Elimination of gadolinium-ethoxybenzyl-DTPA in a rat model of severely impaired liver and kidney excretory function. An experimental study in rats.

Abstract:

RATIONALE AND OBJECTIVES:The authors investigated whether gadolinium-ethoxybenzyl-DTPA (Gd-EOB-DTPA) can be eliminated in the absence of the two usual excretory pathways (urinary or biliary) and whether a remaining excretory pathway is able to compensate for impaired liver or kidney function. METHODS:The study was performed using two groups of animals: group A animals underwent ligation of the common bile duct, and group B animals underwent ligation of the renal blood vessels. A dose of 0.1 mmol/kg Gd-EOB-DTPA or Gd-DTPA (control) was injected via a tail vein. Bile or urine were collected in fractions of 0 to 1, 1 to 2, 2 to 4, and 4 to 8 hours after administration of either contrast agent. At the end of the experiments, detainment of the contrast agents was determined by measurement of Gd concentrations. RESULTS:Most of the Gd-EOB-DTPA was rapidly cleared from the body: 89.4% +/- 7.5% of the injected dose within 4 hours after bile duct ligation (group A) and 87.0% +/- 6.0% within 1 hour after ligation of renal vessels (group B). Eight hours after injection of Gd-EOB-DTPA, 3.0% +/- 2.4% of the administered dose of this contrast agent was found in the carcasses of group A animals, and 1.3% +/- 0.6% in carcasses of group B animals. By comparison, at 8 hours after injection, 1.9% +/- 3.2% of the injected Gd-DTPA was found in the carcasses of group A animals (no statistical significant difference as compared with Gd-EOB-DTPA), and 96.3% +/- 3.3% in carcasses of group B animals. CONCLUSIONS:In the rat model, the magnetic resonance imaging contrast agent Gd-EOB-DPTA is rapidly and effectively eliminated by virtue of its dual-elimination pathway. The dysfunction of liver or kidney may be fully compensated by the remaining elimination pathway.

journal_name

Invest Radiol

journal_title

Investigative radiology

authors

Mühler A,Heinzelmann I,Weinmann HJ

doi

10.1097/00004424-199402000-00017

subject

Has Abstract

pub_date

1994-02-01 00:00:00

pages

213-6

issue

2

eissn

0020-9996

issn

1536-0210

journal_volume

29

pub_type

杂志文章
  • Phlebography. Survey and present state.

    abstract::Milestones in the history of phlebography are shortly reviewed. The present state of phlebography with emphasis upon the role of new nonionic contrast media is presented. ...

    journal_title:Investigative radiology

    pub_type: 临床试验,杂志文章

    doi:

    authors: Enge I

    更新日期:1985-01-01 00:00:00

  • Sensitivity to detect small coronary artery calcium lesions with varying slice thickness using electron beam tomography.

    abstract:RATIONALE AND OBJECTIVE:To estimate the sensitivity to find small coronary artery calcium lesions with use of different slice widths with electron beam tomography. MATERIALS AND METHODS:Two studies were performed. Study 1 utilized double scanning of a stationary cork phantom with three different slice thickness (1.5, ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/01.RLI.0000055289.97726.B1

    authors: Mao S,Child J,Carson S,Liu SC,Oudiz RJ,Budoff MJ

    更新日期:2003-03-01 00:00:00

  • Vein graft-coated stents for endovascular occlusion of canine experimental arteriovenous fistulae.

    abstract:RATIONALE AND OBJECTIVES:To evaluate different vein graft-coated stent systems in the endovascular treatment of experimental arteriovenous fistulae (AVF) in a canine model. METHODS:Bilateral carotid-to-external jugular vein AVF were created. Two balloon-expandable tantalum stents (Strecker stent), two self-expanding n...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199901000-00004

    authors: Schellhammer F,Wahkloo AK,Nagursky H,Schumacher M

    更新日期:1999-01-01 00:00:00

  • Assessment of large bowel motility by cine magnetic resonance imaging using two different prokinetic agents: a feasibility study.

