Abstract:
:Radiolabeled ioversol was injected intravenously into two male and two female beagle dogs (6.7 to 10.4 kg) at two dose levels each (0.2 and 1.0 g I/kg). Blood levels of radioactivity were monitored at 2, 5, 10, 20, 40, 60, 90, and 120 minutes and at one and two days. Urine and feces were collected in metabolism cages for two days, at the end of which the dogs were killed and organs or tissues (kidneys, liver, spleen, lungs, thyroid glands, heart, gonads, and muscle) were sampled. Radioactivity in tissues and excreta was assayed. Biexponential disappearance of radioactivity from blood was observed in three of four dogs at each dose level. Distribution half-lives averaged 2.5 to 3.5 minutes. Elimination half-lives averaged 51 to 54 minutes. Volumes of distribution averaged 25% to 27% of body weight. No organ retention was evident at 48 hours. Recovery of ioversol in urine and feces averaged 86% to 88% of the administered dose, of which all but a few percent was recovered in urine. On chromatographic assay, ioversol accounted for an average of 103% to 109% of radioiodine, suggesting, within the experimental limits of the assay, that ioversol is excreted unchanged. No dose-related differences were evident in any of these measures. The pharmacokinetics and biodistribution of ioversol are consistent with those of other extracellularly distributed iodinated contrast agents that are excreted by the kidney.
journal_name
Invest Radioljournal_title
Investigative radiologyauthors
Coveney JR,Robbins MSdoi
10.1097/00004424-198906001-00005subject
Has Abstractpub_date
1989-06-01 00:00:00pages
S23-7eissn
0020-9996issn
1536-0210journal_volume
24 Suppl 1pub_type
杂志文章abstract:OBJECTIVE:To evaluate the effectiveness of a dual magnetic resonance-near infrared fluorescence optical imaging agent, poly(l-glutamic acid)-DTPA-Gd-NIR813, for both preoperative and intraoperative visualization and characterization of sentinel lymph nodes (SLN) in mice. MATERIALS AND METHODS:Poly(L-glutamic acid) was...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0b013e31804f5a79
更新日期:2007-08-01 00:00:00
abstract:AIM:: We sought to improve the clinical interpretation of first-pass myocardial magnetic resonance perfusion. Parametric analyses of the myocardial distribution of the contrast agent have been proposed. The objective of the present study was to compare the effectiveness of visual analysis and of a parametric approach i...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/01.rli.0000197980.89673.4b
更新日期:2006-04-01 00:00:00
abstract:OBJECTIVES:The objectives of this study were to test the feasibility of an investigational dual-channel next-generation endorectal coil (NG-ERC) in vivo, to quantitatively assess signal-to-noise ratio (SNR), and to get an impression of image quality compared with the current clinically available single-loop endorectal ...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0b013e3182a56678
更新日期:2014-01-01 00:00:00
abstract::Virtually all receiver operating characteristic (ROC) studies of medical imaging methods have involved data collected on a discrete confidence-rating scale, though in principle ROC studies can be conducted with either discrete or continuous scales. Continuous scales provide potential advantages in medical applications...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199202000-00016
更新日期:1992-02-01 00:00:00
abstract:OBJECTIVE:The purpose of this study was to assess the diagnostic value and safety of the contrast agent gadoterate meglumine (Gd-DOTA, DOTAREM, Guerbet, Roissy CdG Cedex, France) in the setting of a postmarketing surveillance study. MATERIALS AND METHODS:Between January 2004 and October 2005, radiologists in 61 radiol...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/01.rli.0000248893.01067.e5
更新日期:2007-01-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:To develop a new animal model for the evaluation of the renal tolerance of contrast agent and its application to diatrizoate and iotrolan injections in comparison to saline and mannitol solution. MATERIALS AND METHODS:The nephrotoxic potential of intravenously injected contrast agents in Beagl...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/01.rli.0000087096.61127.13
更新日期:2003-11-01 00:00:00
