Abstract:
OBJECTIVES:Comparison of intravenous Fenestra VC-enhanced computed tomography (CT) with gadopentetate dimeglumine and Ferucarbotran contrast-enhanced magnetic resonance imaging (MRI) for the in vivo imaging of hepatic ischemia/reperfusion injury (IRI) in a murine model. MATERIAL AND METHODS:After induction of hepatic IRI by left liver lobe (LLL) ischemia (30, 45, and 75 minutes) and reperfusion (4 hours and 24 hours), a total of 130 mice were imaged either by Fenestra VC-enhanced 3-D CT or by dynamic, T1-weighed gadopentetate dimeglumine or static, T2*-weighed Ferucarbotran 2-D MRI (4.7 T). RESULTS:Detection of liver tissue damage as a consequence of IRI was not possible by CT or MRI without the use of contrast media. (1) Mice subjected to liver IRI (45 minutes of ischemia) and injected with Fenestra VC showed a distinct liver enhancement of the viable liver tissue or a nonenhancement of the necrotic tissue. The Fenestra VC CT-unenhanced liver volume increased as a function of time of ischemia and reperfusion. The unenhanced liver volume also correlated positively with serum liver enzyme activities and damage scores from liver histology. (2) The signal intensities (SI) between normal liver tissue and livers subjected to 30 minutes of ischemia were not different on dynamic gadopentetate dimeglumine-enhanced magnetic resonance images. More severe IRI as induced by 45 or 75 minutes of ischemia was characterized by (a) early hyperenhancement of regions in the LLL with rapid increase of SI higher than that observed in the undamaged liver within the first few minutes and (b) delayed hyperenhancement in the later course after gadopentetate dimeglumine injection, respectively. (3) Ferucarbotran MRI detected signs of IRI after only 30 minutes of liver ischemia and hence detected IRI earlier than Fenestra VC or gadopentetate dimeglumine. With longer duration of ischemia, Ferucarbotran SI increased in the LLL, but viable and necrotic tissues were not clearly distinguishable. CONCLUSIONS:MicroCT with Fenestra VC enhancement and MRI using either gadopentetate dimeglumine or Ferucarbotran enhancement of the liver revealed that all techniques allow in vivo determination of hepatic IRI as a function of the duration of ischemia and reperfusion of the liver. However, Fenestra VC-enhanced CT of the murine liver is superior to gadopentetate dimeglumine and Ferucarbotran for localization, quantification, and differentiation of viable from metabolically inactive/damaged liver tissue after hepatic ischemia/reperfusion but Fenestra VC is less sensitive than Ferucarbotran to detect the early onset of subtle consequences of hepatic IRI.
journal_name
Invest Radioljournal_title
Investigative radiologyauthors
Choukèr A,Lizak M,Schimel D,Helmberger T,Ward JM,Despres D,Kaufmann I,Bruns C,Löhe F,Ohta A,Sitkovsky MV,Klaunberg B,Thiel Mdoi
10.1097/RLI.0b013e318155aa2esubject
Has Abstractpub_date
2008-02-01 00:00:00pages
77-91issue
2eissn
0020-9996issn
1536-0210pii
00004424-200802000-00001journal_volume
43pub_type
杂志文章abstract:OBJECTIVE:The purpose of this study was to assess the effects of gadolinium (Gd3+), provided as gadolinium chloride, on fibroblast function. MATERIALS AND METHODS:Human dermal fibroblasts in monolayer culture and intact skin in organ culture were exposed to the lanthanide metal (1-20 μM). RESULTS:Increased proliferat...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0b013e3181e943d2
更新日期:2010-12-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:To evaluate the feasibility of mechanical thrombectomy in occluded hemodialysis access shunts by using a newly developed 5F pigtail rotation catheter. METHODS:Thrombosed hemodialysis access shunts were simulated by clotted bovine blood in silicone tubing (diameter 6 mm). After retrograde and a...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199907000-00008
更新日期:1999-07-01 00:00:00
abstract:RATIONALE AND OBJECTIVE:The authors performed a retrospective study in ultrasound to investigate new aspects in the sonomorphology of lymph node metastases of the neck. In this study, it could be demonstrated the first time that the histologic characteristics of the metastases determine the sonographic appearance. In a...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199609000-00001
更新日期:1996-09-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:The ventral sacroiliac ligament (VSL), which bridges the sacroiliac (SI) joint anteriorly, has been described as an important stabilizing structure of the joint, but no data exist regarding its assessment with routine and advanced imaging methods. The authors determine the imaging appearance of...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199608000-00009
更新日期:1996-08-01 00:00:00
abstract:PURPOSE:The purpose of this study was to evaluate image quality of a spectral photon-counting detector (PCD) computed tomography (CT) system for evaluation of major arteries of the head and neck compared with conventional single-energy CT scans using energy-integrating detectors (EIDs). METHODS:In this institutional r...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0000000000000418
更新日期:2018-03-01 00:00:00
