A method for the study of regional ischemic dysfunction in the intact dog. Permanent endocardial markers and the pressure-length loop.

Abstract:

:A radiographic method for use in the closed-chest dog is described which allows the quantitation of segmental mechanical performance. Previous work has shown that the area of the pressure-length loop (an approximation of a stress-strain integral) is a useful measure of the mechanical work performed by a segment of myocardium. The position of radiopaque markers previously placed to define segments of myocardium is recorded by biplane cineradiography. From simultaneous measurements of left ventricular pressure the integral of pressure with respect to segment length during one cardiac cycle is calculated. An example illustrating the utility of this model for the study of regional myocardial ischemia is presented.

journal_name

Invest Radiol

journal_title

Investigative radiology

authors

Ringertz HG,Carlsson E,Tyberg JV

doi

10.1097/00004424-197611000-00010

keywords:

subject

Has Abstract

pub_date

1976-11-01 00:00:00

pages

556-62

issue

6

eissn

0020-9996

issn

1536-0210

journal_volume

11

pub_type

杂志文章
  • Magnetic resonance angiography in infrapopliteal arterial disease: prospective comparison of 1.5 and 3 Tesla magnetic resonance imaging.

    abstract:PURPOSE:To prospectively determine the accuracy of 1.5 Tesla (T) and 3 T magnetic resonance angiography (MRA) versus digital subtraction angiography (DSA) in the depiction of infrageniculate arteries in patients with symptomatic peripheral arterial disease. PATIENTS AND METHODS:A prospective 1.5 T, 3 T MRA, and DSA co...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/01.rli.0000262581.52315.ef

    authors: Diehm N,Kickuth R,Baumgartner I,Srivastav SK,Gretener S,Husmann MJ,Jaccard Y,Do do D,Triller J,Bonel HM

    更新日期:2007-06-01 00:00:00

  • Incompatibility of water-soluble contrast media and intravascular pharmacologic agents. An in vitro study.

    abstract::In vitro incompatibilities between nine water-soluble contrast media and 21 intravascular pharmacologic agents were investigated using naked-eye observation and a centrifuge. Most of the previously reported incompatibilities were verified, and a few new incompatibilities were discovered: phentolamine mesylate with dia...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199201000-00008

    authors: Kim SH,Lee HK,Han MC

    更新日期:1992-01-01 00:00:00

  • Comparative evaluation of digital radiography versus conventional radiography of fractured skulls.

    abstract:OBJECTIVES:The authors assessed the relative efficacy of conventional and digital storage-phosphor radiographs for the detection of skull fractures. METHODS:Fifty conventional film-screen radiographs (FSR) and 50 digital storage-phosphor radiographs (DR) with 66 fractures were compared. Five radiologists evaluated ima...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199308000-00005

    authors: Langen HJ,Klein HM,Wein B,Stargardt A,Günther RW

    更新日期:1993-08-01 00:00:00

  • Patient choice and nonionic contrast media.

    abstract:RATIONALE AND OBJECTIVES:Because of the greatly increased cost of nonionic, low-osmolar contrast material, some practitioners reserve its use for patients at high risk for an adverse contrast reaction. The authors attempt to evaluate the proportion of low-risk outpatients--when offered a choice between the more expensi...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199304000-00008

    authors: Hopper KD,Matthews YL

    更新日期:1993-04-01 00:00:00

  • Radiolabeled leukocytes and platelets.

    abstract::Radiolabeled blood cells are widely used for both clinical and research studies. In vitro and in vivo studies have shown the tagging process does not significantly affect function. The labeling techniques and clinical uses of labeled leukocytes and platelets are reviewed. ...

    journal_title:Investigative radiology

    pub_type: 杂志文章,评审

    doi:10.1097/00004424-198603000-00001

    authors: Datz FL

    更新日期:1986-03-01 00:00:00

  • Visualization of breast lymphatic pathways with an indirect computed tomography lymphography using a nonionic monometric contrast medium iopamidol: preliminary results.

    abstract:RATIONALE AND OBJECTIVES:The capability of an indirect computed tomographic lymphography (CT-LG) using a nonionic monometric contrast medium iopamidol for visualizing breast lymphatic pathways was preliminarily tested. MATERIALS AND METHODS:In 10 female dogs, a total of 0.5 and 1 mL of undiluted iopamidol was injected...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-200302000-00002

    authors: Suga K,Ogasawara N,Yuan Y,Okada M,Matsunaga N,Tangoku A

    更新日期:2003-02-01 00:00:00

  • The effect of certain variables on the tumor and tissue distribution of tracers: VI. False-carrier effect, Part III, Fe.