    abstract:OBJECTIVES:We sought to assess large bowel motility, induced by 2 prokinetic agents, senna tea and erythromycin, using functional cine magnetic resonance imaging (MRI). MATERIALS AND METHODS:Twelve volunteers underwent functional cine MRI before and after the administration of senna tea or erythromycin. The protocol c...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/01.rli.0000183054.43131.a8

    authors: Buhmann S,Kirchhoff C,Wielage C,Mussack T,Reiser MF,Lienemann A

    更新日期:2005-11-01 00:00:00

  • Granulocyte accumulation in the transplanted liver does not correlate with clinical and histologic evidence of dysfunction.

    abstract:RATIONALE AND OBJECTIVES:To evaluate the role of granulocytes in reperfusion injury after liver transplantation. The authors injected radiolabeled granulocytes to determine if human liver graft outcome could be correlated with granulocyte accumulation. MATERIALS AND METHODS:Pure granulocyte suspension was prepared fro...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199603000-00003

    authors: Ziser A,Forstrom LA,Plevak DJ,Sanchez-Urdazpal L,Gores GJ,Wiesner RH,Batts KP,Krom RA

    更新日期:1996-03-01 00:00:00

  • Magnetic resonance microscopy of the rat carotid artery at 300 megahertz.

    abstract:RATIONALE AND OBJECTIVES:Magnetic resonance microscopy (MRM) has evolved from a technical curiosity to a tool with which researchers can study important disease models. But MRM is not simply an extension of clinical magnetic resonance imaging. In this article, the unique adaptations of MRM required in the study of caro...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199409000-00004

    authors: Arnder L,Zhou X,Cofer GP,Hedlund LW,Johnson GA

    更新日期:1994-09-01 00:00:00

  • Systolic flow displacement correlates with future ascending aortic growth in patients with bicuspid aortic valves undergoing magnetic resonance surveillance.

    abstract:OBJECTIVES:Altered systolic blood flow in the ascending aorta has been correlated with increased aortic growth in patients with bicuspid aortic valves (BAVs). We used conventional, 2-dimensional (2D) phase contrast magnetic resonance imaging (PC-MRI) to assess the relationship between altered flow and future growth in ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000064

    authors: Burris NS,Sigovan M,Knauer HA,Tseng EE,Saloner D,Hope MD

    更新日期:2014-10-01 00:00:00

  • Noninvasive inductive stent heating: alternative approach to prevent instent restenosis?

    abstract:RATIONALE AND OBJECTIVES:To test noninvasive inductive heating of implanted vascular stents as an alternative approach for reduction or prevention of neointimal hyperplasia. METHODS:Calorimetric pretests were performed to get an orientation on the different parameters of influence for inductive heating of stents. The ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/01.rli.0000117881.42422.72

    authors: Floren MG,Günther RW,Schmitz-Rode T

    更新日期:2004-05-01 00:00:00

  • Vasopressin and hepatic artery. Effect of selective celiac infusion of vasopressin on the hepatic artery flow.

    abstract::Electromagnetic flow measurement study was performed in 20 anesthetized dogs to evaluate the effect of selective celiac infusion of vasopressin on the hepatic arterial vasculature. Teh hepatic arterial flow showed a biphasic response with an initial decrease followed by a substantial increase in spite of a continued ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:

    authors: Barr JW,Lakin RC,Rösch J

    更新日期:1975-05-01 00:00:00

  • Comparing kidney perfusion using noncontrast arterial spin labeling MRI and microsphere methods in an interventional swine model.

    abstract:OBJECTIVE:The purpose of this study was to assess the ability of a flow-sensitive alternating inversion recovery-arterial spin labeling (FAIR-ASL) technique to track renal perfusion changes during pharmacologic and physiologic alterations in renal blood flow using microspheres as a gold standard. MATERIALS AND METHODS...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e3181f5e101

    authors: Artz NS,Wentland AL,Sadowski EA,Djamali A,Grist TM,Seo S,Fain SB

    更新日期:2011-02-01 00:00:00

  • Influence of soft tissue (fat and fat-free mass) on ultrasound bone velocity: an in vivo study.

