The effect of certain variables on the tumor and tissue distribution of tracers: VI. False-carrier effect, Part III, Fe.

Abstract:

:Previous work has shown that Fe3+, when administered in the proper dose and time sequence, increases the tumor uptake of gallium-67 (67Ga) while decreasing its uptake by normal tissues. The purpose of this series of experiments was to examine further the postulate that the false carrier effect is mediated at the cellular as well as the vascular level, determine the lowest concentration of ionic Fe3+ that will induce near maximum tumor/background ratios (T/Bkg), determine the best technique for its administration, and decide whether Benadryl and dexamethasone could be used to offset side effects of the Fe3+ without altering tumor and tissue kinetics. Fe3+ altered tissue levels of 67Ga prior to changes in the blood. The threshold for initiation of the false-carrier effect varied to some extent from one organ to another. Tumor uptake of 67Ga was either enhanced or unaltered at 4 hours after injection; 0.3 mg Fe3+/kg administered 0.5 hour before and 2 hours after the 67Ga enhanced 4-hour T/Bkg by a factor of about ten. Twenty-four-hour ratios were improved (to a lesser extent than 4-hour), but decreased concentrations of 67Ga occurred in the tumor. Dexamethasone and Benadryl did not alter the outcome of the experiment. This technique should be useful for imaging with gallium-68 and the PET camera.

journal_name

Invest Radiol

journal_title

Investigative radiology

authors

Stern PH,Halpern SE,Hagan PL,Chen A

doi

10.1097/00004424-198207000-00016

subject

Has Abstract

pub_date

1982-07-01 00:00:00

pages

386-93

issue

4

eissn

0020-9996

issn

1536-0210

journal_volume

17

pub_type

杂志文章
  • Extravascular extravasation of radiographic contrast media. Effects of conventional and low-osmolar agents in the rat thigh.

    abstract::We compared the damage resulting from intradermal injection of four commonly used radiographic contrast media in laboratory rats. Sixty percent meglumine diatrizoate (Reno M 60) and ioxaglate (Hexabrix) produced significantly more ulceration and crusting on gross inspection and more necrosis, edema, and hemorrhage on ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199005000-00006

    authors: Cohan RH,Leder RA,Bolick D,Herzberg AJ,Hedlund LW,Wheeler CT,Helms MJ,Dunnick NR

    更新日期:1990-05-01 00:00:00

  • Role of red blood cell deformation in toxicity of contrast media in cerebral angiography.

    abstract::The authors investigated the effect on the brain of red blood cells that had been modified by contrast media. Rat blood was mixed with an equivolume of contrast media, and up to 200 microL of the mixture was infused to the internal carotid artery of the rat. Evans blue was administered intravenously to assess the inte...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198905000-00009

    authors: Miyazawa T,Nakagawa H,Oshino N

    更新日期:1989-05-01 00:00:00

  • Subtype differentiation of renal tumors using voxel-based histogram analysis of intravoxel incoherent motion parameters.

    abstract:OBJECTIVES:The aim of this study was to determine if voxel-based histogram analysis of intravoxel incoherent motion imaging (IVIM) parameters can differentiate various subtypes of renal tumors, including benign and malignant lesions. SUBJECTS AND METHODS:A total of 44 patients with renal tumors who underwent surgery a...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000111

    authors: Gaing B,Sigmund EE,Huang WC,Babb JS,Parikh NS,Stoffel D,Chandarana H

    更新日期:2015-03-01 00:00:00

  • Systemic absorption of gallbladder sclerosing agents in the rabbit. A preliminary study.

    abstract::The absorbed levels of ethanol or tetracycline, used as gallbladder sclerosing agents, were measured in the systemic blood circulation of 16 rabbits. The maximal systemic level of ethanol was 46 mg/dl and of tetracycline was 4.6 micrograms/ml after 30 minutes of gallbladder exposure. Comparable serum levels would be c...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198605000-00005

    authors: Remley KB,Cubberley DA,Watanabe AS,Nelson JA,Colby TV

    更新日期:1986-05-01 00:00:00

  • Evaluation of the prostate imaging reporting and data system for the detection of prostate cancer by the results of targeted biopsy of the prostate.

