Abstract:
:A radiographic method for use in the closed-chest dog is described which allows the quantitation of segmental mechanical performance. Previous work has shown that the area of the pressure-length loop (an approximation of a stress-strain integral) is a useful measure of the mechanical work performed by a segment of myocardium. The position of radiopaque markers previously placed to define segments of myocardium is recorded by biplane cineradiography. From simultaneous measurements of left ventricular pressure the integral of pressure with respect to segment length during one cardiac cycle is calculated. An example illustrating the utility of this model for the study of regional myocardial ischemia is presented.
journal_name
Invest Radioljournal_title
Investigative radiologyauthors
Ringertz HG,Carlsson E,Tyberg JVdoi
10.1097/00004424-197611000-00010keywords:
subject
Has Abstractpub_date
1976-11-01 00:00:00pages
556-62issue
6eissn
0020-9996issn
1536-0210journal_volume
11pub_type
杂志文章abstract:PURPOSE:To prospectively determine the accuracy of 1.5 Tesla (T) and 3 T magnetic resonance angiography (MRA) versus digital subtraction angiography (DSA) in the depiction of infrageniculate arteries in patients with symptomatic peripheral arterial disease. PATIENTS AND METHODS:A prospective 1.5 T, 3 T MRA, and DSA co...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/01.rli.0000262581.52315.ef
更新日期:2007-06-01 00:00:00
abstract::In vitro incompatibilities between nine water-soluble contrast media and 21 intravascular pharmacologic agents were investigated using naked-eye observation and a centrifuge. Most of the previously reported incompatibilities were verified, and a few new incompatibilities were discovered: phentolamine mesylate with dia...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199201000-00008
更新日期:1992-01-01 00:00:00
abstract:OBJECTIVES:The authors assessed the relative efficacy of conventional and digital storage-phosphor radiographs for the detection of skull fractures. METHODS:Fifty conventional film-screen radiographs (FSR) and 50 digital storage-phosphor radiographs (DR) with 66 fractures were compared. Five radiologists evaluated ima...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199308000-00005
更新日期:1993-08-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:Because of the greatly increased cost of nonionic, low-osmolar contrast material, some practitioners reserve its use for patients at high risk for an adverse contrast reaction. The authors attempt to evaluate the proportion of low-risk outpatients--when offered a choice between the more expensi...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199304000-00008
更新日期:1993-04-01 00:00:00
abstract::Radiolabeled blood cells are widely used for both clinical and research studies. In vitro and in vivo studies have shown the tagging process does not significantly affect function. The labeling techniques and clinical uses of labeled leukocytes and platelets are reviewed. ...
journal_title:Investigative radiology
pub_type: 杂志文章,评审
doi:10.1097/00004424-198603000-00001
更新日期:1986-03-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:The capability of an indirect computed tomographic lymphography (CT-LG) using a nonionic monometric contrast medium iopamidol for visualizing breast lymphatic pathways was preliminarily tested. MATERIALS AND METHODS:In 10 female dogs, a total of 0.5 and 1 mL of undiluted iopamidol was injected...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-200302000-00002
更新日期:2003-02-01 00:00:00
abstract::Previous work has shown that Fe3+, when administered in the proper dose and time sequence, increases the tumor uptake of gallium-67 (67Ga) while decreasing its uptake by normal tissues. The purpose of this series of experiments was to examine further the postulate that the false carrier effect is mediated at the cellu...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198207000-00016
更新日期:1982-07-01 00:00:00
abstract::The authors conducted an observer performance study to compare breast lesion detection of conventional mammography (CM) with teleradiology (TE) transmitted mammograms. One hundred four abnormal, single-projection mammographic images were transmitted by teleradiology. Abnormalities included 11 cases with skin thickenin...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199010000-00007
更新日期:1990-10-01 00:00:00
abstract:OBJECTIVES:The objectives of this study were to test the feasibility of an investigational dual-channel next-generation endorectal coil (NG-ERC) in vivo, to quantitatively assess signal-to-noise ratio (SNR), and to get an impression of image quality compared with the current clinically available single-loop endorectal ...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0b013e3182a56678
更新日期:2014-01-01 00:00:00
abstract::We developed a new, cineangiographic method to accurately measure the dynamic changes in the internal diameter of human arteries in vivo. Cine films were digitized at a spatial resolution of 4 microns/pixel, using a line image sensor. The vessel edges, with a Gaussian fit to a unilateral profile curve of the vessel, w...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198909000-00005
更新日期:1989-09-01 00:00:00
abstract::Recent experimental data underlies the role of hypoxic tubular injury in the pathophysiology of radiocontrast nephropathy. Although systemic transient hypoxemia, increased blood viscosity, and a leftward shift of the oxygen-hemoglobin dissociation curve may all contribute to intrarenal hypoxia, imbalance between oxyge...
