Biodistribution and excretion of 125I ioversol in conscious dogs.

Abstract:

:Radiolabeled ioversol was injected intravenously into two male and two female beagle dogs (6.7 to 10.4 kg) at two dose levels each (0.2 and 1.0 g I/kg). Blood levels of radioactivity were monitored at 2, 5, 10, 20, 40, 60, 90, and 120 minutes and at one and two days. Urine and feces were collected in metabolism cages for two days, at the end of which the dogs were killed and organs or tissues (kidneys, liver, spleen, lungs, thyroid glands, heart, gonads, and muscle) were sampled. Radioactivity in tissues and excreta was assayed. Biexponential disappearance of radioactivity from blood was observed in three of four dogs at each dose level. Distribution half-lives averaged 2.5 to 3.5 minutes. Elimination half-lives averaged 51 to 54 minutes. Volumes of distribution averaged 25% to 27% of body weight. No organ retention was evident at 48 hours. Recovery of ioversol in urine and feces averaged 86% to 88% of the administered dose, of which all but a few percent was recovered in urine. On chromatographic assay, ioversol accounted for an average of 103% to 109% of radioiodine, suggesting, within the experimental limits of the assay, that ioversol is excreted unchanged. No dose-related differences were evident in any of these measures. The pharmacokinetics and biodistribution of ioversol are consistent with those of other extracellularly distributed iodinated contrast agents that are excreted by the kidney.

journal_name

Invest Radiol

journal_title

Investigative radiology

authors

Coveney JR,Robbins MS

doi

10.1097/00004424-198906001-00005

subject

Has Abstract

pub_date

1989-06-01 00:00:00

pages

S23-7

eissn

0020-9996

issn

1536-0210

journal_volume

24 Suppl 1

pub_type

杂志文章
  • Development of a macromolecular dual-modality MR-optical imaging for sentinel lymph node mapping.

    abstract:OBJECTIVE:To evaluate the effectiveness of a dual magnetic resonance-near infrared fluorescence optical imaging agent, poly(l-glutamic acid)-DTPA-Gd-NIR813, for both preoperative and intraoperative visualization and characterization of sentinel lymph nodes (SLN) in mice. MATERIALS AND METHODS:Poly(L-glutamic acid) was...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e31804f5a79

    authors: Melancon MP,Wang Y,Wen X,Bankson JA,Stephens LC,Jasser S,Gelovani JG,Myers JN,Li C

    更新日期:2007-08-01 00:00:00

  • Importance of parametric mapping and deconvolution in analyzing magnetic resonance myocardial perfusion images.

    abstract:AIM:: We sought to improve the clinical interpretation of first-pass myocardial magnetic resonance perfusion. Parametric analyses of the myocardial distribution of the contrast agent have been proposed. The objective of the present study was to compare the effectiveness of visual analysis and of a parametric approach i...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/01.rli.0000197980.89673.4b

    authors: Carme S,Maï W,Mazzadi A,Janier M,Revel D,Magnin I,Wiart M,Neyran B,Canet-Soulas E

    更新日期:2006-04-01 00:00:00

  • Clinical comparison between a currently available single-loop and an investigational dual-channel endorectal receive coil for prostate magnetic resonance imaging: a feasibility study at 1.5 and 3 T.

    abstract:OBJECTIVES:The objectives of this study were to test the feasibility of an investigational dual-channel next-generation endorectal coil (NG-ERC) in vivo, to quantitatively assess signal-to-noise ratio (SNR), and to get an impression of image quality compared with the current clinically available single-loop endorectal ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e3182a56678

    authors: Vos EK,Sambandamurthy S,Kamel M,McKenney R,van Uden MJ,Hoeks CM,Yakar D,Scheenen TW,Fütterer JJ

    更新日期:2014-01-01 00:00:00

  • The use of continuous and discrete confidence judgments in receiver operating characteristic studies of diagnostic imaging techniques.

    abstract::Virtually all receiver operating characteristic (ROC) studies of medical imaging methods have involved data collected on a discrete confidence-rating scale, though in principle ROC studies can be conducted with either discrete or continuous scales. Continuous scales provide potential advantages in medical applications...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199202000-00016

    authors: Rockette HE,Gur D,Metz CE

    更新日期:1992-02-01 00:00:00

  • Clinical safety and diagnostic value of the gadolinium chelate gadoterate meglumine (Gd-DOTA).