abstract::The feasibility of control of traumatic hepatic hemorrhage by angiographic transcatheter embolization was investigated. Bleeding sites were created in the livers of each of twelve dogs, and the hepatic artery was occluded with Gelfoam. Successful control of bleeding was demonstrated by postembolization angiography in ...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-197801000-00014
更新日期:1978-01-01 00:00:00
abstract:OBJECTIVES:The aim of this study was to achieve initial experience with non-contrast-enhanced (ne) magnetic resonance angiography (MRA) of the lower leg arteries in patients with peripheral arterial occlusive disease (PAOD) at 7 T. MATERIALS AND METHODS:Seven patients with PAOD were examined on a 7-T whole-body magnet...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0000000000000044
更新日期:2014-05-01 00:00:00
abstract:PURPOSE:We sought to develop a robotic system for computed tomography (CT)-guided biopsy to validate the feasibility, accuracy, and efficacy of the system using phantom tests. MATERIALS AND METHODS:Ten peas (mean diameter 9.9+/-0.4 mm) embedded within a gel phantom were selected for biopsy. Once the best access was de...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/01.rli.0000155285.05672.cf
更新日期:2005-04-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:To investigate postmortem metabolic and morphologic alterations in the dog brain thalamus and to contribute diagnostic aids in medicolegal science. METHODS:A homogeneous group of 17 dogs was used for in vivo 1H magnetic resonance (MR) spectroscopy and electron microscopic studies, which were p...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199505000-00001
更新日期:1995-05-01 00:00:00
abstract::The results of an in vitro mixed hemadsorption (MHA) assay predicted the success of in vivo tumor localization using a radioiodinated, monoclonal, IgG1 antibody (A2) with reactivity to the human bladder carcinoma cell line RT4. In vitro, murine monoclonal antibodies A2 and G6, demonstrated reactivity to RT4 with titer...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198411000-00011
更新日期:1984-11-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:The basic characteristics of BR1, a novel echo contrast agent based on stabilized sulfur hexafluoride (SF6) microbubbles have been evaluated. METHODS:The authors determined the physicochemical properties (bubble concentration, bubble size distribution, resistance to pressure, and stability) an...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199508000-00001
更新日期:1995-08-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:Our purpose was to validate contrast-enhanced computed tomography (CECT)-derived quantitative measures of perfusion and permeability against gold standard techniques of fluorescent microspheres and Evan's Blue dye, respectively. MATERIALS AND METHODS:Normal and tumor-bearing (R3230AC) Fischer ...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/01rli.0000124456.82985.35
更新日期:2004-06-01 00:00:00
abstract::Chest radiographs are commonly obtained to assess children for bronchiolitis, both to corroborate the diagnosis and to exclude other diagnostic possibilities. Their utility in this setting has not previously been examined. Using a blinded, randomized study design, we examined the interobserver and intraobserver variat...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199102000-00004
更新日期:1991-02-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:The object of this study was to determine by flow cytometry the cellular and DNA content of the washings of core biopsy samples and needles obtained during stereotactic core biopsies of clinically occult suspicious lesions. METHODS:Fourteen-gauge core multipass biopsy inner-needle saline washi...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199801000-00008
更新日期:1998-01-01 00:00:00
abstract::The effects of an intravenously administered nitroxyl spin label (PCA) on the magnetic resonance imaging (MRI) appearance and relaxation times of acute canine myocardial infarctions were studied. Twenty-four hours after ligation of the left anterior descending coronary artery (LAD), animals were either sacrificed imme...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:
更新日期:1985-09-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:The authors studied premenopausal, perimenopausal, and postmenopausal women to determine if ultrasound bone velocity (UBV) on proximal phalanges of women reflect bone changes related to gonadal status and age. METHODS:A total of 166 healthy women-64 postmenopausal women (mean age 58.7 +/- 9.4 ...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199701000-00011
更新日期:1997-01-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:The authors differentiate breast lesions on sonography by measurements in two compression states that are perpendicular to each other. METHODS:Diameters of 100 breast lesions were measured preoperatively under lateromedial and craniocaudal compression with a new sonographic method. This method...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199607000-00003
更新日期:1996-07-01 00:00:00
abstract:OBJECTIVES:The aim of this study was to compare a compressed-sensing free-breathing VIBE (fbVIBE) with a conventional breath-hold VIBE (bhVIBE) for dynamic contrast-enhanced imaging of the upper abdomen. MATERIALS AND METHODS:In total, 70 datasets (bhVIBE, n = 30; fbVIBE n = 40; hard-gated [hg] reconstruction, n = 30;...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0000000000000607
