Comparison of Fenestra VC Contrast-enhanced computed tomography imaging with gadopentetate dimeglumine and ferucarbotran magnetic resonance imaging for the in vivo evaluation of murine liver damage after ischemia and reperfusion.

Abstract:

OBJECTIVES:Comparison of intravenous Fenestra VC-enhanced computed tomography (CT) with gadopentetate dimeglumine and Ferucarbotran contrast-enhanced magnetic resonance imaging (MRI) for the in vivo imaging of hepatic ischemia/reperfusion injury (IRI) in a murine model. MATERIAL AND METHODS:After induction of hepatic IRI by left liver lobe (LLL) ischemia (30, 45, and 75 minutes) and reperfusion (4 hours and 24 hours), a total of 130 mice were imaged either by Fenestra VC-enhanced 3-D CT or by dynamic, T1-weighed gadopentetate dimeglumine or static, T2*-weighed Ferucarbotran 2-D MRI (4.7 T). RESULTS:Detection of liver tissue damage as a consequence of IRI was not possible by CT or MRI without the use of contrast media. (1) Mice subjected to liver IRI (45 minutes of ischemia) and injected with Fenestra VC showed a distinct liver enhancement of the viable liver tissue or a nonenhancement of the necrotic tissue. The Fenestra VC CT-unenhanced liver volume increased as a function of time of ischemia and reperfusion. The unenhanced liver volume also correlated positively with serum liver enzyme activities and damage scores from liver histology. (2) The signal intensities (SI) between normal liver tissue and livers subjected to 30 minutes of ischemia were not different on dynamic gadopentetate dimeglumine-enhanced magnetic resonance images. More severe IRI as induced by 45 or 75 minutes of ischemia was characterized by (a) early hyperenhancement of regions in the LLL with rapid increase of SI higher than that observed in the undamaged liver within the first few minutes and (b) delayed hyperenhancement in the later course after gadopentetate dimeglumine injection, respectively. (3) Ferucarbotran MRI detected signs of IRI after only 30 minutes of liver ischemia and hence detected IRI earlier than Fenestra VC or gadopentetate dimeglumine. With longer duration of ischemia, Ferucarbotran SI increased in the LLL, but viable and necrotic tissues were not clearly distinguishable. CONCLUSIONS:MicroCT with Fenestra VC enhancement and MRI using either gadopentetate dimeglumine or Ferucarbotran enhancement of the liver revealed that all techniques allow in vivo determination of hepatic IRI as a function of the duration of ischemia and reperfusion of the liver. However, Fenestra VC-enhanced CT of the murine liver is superior to gadopentetate dimeglumine and Ferucarbotran for localization, quantification, and differentiation of viable from metabolically inactive/damaged liver tissue after hepatic ischemia/reperfusion but Fenestra VC is less sensitive than Ferucarbotran to detect the early onset of subtle consequences of hepatic IRI.

journal_name

Invest Radiol

journal_title

Investigative radiology

authors

Choukèr A,Lizak M,Schimel D,Helmberger T,Ward JM,Despres D,Kaufmann I,Bruns C,Löhe F,Ohta A,Sitkovsky MV,Klaunberg B,Thiel M

doi

10.1097/RLI.0b013e318155aa2e

subject

Has Abstract

pub_date

2008-02-01 00:00:00

pages

77-91

issue

2

eissn

0020-9996

issn

1536-0210

pii

00004424-200802000-00001

journal_volume

43

pub_type

杂志文章
  • Fibroblast response to gadolinium: role for platelet-derived growth factor receptor.

    abstract:OBJECTIVE:The purpose of this study was to assess the effects of gadolinium (Gd3+), provided as gadolinium chloride, on fibroblast function. MATERIALS AND METHODS:Human dermal fibroblasts in monolayer culture and intact skin in organ culture were exposed to the lanthanide metal (1-20 μM). RESULTS:Increased proliferat...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e3181e943d2

    authors: Bhagavathula N,Dame MK,DaSilva M,Jenkins W,Aslam MN,Perone P,Varani J

    更新日期:2010-12-01 00:00:00

  • Mechanical thrombectomy in hemodialysis access shunts using a 5F pigtail rotation catheter. In vitro and in vivo investigations.