    abstract::Previous work has shown that Fe3+, when administered in the proper dose and time sequence, increases the tumor uptake of gallium-67 (67Ga) while decreasing its uptake by normal tissues. The purpose of this series of experiments was to examine further the postulate that the false carrier effect is mediated at the cellu...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198207000-00016

    authors: Stern PH,Halpern SE,Hagan PL,Chen A

    更新日期:1982-07-01 00:00:00

  • Detection of breast abnormalities on teleradiology transmitted mammograms.

    abstract::The authors conducted an observer performance study to compare breast lesion detection of conventional mammography (CM) with teleradiology (TE) transmitted mammograms. One hundred four abnormal, single-projection mammographic images were transmitted by teleradiology. Abnormalities included 11 cases with skin thickenin...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199010000-00007

    authors: Fajardo LL,Yoshino MT,Seeley GW,Hunt R,Hunter TB,Friedman R,Cardenas D,Boyle R

    更新日期:1990-10-01 00:00:00

  • Clinical comparison between a currently available single-loop and an investigational dual-channel endorectal receive coil for prostate magnetic resonance imaging: a feasibility study at 1.5 and 3 T.

    abstract:OBJECTIVES:The objectives of this study were to test the feasibility of an investigational dual-channel next-generation endorectal coil (NG-ERC) in vivo, to quantitatively assess signal-to-noise ratio (SNR), and to get an impression of image quality compared with the current clinically available single-loop endorectal ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e3182a56678

    authors: Vos EK,Sambandamurthy S,Kamel M,McKenney R,van Uden MJ,Hoeks CM,Yakar D,Scheenen TW,Fütterer JJ

    更新日期:2014-01-01 00:00:00

  • Measurement of distensibility of blood vessels using cineangiograms.

    abstract::We developed a new, cineangiographic method to accurately measure the dynamic changes in the internal diameter of human arteries in vivo. Cine films were digitized at a spatial resolution of 4 microns/pixel, using a line image sensor. The vessel edges, with a Gaussian fit to a unilateral profile curve of the vessel, w...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198909000-00005

    authors: Sugahara T,Yanagihara Y,Uyama C,Maeda H,Takafuchi M,Azumi T

    更新日期:1989-09-01 00:00:00

  • Pathophysiology of radiocontrast nephropathy: a role for medullary hypoxia.

    abstract::Recent experimental data underlies the role of hypoxic tubular injury in the pathophysiology of radiocontrast nephropathy. Although systemic transient hypoxemia, increased blood viscosity, and a leftward shift of the oxygen-hemoglobin dissociation curve may all contribute to intrarenal hypoxia, imbalance between oxyge...

    journal_title:Investigative radiology

    pub_type: 杂志文章,评审

    doi:10.1097/00004424-199911000-00004

    authors: Heyman SN,Reichman J,Brezis M

    更新日期:1999-11-01 00:00:00

  • Detection and characterization of crystal suspensions using single-source dual-energy computed tomography: a phantom model of crystal arthropathies.

    abstract:OBJECTIVES:The aim of this study was to perform phantom measurements to prove the feasibility of single-source dual-energy computed tomography (DECT) of the extremities using a volume scan mode. In addition, we, for the first time, wanted to determine which concentrations of monosodium urate (MSU) in gout and calcium p...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000099

    authors: Diekhoff T,Kiefer T,Stroux A,Pilhofer I,Juran R,Mews J,Blobel J,Tsuyuki M,Ackermann B,Hamm B,Hermann KG

    更新日期:2015-04-01 00:00:00

  • Spatial resolution analysis of computed tomographic images.

    abstract::Methods are presented for the quantification of spatial resolution in x-ray computed tomographic (CT) images. Model-dependent methods are derived and compared with model independent methods for computation of the Modulation Transfer Function (MTF). These techniques are applied to phantom images of point, line, edge, a...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198603000-00012

    authors: Assimakopoulos PA,Boyd DP,Jaschke W,Lipton MJ

    更新日期:1986-03-01 00:00:00

  • The importance of end-systole for optimal reconstruction protocol of coronary angiography with 16-slice multidetector computed tomography.

    abstract:OBJECTIVES:Multidetector-row computed tomography coronary images are usually analyzed in mid-diastole (MD). Because of slow coronary motion also in end-systole (ES), we evaluated the impact on image quality of including ES images and defined an efficient reconstruction protocol. MATERIAL AND METHODS:In 50 coronary mul...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/01.rli.0000153930.34439.e4

    authors: Sanz J,Rius T,Kuschnir P,Fuster V,Goldberg J,Ye XY,Wisdom P,Poon M

    更新日期:2005-03-01 00:00:00

  • Contrast-enhanced magnetic resonance angiography in rabbits: evaluation of the gadolinium-based agent p846 and the iron-based blood pool agent p904 in comparison with gadoterate meglumine.