更新日期:2019-11-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:To measure the hepatic uptake and biliary elimination kinetics of gadolinium (Gd)-EOB-DTPA in dogs. METHOD:Two groups of four beagles each were anesthetized and given an intravenous bolus of 25 mumol/kg or 250 mumol/kg of Gd-EOB-DTPA. Blood, hepatic bile, and urine were collected over 140 minu...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199604000-00005
更新日期:1996-04-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:To compare technical aspects and neointima formation of a new Nitinol stent and a Wallstent. METHODS:A Nitinol sten and a Wallstent were placed into the iliac arteries of 14 sheep (total of 28 stents) and followed angiographically. Seven sheep were killed after 1 month and 7 after 4.5 months. ...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199507000-00004
更新日期:1995-07-01 00:00:00
abstract:OBJECTIVES:The aim of this study was to compare the prognostic utility of a staging system using magnetic resonance imaging (MRI) with the seventh American Joint Committee on Cancer (AJCC) staging system in patients with hepatocellular carcinoma (HCC) who underwent hepatic resection. MATERIALS AND METHODS:A total of 1...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0b013e3182630e8d
更新日期:2012-11-01 00:00:00
abstract:OBJECTIVE:To compare image quality and geometric distortion between readout-segmented diffusion-weighted imaging (rs-DWI) and selective-excitation accelerated reduced-field of view (FOV) DWI (sTX-DWI) of the prostate. MATERIALS AND METHODS:Sixty-five patients underwent 3-T MRI of the prostate including rs-DWI and sTX-...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0000000000000184
更新日期:2015-11-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:To investigate the capacity of manganese dipyridoxyl diphosphate (MnDPDP)-enhanced magnetic resonance imaging (MRI) to discriminate the injured myocardium from the normal myocardium in a cat model. MATERIALS AND METHODS:Fourteen cats were prepared for acute myocardial infarction with 90-minute...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:
更新日期:2005-01-01 00:00:00
abstract::The authors correlated sonographic findings with histologic findings in a rabbit model of osteomyelitis. Staphylococcus aureus osteomyelitis was induced in the femora of 11 New Zealand white rabbits. The opposite leg was used as a control. Sonographic findings showed fluid adjacent to the bone in 11 cases. The fluid w...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199202000-00002
更新日期:1992-02-01 00:00:00
abstract:OBJECTIVES:The aim of this study was to quantify image quality gains of a moving coronary plaque phantom using dual-source computed tomography (DSCT) providing 83 milliseconds temporal resolution in direct comparison to 64 slice single-source multidetector CT (MDCT) with a temporal resolution of 165 milliseconds. MATE...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/01.rli.0000254409.79193.96
更新日期:2007-03-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:Magnetic resonance imaging (MRI) techniques seem to be very promising for 3D dosimetry studies, but long imaging acquisition time limits their use. A new fast T1 mapping protocol, easy to implement on a conventional MR imager, has been used to determine dose distributions on Fricke gels. METHO...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199903000-00014
更新日期:1999-03-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:In contrast-enhanced dual-energy subtraction imaging 2 images acquired postcontrast media administration at different energies are subtracted to highlight structures hidden in the absence of contrast media. X-ray spectra of the newly developed digital full-field mammography units (GE Senographe...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/01.RLI.0000077124.24140.bd
更新日期:2003-09-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:Very small dextran-coated magnetite particles were developed. These particles can be used either as immunospecific contrast agents for MRI by coupling to antibodies or as an interstitial contrast agent. METHODS:The particles were synthesized from iron chloride/dextran solutions. Size was evalu...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-200009000-00006
更新日期:2000-09-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:Hepatocellular carcinomas (HCCs) usually consist of components of different histologic grade. Using surgically resected specimens, the authors obtained high-resolution magnetic resonance (MR) images and studied the relationship between histologic grade of HCCs and MR signal intensity. METHOD:I...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199308000-00007
更新日期:1993-08-01 00:00:00
abstract::The authors reexamined a suspected difference in the effects of clinical information upon detection of nodules vs. more diverse lesions by directly incorporating classification specificity into detection ROC analysis. Categorical prompts, correct for specific abnormalities, led to detection superior to unprompted read...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198801000-00011
更新日期:1988-01-01 00:00:00