abstract:PURPOSE:We aimed to determine whether diffusion-weighted magnetic resonance imaging, by means of the apparent diffusion coefficient (ADC), is able to guide magnetic resonance-guided biopsy in patients fit for active surveillance (AS) and identify patients harboring high-grade Gleason components not suitable for AS. MA...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0b013e31827b711e
更新日期:2013-03-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:The influence of lipiodol injection on hepatic morphology and function was investigated in 119 rabbits with hepatic VX2 tumors. METHODS:The rabbits were divided into the following three groups, according to the materials injected via the proper hepatic artery: group 1 received doxorubicin (Adr...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199302000-00009
更新日期:1993-02-01 00:00:00
abstract::Left ventricular volume has been measured with ultrafast computed tomography. However, the accuracy with which this can be done is unknown. We therefore imaged with ultrafast computed tomography 11 rectangular phantoms, 20 to 225 ml, and 17 left ventricular casts, 15 to 112 ml. Two observers planimetered serial tomogr...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199101000-00006
更新日期:1991-01-01 00:00:00
abstract:PURPOSE:To evaluate the feasibility of ex vivo ablation implementing a cryo-based internally cooled bipolar radiofrequency (RF) applicator and to determine the influence of power and gas pressure on the size and shape of the resulting ablation zones. MATERIALS AND METHODS:Two hundred twenty-five ablations were perform...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0b013e3181b66d11
更新日期:2009-12-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:To measure the hepatic uptake and biliary elimination kinetics of gadolinium (Gd)-EOB-DTPA in dogs. METHOD:Two groups of four beagles each were anesthetized and given an intravenous bolus of 25 mumol/kg or 250 mumol/kg of Gd-EOB-DTPA. Blood, hepatic bile, and urine were collected over 140 minu...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199604000-00005
更新日期:1996-04-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:Because of the complex relationships between the dynamic three-dimensional cardiac surface shape and its projected image, errors arise with the use of two-dimensional silhouettes to measure displacements of the heart. The character and frequency of such errors are examined. METHODS:A high-prec...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199403000-00004
更新日期:1994-03-01 00:00:00
abstract::A diatrizoate compound (Renografin-76) and low osmolality Hexabrix were compared in a double-blind study of 50 adults undergoing arteriographic examination. Subjective and objective assessment of pain reaction for each contrast injection rated lower overall for Hexabrix. Discomfort associated with Renografin was great...
journal_title:Investigative radiology
pub_type: 临床试验,杂志文章
doi:10.1097/00004424-198411001-00012
更新日期:1984-11-01 00:00:00
abstract:OBJECTIVES:The aim of this work was to quantitatively evaluate the pharmacokinetic pattern of Gd-EOB-DTPA in a model of isolated and perfused mouse liver by using magnetic resonance imaging (MRI) and monochromatic quantitative computed tomography (MQCT). MATERIALS AND METHODS:For MQCT, perfusions were realized with th...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/01.rli.0000174474.43772.58
更新日期:2005-09-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:To study cellular mechanisms that cause contrast media nephropathy, an in vitro system for proximal and distal tubular cells has been established to evaluate the influence of x-ray contrast media on tubular function. METHODS:Confluent cell cultures of the two renal cell lines, proximal tubule ...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199411000-00002
更新日期:1994-11-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:Two independent gold standards and diagnoses from three-dimensional computed tomography (CT) images were used to examine the possibility that craniosynostosis is a binary abnormality that potentially may be diagnosed without error. METHODS:Surgical reports, histology of excised sutures, and th...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199410000-00005
更新日期:1994-10-01 00:00:00
abstract::For magnetic resonance, the established class of intravenous contrast media is the gadolinium-based contrast agents. In the 3 decades since initial approval, these have proven in general to be very safe for human administration. However, in 2006, a devastating late adverse reaction to administration of the less stable...