    abstract:RATIONALE AND OBJECTIVES:To evaluate the feasibility of mechanical thrombectomy in occluded hemodialysis access shunts by using a newly developed 5F pigtail rotation catheter. METHODS:Thrombosed hemodialysis access shunts were simulated by clotted bovine blood in silicone tubing (diameter 6 mm). After retrograde and a...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199907000-00008

    authors: Wildberger J,Schmitz-Rode T,Wein BB,Günther RW

    更新日期:1999-07-01 00:00:00

  • Keratinization and necrosis. Morphologic aspects of lymphatic metastases in ultrasound.

    abstract:RATIONALE AND OBJECTIVE:The authors performed a retrospective study in ultrasound to investigate new aspects in the sonomorphology of lymph node metastases of the neck. In this study, it could be demonstrated the first time that the histologic characteristics of the metastases determine the sonographic appearance. In a...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199609000-00001

    authors: Mäurer J,Willam C,Steinkamp HJ,Knollmann FD,Felix R

    更新日期:1996-09-01 00:00:00

  • Ventral sacroiliac ligament. Anatomic and pathologic considerations.

    abstract:RATIONALE AND OBJECTIVES:The ventral sacroiliac ligament (VSL), which bridges the sacroiliac (SI) joint anteriorly, has been described as an important stabilizing structure of the joint, but no data exist regarding its assessment with routine and advanced imaging methods. The authors determine the imaging appearance of...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199608000-00009

    authors: Jaovisidha S,Ryu KN,De Maeseneer M,Haghighi P,Goodwin D,Sartoris DJ,Resnick D

    更新日期:1996-08-01 00:00:00

  • Photon-Counting Computed Tomography for Vascular Imaging of the Head and Neck: First In Vivo Human Results.

    abstract:PURPOSE:The purpose of this study was to evaluate image quality of a spectral photon-counting detector (PCD) computed tomography (CT) system for evaluation of major arteries of the head and neck compared with conventional single-energy CT scans using energy-integrating detectors (EIDs). METHODS:In this institutional r...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000418

    authors: Symons R,Reich DS,Bagheri M,Cork TE,Krauss B,Ulzheimer S,Kappler S,Bluemke DA,Pourmorteza A

    更新日期:2018-03-01 00:00:00

  • Control of experimental traumatic hepatic hemorrhage by transcatheter embolization.

    abstract::The feasibility of control of traumatic hepatic hemorrhage by angiographic transcatheter embolization was investigated. Bleeding sites were created in the livers of each of twelve dogs, and the hepatic artery was occluded with Gelfoam. Successful control of bleeding was demonstrated by postembolization angiography in ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-197801000-00014

    authors: Tyler T,Rosenbaum HD

    更新日期:1978-01-01 00:00:00

  • Initial evaluation of non-contrast-enhanced magnetic resonance angiography in patients with peripheral arterial occlusive disease at 7 T.

    abstract:OBJECTIVES:The aim of this study was to achieve initial experience with non-contrast-enhanced (ne) magnetic resonance angiography (MRA) of the lower leg arteries in patients with peripheral arterial occlusive disease (PAOD) at 7 T. MATERIALS AND METHODS:Seven patients with PAOD were examined on a 7-T whole-body magnet...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000044

    authors: Fischer A,Maderwald S,Johst S,Orzada S,Ladd ME,Umutlu L,Lauenstein TC,Kniemeyer HW,Nassenstein K

    更新日期:2014-05-01 00:00:00

  • Robot-assisted biopsy using computed tomography-guidance: initial results from in vitro tests.

    abstract:PURPOSE:We sought to develop a robotic system for computed tomography (CT)-guided biopsy to validate the feasibility, accuracy, and efficacy of the system using phantom tests. MATERIALS AND METHODS:Ten peas (mean diameter 9.9+/-0.4 mm) embedded within a gel phantom were selected for biopsy. Once the best access was de...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/01.rli.0000155285.05672.cf

    authors: Kettenbach J,Kronreif G,Figl M,Fürst M,Birkfellner W,Hanel R,Ptacek W,Bergmann H

    更新日期:2005-04-01 00:00:00

  • Postmortem metabolic and morphologic alterations of the dog brain thalamus with use of in vivo 1H magnetic resonance spectroscopy and electron microscopy.

    abstract:RATIONALE AND OBJECTIVES:To investigate postmortem metabolic and morphologic alterations in the dog brain thalamus and to contribute diagnostic aids in medicolegal science. METHODS:A homogeneous group of 17 dogs was used for in vivo 1H magnetic resonance (MR) spectroscopy and electron microscopic studies, which were p...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199505000-00001

    authors: Choe BY,Gil HJ,Suh TS,Shinn KS

    更新日期:1995-05-01 00:00:00

  • Radioimmunodetection of a transplantable human bladder carcinoma in a nude mouse.

