Manganese dipyridoxyl diphosphate (MnDPDP)-enhanced magnetic resonance imaging of acute reperfused myocardial injury in a cat model: part I: comparison with pathologic examination.

Abstract:

RATIONALE AND OBJECTIVES:To investigate the capacity of manganese dipyridoxyl diphosphate (MnDPDP)-enhanced magnetic resonance imaging (MRI) to discriminate the injured myocardium from the normal myocardium in a cat model. MATERIALS AND METHODS:Fourteen cats were prepared for acute myocardial infarction with 90-minute occlusion followed by 120-minute reperfusion. Inversion recovery gradient-recalled echo (IR-GRE) MR images were obtained at 60-minute intervals for 4 hours after the injection of MnDPDP, and ex vivo after the cats were killed. We evaluated the differences between the unenhanced area on the in vivo and ex vivo MR images and the unstained area on triphenyl tetrazolium chloride (TTC) staining. RESULTS:The unenhanced area on the in vivo MR images was well correlated with that on the ex vivo MR images. The unenhanced area on the ex vivo MR images was significantly larger than the unstained area on TTC staining. CONCLUSIONS:This study suggests that the MnDPDP-unenhanced area on the MR images includes not only the infarcted myocardium but also the stunned myocardium.

journal_name

Invest Radiol

journal_title

Investigative radiology

authors

Kim TH,Yang DH,Choi JW,Kim ST,Yoon JH,Shin JH,Seo JB,Gong GY,Lim TH

keywords:

subject

Has Abstract

pub_date

2005-01-01 00:00:00

pages

49-55

issue

1

eissn

0020-9996

issn

1536-0210

pii

00004424-200501000-00009

journal_volume

40

pub_type

杂志文章
  • Magnetic resonance imaging as a monitor of changes in the irradiated rat brain. An aid in determining the time course of events in a histologic study.

    abstract:RATIONALE AND OBJECTIVES:Optimal dose schedules and total dose of ionizing radiation for human central nervous system malignancy are not known. An animal model has been developed for the investigation of rat central nervous system response to proton irradiation using magnetic resonance imaging (MRI). A clinical MRI dev...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199504000-00003

    authors: Kennedy AS,Archambeau JO,Archambeau MH,Holshouser B,Thompson J,Moyers M,Hinshaw D Jr,Slater JM

    更新日期:1995-04-01 00:00:00

  • Personal computer needs for the radiologist.

    abstract::This article reviews the computer system hardware and software, applications programs, and computer network services that are available on microcomputers for use by the radiologist. The American College of Radiology Institute computer network is described, which is specifically designed to help the practicing radiolog...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198602000-00015

    authors: Newell JD,Hunter TB

    更新日期:1986-02-01 00:00:00

  • Robot-assisted biopsy using computed tomography-guidance: initial results from in vitro tests.

    abstract:PURPOSE:We sought to develop a robotic system for computed tomography (CT)-guided biopsy to validate the feasibility, accuracy, and efficacy of the system using phantom tests. MATERIALS AND METHODS:Ten peas (mean diameter 9.9+/-0.4 mm) embedded within a gel phantom were selected for biopsy. Once the best access was de...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/01.rli.0000155285.05672.cf

    authors: Kettenbach J,Kronreif G,Figl M,Fürst M,Birkfellner W,Hanel R,Ptacek W,Bergmann H

    更新日期:2005-04-01 00:00:00

  • A comparison of iopromide with iopamidol and iohexol for contrast-enhanced computed tomography.

    abstract:RATIONALE AND OBJECTIVES:Iopromide is a new monomeric, nonionic contrast agent that exhibits low osmolality and low viscosity in high concentration in aqueous solutions. Double-blind, randomized clinical trials have established the efficacy, safety, and tolerance of iopromide for excretory urography, coronary angiograp...