    abstract:PURPOSE:The purpose of this study was to evaluate the magnetic resonance prostate imaging reporting and data system (PI-RADS) for the detection of prostate cancer by the results of magnetic resonance imaging (MRI)-guided biopsy of the prostate as a reference standard. PATIENTS AND METHODS:In 55 patients who had underg...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000030

    authors: Baur AD,Maxeiner A,Franiel T,Kilic E,Huppertz A,Schwenke C,Hamm B,Durmus T

    更新日期:2014-06-01 00:00:00

  • Detection and characterization of focal liver lesions: a Japanese phase III, multicenter comparison between gadoxetic acid disodium-enhanced magnetic resonance imaging and contrast-enhanced computed tomography predominantly in patients with hepatocellular

    abstract:OBJECTIVES:To prospectively evaluate the safety and efficacy of combined unenhanced and gadoxetic acid disodium (Gd-EOB-DTPA)-enhanced magnetic resonance (MR) imaging compared with unenhanced MR imaging and triphasic contrast-enhanced spiral computed tomography (CT) for the detection and characterization of focal liver...

    journal_title:Investigative radiology

    pub_type: 杂志文章,多中心研究

    doi:10.1097/RLI.0b013e3181caea5b

    authors: Ichikawa T,Saito K,Yoshioka N,Tanimoto A,Gokan T,Takehara Y,Kamura T,Gabata T,Murakami T,Ito K,Hirohashi S,Nishie A,Saito Y,Onaya H,Kuwatsuru R,Morimoto A,Ueda K,Kurauchi M,Breuer J

    更新日期:2010-03-01 00:00:00

  • The use of continuous and discrete confidence judgments in receiver operating characteristic studies of diagnostic imaging techniques.

    abstract::Virtually all receiver operating characteristic (ROC) studies of medical imaging methods have involved data collected on a discrete confidence-rating scale, though in principle ROC studies can be conducted with either discrete or continuous scales. Continuous scales provide potential advantages in medical applications...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199202000-00016

    authors: Rockette HE,Gur D,Metz CE

    更新日期:1992-02-01 00:00:00

  • In-vitro assessment of the behavior of magnetic resonance angiography in the presence of constrictions.

    abstract:RATIONALE AND OBJECTIVES:Time-of-flight magnetic resonance angiography (TOF/MRA) is increasingly used to assess the nature and severity of stenotic blood vessels. Flow artifacts associated with high flows and/or narrow constrictions may confuse the interpretation of these studies. Accurate TOF/MRA evaluations demand an...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199307000-00011

    authors: Sebok NR,Sebok DA,Wilkerson D,Mezrich RS,Zatina M

    更新日期:1993-07-01 00:00:00

  • Detection of emphysema with computed tomography. Correlation with pulmonary function tests and chest radiography.

    abstract::We studied 60 male patients who had concurrent chest films (CXR), computed tomography scans (CT) and pulmonary function tests (PFT) to assess the sensitivity of CT and conventional films in detecting emphysema compared with PFT. We also sought to determine whether emphysema could be diagnosed by CT in patients with no...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198804000-00004

    authors: Sanders C,Nath PH,Bailey WC

    更新日期:1988-04-01 00:00:00

  • Hemodynamic effect of iodinated high-viscosity contrast medium in the rat kidney: a diffusion-weighted MRI feasibility study.

    abstract:RATIONALE AND OBJECTIVES:To assess the abilities of dynamic diffusion-weighted MRI to demonstrate the effects in vivo of a high-viscosity iodinated contrast agent on medullary and cortical blood flow in the rat kidney. METHODS:Dynamic diffusion-weighted, echoplanar MR images obtained from five b-value single-shot acqu...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-200011000-00001

    authors: Laissy JP,Menegazzo D,Dumont E,Piekarski JD,Karila-Cohen P,Chillon S,Schouman-Claeys E

    更新日期:2000-11-01 00:00:00

  • The blood-brain barrier: effects of nonionic contrast media with and without addition of Ca2+ and Mg2+.