journal_title:Investigative radiology
pub_type: 杂志文章,评审
doi:10.1097/00004424-199911000-00004
更新日期:1999-11-01 00:00:00
abstract:OBJECTIVES:The aim of this study was to perform phantom measurements to prove the feasibility of single-source dual-energy computed tomography (DECT) of the extremities using a volume scan mode. In addition, we, for the first time, wanted to determine which concentrations of monosodium urate (MSU) in gout and calcium p...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0000000000000099
更新日期:2015-04-01 00:00:00
abstract::Methods are presented for the quantification of spatial resolution in x-ray computed tomographic (CT) images. Model-dependent methods are derived and compared with model independent methods for computation of the Modulation Transfer Function (MTF). These techniques are applied to phantom images of point, line, edge, a...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198603000-00012
更新日期:1986-03-01 00:00:00
abstract:OBJECTIVES:Multidetector-row computed tomography coronary images are usually analyzed in mid-diastole (MD). Because of slow coronary motion also in end-systole (ES), we evaluated the impact on image quality of including ES images and defined an efficient reconstruction protocol. MATERIAL AND METHODS:In 50 coronary mul...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/01.rli.0000153930.34439.e4
更新日期:2005-03-01 00:00:00
abstract:OBJECTIVES:: To evaluate the performance of a gadolinium-based contrast compound (P846) as well as an ultra-small particle of iron oxide agent (P904) in contrast-enhanced magnetic resonance angiography (MRA) in rabbits and to compare those agents with gadoterate meglumine (Gd-DOTA) for first pass and steady state imagi...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0b013e31821ae21f
更新日期:2011-08-01 00:00:00
abstract::Pyelovenous and pyelolymphatic backflow have been observed during retrograde pyelography in three patients with renal vein thrombosis. The radiographic patterns of backflow following experimental unilateral renal vein occlusion in rabbits were analyzed and correlated with the clinical findings. Capsular, perihilar, pe...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198101000-00003
更新日期:1981-01-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:The effect of varying exposure parameters on the detectability of a fracture with digital and conventional radiography were examined. METHODS:A macerated fractured skull was imaged by film-screen radiography (FSR) and digital storage phosphor radiography (DR) with various exposure values. Five...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199303000-00010
更新日期:1993-03-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:Bolus injection of iodinated contrast media has been observed to alter myocardial mechanical function, but the consequences on cellular metabolism are poorly documented. Modifications of metabolic parameters (intracellular pH as well as adenosine triphosphate [ATP], phosphocreatine, and inorgan...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199501000-00001
更新日期:1995-01-01 00:00:00
abstract:OBJECTIVES:The aim of this study was to assess quantitative ultra-high b-value (UHB) diffusion magnetic resonance imaging (MRI)-derived parameters in comparison to standard clinical apparent diffusion coefficient (SD-ADC-2b-1000, SD-ADC-2b-1500) for the prediction of clinically significant prostate cancer, defined as G...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0000000000000712
更新日期:2021-02-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:To compare the diagnostic efficacy of a standard dose of MRI contrast agent in the evaluation of primary brain tumors and metastases using a high-field 3 tesla MR unit versus a 1.5 tesla MR unit. METHODS:Sixteen patients with brain tumors were examined at both field strengths using identical a...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-200203000-00003
