Intravoxel incoherent motion diffusion-weighted imaging of pancreatic neuroendocrine tumors: prediction of the histologic grade using pure diffusion coefficient and tumor size.

Abstract:

PURPOSE:The purpose of this study was to assess the value of intravoxel incoherent motion and diffusion-weighted imaging for predicting the histologic grade of pancreatic neuroendocrine tumors (PNETs). MATERIALS AND METHODS:Forty patients with surgically diagnosed PNETs who underwent preoperative magnetic resonance imaging, including diffusion-weighted imaging with a series of 10 b values (0-1000 s/mm(2), were included in this institutional review board-approved retrospective study. The apparent diffusion coefficient (ADC(total)), the intravoxel incoherent motion parameters (pure diffusion coefficient [D], pseudodiffusion coefficient [D(*)], and perfusion fraction [f]) were measured on the tumors. Histologic grading was performed on the basis of the World Health Organization 2010 classification system. Logistic regression analysis and receiver operating curve analysis were performed to identify the significant factors predicting the histologic grades. RESULTS:Grades 2 and 3 tumors were significantly larger than grade 1 tumors (average 3.62 cm vs 2.17 cm in diameter; P=0.001). Grades 2 and 3 tumors showed significantly lower D values than did grade 1 tumors (0.95 vs 1.21×10(-3) mm(2)/s; P=0.009), although the ADC(total) showed no significant difference. When any of the following 2 criteria was used, (a) tumor size smaller than 2.0 cm in diameter and (b) D value greater than 1.2×10(-3) mm(2)/s, the sensitivity, specificity, and positive predictive value for diagnosing grade 1 PNETs were 76.92%, 100%, and 100%, respectively. CONCLUSIONS:Pure diffusion coefficient (D) is possibly a better marker than ADC(total) is for differentiating grade 1 from grade 2 or 3 PNET and, combined with tumor size, can predict grade 1 PNET with a high specificity.

journal_name

Invest Radiol

journal_title

Investigative radiology

authors

Hwang EJ,Lee JM,Yoon JH,Kim JH,Han JK,Choi BI,Lee KB,Jang JY,Kim SW,Nickel MD,Kiefer B

doi

10.1097/RLI.0000000000000028

subject

Has Abstract

pub_date

2014-06-01 00:00:00

pages

396-402

issue

6

eissn

0020-9996

issn

1536-0210

journal_volume

49

pub_type

杂志文章
  • Applications of voxel shifting in magnetic resonance imaging.

    abstract::Due to the nature of three-dimensional Fourier transform (3-DFT) data acquisition in magnetic resonance imaging (MRI), the spatial relation between a resolved volume element (a voxel) and the object can be manipulated easily. Those manipulations have practical consequences in terms of registering slice positions with ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199012000-00006

    authors: Kramer D,Li A,Simovsky I,Hawryszko C,Hale J,Kaufman L

    更新日期:1990-12-01 00:00:00

  • Comparison of Routine Brain Imaging at 3 T and 7 T.

    abstract:OBJECTIVE:The aim of this study was to compare quantitative and semiquantitative parameters (signal-to-noise ratio [SNR], contrast-to-noise ratio [CNR], image quality, diagnostic confidence) from a standard brain magnetic resonance imaging examination encompassing common neurological disorders such as demyelinating dis...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000256

    authors: Springer E,Dymerska B,Cardoso PL,Robinson SD,Weisstanner C,Wiest R,Schmitt B,Trattnig S

    更新日期:2016-08-01 00:00:00

  • Magnetic resonance imaging of pulmonary ventilation. Initial experiences with a gadolinium-DTPA-based aerosol.

    abstract:RATIONALE AND OBJECTIVES:The authors investigate whether a modified gadolinium (Gd)-DTPA formulation can be aerosolized and used as a contrast agent for magnetic resonance (MR) ventilation imaging of the lungs. METHODS:Gadolinium-DTPA (gadopentetate dimeglumine, Schering AG, Berlin, Germany, 100 mmol Gd/L) was modifie...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199712000-00010

    authors: Misselwitz B,Mühler A,Heinzelmann I,Böck JC,Weinmann HJ

    更新日期:1997-12-01 00:00:00

  • Clinical comparison between a currently available single-loop and an investigational dual-channel endorectal receive coil for prostate magnetic resonance imaging: a feasibility study at 1.5 and 3 T.