    abstract:OBJECTIVE:The purpose of this study was to assess the diagnostic value and safety of the contrast agent gadoterate meglumine (Gd-DOTA, DOTAREM, Guerbet, Roissy CdG Cedex, France) in the setting of a postmarketing surveillance study. MATERIALS AND METHODS:Between January 2004 and October 2005, radiologists in 61 radiol...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/01.rli.0000248893.01067.e5

    authors: Herborn CU,Honold E,Wolf M,Kemper J,Kinner S,Adam G,Barkhausen J

    更新日期:2007-01-01 00:00:00

  • A new animal model for testing renal tolerance of contrast agents.

    abstract:RATIONALE AND OBJECTIVES:To develop a new animal model for the evaluation of the renal tolerance of contrast agent and its application to diatrizoate and iotrolan injections in comparison to saline and mannitol solution. MATERIALS AND METHODS:The nephrotoxic potential of intravenously injected contrast agents in Beagl...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/01.rli.0000087096.61127.13

    authors: Krause W,Gilles T

    更新日期:2003-11-01 00:00:00

  • Evaluation of diffusion-weighted MR imaging at inclusion in an active surveillance protocol for low-risk prostate cancer.

    abstract:PURPOSE:We aimed to determine whether diffusion-weighted magnetic resonance imaging, by means of the apparent diffusion coefficient (ADC), is able to guide magnetic resonance-guided biopsy in patients fit for active surveillance (AS) and identify patients harboring high-grade Gleason components not suitable for AS. MA...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e31827b711e

    authors: Somford DM,Hoeks CM,Hulsbergen-van de Kaa CA,Hambrock T,Fütterer JJ,Witjes JA,Bangma CH,Vergunst H,Smits GA,Oddens JR,van Oort IM,Barentsz JO,MR-PRIAS Collaboration Group.

    更新日期:2013-03-01 00:00:00

  • Hepatic parenchymal changes after the intraarterial injection of lipiodol in tumor-bearing rabbits.

    abstract:RATIONALE AND OBJECTIVES:The influence of lipiodol injection on hepatic morphology and function was investigated in 119 rabbits with hepatic VX2 tumors. METHODS:The rabbits were divided into the following three groups, according to the materials injected via the proper hepatic artery: group 1 received doxorubicin (Adr...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199302000-00009

    authors: Akashi Y,Koreeda C,Mizuno T,Inoue K,Kawa SK,Tanaka Y

    更新日期:1993-02-01 00:00:00

  • Validation of ultrafast computed tomographic left ventricular volume measurement.

    abstract::Left ventricular volume has been measured with ultrafast computed tomography. However, the accuracy with which this can be done is unknown. We therefore imaged with ultrafast computed tomography 11 rectangular phantoms, 20 to 225 ml, and 17 left ventricular casts, 15 to 112 ml. Two observers planimetered serial tomogr...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199101000-00006

    authors: Pietras RJ,Wolfkiel CJ,Veselik K,Roig E,Chomka EV,Brundage BH

    更新日期:1991-01-01 00:00:00

  • Increased ablation zones using a cryo-based internally cooled bipolar RF applicator in ex vivo bovine liver.

    abstract:PURPOSE:To evaluate the feasibility of ex vivo ablation implementing a cryo-based internally cooled bipolar radiofrequency (RF) applicator and to determine the influence of power and gas pressure on the size and shape of the resulting ablation zones. MATERIALS AND METHODS:Two hundred twenty-five ablations were perform...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e3181b66d11

    authors: Rempp H,Voigtländer M,Clasen S,Kempf S,Neugebauer A,Schraml C,Schmidt D,Claussen CD,Enderle MD,Goldberg SN,Pereira PL

    更新日期:2009-12-01 00:00:00

  • Hepatic kinetics and magnetic resonance imaging of gadolinium-EOB-DTPA in dogs.