    journal_title:Investigative radiology

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1097/00004424-199405001-00015

    authors: Goldberg SN,Abrahams J,Drayer BP,Golding S,Bernardino M,Brunetti J

    更新日期:1994-05-01 00:00:00

  • Pyelovenous and pyelolymphatic backflow during retrograde pyelography in renal vein thrombosis.

    abstract::Pyelovenous and pyelolymphatic backflow have been observed during retrograde pyelography in three patients with renal vein thrombosis. The radiographic patterns of backflow following experimental unilateral renal vein occlusion in rabbits were analyzed and correlated with the clinical findings. Capsular, perihilar, pe...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198101000-00003

    authors: Bidgood WD Jr,Cuttino JT Jr,Clark RL,Volberg FM

    更新日期:1981-01-01 00:00:00

  • Microcomputer-based technique for 3-D reconstruction and volume measurement of computer tomographic images. Part 1: Phantom studies.

    abstract::This paper presents a microcomputer-based technique that accurately quantifies volumes from computed tomographic (CT) scans of irregularly shaped objects as well as displaying 3-D reconstructions. The method uses standard CT film, allowing analysis of previous or outside CT studies. The planimetry method showed less t...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198812000-00001

    authors: Albright RE Jr,Fram EK

    更新日期:1988-12-01 00:00:00

  • A method for the study of regional ischemic dysfunction in the intact dog. Permanent endocardial markers and the pressure-length loop.

    abstract::A radiographic method for use in the closed-chest dog is described which allows the quantitation of segmental mechanical performance. Previous work has shown that the area of the pressure-length loop (an approximation of a stress-strain integral) is a useful measure of the mechanical work performed by a segment of myo...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-197611000-00010

    authors: Ringertz HG,Carlsson E,Tyberg JV

    更新日期:1976-11-01 00:00:00

  • Computer-aided detection for computed tomographic colonography screening: a prospective comparison of a double-reading paradigm with first-reader computer-aided detection against second-reader computer-aided detection.

    abstract:OBJECTIVES:The objective of this study was to prospectively compare diagnostic performance and time efficiency of a double-reading paradigm in which a first-reader computer-aided detection (CAD) is followed by a fast 2-dimensional review (DR FR-CAD) with those of a double reading with second-reader CAD (SR CAD). MATER...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000009

    authors: Iussich G,Correale L,Senore C,Hassan C,Segnan N,Campanella D,Bert A,Galatola G,Laudi C,Regge D

    更新日期:2014-03-01 00:00:00

  • Structured Reporting of Rectal Magnetic Resonance Imaging in Suspected Primary Rectal Cancer: Potential Benefits for Surgical Planning and Interdisciplinary Communication.

    abstract:OBJECTIVES:The aim of this study was to evaluate the effect of structured reports (SRs) in comparison to nonstructured, free-text (FT) rectal magnetic resonance imaging (MRI) reports in patients with histologically proven rectal cancer and potential effects of both types of reporting on referring surgeons' satisfaction...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000336

    authors: Nörenberg D,Sommer WH,Thasler W,DʼHaese J,Rentsch M,Kolben T,Schreyer A,Rist C,Reiser M,Armbruster M

    更新日期:2017-04-01 00:00:00

  • Contrast media-induced chromosomal damage in human lymphocyte cultures.

    abstract::Ionic (diatrizoate, ioxaglate) and nonionic (iohexol, iosimide, iopromide, and iotrolan) contrast media (CM) were evaluated for their cytogenetic effects in lymphocytes. Heparinized blood was mixed with culture medium RPMI-1640 supplemented with phytohemagglutinin, fetal calf serum, and antibiotics. Plastic tubes cont...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198611000-00006

    authors: Parvez Z,Kormano M,Moncada R,Eklund R

    更新日期:1986-11-01 00:00:00

  • Comparison of left ventricular ejection fraction and regional contractility fraction pre and post coronary angiography.

