Abstract:
RATIONALE AND OBJECTIVES:Time-of-flight magnetic resonance angiography (TOF/MRA) is increasingly used to assess the nature and severity of stenotic blood vessels. Flow artifacts associated with high flows and/or narrow constrictions may confuse the interpretation of these studies. Accurate TOF/MRA evaluations demand an understanding of the nature of these flow effects. METHODS:A two-dimensional TOF pulse sequence was used to acquire images of five smoothly constricted phantoms at various flows. Analysis included assessment of phantom appearance and quantification of apparent constriction diameter and signal variations. RESULTS:Most notable flow phenomena were a cone-shaped region of high signal, a region of signal void, and signal preservation along the wall. When visible, constriction diameter was accurately measured. CONCLUSIONS:The behavior observed in TOF/MRA images can be understood by considering the contributing mechanisms of phase dispersion, turbulence, poststenotic flow eddies, flow reversal, and flow separation.
journal_name
Invest Radioljournal_title
Investigative radiologyauthors
Sebok NR,Sebok DA,Wilkerson D,Mezrich RS,Zatina Mdoi
10.1097/00004424-199307000-00011subject
Has Abstractpub_date
1993-07-01 00:00:00pages
604-10issue
7eissn
0020-9996issn
1536-0210journal_volume
28pub_type
杂志文章abstract::Altered concentrations of brain beta endorphin and spinal cord encephalin have been reported in mice with iatrogenic arachnoiditis. We measured beta-endorphin concentration in cerebrospinal fluid (CSF) in normal monkeys and in monkeys with various degrees of arachnoiditis resulting from myelography and spinal surgery ...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198803000-00006
更新日期:1988-03-01 00:00:00
abstract::Screening chronic hemodialysis patients (CHD) for acquired cystic disease of the kidneys (ACDK) and its complications (hemorrhage and neoplasm) has become accepted management. We evaluated patients on CHD as well as patients on chronic peritoneal dialysis (CPD) for ACDK. The kidneys of 80 chronic dialysis patients wer...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:
更新日期:1987-09-01 00:00:00
abstract::The rate at which isotopes descend from the cisterna magna to the lumbar subarachnoid space is highly variable. In monkeys, with and without previous lumbar puncture, transit time was measured. In animals with a previous lumbar puncture, transit times were 10 to 120 minutes; in monkeys without a previous lumbar punctu...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198805000-00005
更新日期:1988-05-01 00:00:00
abstract:OBJECTIVES:The aims of this study were to implement and systematically evaluate the performance of a new parameter-free segmented algorithm for analysis of diffusion imaging data using a combined intravoxel incoherent motion and diffusion kurtosis imaging (IVIM-DKI) model of spin diffusion in comparison with the simple...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0000000000000223
更新日期:2016-03-01 00:00:00
abstract:OBJECTIVES:The aim of this study was to explore the impact of dynamic contrast-enhanced (DCE) computer tomography (CT) as a biomarker in metastatic renal cell carcinoma (mRCC). MATERIALS AND METHODS:Twelve patients with favorable or intermediate Memorial Sloan Kettering Cancer Center risk group and clear cell mRCC par...
journal_title:Investigative radiology
pub_type: 杂志文章,随机对照试验
doi:10.1097/RLI.0000000000000058
更新日期:2014-09-01 00:00:00
abstract::A method and associated algorithm are presented which allow a simple and accurate determination to be made of the location of small symmetric areas presented in roentgenological images. The method utilizes an operator to visually spot object positions but eliminates the need for critical positoning accuracy on the ope...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-197603000-00007
更新日期:1976-03-01 00:00:00
abstract::Recent experimental data underlies the role of hypoxic tubular injury in the pathophysiology of radiocontrast nephropathy. Although systemic transient hypoxemia, increased blood viscosity, and a leftward shift of the oxygen-hemoglobin dissociation curve may all contribute to intrarenal hypoxia, imbalance between oxyge...