    abstract::Trypan blue and 197HgCl2 were used as markers of the increased leakage through the blood-brain barrier which developed after selective injection of different contrast media formulations into the internal carotid arteries of rabbits. Interest was focused on a new, experimental, nonionic medium (C-29) and possible effec...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-197907000-00007

    authors: Golman K

    更新日期:1979-07-01 00:00:00

  • Model-based iterative reconstruction technique for ultralow-dose computed tomography of the lung: a pilot study.

    abstract:OBJECTIVES:The aim of this study was to assess the effectiveness of a model-based iterative reconstruction (MBIR) in improving image quality and diagnostic performance of ultralow-dose computed tomography (ULDCT) of the lung. MATERIALS AND METHODS:The institutional review board approved this study, and all patients pr...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e3182562a89

    authors: Yamada Y,Jinzaki M,Tanami Y,Shiomi E,Sugiura H,Abe T,Kuribayashi S

    更新日期:2012-08-01 00:00:00

  • Increased ablation zones using a cryo-based internally cooled bipolar RF applicator in ex vivo bovine liver.

    abstract:PURPOSE:To evaluate the feasibility of ex vivo ablation implementing a cryo-based internally cooled bipolar radiofrequency (RF) applicator and to determine the influence of power and gas pressure on the size and shape of the resulting ablation zones. MATERIALS AND METHODS:Two hundred twenty-five ablations were perform...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e3181b66d11

    authors: Rempp H,Voigtländer M,Clasen S,Kempf S,Neugebauer A,Schraml C,Schmidt D,Claussen CD,Enderle MD,Goldberg SN,Pereira PL

    更新日期:2009-12-01 00:00:00

  • Prediction of antiangiogenic treatment efficacy by iron oxide enhanced parametric magnetic resonance imaging.

    abstract:RATIONALE AND OBJECTIVES:Tools for monitoring modern target-specific antiangiogenic and antivascular therapies are highly desirable because treatment strategies are time consuming, expensive, and yet sometimes ineffective. Therefore, the aim of this experimental study was to evaluate the predictive value of steady-stat...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e3180d5cbd9

    authors: Persigehl T,Matuszewski L,Kessler T,Wall A,Meier N,Ebert W,Berdel WE,Heindel W,Mesters R,Bremer C

    更新日期:2007-12-01 00:00:00

  • Hybrid Positron Emission Tomography/Magnetic Resonance Imaging: Challenges, Methods, and State of the Art of Hardware Component Attenuation Correction.

    abstract::Attenuation correction (AC) is an essential step in the positron emission tomography (PET) data reconstruction process to provide accurate and quantitative PET images. The introduction of PET/magnetic resonance (MR) hybrid systems has raised new challenges but also possibilities regarding PET AC. While in PET/computed...

    journal_title:Investigative radiology

    pub_type: 杂志文章,评审

    doi:10.1097/RLI.0000000000000289

    authors: Paulus DH,Quick HH

    更新日期:2016-10-01 00:00:00

  • Renal effects of bicarbonate versus saline infusion for iso- and lowosmolar contrast media in rats.

    abstract:OBJECTIVE:Hydration is widely accepted as an effective measure to prevent contrast media (CM)-induced acute kidney injury (AKI). Whether bicarbonate (NaHCO₃) infusion has a greater effect than saline is disputed. Effective prevention of CM-induced AKI by NaHCO₃ has been found by several clinical trials. However, others...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e31822311a9

    authors: Ladwig M,Flemming B,Seeliger E,Sargsyan L,Persson PB

    更新日期:2011-11-01 00:00:00

  • Feasibility of real-time magnetic resonance-guided angioplasty and stenting of renal arteries in vitro and in Swine, using a new polyetheretherketone-based magnetic resonance-compatible guidewire.

    abstract:OBJECTIVES:Demonstrate the usability of a new polyetheretherketone (PEEK)-based MR-compatible guidewire for renal artery catheterization, angioplasty, and stenting under MR-guidance using MR-visible markers, in vitro and in vivo. MATERIAL AND METHODS:The new 0.035'' guidewire with fiber-reinforced PEEK core, a soft ti...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e31819b00f1

    authors: Kos S,Huegli R,Hofmann E,Quick HH,Kuehl H,Aker S,Kaiser GM,Borm PJ,Jacob AL,Bilecen D