    abstract::The results of an in vitro mixed hemadsorption (MHA) assay predicted the success of in vivo tumor localization using a radioiodinated, monoclonal, IgG1 antibody (A2) with reactivity to the human bladder carcinoma cell line RT4. In vitro, murine monoclonal antibodies A2 and G6, demonstrated reactivity to RT4 with titer...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198411000-00011

    authors: Gross MD,Skinner RW,Grossman HB

    更新日期:1984-11-01 00:00:00

  • BR1: a new ultrasonographic contrast agent based on sulfur hexafluoride-filled microbubbles.

    abstract:RATIONALE AND OBJECTIVES:The basic characteristics of BR1, a novel echo contrast agent based on stabilized sulfur hexafluoride (SF6) microbubbles have been evaluated. METHODS:The authors determined the physicochemical properties (bubble concentration, bubble size distribution, resistance to pressure, and stability) an...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199508000-00001

    authors: Schneider M,Arditi M,Barrau MB,Brochot J,Broillet A,Ventrone R,Yan F

    更新日期:1995-08-01 00:00:00

  • Quantitative evaluation of perfusion and permeability of peripheral tumors using contrast-enhanced computed tomography.

    abstract:RATIONALE AND OBJECTIVES:Our purpose was to validate contrast-enhanced computed tomography (CECT)-derived quantitative measures of perfusion and permeability against gold standard techniques of fluorescent microspheres and Evan's Blue dye, respectively. MATERIALS AND METHODS:Normal and tumor-bearing (R3230AC) Fischer ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/01rli.0000124456.82985.35

    authors: Pollard RE,Garcia TC,Stieger SM,Ferrara KW,Sadlowski AR,Wisner ER

    更新日期:2004-06-01 00:00:00

  • Observer variation in detecting the radiologic features associated with bronchiolitis.

    abstract::Chest radiographs are commonly obtained to assess children for bronchiolitis, both to corroborate the diagnosis and to exclude other diagnostic possibilities. Their utility in this setting has not previously been examined. Using a blinded, randomized study design, we examined the interobserver and intraobserver variat...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199102000-00004

    authors: Coblentz CL,Babcook CJ,Alton D,Riley BJ,Norman G

    更新日期:1991-02-01 00:00:00

  • Breast stereotactic core biopsy washings: abundant cell samples from clinically occult lesions for flow cytometric DNA analysis.

    abstract:RATIONALE AND OBJECTIVES:The object of this study was to determine by flow cytometry the cellular and DNA content of the washings of core biopsy samples and needles obtained during stereotactic core biopsies of clinically occult suspicious lesions. METHODS:Fourteen-gauge core multipass biopsy inner-needle saline washi...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199801000-00008

    authors: Stomper PC,Budnick RM,Stewart CC

    更新日期:1998-01-01 00:00:00

  • Magnetic resonance imaging of acute myocardial infarction using a nitroxyl spin label (PCA).

    abstract::The effects of an intravenously administered nitroxyl spin label (PCA) on the magnetic resonance imaging (MRI) appearance and relaxation times of acute canine myocardial infarctions were studied. Twenty-four hours after ligation of the left anterior descending coronary artery (LAD), animals were either sacrificed imme...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:

    authors: McNamara MT,Wesbey GE,Brasch RC,Sievers R,Lipton MJ,Higgins CB

    更新日期:1985-09-01 00:00:00

  • Ultrasound bone velocity on proximal phalanges in premenopausal, perimenopausal, and postmenopausal healthy women.

    abstract:RATIONALE AND OBJECTIVES:The authors studied premenopausal, perimenopausal, and postmenopausal women to determine if ultrasound bone velocity (UBV) on proximal phalanges of women reflect bone changes related to gonadal status and age. METHODS:A total of 166 healthy women-64 postmenopausal women (mean age 58.7 +/- 9.4 ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199701000-00011

    authors: Aguado F,Revilla M,Hernández ER,Villa LF,Rico H

    更新日期:1997-01-01 00:00:00

  • Differentiation of breast lesions by measurements under craniocaudal and lateromedial compression using a new sonographic method.