    abstract::Thirty patients [four normals, eight with mild and 18 with severe coronary artery disease (CAD)] were studied to evaluate left ventricular function type and post coronary angiography. The end diastolic volume (EDV), end systolic volume (ESV), ejection fraction (EF) and the regional contractility fractions (RCF) of eig...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-197603000-00009

    authors: Sos TA,Baltaxe HA

    更新日期:1976-03-01 00:00:00

  • Spontaneous acute dissection of the internal carotid artery: high-resolution magnetic resonance imaging at 3.0 tesla with a dedicated surface coil.

    abstract:PURPOSE:Magnetic Resonance Imaging (MRI) has become the method of choice in the evaluation of patients with suspected cervical artery dissection (CAD). However, reliable identification of acute CAD might be impaired by the limited spatial resolution of standard 1.5 T MRI. In this preliminary study, we implemented a mul...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/01.rli.0000195836.57778.1f

    authors: Bachmann R,Nassenstein I,Kooijman H,Dittrich R,Kugel H,Niederstadt T,Kuhlenbäumer G,Ringelstein EB,Krämer S,Heindel W

    更新日期:2006-02-01 00:00:00

  • Magnetic resonance imaging-guided percutaneous biopsy of mediastinal masses: diagnostic performance and safety.

    abstract:OBJECTIVE:The objective of this study was to evaluate the diagnostic performance and safety of magnetic resonance (MR) imaging-guided percutaneous mediastinal biopsy procedures using a 0.23-T open MR system with optical tracking navigation. MATERIALS AND METHODS:A retrospective analysis of 59 participants (38 males an...

    journal_title:Investigative radiology

    pub_type: 临床试验,杂志文章

    doi:10.1097/RLI.0b013e31827a4a17

    authors: Lü Y,Fritz J,Li C,Liu M,Lee P,Wu L,Carrino JA

    更新日期:2013-06-01 00:00:00

  • Longitudinal Computed Tomography Monitoring of Pelvic Bones in Patients With Breast Cancer Using Automated Bone Subtraction Software.

    abstract:OBJECTIVE:The aim of this study was to optimize computed tomography (CT) surveillance of skeletal metastases in patients with breast cancer through the use of osseous subtraction maps between baseline and follow-up examinations created by a novel software algorithm. The new postprocessing algorithm segments the origina...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000343

    authors: Horger M,Thaiss WM,Wiesinger B,Ditt H,Fritz J,Nikolaou K,Kloth C

    更新日期:2017-02-01 00:00:00

  • Contrast-enhanced magnetic resonance angiography of the carotid arteries: influence of injection rates and volumes on arterial-venous transit time.

    abstract:RATIONALE AND OBJECTIVES:To assess the influence of injection rates and volumes on the arrival time of contrast material (CM) in the common carotid artery, the jugular vein and the resulting arterial-venous transit time. Additionally the relationship between injection parameters and the extent of a CM plateau was evalu...

    journal_title:Investigative radiology

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1097/01.rli.0000105040.40925.c8

    authors: Herold T,Paetzel C,Völk M,Bachthaler M,Zorger N,Feuerbach S,Strotzer M,Lenhart M

    更新日期:2004-02-01 00:00:00

  • Necrotic areas in VX2 carcinoma of rabbits. Correlation of magnetic resonance imaging and pathologic appearance.

    abstract:RATIONALE AND OBJECTIVES:To assess the potential of magnetic resonance imaging (MRI) for evaluating the evolution of tumor necrosis, the authors evaluated 28 VX2 carcinomas inoculated in the thigh muscles of rabbits. METHODS:MRI of VX2 carcinomas at 2.0 T was done with spin-echo technique 1 week (14 tumors) and 3 week...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199301000-00010

    authors: Choi BI,Lee DH,Han MC

    更新日期:1993-01-01 00:00:00

  • Low tube voltage improves computed tomography imaging of delayed myocardial contrast enhancement in an experimental acute myocardial infarction model.