    更新日期:2009-04-01 00:00:00

  • Phase I clinical evaluation of citrate-coated monocrystalline very small superparamagnetic iron oxide particles as a new contrast medium for magnetic resonance imaging.

    abstract:RATIONALE AND OBJECTIVES:To evaluate the safety and pharmacokinetics of a newly developed MR contrast medium consisting of very small superparamagnetic iron oxide particles (VSOP) coated with citrate (VSOP-C184) in a clinical phase I trial. METHODS:A total of 18 healthy subjects received either VSOP-C184 (core diamete...

    journal_title:Investigative radiology

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1097/01.rli.0000129472.45832.b0

    authors: Taupitz M,Wagner S,Schnorr J,Kravec I,Pilgrimm H,Bergmann-Fritsch H,Hamm B

    更新日期:2004-07-01 00:00:00

  • Validation of ultrafast computed tomographic left ventricular volume measurement.

    abstract::Left ventricular volume has been measured with ultrafast computed tomography. However, the accuracy with which this can be done is unknown. We therefore imaged with ultrafast computed tomography 11 rectangular phantoms, 20 to 225 ml, and 17 left ventricular casts, 15 to 112 ml. Two observers planimetered serial tomogr...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199101000-00006

    authors: Pietras RJ,Wolfkiel CJ,Veselik K,Roig E,Chomka EV,Brundage BH

    更新日期:1991-01-01 00:00:00

  • Control of experimental traumatic hepatic hemorrhage by transcatheter embolization.

    abstract::The feasibility of control of traumatic hepatic hemorrhage by angiographic transcatheter embolization was investigated. Bleeding sites were created in the livers of each of twelve dogs, and the hepatic artery was occluded with Gelfoam. Successful control of bleeding was demonstrated by postembolization angiography in ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-197801000-00014

    authors: Tyler T,Rosenbaum HD

    更新日期:1978-01-01 00:00:00

  • Establishing Reference Intervals for Gadolinium Concentrations in Blood, Plasma, and Urine in Individuals Not Previously Exposed to Gadolinium-Based Contrast Agents.

    abstract:OBJECTIVES:Over the recent years, there have been increasing concerns that exposure to gadolinium-based contrast agents (GBCAs) may be associated with retention of Gd within the skin, bones, and solid organs in patients with normal renal function, although the clinical implications of this deposition remain to be estab...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000657

    authors: Layne KA,Wood DM,Dixon-Zegeye M,Archer JRH,Raja K,Dargan PI

    更新日期:2020-07-01 00:00:00

  • Influence of paramagnetic ions and pH on proton NMR relaxation of biologic fluids.

    abstract::The extent to which various concentrations of the paramagnetic metal ions [gadolinium (III), manganese (II), chromium (III), iron (III), nickel (II), copper (II), and cobalt (II)] affect proton magnetic relaxation times of distilled water, 4% human serum albumin (HSA), and dog plasma was studied in vitro. The pH of wa...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198602000-00009

    authors: Barnhart JL,Berk RN

    更新日期:1986-02-01 00:00:00

  • Ventral sacroiliac ligament. Anatomic and pathologic considerations.

    abstract:RATIONALE AND OBJECTIVES:The ventral sacroiliac ligament (VSL), which bridges the sacroiliac (SI) joint anteriorly, has been described as an important stabilizing structure of the joint, but no data exist regarding its assessment with routine and advanced imaging methods. The authors determine the imaging appearance of...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199608000-00009

    authors: Jaovisidha S,Ryu KN,De Maeseneer M,Haghighi P,Goodwin D,Sartoris DJ,Resnick D

    更新日期:1996-08-01 00:00:00

  • Sequential change of MR signal intensity of the brain after manganese administration in rabbits. Correlation with manganese concentration and histopathologic findings.

