kilic E,Huppertz A,Schwenke C,Hamm B,Durmus T

    更新日期:2014-06-01 00:00:00

  • Design of an isolated pig heart preparation for positron emission tomography and magnetic resonance imaging.

    abstract:RATIONALE AND OBJECTIVES:Validation of new positron emission tomography (PET) tracers or magnetic (MR) imaging contrast agents is based on isolated rodent heart preparations. The use of larger animals could provide a more direct validation using the devices used for humans. METHODS:An isolated pig heart preparation ha...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199711000-00010

    authors: Casali C,Obadia JF,Canet E,Bendjelid K,André-Fouët X,Revel D,Janier MF

    更新日期:1997-11-01 00:00:00

  • Biodistribution of radiolabeled, formulated gadopentetate, gadoteridol, gadoterate, and gadodiamide in mice and rats.

    abstract:RATIONALE AND OBJECTIVES:The authors studied the long-term distribution of gadolinium (Gd) in mice and rats after the administration of four commercially available magnetic resonance imaging contrast media. The goals were to determine any possible product dissociation in vivo and to evaluate the effects that product ex...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199506000-00008

    authors: Tweedle MF,Wedeking P,Kumar K

    更新日期:1995-06-01 00:00:00

  • Microangiographic anatomy of the cat's eye.

    abstract::The microangiographic anatomy of the cat's eye is presented. The characteristic vascular pattern of each of the three distinct circulations, retinal choroidal, and ciliary is described and illustrated. ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-197501000-00007

    authors: Rothman SL,Kier EL,Deuker DK

    更新日期:1975-01-01 00:00:00

  • Renal effects of bicarbonate versus saline infusion for iso- and lowosmolar contrast media in rats.

    abstract:OBJECTIVE:Hydration is widely accepted as an effective measure to prevent contrast media (CM)-induced acute kidney injury (AKI). Whether bicarbonate (NaHCO₃) infusion has a greater effect than saline is disputed. Effective prevention of CM-induced AKI by NaHCO₃ has been found by several clinical trials. However, others...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e31822311a9

    authors: Ladwig M,Flemming B,Seeliger E,Sargsyan L,Persson PB

    更新日期:2011-11-01 00:00:00