    abstract:OBJECTIVE:We sought to evaluate the influence of tube voltage on the visualization of acute myocardial infarction (MI) in cardiac multislice spiral computed tomography (MSCT). MATERIALS AND METHODS:Acute MI was induced in 12 domestic pigs by a 45-minute balloon occlusion of the left anterior descending artery. Delayed...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/01.rli.0000251577.68223.84

    authors: Mahnken AH,Bruners P,Mühlenbruch G,Emmerich M,Hohl C,Günther RW,Wildberger JE

    更新日期:2007-02-01 00:00:00

  • Vascular alterations in canine histiocytic ulcerative colitis.

    abstract::The large intestines of eight boxer dogs with canine histiocytic ulcerative colitis (CHUC) and 10 normal dogs were studied by in vivo angiography and postmortem microangiography. The vascular abnormalities were correlated with the gross and histologic pathology found at necropsy. The angiographic abnormalities were ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-197505000-00005

    authors: Lawson TL,Gomez JA,Margulis AR

    更新日期:1975-05-01 00:00:00

  • Evolution of the ablation region after magnetic resonance-guided high-intensity focused ultrasound ablation in a Vx2 tumor model.

    abstract:OBJECTIVES:Volumetric magnetic resonance (MR)-guided high-intensity focused ultrasound (HIFU) is a completely noninvasive image-guided thermal ablation technique. Recently, there has been growing interest in the use of MR-HIFU for noninvasive ablation of malignant tumors. Of particular interest for noninvasive ablation...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e3182820257

    authors: Wijlemans JW,Deckers R,van den Bosch MA,Seinstra BA,van Stralen M,van Diest PJ,Moonen CT,Bartels LW

    更新日期:2013-06-01 00:00:00

  • Deep Learning on Conventional Magnetic Resonance Imaging Improves the Diagnosis of Multiple Sclerosis Mimics.

    abstract:OBJECTIVES:The aims of this study were to present a deep learning approach for the automated classification of multiple sclerosis and its mimics and compare model performance with that of 2 expert neuroradiologists. MATERIALS AND METHODS:A total of 268 T2-weighted and T1-weighted brain magnetic resonance imagin scans ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000735

    authors: Rocca MA,Anzalone N,Storelli L,Del Poggio A,Cacciaguerra L,Manfredi AA,Meani A,Filippi M

    更新日期:2020-10-26 00:00:00

  • The effect of some iodinated contrast media on human plasma butyrylcholinesterase activity.

    abstract::The effect of three iodinated contrast media (CM) on human plasma butyrylcholinesterase (BuChE) activity was studied during the intravenous pyelography (i.v.P). BuChE is an enzyme that participates in the metabolism of acetylcholine and hydrolyzes food esters and drugs such as nondepolarizing muscle relaxants and loca...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199805000-00008

    authors: Mironidou M,Ximitidou O,Christopoulos S,Kokkas B

    更新日期:1998-05-01 00:00:00

  • Searching for lung nodules. A comparison of human performance with random and systematic scanning models.

    abstract::The contrast sensitivity of the retina is greatest in the center and decreases rapidly toward the periphery. Therefore, the detection of low-contrast lung nodules depends upon the manner in which the image is sampled by retinal receptors as eye fixations jump across the image during scanning. The scanning performance ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198705000-00010

    authors: Kundel HL,Nodine CF,Thickman D,Toto L

    更新日期:1987-05-01 00:00:00

  • Systemic absorption of gallbladder sclerosing agents in the rabbit. A preliminary study.

    abstract::The absorbed levels of ethanol or tetracycline, used as gallbladder sclerosing agents, were measured in the systemic blood circulation of 16 rabbits. The maximal systemic level of ethanol was 46 mg/dl and of tetracycline was 4.6 micrograms/ml after 30 minutes of gallbladder exposure. Comparable serum levels would be c...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198605000-00005

    authors: Remley KB,Cubberley DA,Watanabe AS,Nelson JA,Colby TV

    更新日期:1986-05-01 00:00:00

  • Low-Dose Characterization of Kidney Stones Using Spectral Detector Computed Tomography: An Ex Vivo Study.