journal_title:Investigative radiology
pub_type: 杂志文章,评审
doi:10.1097/00004424-199911000-00004
更新日期:1999-11-01 00:00:00
abstract::The extent to which various concentrations of the paramagnetic metal ions [gadolinium (III), manganese (II), chromium (III), iron (III), nickel (II), copper (II), and cobalt (II)] affect proton magnetic relaxation times of distilled water, 4% human serum albumin (HSA), and dog plasma was studied in vitro. The pH of wa...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198602000-00009
更新日期:1986-02-01 00:00:00
abstract::Skeletal abnormalities have been reported on numerous occasions in patients who have received high doses of vitamin A and its derivatives. Recently, a new derivative, isotretinoin (Accutane, Hoffman-LaRoche, Inc.), has become available for the treatment of cystic acne. Ninety-six patients treated for a minimum of four...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198601000-00007
更新日期:1986-01-01 00:00:00
abstract::Radiolabeled ioversol was injected intravenously into two male and two female beagle dogs (6.7 to 10.4 kg) at two dose levels each (0.2 and 1.0 g I/kg). Blood levels of radioactivity were monitored at 2, 5, 10, 20, 40, 60, 90, and 120 minutes and at one and two days. Urine and feces were collected in metabolism cages ...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198906001-00005
更新日期:1989-06-01 00:00:00
abstract::Perfluoroctylbromide (PFOB), a radiopaque reticuloendothelial system contrast media for computed tomography, has been shown to accumulate in macrophages. In the current study PFOB was tested in rabbits as an abscess imaging agent. Two abscesses were induced in each of 24 rabbits, one in the liver and the other in the ...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198409000-00017
更新日期:1984-09-01 00:00:00
abstract::Magnetic resonance angiography (MRA) for application in the musculoskeletal system is progressing at a rapid pace. The clinical role of this new technique is still being developed, although a number of uses have already become well recognized, and MRA is diffusing into clinical practice. This article describes the bas...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199212002-00014
更新日期:1992-12-01 00:00:00
abstract:RATIONAL AND OBJECTIVES:The feasibility of tubal occlusion by selective salpingography was tested in an animal model; three novel occluding materials also were tested for this application. METHODS:Unilateral selective salpingography was performed in three groups of six rabbits; fallopian tubes were embolized with etha...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199402000-00007
更新日期:1994-02-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:Target-specific magnetic resonance (MR) contrast agents are being developed to improve the accuracy of MR imaging. The purpose of this study was to determine the mechanism of cell uptake, and modes of intracellular trafficking of a prototypical iron oxide label (RMA) used in the synthesis of so...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199510000-00006
更新日期:1995-10-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:Ultrasound can cause destruction of microbubble contrast agents used to enhance medical ultrasound imaging. This study sought to characterize the dynamics of this interaction by direct visual observation of microbubbles during insonification in vitro by a medical ultrasound imaging system. MET...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199812000-00004
更新日期:1998-12-01 00:00:00
abstract:OBJECTIVE:There is little published information regarding the efficacy of paclitaxel-coated balloon catheters except for the iopromide-containing formulation, and less is known about the kind of toxicity at overdose. The aim of our study was to assess 2 different paclitaxel matrix formulations on angioplasty balloon ca...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0b013e31820577df
更新日期:2011-04-01 00:00:00
abstract:INTRODUCTION:Attenuation correction for magnetic resonance (MR) coils is a new challenge that came about with the development of combined MR and positron emission tomography (PET) imaging. This task is difficult because such coils are not directly visible on either PET or MR acquisitions with current combined scanners ...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0b013e3182a530f8
更新日期:2014-02-01 00:00:00
abstract:OBJECTIVES:The aim of this study was to investigate blood pressure dependency of ultrasound time-harmonic elastography (THE) for quantification of aortic stiffness. MATERIALS AND METHODS:Thoracoabdominal aortas were surgically removed from 9 healthy domestic pigs and prepared for elastographic experiments. All vessels...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0000000000000618
更新日期:2020-03-01 00:00:00