    abstract:RATIONALE AND OBJECTIVES:The authors determine the relative effect of soft-tissue compartments, body fat (percent [%Bfat] and weight [Bfat kg]) and fat-free mass (FFM kg), on measurements of ultrasound bone velocity (UBV m/second). METHODS:The authors measured UBV in proximal phalanxes and body fat and fat-free mass b...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199710000-00005

    authors: Gómez M,Aguado F,Manuel J,Menéndez JM,Revilla M,Villa LF,Cortés J,Rico H

    更新日期:1997-10-01 00:00:00

  • Diminished cerebrospinal fluid beta-endorphin concentration in monkeys with arachnoiditis.

    abstract::Altered concentrations of brain beta endorphin and spinal cord encephalin have been reported in mice with iatrogenic arachnoiditis. We measured beta-endorphin concentration in cerebrospinal fluid (CSF) in normal monkeys and in monkeys with various degrees of arachnoiditis resulting from myelography and spinal surgery ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198803000-00006

    authors: Lipman BT,Haughton VM

    更新日期:1988-03-01 00:00:00

  • Toward the Clinical Development and Validation of a Thy1-Targeted Ultrasound Contrast Agent for the Early Detection of Pancreatic Ductal Adenocarcinoma.

    abstract::Early detection of pancreatic ductal adenocarcinoma (PDAC) represents the most significant step toward the treatment of this aggressive lethal disease. Previously, we engineered a preclinical Thy1-targeted microbubble (MBThy1) contrast agent that specifically recognizes Thy1 antigen overexpressed in the vasculature of...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000697

    authors: Bam R,Daryaei I,Abou-Elkacem L,Vilches-Moure JG,Meuillet EJ,Lutz A,Marinelli ER,Unger EC,Gambhir SS,Paulmurugan R

    更新日期:2020-11-01 00:00:00

  • Digital mammography using iodine-based contrast media: initial clinical experience with dynamic contrast medium enhancement.

    abstract:PURPOSE:We sought to evaluate the potential of dynamic contrast enhancement after the intravenous administration of an iodine-based contrast medium in full-field digital mammography. MATERIAL AND METHODS:A protocol for image acquisition was established for contrast-enhanced mammography and the mammography unit (Senogr...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/01.rli.0000167421.83203.4e

    authors: Diekmann F,Diekmann S,Jeunehomme F,Muller S,Hamm B,Bick U

    更新日期:2005-07-01 00:00:00

  • Magnetic resonance imaging and histologic findings of experimental cerebral fat embolism.

    abstract:RATIONALE AND OBJECTIVES:The purpose of this study was to determine whether cerebral fat embolism demonstrated reversible or irreversible findings in magnetic resonance (MR) imaging over time and to compare the features in MR images with histologic findings in a cat model. MATERIALS AND METHODS:MR images were obtained...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/01.rli.0000077055.48406.e2

    authors: Kim HJ,Lee CH,Lee SH,Moon TY

    更新日期:2003-10-01 00:00:00

  • Towards computer analysis of pulmonary infiltration.

    abstract::A feasibility study is described to provide quantitative texture measures to distinguish between normal lung, alveolar infiltrates and interstitial infiltrates. Advanced computer imaging technology and decision making processes were applied to distinguish between these textural patterns. The results, based on computer...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-197807000-00005

    authors: Tully RJ,Conners RW,Harlow CA,Lodwick GS

    更新日期:1978-07-01 00:00:00

  • In-vitro assessment of the behavior of magnetic resonance angiography in the presence of constrictions.

    abstract:RATIONALE AND OBJECTIVES:Time-of-flight magnetic resonance angiography (TOF/MRA) is increasingly used to assess the nature and severity of stenotic blood vessels. Flow artifacts associated with high flows and/or narrow constrictions may confuse the interpretation of these studies. Accurate TOF/MRA evaluations demand an...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199307000-00011

    authors: Sebok NR,Sebok DA,Wilkerson D,Mezrich RS,Zatina M

    更新日期:1993-07-01 00:00:00

  • Assessment of myocardial viability using delayed enhancement magnetic resonance imaging at 3.0 Tesla.