    abstract:RATIONALE AND OBJECTIVES:To measure the hepatic uptake and biliary elimination kinetics of gadolinium (Gd)-EOB-DTPA in dogs. METHOD:Two groups of four beagles each were anesthetized and given an intravenous bolus of 25 mumol/kg or 250 mumol/kg of Gd-EOB-DTPA. Blood, hepatic bile, and urine were collected over 140 minu...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199604000-00005

    authors: Benness G,Khangure M,Morris I,Warwick A,Burrows P,Vogler H,Weinmann HJ

    更新日期:1996-04-01 00:00:00

  • Analysis of edge-tracking errors inherent in fluoroscopic images of the beating heart.

    abstract:RATIONALE AND OBJECTIVES:Because of the complex relationships between the dynamic three-dimensional cardiac surface shape and its projected image, errors arise with the use of two-dimensional silhouettes to measure displacements of the heart. The character and frequency of such errors are examined. METHODS:A high-prec...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199403000-00004

    authors: McInerney JJ,Weldner PW,Herr MD,Copenhaver GL

    更新日期:1994-03-01 00:00:00

  • A double-blind comparative study of Hexabrix and Renografin-76 in aortography and visceral arteriography.

    abstract::A diatrizoate compound (Renografin-76) and low osmolality Hexabrix were compared in a double-blind study of 50 adults undergoing arteriographic examination. Subjective and objective assessment of pain reaction for each contrast injection rated lower overall for Hexabrix. Discomfort associated with Renografin was great...

    journal_title:Investigative radiology

    pub_type: 临床试验,杂志文章

    doi:10.1097/00004424-198411001-00012

    authors: Barth KH,Mertens MA

    更新日期:1984-11-01 00:00:00

  • Evaluation of Gd-EOB-DTPA uptake in a perfused and isolated mouse liver model: correlation between magnetic resonance imaging and monochromatic quantitative computed tomography.

    abstract:OBJECTIVES:The aim of this work was to quantitatively evaluate the pharmacokinetic pattern of Gd-EOB-DTPA in a model of isolated and perfused mouse liver by using magnetic resonance imaging (MRI) and monochromatic quantitative computed tomography (MQCT). MATERIALS AND METHODS:For MQCT, perfusions were realized with th...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/01.rli.0000174474.43772.58

    authors: Segers J,Le Duc G,Laumonier C,Troprès I,Elst LV,Muller RN

    更新日期:2005-09-01 00:00:00

  • Effects of iodinated x-ray contrast media on renal epithelial cells in culture.

    abstract:RATIONALE AND OBJECTIVES:To study cellular mechanisms that cause contrast media nephropathy, an in vitro system for proximal and distal tubular cells has been established to evaluate the influence of x-ray contrast media on tubular function. METHODS:Confluent cell cultures of the two renal cell lines, proximal tubule ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199411000-00002

    authors: Andersen KJ,Christensen EI,Vik H

    更新日期:1994-11-01 00:00:00

  • Binary nature and radiographic identifiability of craniosynostosis.

    abstract:RATIONALE AND OBJECTIVES:Two independent gold standards and diagnoses from three-dimensional computed tomography (CT) images were used to examine the possibility that craniosynostosis is a binary abnormality that potentially may be diagnosed without error. METHODS:Surgical reports, histology of excised sutures, and th...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199410000-00005

    authors: Pilgram TK,Vannier MW,Marsh JL,Kraemer BB,Rayne SC,Gado MH,Moran CJ,McAlister WH,Shackelford GD,Hardesty RA

    更新日期:1994-10-01 00:00:00

  • Critical Questions Regarding Gadolinium Deposition in the Brain and Body After Injections of the Gadolinium-Based Contrast Agents, Safety, and Clinical Recommendations in Consideration of the EMA's Pharmacovigilance and Risk Assessment Committee Recommend

    abstract::For magnetic resonance, the established class of intravenous contrast media is the gadolinium-based contrast agents. In the 3 decades since initial approval, these have proven in general to be very safe for human administration. However, in 2006, a devastating late adverse reaction to administration of the less stable...

    journal_title:Investigative radiology

    pub_type: 杂志文章,评审

    doi:10.1097/RLI.0000000000000374

    authors: Runge VM

    更新日期:2017-06-01 00:00:00

  • Visualization of breast lymphatic pathways with an indirect computed tomography lymphography using a nonionic monometric contrast medium iopamidol: preliminary results.