    abstract:RATIONALE AND OBJECTIVES:The authors differentiate breast lesions on sonography by measurements in two compression states that are perpendicular to each other. METHODS:Diameters of 100 breast lesions were measured preoperatively under lateromedial and craniocaudal compression with a new sonographic method. This method...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199607000-00003

    authors: Richter K,Willrodt RG,Opri F,Heywang-Köbrunner SH

    更新日期:1996-07-01 00:00:00

  • Free-Breathing Dynamic Contrast-Enhanced Imaging of the Upper Abdomen Using a Cartesian Compressed-Sensing Sequence With Hard-Gated and Motion-State-Resolved Reconstruction.

    abstract:OBJECTIVES:The aim of this study was to compare a compressed-sensing free-breathing VIBE (fbVIBE) with a conventional breath-hold VIBE (bhVIBE) for dynamic contrast-enhanced imaging of the upper abdomen. MATERIALS AND METHODS:In total, 70 datasets (bhVIBE, n = 30; fbVIBE n = 40; hard-gated [hg] reconstruction, n = 30;...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000607

    authors: Hausmann D,Niemann T,Kreul D,Nocito A,Klarhöfer M,Nickel DM,Kiefer B,Attenberger UI,Zöllner FG,Kubik-Huch RA

    更新日期:2019-11-01 00:00:00

  • Hepatic kinetics and magnetic resonance imaging of gadolinium-EOB-DTPA in dogs.

    abstract:RATIONALE AND OBJECTIVES:To measure the hepatic uptake and biliary elimination kinetics of gadolinium (Gd)-EOB-DTPA in dogs. METHOD:Two groups of four beagles each were anesthetized and given an intravenous bolus of 25 mumol/kg or 250 mumol/kg of Gd-EOB-DTPA. Blood, hepatic bile, and urine were collected over 140 minu...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199604000-00005

    authors: Benness G,Khangure M,Morris I,Warwick A,Burrows P,Vogler H,Weinmann HJ

    更新日期:1996-04-01 00:00:00

  • Experimental arterial stent placement. Comparison of a new Nitinol stent and Wallstent.

    abstract:RATIONALE AND OBJECTIVES:To compare technical aspects and neointima formation of a new Nitinol stent and a Wallstent. METHODS:A Nitinol sten and a Wallstent were placed into the iliac arteries of 14 sheep (total of 28 stents) and followed angiographically. Seven sheep were killed after 1 month and 7 after 4.5 months. ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199507000-00004

    authors: Schürmann K,Vorwerk D,Kulisch A,Stroehmer-Kulisch E,Biesterfeld S,Stopinski T,Günther RW

    更新日期:1995-07-01 00:00:00

  • Assessment of preoperative magnetic resonance imaging staging in patients with hepatocellular carcinoma undergoing resection compared with the seventh American Joint Committee on Cancer System.

    abstract:OBJECTIVES:The aim of this study was to compare the prognostic utility of a staging system using magnetic resonance imaging (MRI) with the seventh American Joint Committee on Cancer (AJCC) staging system in patients with hepatocellular carcinoma (HCC) who underwent hepatic resection. MATERIALS AND METHODS:A total of 1...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e3182630e8d

    authors: An C,Choi GH,Lee HS,Kim MJ

    更新日期:2012-11-01 00:00:00

  • Diffusion-Weighted Imaging of the Prostate: Image Quality and Geometric Distortion of Readout-Segmented Versus Selective-Excitation Accelerated Acquisitions.

    abstract:OBJECTIVE:To compare image quality and geometric distortion between readout-segmented diffusion-weighted imaging (rs-DWI) and selective-excitation accelerated reduced-field of view (FOV) DWI (sTX-DWI) of the prostate. MATERIALS AND METHODS:Sixty-five patients underwent 3-T MRI of the prostate including rs-DWI and sTX-...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000184

    authors: Barth BK,Cornelius A,Nanz D,Eberli D,Donati OF

    更新日期:2015-11-01 00:00:00

  • Manganese dipyridoxyl diphosphate (MnDPDP)-enhanced magnetic resonance imaging of acute reperfused myocardial injury in a cat model: part I: comparison with pathologic examination.

    abstract:RATIONALE AND OBJECTIVES:To investigate the capacity of manganese dipyridoxyl diphosphate (MnDPDP)-enhanced magnetic resonance imaging (MRI) to discriminate the injured myocardium from the normal myocardium in a cat model. MATERIALS AND METHODS:Fourteen cats were prepared for acute myocardial infarction with 90-minute...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:

    authors: Kim TH,Yang DH,Choi JW,Kim ST,Yoon JH,Shin JH,Seo JB,Gong GY,Lim TH

    更新日期:2005-01-01 00:00:00

  • Ultrasonic detection of osteomyelitis. Pathologic correlation in an animal model.