    abstract:OBJECTIVES:The objectives of this study were to test the feasibility of an investigational dual-channel next-generation endorectal coil (NG-ERC) in vivo, to quantitatively assess signal-to-noise ratio (SNR), and to get an impression of image quality compared with the current clinically available single-loop endorectal ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e3182a56678

    authors: Vos EK,Sambandamurthy S,Kamel M,McKenney R,van Uden MJ,Hoeks CM,Yakar D,Scheenen TW,Fütterer JJ

    更新日期:2014-01-01 00:00:00

  • Response of tumors to therapy studied by 31P magnetic resonance spectroscopy.

    abstract::Magnetic resonance (MR) methods have been used to study the metabolic and vascular response of model tumors to tumor necrosis factor (TNF). Magnetic resonance measurements demonstrated acute reductions in tumor blood flow, measured from tumor uptake of D2O, and in tumor adenosine triphosphate (ATP), measured by 31P ma...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198912000-00022

    authors: Karczmar GS,Meyerhoff DJ,Speder A,Valone F,Wilkinson M,Shine N,Boska MD,Weiner MW

    更新日期:1989-12-01 00:00:00

  • Changes in portal hemodynamics and acute rejection in the first 2 weeks after orthotopic liver transplantation. A prospective Doppler ultrasound study.

    abstract:RATIONALE AND OBJECTIVES:To analyze changes in Doppler ultrasound variables of the portal vein in relation to liver biopsy findings, the authors performed a prospective study of 316 Doppler ultrasound examinations in the first 2 weeks after orthotopic liver transplantation on 23 patients. METHODS:Recordings were obtai...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199612000-00007

    authors: Kok T,Slooff MJ,Peeters PM,Zwaveling JH,Bijleveld CM,Gi-van Loon CE,Klompmaker IJ,Haagsma EB

    更新日期:1996-12-01 00:00:00

  • Relative carotid blood flow measurements in dogs by high-speed CT. A preliminary study.

    abstract::A high-speed computed tomography (CT) scanner was used for measuring flow in a phantom and in the common carotid arteries of six dogs. The general ability of the scanner to assess flow using contrast media boluses was tested with the phantom. The validated simple concept was then used in the animals. The carotid blood...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198712000-00008

    authors: Ringertz HG,Jaschke W,Sievers R,Lipton MJ

    更新日期:1987-12-01 00:00:00

  • Comparison of the Relaxivities of Macrocyclic Gadolinium-Based Contrast Agents in Human Plasma at 1.5, 3, and 7 T, and Blood at 3 T.

    abstract:PURPOSE:The relaxivities of 3 macrocyclic gadolinium-based contrast agents (GBCAs) were determined in human plasma and blood under standardized and clinically relevant laboratory conditions. METHODS:The T1 relaxivity, r1, was determined in human plasma at 1.5, 3, and 7 T, and in human blood at 3 T at 37°C in phantoms ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000577

    authors: Szomolanyi P,Rohrer M,Frenzel T,Noebauer-Huhmann IM,Jost G,Endrikat J,Trattnig S,Pietsch H

    更新日期:2019-09-01 00:00:00

  • Some practical issues of experimental design and data analysis in radiological ROC studies.

    abstract::Receiver operating characteristic (ROC) analysis has been used in a broad variety of medical imaging studies during the past 15 years, and its advantages over more traditional measures of diagnostic performance are now clearly established. But despite the essential simplicity of the approach, workers in the field ofte...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198903000-00012

    authors: Metz CE

    更新日期:1989-03-01 00:00:00

  • Evaluation of Gd-EOB-DTPA uptake in a perfused and isolated mouse liver model: correlation between magnetic resonance imaging and monochromatic quantitative computed tomography.