journal_title:Investigative radiology
pub_type: 杂志文章,评审
doi:10.1097/RLI.0000000000000374
更新日期:2017-06-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:The capability of an indirect computed tomographic lymphography (CT-LG) using a nonionic monometric contrast medium iopamidol for visualizing breast lymphatic pathways was preliminarily tested. MATERIALS AND METHODS:In 10 female dogs, a total of 0.5 and 1 mL of undiluted iopamidol was injected...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-200302000-00002
更新日期:2003-02-01 00:00:00
abstract:OBJECTIVES:The aim of this study was to investigate the impact on metal artifacts and dose efficiency of using a tin filter in combination with high-energy threshold (TH) images of a photon-counting detector (PCD) computed tomography (CT) system. MATERIALS AND METHODS:A 3D-printed spine with pedicle screws was scanned...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0000000000000535
更新日期:2019-04-01 00:00:00
abstract::An ultrasound phantom was constructed simulating fetal femurs in amniotic fluid. Bones of 26, 36, 50, 58, and 70 mm, representative of gestational ages ranging from 17 to 36 weeks, were scanned with mechanical sector, phased sector, and linear array systems (ATL, Diasonics, Acuson, and GE). Measurements were made with...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198505000-00016
更新日期:1985-05-01 00:00:00
abstract::The sonographic appearance of kidneys in patients presenting with acute renal failure due to hemolytic-uremic syndrome (HUS) was evaluated and compared with that in an age-matched control series. In nine patients with HUS, the renal cortex was typically hyperechogenic and the renal pyramids appeared sonolucent. The re...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198607000-00006
更新日期:1986-07-01 00:00:00
abstract::Lymphangiograms of canine cardiac and pulmonary efferent mediastinal lymphatics were made by cannulation and injection of Ethiodol. Injections were made singly and serially. The mediastinal lymphatics and lymph nodes, which constitute the pathways of drainage of the heart and lungs, were delineated from the point of c...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-197901000-00012
更新日期:1979-01-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:The authors developed a two-dimensional breathhold magnetic resonance (MR) technique for the direct imaging of pulmonary emboli. METHODS:In vitro MR imaging was performed to demonstrate the potential generation of clot-blood contrast by in vivo pulmonary embolism (PE). A two-dimensional magnet...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199708000-00001
更新日期:1997-08-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:To compare the diagnostic efficacy of a standard dose of MRI contrast agent in the evaluation of primary brain tumors and metastases using a high-field 3 tesla MR unit versus a 1.5 tesla MR unit. METHODS:Sixteen patients with brain tumors were examined at both field strengths using identical a...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-200203000-00003
更新日期:2002-03-01 00:00:00
abstract::A considerable amount of concern has been felt recently for the risk of carcinogenesis from x-rays to scoliosis patients. This paper re-evaluates risk in quantitative terms by using some data measured by us and other data recently published in the literature. The risks are considerably smaller than had been estimated ...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198401000-00014
更新日期:1984-01-01 00:00:00
abstract:OBJECTIVE:We sought to evaluate the influence of tube voltage on the visualization of acute myocardial infarction (MI) in cardiac multislice spiral computed tomography (MSCT). MATERIALS AND METHODS:Acute MI was induced in 12 domestic pigs by a 45-minute balloon occlusion of the left anterior descending artery. Delayed...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/01.rli.0000251577.68223.84
更新日期:2007-02-01 00:00:00
abstract:OBJECTIVE:The aim of this study was to compare changes in the signal intensity (SI) ratio of the dentate nucleus (DN) to the pons, DN to cerebrospinal fluid (CSF), and globus pallidus (GP) to thalamus on unenhanced T1-weighted magnetic resonance imaging (MRI) scans after serial injections of the macrocyclic gadolinium-...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0000000000000227
更新日期:2015-12-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:To compare trabecular bone structure measures obtained in magnetic resonance images of the distal radius and the calcaneus as well as computed tomographic images of the spine versus bone mineral density (BMD) of the spine and the calcaneus in the prediction of osteoporotic spine fracture status...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/01.rli.0000129154.50654.4e
更新日期:2004-08-01 00:00:00
abstract::Skeletal abnormalities have been reported on numerous occasions in patients who have received high doses of vitamin A and its derivatives. Recently, a new derivative, isotretinoin (Accutane, Hoffman-LaRoche, Inc.), has become available for the treatment of cystic acne. Ninety-six patients treated for a minimum of four...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198601000-00007
更新日期:1986-01-01 00:00:00
abstract:OBJECTIVES:Comparison of intravenous Fenestra VC-enhanced computed tomography (CT) with gadopentetate dimeglumine and Ferucarbotran contrast-enhanced magnetic resonance imaging (MRI) for the in vivo imaging of hepatic ischemia/reperfusion injury (IRI) in a murine model. MATERIAL AND METHODS:After induction of hepatic ...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0b013e318155aa2e
更新日期:2008-02-01 00:00:00