    abstract:RATIONALE AND OBJECTIVES:The capability of an indirect computed tomographic lymphography (CT-LG) using a nonionic monometric contrast medium iopamidol for visualizing breast lymphatic pathways was preliminarily tested. MATERIALS AND METHODS:In 10 female dogs, a total of 0.5 and 1 mL of undiluted iopamidol was injected...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-200302000-00002

    authors: Suga K,Ogasawara N,Yuan Y,Okada M,Matsunaga N,Tangoku A

    更新日期:2003-02-01 00:00:00

  • Reduction of Metal Artifacts and Improvement in Dose Efficiency Using Photon-Counting Detector Computed Tomography and Tin Filtration.

    abstract:OBJECTIVES:The aim of this study was to investigate the impact on metal artifacts and dose efficiency of using a tin filter in combination with high-energy threshold (TH) images of a photon-counting detector (PCD) computed tomography (CT) system. MATERIALS AND METHODS:A 3D-printed spine with pedicle screws was scanned...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000535

    authors: Zhou W,Bartlett DJ,Diehn FE,Glazebrook KN,Kotsenas AL,Carter RE,Fletcher JG,McCollough CH,Leng S

    更新日期:2019-04-01 00:00:00

  • Accuracy of ultrasound in fetal femur length determination. Ultrasound phantom study.

    abstract::An ultrasound phantom was constructed simulating fetal femurs in amniotic fluid. Bones of 26, 36, 50, 58, and 70 mm, representative of gestational ages ranging from 17 to 36 weeks, were scanned with mechanical sector, phased sector, and linear array systems (ATL, Diasonics, Acuson, and GE). Measurements were made with...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198505000-00016

    authors: Gamba JL,Bowie JD,Dodson WC,Hedlund LW

    更新日期:1985-05-01 00:00:00

  • Sonography of the kidneys in hemolytic uremic syndrome.

    abstract::The sonographic appearance of kidneys in patients presenting with acute renal failure due to hemolytic-uremic syndrome (HUS) was evaluated and compared with that in an age-matched control series. In nine patients with HUS, the renal cortex was typically hyperechogenic and the renal pyramids appeared sonolucent. The re...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198607000-00006

    authors: Kenney PJ,Brinsko RE,Patel DV,Spitzer RE,Farrar FM

    更新日期:1986-07-01 00:00:00

  • Application of direct cannulation and injection lymphangiography to the study of the canine cardiac and pulmonary efferent mediastinal lymphatics.

    abstract::Lymphangiograms of canine cardiac and pulmonary efferent mediastinal lymphatics were made by cannulation and injection of Ethiodol. Injections were made singly and serially. The mediastinal lymphatics and lymph nodes, which constitute the pathways of drainage of the heart and lungs, were delineated from the point of c...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-197901000-00012

    authors: Leeds SE,Uhley HN,Meister RB

    更新日期:1979-01-01 00:00:00

  • Magnetic resonance pulmonary angiography and direct imaging of embolus for the detection of pulmonary emboli.

    abstract:RATIONALE AND OBJECTIVES:The authors developed a two-dimensional breathhold magnetic resonance (MR) technique for the direct imaging of pulmonary emboli. METHODS:In vitro MR imaging was performed to demonstrate the potential generation of clot-blood contrast by in vivo pulmonary embolism (PE). A two-dimensional magnet...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199708000-00001

    authors: Moody AR,Liddicoat A,Krarup K

    更新日期:1997-08-01 00:00:00

  • Magnetic resonance imaging contrast enhancement of brain tumors at 3 tesla versus 1.5 tesla.

    abstract:RATIONALE AND OBJECTIVES:To compare the diagnostic efficacy of a standard dose of MRI contrast agent in the evaluation of primary brain tumors and metastases using a high-field 3 tesla MR unit versus a 1.5 tesla MR unit. METHODS:Sixteen patients with brain tumors were examined at both field strengths using identical a...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-200203000-00003

    authors: Nöbauer-Huhmann IM,Ba-Ssalamah A,Mlynarik V,Barth M,Schöggl A,Heimberger K,Matula C,Fog A,Kaider A,Trattnig S