    abstract::The authors correlated sonographic findings with histologic findings in a rabbit model of osteomyelitis. Staphylococcus aureus osteomyelitis was induced in the femora of 11 New Zealand white rabbits. The opposite leg was used as a control. Sonographic findings showed fluid adjacent to the bone in 11 cases. The fluid w...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199202000-00002

    authors: Abiri MM,DeAngelis GA,Kirpekar M,Abou AN,Ablow RC

    更新日期:1992-02-01 00:00:00

  • Dual-source computed tomography: advances of improved temporal resolution in coronary plaque imaging.

    abstract:OBJECTIVES:The aim of this study was to quantify image quality gains of a moving coronary plaque phantom using dual-source computed tomography (DSCT) providing 83 milliseconds temporal resolution in direct comparison to 64 slice single-source multidetector CT (MDCT) with a temporal resolution of 165 milliseconds. MATE...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/01.rli.0000254409.79193.96

    authors: Reimann AJ,Rinck D,Birinci-Aydogan A,Scheuering M,Burgstahler C,Schroeder S,Brodoefel H,Tsiflikas I,Herberts T,Flohr T,Claussen CD,Kopp AF,Heuschmid M

    更新日期:2007-03-01 00:00:00

  • MRI dosimetry: a fast quantitative MRI method to determine 3D absorbed dose distributions.

    abstract:RATIONALE AND OBJECTIVES:Magnetic resonance imaging (MRI) techniques seem to be very promising for 3D dosimetry studies, but long imaging acquisition time limits their use. A new fast T1 mapping protocol, easy to implement on a conventional MR imager, has been used to determine dose distributions on Fricke gels. METHO...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199903000-00014

    authors: Calmet C,Vincensini D,Bonnet J,Bertino C,Catala A,Martinez M,Joffre F

    更新日期:1999-03-01 00:00:00

  • New contrast media designed for x-ray energy subtraction imaging in digital mammography.

    abstract:RATIONALE AND OBJECTIVES:In contrast-enhanced dual-energy subtraction imaging 2 images acquired postcontrast media administration at different energies are subtracted to highlight structures hidden in the absence of contrast media. X-ray spectra of the newly developed digital full-field mammography units (GE Senographe...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/01.RLI.0000077124.24140.bd

    authors: Lawaczeck R,Diekmann F,Diekmann S,Hamm B,Bick U,Press WR,Schirmer H,Schön K,Weinmann HJ

    更新日期:2003-09-01 00:00:00

  • Characterization of ultrasmall magnetite [correction of paramagnetic magnetite] particles as superparamagnetic contrast agents in MRI.

    abstract:RATIONALE AND OBJECTIVES:Very small dextran-coated magnetite particles were developed. These particles can be used either as immunospecific contrast agents for MRI by coupling to antibodies or as an interstitial contrast agent. METHODS:The particles were synthesized from iron chloride/dextran solutions. Size was evalu...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-200009000-00006

    authors: Grimm J,Karger N,Lüsse S,Winoto-Morbach S,Krisch B,Müller-Hülsbeck S,Heller M

    更新日期:2000-09-01 00:00:00

  • Magnetic resonance imaging-histologic correlation of small hepatocellular carcinomas adenomatous hyperplasias.

    abstract:RATIONALE AND OBJECTIVES:Hepatocellular carcinomas (HCCs) usually consist of components of different histologic grade. Using surgically resected specimens, the authors obtained high-resolution magnetic resonance (MR) images and studied the relationship between histologic grade of HCCs and MR signal intensity. METHOD:I...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199308000-00007

    authors: Inoue E,Kuroda C,Narumi Y,Fujita M,Kadota T,Kuriyama K,Yoshioka H,Ishiguro S,Sasaki Y,Imaoka S

    更新日期:1993-08-01 00:00:00

  • Influence of clinical history upon detection of nodules and other lesions.

    abstract::The authors reexamined a suspected difference in the effects of clinical information upon detection of nodules vs. more diverse lesions by directly incorporating classification specificity into detection ROC analysis. Categorical prompts, correct for specific abnormalities, led to detection superior to unprompted read...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198801000-00011

    authors: Berbaum KS,Franken EA Jr,Dorfman DD,Barloon TJ

    更新日期:1988-01-01 00:00:00