    abstract:OBJECTIVES:: To evaluate the performance of a gadolinium-based contrast compound (P846) as well as an ultra-small particle of iron oxide agent (P904) in contrast-enhanced magnetic resonance angiography (MRA) in rabbits and to compare those agents with gadoterate meglumine (Gd-DOTA) for first pass and steady state imagi...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e31821ae21f

    authors: Kinner S,Maderwald S,Parohl N,Albert J,Corot C,Robert P,Barkhausen J,Vogt FM

    更新日期:2011-08-01 00:00:00

  • Pyelovenous and pyelolymphatic backflow during retrograde pyelography in renal vein thrombosis.

    abstract::Pyelovenous and pyelolymphatic backflow have been observed during retrograde pyelography in three patients with renal vein thrombosis. The radiographic patterns of backflow following experimental unilateral renal vein occlusion in rabbits were analyzed and correlated with the clinical findings. Capsular, perihilar, pe...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198101000-00003

    authors: Bidgood WD Jr,Cuttino JT Jr,Clark RL,Volberg FM

    更新日期:1981-01-01 00:00:00

  • Digital radiography versus conventional radiography for the detection of a skull fracture under varying exposure parameters.

    abstract:RATIONALE AND OBJECTIVES:The effect of varying exposure parameters on the detectability of a fracture with digital and conventional radiography were examined. METHODS:A macerated fractured skull was imaged by film-screen radiography (FSR) and digital storage phosphor radiography (DR) with various exposure values. Five...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199303000-00010

    authors: Langen HJ,Klein HM,Wein B,Schiwy-Bochat KH,Stargardt A,Günther RW

    更新日期:1993-03-01 00:00:00

  • Mechanical and biochemical cardiac disturbances induced by bolus administration of iodinated contrast media and noniodinated solutions.

    abstract:RATIONALE AND OBJECTIVES:Bolus injection of iodinated contrast media has been observed to alter myocardial mechanical function, but the consequences on cellular metabolism are poorly documented. Modifications of metabolic parameters (intracellular pH as well as adenosine triphosphate [ATP], phosphocreatine, and inorgan...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199501000-00001

    authors: Goossens A,Vander Elst L,Van Haverbeke Y,Muller RN

    更新日期:1995-01-01 00:00:00

  • Measured Multipoint Ultra-High b-Value Diffusion MRI in the Assessment of MRI-Detected Prostate Lesions.

    abstract:OBJECTIVES:The aim of this study was to assess quantitative ultra-high b-value (UHB) diffusion magnetic resonance imaging (MRI)-derived parameters in comparison to standard clinical apparent diffusion coefficient (SD-ADC-2b-1000, SD-ADC-2b-1500) for the prediction of clinically significant prostate cancer, defined as G...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000712

    authors: Tavakoli AA,Kuder TA,Tichy D,Radtke JP,Görtz M,Schütz V,Stenzinger A,Hohenfellner M,Schlemmer HP,Bonekamp D

    更新日期:2021-02-01 00:00:00

  • Magnetic resonance imaging contrast enhancement of brain tumors at 3 tesla versus 1.5 tesla.

    abstract:RATIONALE AND OBJECTIVES:To compare the diagnostic efficacy of a standard dose of MRI contrast agent in the evaluation of primary brain tumors and metastases using a high-field 3 tesla MR unit versus a 1.5 tesla MR unit. METHODS:Sixteen patients with brain tumors were examined at both field strengths using identical a...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-200203000-00003

    authors: Nöbauer-Huhmann IM,Ba-Ssalamah A,Mlynarik V,Barth M,Schöggl A,Heimberger K,Matula C,Fog A,Kaider A,Trattnig S

    更新日期:2002-03-01 00:00:00

  • Experimental arterial stent placement. Comparison of a new Nitinol stent and Wallstent.

    abstract:RATIONALE AND OBJECTIVES:To compare technical aspects and neointima formation of a new Nitinol stent and a Wallstent. METHODS:A Nitinol sten and a Wallstent were placed into the iliac arteries of 14 sheep (total of 28 stents) and followed angiographically. Seven sheep were killed after 1 month and 7 after 4.5 months. ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199507000-00004

    authors: Schürmann K,Vorwerk D,Kulisch A,Stroehmer-Kulisch E,Biesterfeld S,Stopinski T,Günther RW

    更新日期:1995-07-01 00:00:00

  • CTA contrast enhancement of the aorta and pulmonary artery: the effect of saline chase injected at two different rates in a canine experimental model.