    abstract:OBJECTIVES:The aim of this work was to quantitatively evaluate the pharmacokinetic pattern of Gd-EOB-DTPA in a model of isolated and perfused mouse liver by using magnetic resonance imaging (MRI) and monochromatic quantitative computed tomography (MQCT). MATERIALS AND METHODS:For MQCT, perfusions were realized with th...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/01.rli.0000174474.43772.58

    authors: Segers J,Le Duc G,Laumonier C,Troprès I,Elst LV,Muller RN

    更新日期:2005-09-01 00:00:00

  • Comparison of Fenestra VC Contrast-enhanced computed tomography imaging with gadopentetate dimeglumine and ferucarbotran magnetic resonance imaging for the in vivo evaluation of murine liver damage after ischemia and reperfusion.

    abstract:OBJECTIVES:Comparison of intravenous Fenestra VC-enhanced computed tomography (CT) with gadopentetate dimeglumine and Ferucarbotran contrast-enhanced magnetic resonance imaging (MRI) for the in vivo imaging of hepatic ischemia/reperfusion injury (IRI) in a murine model. MATERIAL AND METHODS:After induction of hepatic ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e318155aa2e

    authors: Choukèr A,Lizak M,Schimel D,Helmberger T,Ward JM,Despres D,Kaufmann I,Bruns C,Löhe F,Ohta A,Sitkovsky MV,Klaunberg B,Thiel M

    更新日期:2008-02-01 00:00:00

  • Magnetic resonance angiography. Application to the peripheral circulation.

    abstract::Magnetic resonance angiography (MRA) for application in the musculoskeletal system is progressing at a rapid pace. The clinical role of this new technique is still being developed, although a number of uses have already become well recognized, and MRA is diffusing into clinical practice. This article describes the bas...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199212002-00014

    authors: Harms SE,Flamig DP

    更新日期:1992-12-01 00:00:00

  • Effect of transcatheter hepatic arterial embolization on angiogenesis in an animal model.

    abstract:OBJECTIVES:Transcatheter arterial embolization (TAE) is used for the treatment of patients with malignant liver tumors. However, the proangiogenesis effect of TAE-associated hypoxia has not been adequately studied. The goal of this study was to determine angiogenic activity in tumors subjected to TAE by evaluating the ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/01.rli.0000209663.00629.8a

    authors: Gupta S,Kobayashi S,Phongkitkarun S,Broemeling LD,Kan Z

    更新日期:2006-06-01 00:00:00

  • Contrast gradient and the detection of lung nodules.

    abstract::The effects of edge gradient and blur on the detection pulmonary nodules were studied, using a test series of 175 artificial nodules on 30 chest films. The nodules were of homogeneous texture, about 1 cm in diameter and had a mean contrast of .12. Six observers viewed the film set, scoring both location and confidence...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-197901000-00004

    authors: Kundel HL,Revesz G,Toto L

    更新日期:1979-01-01 00:00:00

  • Imaging of complex NMR spectra.

    abstract::The Point Spread Function (PSF) in NMR imaging is the result of both the line broadening due to magnet field inhomogeneity and the intrinsic spectrum of the nucleus at resonance. In the case of proton imaging, the line broadening dominates the small chemical shifts and the spectral lines are not resolved. This is not ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198503000-00016

    authors: Harrison CG,Adams DF,Kramer PB

    更新日期:1985-03-01 00:00:00

  • Accuracy of ultrasound in fetal femur length determination. Ultrasound phantom study.

    abstract::An ultrasound phantom was constructed simulating fetal femurs in amniotic fluid. Bones of 26, 36, 50, 58, and 70 mm, representative of gestational ages ranging from 17 to 36 weeks, were scanned with mechanical sector, phased sector, and linear array systems (ATL, Diasonics, Acuson, and GE). Measurements were made with...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198505000-00016

    authors: Gamba JL,Bowie JD,Dodson WC,Hedlund LW

    更新日期:1985-05-01 00:00:00

  • Diffusion-Weighted Imaging of the Prostate: Image Quality and Geometric Distortion of Readout-Segmented Versus Selective-Excitation Accelerated Acquisitions.