    更新日期:2002-03-01 00:00:00

  • A revised estimate of the risk of carcinogenesis from x-rays to scoliosis patients.

    abstract::A considerable amount of concern has been felt recently for the risk of carcinogenesis from x-rays to scoliosis patients. This paper re-evaluates risk in quantitative terms by using some data measured by us and other data recently published in the literature. The risks are considerably smaller than had been estimated ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198401000-00014

    authors: Rao PS,Gregg EC

    更新日期:1984-01-01 00:00:00

  • Low tube voltage improves computed tomography imaging of delayed myocardial contrast enhancement in an experimental acute myocardial infarction model.

    abstract:OBJECTIVE:We sought to evaluate the influence of tube voltage on the visualization of acute myocardial infarction (MI) in cardiac multislice spiral computed tomography (MSCT). MATERIALS AND METHODS:Acute MI was induced in 12 domestic pigs by a 45-minute balloon occlusion of the left anterior descending artery. Delayed...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/01.rli.0000251577.68223.84

    authors: Mahnken AH,Bruners P,Mühlenbruch G,Emmerich M,Hohl C,Günther RW,Wildberger JE

    更新日期:2007-02-01 00:00:00

  • High-Signal Intensity in the Dentate Nucleus and Globus Pallidus on Unenhanced T1-Weighted Images: Evaluation of the Macrocyclic Gadolinium-Based Contrast Agent Gadobutrol.

    abstract:OBJECTIVE:The aim of this study was to compare changes in the signal intensity (SI) ratio of the dentate nucleus (DN) to the pons, DN to cerebrospinal fluid (CSF), and globus pallidus (GP) to thalamus on unenhanced T1-weighted magnetic resonance imaging (MRI) scans after serial injections of the macrocyclic gadolinium-...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000227

    authors: Radbruch A,Weberling LD,Kieslich PJ,Hepp J,Kickingereder P,Wick W,Schlemmer HP,Bendszus M

    更新日期:2015-12-01 00:00:00

  • Trabecular bone structure of the distal radius, the calcaneus, and the spine: which site predicts fracture status of the spine best?

    abstract:RATIONALE AND OBJECTIVES:To compare trabecular bone structure measures obtained in magnetic resonance images of the distal radius and the calcaneus as well as computed tomographic images of the spine versus bone mineral density (BMD) of the spine and the calcaneus in the prediction of osteoporotic spine fracture status...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/01.rli.0000129154.50654.4e

    authors: Link TM,Bauer J,Kollstedt A,Stumpf I,Hudelmaier M,Settles M,Majumdar S,Lochmüller EM,Eckstein F

    更新日期:2004-08-01 00:00:00

  • Minimal spinal hyperostosis with low-dose isotretinoin therapy.

    abstract::Skeletal abnormalities have been reported on numerous occasions in patients who have received high doses of vitamin A and its derivatives. Recently, a new derivative, isotretinoin (Accutane, Hoffman-LaRoche, Inc.), has become available for the treatment of cystic acne. Ninety-six patients treated for a minimum of four...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198601000-00007

    authors: Kilcoyne RF,Cope R,Cunningham W,Nardella FA,Denman S,Franz TJ,Hanifin J

    更新日期:1986-01-01 00:00:00

  • Comparison of Fenestra VC Contrast-enhanced computed tomography imaging with gadopentetate dimeglumine and ferucarbotran magnetic resonance imaging for the in vivo evaluation of murine liver damage after ischemia and reperfusion.

    abstract:OBJECTIVES:Comparison of intravenous Fenestra VC-enhanced computed tomography (CT) with gadopentetate dimeglumine and Ferucarbotran contrast-enhanced magnetic resonance imaging (MRI) for the in vivo imaging of hepatic ischemia/reperfusion injury (IRI) in a murine model. MATERIAL AND METHODS:After induction of hepatic ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e318155aa2e

    authors: Choukèr A,Lizak M,Schimel D,Helmberger T,Ward JM,Despres D,Kaufmann I,Bruns C,Löhe F,Ohta A,Sitkovsky MV,Klaunberg B,Thiel M

    更新日期:2008-02-01 00:00:00