    abstract:OBJECTIVE:Cardiac magnetic resonance imaging (MRI) at 3.0 T has recently become available and potentially provides a significant improvement of tissue contrast in T1-weighted imaging techniques relying on Gd-based contrast enhancement. Imaging at high-field strength may be especially advantageous for methods relying on...

    journal_title:Investigative radiology

    pub_type: 临床试验,杂志文章

    doi:10.1097/01.rli.0000233321.82194.09

    authors: Klumpp B,Fenchel M,Hoevelborn T,Helber U,Scheule A,Claussen C,Miller S

    更新日期:2006-09-01 00:00:00

  • Improving CT-Based PET Attenuation Correction in the Vicinity of Metal Implants by an Iterative Metal Artifact Reduction Algorithm of CT Data and Its Comparison to Dual-Energy-Based Strategies: A Phantom Study.

    abstract:OBJECTIVE:The aim of this study was to evaluate the potential of iterative metal artifact reduction (IMAR) for the improvement of computed tomography (CT)-based position emission tomography (PET) attenuation correction in the vicinity of metal implants and compare it with dual-energy-based metal artifact reduction stra...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000306

    authors: Schabel C,Gatidis S,Bongers M,Hüttig F,Bier G,Kupferschlaeger J,Bamberg F,la Fougère C,Nikolaou K,Pfannenberg C

    更新日期:2017-01-01 00:00:00

  • Image Quality and Geometric Distortion of Modern Diffusion-Weighted Imaging Sequences in Magnetic Resonance Imaging of the Prostate.

    abstract:PURPOSE:The aim of this study was to compare qualitative and quantitative image quality and geometric distortion of 4 magnetic resonance diffusion-weighted imaging (DWI) sequences of the prostate using comparable imaging parameters and similar acquisition times. METHODS AND MATERIALS:Axial T2-weighted turbo spin echo ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000429

    authors: Stocker D,Manoliu A,Becker AS,Barth BK,Nanz D,Klarhöfer M,Donati OF

    更新日期:2018-04-01 00:00:00

  • Comparison of open- and closed-chest canine model for quantification of coronary stenosis severity by myocardial contrast echocardiography.

    abstract:RATIONALE AND OBJECTIVES:The objective of the present study was to compare the data regarding the ability of real-time myocardial contrast echocardiography (MCE) to assess altered myocardial blood flow produced by graded coronary stenoses between open- and closed-chest canine models. MATERIALS AND METHODS:Three grades...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-200301000-00006

    authors: Masugata H,Peters B,Lafitte S,Yao B,Strachan M,Ling Kwan O,Ohmori K,Mizushige K,Kohno M

    更新日期:2003-01-01 00:00:00

  • Identifying tumor vascular permeability heterogeneity with magnetic resonance imaging contrast agents.

    abstract:RATIONALE AND OBJECTIVES:Dynamic contrast enhanced (DCE) MR mammography (MRM) uses tumor capillary density differences for prognosis. The heterogeneous response of permeability-surface area products (PS = Kp<-->t) was examined in mammary tumors, as a function of contrast agent size, to determine what effect ROI size mi...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-200204000-00003

    authors: Aref M,Brechbiel M,Wiener EC

    更新日期:2002-04-01 00:00:00

  • Time course of satisfaction of search.

    abstract::"Satisfaction of search" (SOS) refers to the effect in which a second lesion remains undetected after detection of another lesion on the same radiograph. The objective of this study was to clarify our understanding of SOS by relating it to total time of inspection and time intervals before, between, and after discover...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199107000-00003

    authors: Berbaum KS,Franken EA Jr,Dorfman DD,Rooholamini SA,Coffman CE,Cornell SH,Cragg AH,Galvin JR,Honda H,Kao SC

    更新日期:1991-07-01 00:00:00

  • Increased ablation zones using a cryo-based internally cooled bipolar RF applicator in ex vivo bovine liver.