    abstract:OBJECTIVE:To compare image quality and geometric distortion between readout-segmented diffusion-weighted imaging (rs-DWI) and selective-excitation accelerated reduced-field of view (FOV) DWI (sTX-DWI) of the prostate. MATERIALS AND METHODS:Sixty-five patients underwent 3-T MRI of the prostate including rs-DWI and sTX-...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000184

    authors: Barth BK,Cornelius A,Nanz D,Eberli D,Donati OF

    更新日期:2015-11-01 00:00:00

  • Estimation of chemical composition and density from computed tomography carried out at a number of energies.

    abstract::A method is presented by whichcomputed tomography scans carried out at a number of energies may be utilized to obtain cross-sectional images of density and atomic number in addition to the conventional array of linear attenuation coefficients. This type of analysis has been carried out for various substances of biolog...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-197703000-00016

    authors: McDavid WD,Waggener RG,Dennis MJ,Sank VJ,Payne WH

    更新日期:1977-03-01 00:00:00

  • Thirty-two-channel coil 3T magnetic resonance-guided biopsies of prostate tumor suspicious regions identified on multimodality 3T magnetic resonance imaging: technique and feasibility.

    abstract:OBJECTIVES:To test the technique and feasibility of translating tumor suspicious region maps in the prostate, obtained by multimodality, anatomic, and functional 3T magnetic resonance imaging (MRI) data to 32-channel coil, T2-weighted (T2-w), 3T MR images, for directing MR-guided biopsies. Furthermore, to evaluate the ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e31817d0506

    authors: Hambrock T,Fütterer JJ,Huisman HJ,Hulsbergen-vandeKaa C,van Basten JP,van Oort I,Witjes JA,Barentsz JO

    更新日期:2008-10-01 00:00:00

  • Evaluation of complex joint motion with computer-based analysis of fluoroscopic sequences.

    abstract:RATIONALE AND OBJECTIVES:To develop a computer-assisted analysis of complex joint motion based on standard fluoroscopic sequences. MATERIALS AND METHODS:Fluoroscopic sequences of 10 normal shoulders and 20 patients after total shoulder arthroplasty were recorded during abduction and adduction. The analysis of the shou...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-200202000-00004

    authors: Pfirrmann CW,Huser M,Székely G,Hodler J,Gerber C

    更新日期:2002-02-01 00:00:00

  • Diminished cerebrospinal fluid beta-endorphin concentration in monkeys with arachnoiditis.

    abstract::Altered concentrations of brain beta endorphin and spinal cord encephalin have been reported in mice with iatrogenic arachnoiditis. We measured beta-endorphin concentration in cerebrospinal fluid (CSF) in normal monkeys and in monkeys with various degrees of arachnoiditis resulting from myelography and spinal surgery ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198803000-00006

    authors: Lipman BT,Haughton VM

    更新日期:1988-03-01 00:00:00

  • Radiologic-pathologic-clinical correlation in mechanisms of disease course.

    abstract::The interdisciplinary approach to medical education has often been deficient in medical school curricula. Because of the nonintegrated approach to medical education, problem solving capabilities are not fostered. The clinical presentation of a patient, the imaging modalities used to investigate the patient, and the ul...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198604000-00015

    authors: Oldham SA,Jacobson F

    更新日期:1986-04-01 00:00:00

  • Semiautomatic lymph node segmentation in multislice computed tomography: impact of slice thickness on segmentation quality, measurement precision, and interobserver variability.

    abstract:OBJECTIVES:To determine the impact of slice thickness on semiautomatic lymph node analysis. MATERIALS AND METHODS:Thoracic multislice computed tomography (MSCT) of 46 patients with NSCLC were reconstructed at 1.0-, 3.0-, and 5.0-mm slice thickness. Two radiologists independently determined long and short axis diameter...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e3181c443e1

    authors: Buerke B,Puesken M,Beyer F,Gerss J,Weckesser M,Seifarth H,Heindel W,Wessling J

    更新日期:2010-02-01 00:00:00

  • Pulmonary density distribution in experimental noncardiac canine pulmonary edema evaluated by computed transmission tomography.