    abstract:OBJECTIVE:To investigate the effect of saline chase injected at 2 different rates on computed tomography (CT) angiography. MATERIALS AND METHODS:This study was approved by our institutional animal study committee. Three injection protocols were used; contrast injection (24 mL, 0.8 mL/s) without saline chase (protocol ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e318032a9fe

    authors: Lee CH,Goo JM,Bae KT,Lee HJ,Kim KG,Chun EJ,Park CM,Im JG

    更新日期:2007-07-01 00:00:00

  • Optimizing an ultrasound contrast agent's stability using in vitro attenuation measurements.

    abstract:RATIONALE AND OBJECTIVES:To evaluate the changes in the microbubble population of a currently available ultrasound contrast agent (USCA) through attenuation measurements to optimize its clinical use. MATERIALS AND METHODS:The microbubble population from a galactose-based USCA (Levovist, Schering AG, Germany) was chara...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-200212000-00006

    authors: Correas JM,Kurtisovski E,Bridal SL,Amararene A,Hélénon O,Berger G

    更新日期:2002-12-01 00:00:00

  • Black-blood diffusion-weighted EPI acquisition of the liver with parallel imaging: comparison with a standard T2-weighted sequence for detection of focal liver lesions.

    abstract:OBJECTIVES:To evaluate the performance of black-blood diffusion-weighted (DW)-EPI sequences with parallel imaging for the detection of focal liver lesions in comparison with a standard T2-weighted (T2-w) sequence. MATERIALS AND METHODS:Twenty patients with known or suspected focal liver lesions underwent liver MRI usi...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e31816200b5

    authors: Zech CJ,Herrmann KA,Dietrich O,Horger W,Reiser MF,Schoenberg SO

    更新日期:2008-04-01 00:00:00

  • Ventral sacroiliac ligament. Anatomic and pathologic considerations.

    abstract:RATIONALE AND OBJECTIVES:The ventral sacroiliac ligament (VSL), which bridges the sacroiliac (SI) joint anteriorly, has been described as an important stabilizing structure of the joint, but no data exist regarding its assessment with routine and advanced imaging methods. The authors determine the imaging appearance of...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199608000-00009

    authors: Jaovisidha S,Ryu KN,De Maeseneer M,Haghighi P,Goodwin D,Sartoris DJ,Resnick D

    更新日期:1996-08-01 00:00:00

  • Fluorinated blood substitute retention in the rat measured by fluorine-19 magnetic resonance imaging.

    abstract:RATIONALE AND OBJECTIVES:Emulsions of perfluorocarbons (PFCs) have been tested as blood substitutes. However, evidence exists that there is long-term retention of some PFCs by the organs of the reticuloendothelial system (RES). The authors investigate organ retention of the blood substitute component, perfluorotripropy...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199208000-00012

    authors: Meyer KL,Carvlin MJ,Mukherji B,Sloviter HA,Joseph PM

    更新日期:1992-08-01 00:00:00

  • A review of the toxicity of nonionic contrast agents in children.

    abstract:OBJECTIVES:The safety of nonionic contrast agents with that of ionic iodinated contrast agents in children is compared. METHODS:A comprehensive literature search was conducted to identify all publications on the safety profile of nonionic contrast agents administered intravenously to children. This information was com...

    journal_title:Investigative radiology

    pub_type: 杂志文章,评审

    doi:10.1097/00004424-199311001-00027

    authors: Cohen MD

    更新日期:1993-11-01 00:00:00

  • The effect of computed tomographic scan orientation on information loss in the three-dimensional reconstruction of tripod zygomatic fractures.

    abstract::Fractures modeled in the dried skull indicate that the initial plane of computed tomography (CT) section contributes to the accuracy of three-dimensional (3D) images generated from two-dimensional (2D) CT data. The authors retrospectively analyzed seven clinical cases of tripod zygomatic fractures that were imaged wit...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199105000-00009

    authors: Levy RA,Kellman RM,Rosenbaum AE

    更新日期:1991-05-01 00:00:00

  • An overview of neck node sonography.

    abstract:RATIONALE AND OBJECTIVES:Gray scale and power Doppler sonography are commonly used to evaluate cervical lymph nodes. This study was undertaken to identify which of the features used in ultrasound of cervical lymph nodes is readily applicable in routine clinical practice. METHODS:Two hundred and eight-six patients diag...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-200206000-00005

    authors: Ahuja A,Ying M

    更新日期:2002-06-01 00:00:00

  • Contrast media for CT. An analysis of the early pharmacokinetics.

    abstract::Iohexol and meglumine-sodium diatrizoate were injected intravenously into 18 pigs as either a 99:1 or 1:99 mixture. Blood samples were taken for 30 minutes and the concentration of each of the two contrast media was measured by means of a double labeling technique with 125I and 131I. Relative concentrations of iohexol...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198511000-00016

    authors: Jensen LI,Dean PB,Nyman U,Golman K

    更新日期:1985-11-01 00:00:00