    abstract:PURPOSE:To evaluate the feasibility of ex vivo ablation implementing a cryo-based internally cooled bipolar radiofrequency (RF) applicator and to determine the influence of power and gas pressure on the size and shape of the resulting ablation zones. MATERIALS AND METHODS:Two hundred twenty-five ablations were perform...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e3181b66d11

    authors: Rempp H,Voigtländer M,Clasen S,Kempf S,Neugebauer A,Schraml C,Schmidt D,Claussen CD,Enderle MD,Goldberg SN,Pereira PL

    更新日期:2009-12-01 00:00:00

  • Dynamic contrast-enhanced computed tomography as a potential biomarker in patients with metastatic renal cell carcinoma: preliminary results from the Danish Renal Cancer Group Study-1.

    abstract:OBJECTIVES:The aim of this study was to explore the impact of dynamic contrast-enhanced (DCE) computer tomography (CT) as a biomarker in metastatic renal cell carcinoma (mRCC). MATERIALS AND METHODS:Twelve patients with favorable or intermediate Memorial Sloan Kettering Cancer Center risk group and clear cell mRCC par...

    journal_title:Investigative radiology

    pub_type: 杂志文章,随机对照试验

    doi:10.1097/RLI.0000000000000058

    authors: Mains JR,Donskov F,Pedersen EM,Madsen HH,Rasmussen F

    更新日期:2014-09-01 00:00:00

  • The pediatric tracheostomy: III). An appraisal of xerography.

    abstract::Comparatively new in the roentgen evaluation of infants and children, xerography would appear to be ideal for portraying the pediatric airway. Since the radiation dose of xerography is higher than conventional radiography, its image quality is the subject of careful scrutiny in a pediatric setting here described in 23...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-197807000-00002

    authors: Scott JR,Kramer SS,Griscom NT

    更新日期:1978-07-01 00:00:00

  • Contrast gradient and the detection of lung nodules.

    abstract::The effects of edge gradient and blur on the detection pulmonary nodules were studied, using a test series of 175 artificial nodules on 30 chest films. The nodules were of homogeneous texture, about 1 cm in diameter and had a mean contrast of .12. Six observers viewed the film set, scoring both location and confidence...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-197901000-00004

    authors: Kundel HL,Revesz G,Toto L

    更新日期:1979-01-01 00:00:00

  • Renal blood oxygenation level-dependent imaging: contribution of R2 to R2* values.

    abstract:OBJECTIVES:The aim of this study was to assess the impact of oral water and intravenous furosemide challenges on blood oxygenation level-dependent magnetic resonance imaging measurements in the kidney and to examine the contribution of R2 (=1/T2) to changes in R2* (=1/T2*). MATERIALS AND METHODS:This Health Insurance ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e3182823591

    authors: Vivier PH,Storey P,Chandarana H,Yamamoto A,Tantillo K,Khan U,Zhang JL,Sigmund EE,Rusinek H,Babb JS,Bubenheim M,Lee VS

    更新日期:2013-07-01 00:00:00

  • Bone mineral analysis using single-energy computed tomography.

    abstract::We present a new method for evaluating in vivo changes in bone mineralization in the peripheral skeleton, using computed tomography (CT). A set of bone mineralization indices are generated from numerous CT images of the patient's distal radius. The cross-sectional anatomy displayed by the CT scan allows for separate e...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-197903000-00003

    authors: Orphanoudakis SC,Jensen PS,Rauschkolb EN,Lang R,Rasmussen H

    更新日期:1979-03-01 00:00:00

  • Characteristics of magnetic resonance sequences used for imaging silicone gel, saline, and gel-saline implants at low field strengths.

    abstract:RATIONALE AND OBJECTIVES:Low-field magnetic resonance imaging (MRI) evaluation of breast implants is described, with emphasis on the capabilities provided by different imaging sequences. METHODS:Open architecture MR images using a .064-T permanent magnet and three-dimensional Fourier transform and inversion recovery s...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199408000-00009

    authors: Frankel S,Occhipinti K,Kaufman L,Kramer D,Carlson J,Mineyev M,Friedenthal R

    更新日期:1994-08-01 00:00:00