更新日期:2002-03-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:To compare technical aspects and neointima formation of a new Nitinol stent and a Wallstent. METHODS:A Nitinol sten and a Wallstent were placed into the iliac arteries of 14 sheep (total of 28 stents) and followed angiographically. Seven sheep were killed after 1 month and 7 after 4.5 months. ...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199507000-00004
更新日期:1995-07-01 00:00:00
abstract:OBJECTIVE:To investigate the effect of saline chase injected at 2 different rates on computed tomography (CT) angiography. MATERIALS AND METHODS:This study was approved by our institutional animal study committee. Three injection protocols were used; contrast injection (24 mL, 0.8 mL/s) without saline chase (protocol ...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0b013e318032a9fe
更新日期:2007-07-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:To evaluate the changes in the microbubble population of a currently available ultrasound contrast agent (USCA) through attenuation measurements to optimize its clinical use. MATERIALS AND METHODS:The microbubble population from a galactose-based USCA (Levovist, Schering AG, Germany) was chara...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-200212000-00006
更新日期:2002-12-01 00:00:00
abstract:OBJECTIVES:To evaluate the performance of black-blood diffusion-weighted (DW)-EPI sequences with parallel imaging for the detection of focal liver lesions in comparison with a standard T2-weighted (T2-w) sequence. MATERIALS AND METHODS:Twenty patients with known or suspected focal liver lesions underwent liver MRI usi...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0b013e31816200b5
更新日期:2008-04-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:The ventral sacroiliac ligament (VSL), which bridges the sacroiliac (SI) joint anteriorly, has been described as an important stabilizing structure of the joint, but no data exist regarding its assessment with routine and advanced imaging methods. The authors determine the imaging appearance of...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199608000-00009
更新日期:1996-08-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:Emulsions of perfluorocarbons (PFCs) have been tested as blood substitutes. However, evidence exists that there is long-term retention of some PFCs by the organs of the reticuloendothelial system (RES). The authors investigate organ retention of the blood substitute component, perfluorotripropy...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199208000-00012
更新日期:1992-08-01 00:00:00
abstract:OBJECTIVES:The safety of nonionic contrast agents with that of ionic iodinated contrast agents in children is compared. METHODS:A comprehensive literature search was conducted to identify all publications on the safety profile of nonionic contrast agents administered intravenously to children. This information was com...
journal_title:Investigative radiology
pub_type: 杂志文章,评审
doi:10.1097/00004424-199311001-00027
更新日期:1993-11-01 00:00:00
abstract::Fractures modeled in the dried skull indicate that the initial plane of computed tomography (CT) section contributes to the accuracy of three-dimensional (3D) images generated from two-dimensional (2D) CT data. The authors retrospectively analyzed seven clinical cases of tripod zygomatic fractures that were imaged wit...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199105000-00009
更新日期:1991-05-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:Gray scale and power Doppler sonography are commonly used to evaluate cervical lymph nodes. This study was undertaken to identify which of the features used in ultrasound of cervical lymph nodes is readily applicable in routine clinical practice. METHODS:Two hundred and eight-six patients diag...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-200206000-00005
更新日期:2002-06-01 00:00:00
abstract::Iohexol and meglumine-sodium diatrizoate were injected intravenously into 18 pigs as either a 99:1 or 1:99 mixture. Blood samples were taken for 30 minutes and the concentration of each of the two contrast media was measured by means of a double labeling technique with 125I and 131I. Relative concentrations of iohexol...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198511000-00016
更新日期:1985-11-01 00:00:00