    abstract::We evaluated the density distribution (anterior-posterior) of the right lung in 19 acutely anesthetized supine dogs using computed transmission tomography (CTT). Eleven dogs served as controls, and eight received 0.12 cc/kg of intravenously administered oleic acid. The latter were sequentially imaged over 1 hour. Nine...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:

    authors: Slutsky RA,Long S,Peck WW,Higgins CB,Mattrey R

    更新日期:1984-05-01 00:00:00

  • Detection of breast abnormalities on teleradiology transmitted mammograms.

    abstract::The authors conducted an observer performance study to compare breast lesion detection of conventional mammography (CM) with teleradiology (TE) transmitted mammograms. One hundred four abnormal, single-projection mammographic images were transmitted by teleradiology. Abnormalities included 11 cases with skin thickenin...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199010000-00007

    authors: Fajardo LL,Yoshino MT,Seeley GW,Hunt R,Hunter TB,Friedman R,Cardenas D,Boyle R

    更新日期:1990-10-01 00:00:00

  • The potential of iosulamide meglumine as a contrast material for intravenous cholangiography: an experimental study in dogs.

    abstract::Because of relatively low acute toxicity, iosulamide meglumine has been recommended as an improved contrast material for intravenous cholangiography. It has been postulated that high doses of the compound could be given safely with the expectation of achieving greater biliary excretion and improved opacification of th...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198105000-00016

    authors: Berk RN,Barnhart JL,Nazareno G,Witt BL

    更新日期:1981-05-01 00:00:00

  • The biliary and urinary excretion of sodium tyropanoate and sodium ipodate in dogs: pharmacokinetics, influence of bile salts and choleretic effects with comparison to iopanoic acid.

    abstract::The biliary and urinary excretion of sodium tyropanoate (Bilopaque) and sodium ipodate (Oragrafin) were studied in unanesthetized bile-fistula dogs using stepwise, increasing, intravenous infusions of the contrast materials. A constant intravenous infusion of sodium taurocholate was administered at the rate of either ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-197701000-00017

    authors: Berk RN,Loeb PM,Cobo-Frenkel A,Barnhart JL

    更新日期:1977-01-01 00:00:00

  • Regional ejection fractions in patients with patent and thrombosed grafts after coronary artery vein bypass surgery.

    abstract::Twenty-six patients who had received 43 grafts were studied before and after coronary artery vein bypass surgery. Cine ventriculograms taken in the right anterior oblique projection were analyzed and regional ejection fractions calculated. Single and multiple grafts were considered separately as were thrombosed and pa...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-197705000-00001

    authors: Martin EC,Wixson D,Baltaxe HA

    更新日期:1977-05-01 00:00:00

  • Improved diagnosis of pulmonary emphysema using in vivo dark-field radiography.

    abstract:OBJECTIVES:The purpose of this study was to assess whether the recently developed method of grating-based x-ray dark-field radiography can improve the diagnosis of pulmonary emphysema in vivo. MATERIALS AND METHODS:Pulmonary emphysema was induced in female C57BL/6N mice using endotracheal instillation of porcine pancr...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000067

    authors: Meinel FG,Yaroshenko A,Hellbach K,Bech M,Müller M,Velroyen A,Bamberg F,Eickelberg O,Nikolaou K,Reiser MF,Pfeiffer F,Yildirim AÖ

    更新日期:2014-10-01 00:00:00

  • Comparing kidney perfusion using noncontrast arterial spin labeling MRI and microsphere methods in an interventional swine model.

    abstract:OBJECTIVE:The purpose of this study was to assess the ability of a flow-sensitive alternating inversion recovery-arterial spin labeling (FAIR-ASL) technique to track renal perfusion changes during pharmacologic and physiologic alterations in renal blood flow using microspheres as a gold standard. MATERIALS AND METHODS...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e3181f5e101

    authors: Artz NS,Wentland AL,Sadowski EA,Djamali A,Grist TM,Seo S,Fain SB

    更新日期:2011-02-01 00:00:00