abstract::Thirty patients [four normals, eight with mild and 18 with severe coronary artery disease (CAD)] were studied to evaluate left ventricular function type and post coronary angiography. The end diastolic volume (EDV), end systolic volume (ESV), ejection fraction (EF) and the regional contractility fractions (RCF) of eig...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-197603000-00009
更新日期:1976-03-01 00:00:00
abstract::Previous investigations in this laboratory have confirmed the observation of facial muscle twitching during intracarotid injections of nonionic contrast media (CM) in rabbits. The reaction appears to be a locally mediated effect. To further investigate this reaction, cortical electroencephalogram (EEG) and facial elec...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199009000-00010
更新日期:1990-09-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:The authors studied premenopausal, perimenopausal, and postmenopausal women to determine if ultrasound bone velocity (UBV) on proximal phalanges of women reflect bone changes related to gonadal status and age. METHODS:A total of 166 healthy women-64 postmenopausal women (mean age 58.7 +/- 9.4 ...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199701000-00011
更新日期:1997-01-01 00:00:00
abstract:OBJECTIVES:Volumetric magnetic resonance (MR)-guided high-intensity focused ultrasound (HIFU) is a completely noninvasive image-guided thermal ablation technique. Recently, there has been growing interest in the use of MR-HIFU for noninvasive ablation of malignant tumors. Of particular interest for noninvasive ablation...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0b013e3182820257
更新日期:2013-06-01 00:00:00
abstract:PURPOSE:The purpose of this study was to evaluate the magnetic resonance prostate imaging reporting and data system (PI-RADS) for the detection of prostate cancer by the results of magnetic resonance imaging (MRI)-guided biopsy of the prostate as a reference standard. PATIENTS AND METHODS:In 55 patients who had underg...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0000000000000030
更新日期:2014-06-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:The purpose of this study evaluating a cesium iodide-amorphous silicon-based flat-panel detector was to optimize the x-ray spectrum for chest radiography combining excellent contrast-detail visibility with reduced patient exposure. MATERIALS AND METHODS:A Lucite plate with 36 drilled holes of ...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/01.rli.0000138091.96320.f8
更新日期:2004-10-01 00:00:00
abstract::We have examined the metabolic behavior of several triiodobenzoic acid derivatives because of the observed mutagenicity and cytotoxicity of 3-amino-5-acetamido-2,4,6-triiodobenzoate (I) and 3,5-diamino-2,4,6-triiodobenzoate (II). Measurements were facilitated using iodine-131 (131I)-labeled compounds. Drug retention i...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:
更新日期:1981-11-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:The effect of varying exposure parameters on the detectability of a fracture with digital and conventional radiography were examined. METHODS:A macerated fractured skull was imaged by film-screen radiography (FSR) and digital storage phosphor radiography (DR) with various exposure values. Five...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199303000-00010
更新日期:1993-03-01 00:00:00
abstract:OBJECTIVES:The aims of this study were to analyze the effect of dual-energy computed tomography (DECT) scanners and fluid characteristics on iodine quantification and to calculate the measurement variability range induced by those variables. METHODS:We performed an experimental phantom study with 4 mediastinal iodine ...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0000000000000446
更新日期:2018-06-01 00:00:00
abstract:PURPOSE:The aim of this study was to develop a method to delineate the lethally frozen-tissue region (temperature less than -40°C) arising from interventional cryoablation procedures using a short tau inversion-recovery ultrashort echo-time (STIR-UTE) magnetic resonance (MR) imaging sequence. This method could serve as...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0000000000000642
更新日期:2020-05-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:Paclitaxel added to angiographic contrast medium (CM) has been shown to inhibit restenosis in the porcine coronary overstretch model. This study determined early local tissue concentrations after the administration of different paclitaxel doses and preparations. MATERIALS AND METHODS:Fifteen p...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/01.rli.0000116125.96544.64
更新日期:2004-03-01 00:00:00
abstract::Radiolabeled blood cells are widely used for both clinical and research studies. In vitro and in vivo studies have shown the tagging process does not significantly affect function. The labeling techniques and clinical uses of labeled leukocytes and platelets are reviewed. ...
journal_title:Investigative radiology
pub_type: 杂志文章,评审
doi:10.1097/00004424-198603000-00001
更新日期:1986-03-01 00:00:00