    abstract:OBJECTIVES:The aim of this study was to investigate the feasibility of kidney stone composition analysis using spectral detector computed tomography scanner (SDCT) with normal- and low-dose imaging protocols. METHODS:A total of 154 stones harvested from nephrolithotripsy or nephrolithotomy with a known monocrystalline...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000468

    authors: Große Hokamp N,Salem J,Hesse A,Holz JA,Ritter M,Heidenreich A,Maintz D,Haneder S

    更新日期:2018-08-01 00:00:00

  • Combined methods for assessment of neurotoxicity: testing of new nonionic radiographic media.

    abstract::A battery of tests for toxicity assessment of new contrast media is reviewed. Cell toxicity in a protozoan culture (Blepharisma americanum); lethal dose determination in mice; EEG Spectral analysis following cisternography in rabbits; ED50 and LD50 determination by intra- and pericerebral injection in rats; intraciste...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198011001-00053

    authors: Sovak M,Siefert HM,Ranganathan R

    更新日期:1980-11-01 00:00:00

  • Nonenhanced magnetic resonance angiography of the lower extremity vessels at 7 tesla: initial experience.

    abstract:OBJECTIVES:The aim of this study was to investigate the feasibility of nonenhanced magnetic resonance angiography (MRA) of the lower extremities at 7 tesla (T). MATERIALS AND METHODS:Eight healthy volunteers were examined on a 7-T whole-body magnetic resonance system. For image acquisition, a custom-built 16-channel t...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e3182839c2b

    authors: Fischer A,Maderwald S,Orzada S,Johst S,Schäfer LC,Ladd ME,Nassenstein K,Umutlu L,Lauenstein TC

    更新日期:2013-07-01 00:00:00

  • Prediction of antiangiogenic treatment efficacy by iron oxide enhanced parametric magnetic resonance imaging.

    abstract:RATIONALE AND OBJECTIVES:Tools for monitoring modern target-specific antiangiogenic and antivascular therapies are highly desirable because treatment strategies are time consuming, expensive, and yet sometimes ineffective. Therefore, the aim of this experimental study was to evaluate the predictive value of steady-stat...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e3180d5cbd9

    authors: Persigehl T,Matuszewski L,Kessler T,Wall A,Meier N,Ebert W,Berdel WE,Heindel W,Mesters R,Bremer C

    更新日期:2007-12-01 00:00:00

  • Diminished cerebrospinal fluid beta-endorphin concentration in monkeys with arachnoiditis.

    abstract::Altered concentrations of brain beta endorphin and spinal cord encephalin have been reported in mice with iatrogenic arachnoiditis. We measured beta-endorphin concentration in cerebrospinal fluid (CSF) in normal monkeys and in monkeys with various degrees of arachnoiditis resulting from myelography and spinal surgery ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198803000-00006

    authors: Lipman BT,Haughton VM

    更新日期:1988-03-01 00:00:00

  • Specific enhancement of intra-abdominal abscesses with perfluoroctylbromide for CT imaging.

    abstract::Perfluoroctylbromide (PFOB), a radiopaque reticuloendothelial system contrast media for computed tomography, has been shown to accumulate in macrophages. In the current study PFOB was tested in rabbits as an abscess imaging agent. Two abscesses were induced in each of 24 rabbits, one in the liver and the other in the ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198409000-00017

    authors: Mattrey RF,Andrè M,Campbell J,Mitten R,Multer F,Hackney D,Long DM,Higgins CB

    更新日期:1984-09-01 00:00:00

  • Phlebography. Survey and present state.

    abstract::Milestones in the history of phlebography are shortly reviewed. The present state of phlebography with emphasis upon the role of new nonionic contrast media is presented. ...

    journal_title:Investigative radiology

    pub_type: 临床试验,杂志文章

    doi:

    authors: Enge I

    更新日期:1985-01-01 00:00:00