    abstract:RATIONALE AND OBJECTIVES:High signal intensity in the basal ganglia on T1-weighted MR imaging has been reported in chronic manganese (Mn) poisoning. However, the exact meaning of the high signal intensity remains unclear: does it result from Mn itself, secondary pathologic changes of the brain tissue, or both? The goal...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199906000-00001

    authors: Kim SH,Chang KH,Chi JG,Cheong HK,Kim JY,Kim YM,Han MH

    更新日期:1999-06-01 00:00:00

  • Toward clinical X-ray phase-contrast CT: demonstration of enhanced soft-tissue contrast in human specimen.

    abstract:OBJECTIVES:X-ray computed tomography (CT) using phase contrast can provide images with greatly enhanced soft-tissue contrast in comparison to conventional attenuation-based CT. We report on the first scan of a human specimen recorded with a phase-contrast CT system based on an x-ray grating interferometer and a convent...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e3181e21866

    authors: Donath T,Pfeiffer F,Bunk O,Grünzweig C,Hempel E,Popescu S,Vock P,David C

    更新日期:2010-07-01 00:00:00

  • Some practical issues of experimental design and data analysis in radiological ROC studies.

    abstract::Receiver operating characteristic (ROC) analysis has been used in a broad variety of medical imaging studies during the past 15 years, and its advantages over more traditional measures of diagnostic performance are now clearly established. But despite the essential simplicity of the approach, workers in the field ofte...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198903000-00012

    authors: Metz CE

    更新日期:1989-03-01 00:00:00

  • Heavily Calcified Coronary Arteries: Advanced Calcium Subtraction Improves Luminal Visualization and Diagnostic Confidence in Dual-Energy Coronary Computed Tomography Angiography.

    abstract:OBJECTIVES:The aim of this study was to evaluate a prototype dual-energy computed tomography calcium subtraction algorithm and its impact on luminal visualization in patients with heavily calcified coronary arteries. MATERIALS AND METHODS:Twenty-nine patients (62% male; mean age, 64 ± 7 years) who had undergone dual-e...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000416

    authors: De Santis D,Jin KN,Schoepf UJ,Grant KL,De Cecco CN,Nance JW Jr,Vogl TJ,Laghi A,Albrecht MH

    更新日期:2018-02-01 00:00:00

  • Interleaved Mapping of Temperature and Longitudinal Relaxation Rate to Monitor Drug Delivery During Magnetic Resonance-Guided High-Intensity Focused Ultrasound-Induced Hyperthermia.

    abstract:OBJECTIVES:Magnetic resonance-guided high-intensity focused ultrasound (MR-HIFU) is a method to heat lesions noninvasively to a stable, elevated temperature and a well-suited method to induce local hyperthermia (41°C-43°C) in deep-seated tissues. Magnetic Resonance (MR) imaging provides therapy planning on anatomical i...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000392

    authors: Kneepkens E,Heijman E,Keupp J,Weiss S,Nicolay K,Grüll H

    更新日期:2017-10-01 00:00:00

  • Quantitative computed tomography of the lungs and airways in healthy nonsmoking adults.

    abstract:OBJECTIVES:The purposes of this study were to evaluate the reference range of quantitative computed tomography (QCT) measures of lung attenuation and airway parameter measurements in healthy nonsmoking adults and to identify sources of variation in those measures and possible means to adjust for them. MATERIALS AND ME...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e318262292e

    authors: Zach JA,Newell JD Jr,Schroeder J,Murphy JR,Curran-Everett D,Hoffman EA,Westgate PM,Han MK,Silverman EK,Crapo JD,Lynch DA,COPDGene Investigators.

    更新日期:2012-10-01 00:00:00

  • New contrast media designed for x-ray energy subtraction imaging in digital mammography.

    abstract:RATIONALE AND OBJECTIVES:In contrast-enhanced dual-energy subtraction imaging 2 images acquired postcontrast media administration at different energies are subtracted to highlight structures hidden in the absence of contrast media. X-ray spectra of the newly developed digital full-field mammography units (GE Senographe...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/01.RLI.0000077124.24140.bd

    authors: Lawaczeck R,Diekmann F,Diekmann S,Hamm B,Bick U,Press WR,Schirmer H,Schön K,Weinmann HJ

    更新日期:2003-09-01 00:00:00