Clinical comparison between a currently available single-loop and an investigational dual-channel endorectal receive coil for prostate magnetic resonance imaging: a feasibility study at 1.5 and 3 T.

Abstract:

OBJECTIVES:The objectives of this study were to test the feasibility of an investigational dual-channel next-generation endorectal coil (NG-ERC) in vivo, to quantitatively assess signal-to-noise ratio (SNR), and to get an impression of image quality compared with the current clinically available single-loop endorectal coil (ERC) for prostate magnetic resonance imaging at both 1.5 and 3 T. MATERIALS AND METHODS:The study was approved by the institutional review board, and written informed consent was obtained from all patients. In total, 8 consecutive patients with prostate cancer underwent a local staging magnetic resonance examination with the successive use of both coils in 1 session (4 patients at 1.5 T and 4 other patients at 3 T). Quantitative comparison of both coils was performed for the apex, mid-gland and base levels at both field strengths by calculating SNR profiles in the axial plane on an imaginary line in the anteroposterior direction perpendicular to the coil surface. Two radiologists independently assessed the image quality of the T2-weighted and apparent diffusion coefficient maps calculated from diffusion-weighted imaging using a 5-point scale. Improvement of geometric distortion on diffusion-weighted imaging with the use of parallel imaging was explored. Statistical analysis included a paired Wilcoxon signed rank test for SNR and image quality evaluation as well as κ statistics for interobserver agreement. RESULTS:No adverse events were reported. The SNR was higher for the NG-ERC compared with the ERC up to a distance of approximately 40 mm from the surface of the coil at 1.5 T (P < 0.0001 for the apex, the mid-gland, and the base) and approximately 17 mm (P = 0.015 at the apex level) and 30 mm at 3 T (P < 0.0001 for the mid-gland and base). Beyond this distance, the SNR profiles of both coils were comparable. Overall, T2-weighted image quality was considered better for NG-ERC at both field strengths. Quality of apparent diffusion coefficient maps with the use of parallel imaging was rated superior with the NG-ERC at 3 T. CONCLUSIONS:The investigational NG-ERC for prostate imaging outperforms the current clinically available ERC in terms of SNR and is feasible for continued development for future use as the next generation endorectal coil for prostate imaging in clinical practice.

journal_name

Invest Radiol

journal_title

Investigative radiology

authors

Vos EK,Sambandamurthy S,Kamel M,McKenney R,van Uden MJ,Hoeks CM,Yakar D,Scheenen TW,Fütterer JJ

doi

10.1097/RLI.0b013e3182a56678

subject

Has Abstract

pub_date

2014-01-01 00:00:00

pages

15-22

issue

1

eissn

0020-9996

issn

1536-0210

journal_volume

49

pub_type

杂志文章
  • The clotting issue: etiologic factors in thromboembolism. II. Clinical considerations.

    abstract:RATIONALE AND OBJECTIVES:The authors analyze the origins of the "clotting issue," the controversy that began in the 1980s when contrast media, once perceived as good flushing agents for catheters because of their assumed anticoagulant properties, came under attack for allegedly causing thromboembolism. Laboratory studi...

    journal_title:Investigative radiology

    pub_type: 杂志文章,评审

    doi:

    authors: Dawson P,Cousins C,Bradshaw A

    更新日期:1993-11-01 00:00:00

  • Radiation hormesis. Its emerging significance in medical practice.

    abstract::Because of the strong scientific evidence in support of radiation hormesis, we can no longer ignore this concept. There is, however, need for additional, carefully documented investigations in selected biological systems exposed to LLIR if the matter of radiation hormesis is to be settled once and for all. This need s...

    journal_title:Investigative radiology

    pub_type: 杂志文章,评审

    doi:

    authors: Loken MK,Feinendegen LE

    更新日期:1993-05-01 00:00:00

  • Radiologic-pathologic-clinical correlation in mechanisms of disease course.

    abstract::The interdisciplinary approach to medical education has often been deficient in medical school curricula. Because of the nonintegrated approach to medical education, problem solving capabilities are not fostered. The clinical presentation of a patient, the imaging modalities used to investigate the patient, and the ul...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198604000-00015

    authors: Oldham SA,Jacobson F

    更新日期:1986-04-01 00:00:00

  • Temporal changes in the oxidation state in in vitro blood.

    abstract::The rates at which the paramagnetic compounds deoxyhemoglobin (Hb) and methemoglobin (MHb) form in vivo within an area of hemorrhage are unknown. The present experiment establishes the baseline concentrations and rates of change in paramagnetic hemoglobin concentrations, as well as the pH in normal heparinized and clo...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199003000-00006

    authors: Taber KH,Migliore PJ,Pagani JJ,Ford JJ,McLauren T,Hayman LA

    更新日期:1990-03-01 00:00:00

  • Noninvasive estimation of organ weights by postmortem magnetic resonance imaging and multislice computed tomography.

    abstract:OBJECTIVE:Computed tomography (CT) and magnetic resonance imaging (MRI) are introduced as an alternative to traditional autopsy. The purpose of this study was to investigate their accuracy in mass estimation of liver and spleen. METHODS:In 44 cases, the weights of spleen and liver were estimated based on MRI and CT da...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/01.rli.0000221323.38443.8d

    authors: Jackowski C,Thali MJ,Buck U,Aghayev E,Sonnenschein M,Yen K,Dirnhofer R,Vock P

    更新日期:2006-07-01 00:00:00

  • Large-tip-angle spin-echo imaging. Theory and applications.

    abstract:RATIONALE AND OBJECTIVES:Tissue contrast phenomenology was investigated analytically and clinically for a class of magnetic resonance (MR) pulse sequences we call large-tip-angle (LTA) spin-echo (SE) imaging. In comparison to traditional SE sequences (denoted 90 degrees-180 degrees-echo), the LTA sequence is of the for...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199310000-00017

    authors: Elster AD,Provost TJ

    更新日期:1993-10-01 00:00:00

  • Delayed Gadolinium Leakage in Ocular Structures: A Potential Marker for Age- and Vascular Risk Factor-Related Small Vessel Disease?

    abstract:BACKGROUND:Gadolinium leakage in ocular structures (GLOS) was recently observed in fluid-attenuated inversion recovery (FLAIR) images obtained the day after an initial gadolinium injection in stroke patients. The specificity of GLOS to stroke and its mechanisms remain unclear. OBJECTIVE:We investigated the factors ass...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000757

    authors: Galmiche C,Moal B,Marnat G,Sagnier S,Schweitzer C,Dousset V,Sibon I,Tourdias T

    更新日期:2021-01-19 00:00:00

  • Polycystic kidney disease evaluation by magnetic resonance imaging in ischemia-reperfusion injured PKD1 knockout mouse model: comparison of T2-weighted FSE and true-FISP.

    abstract:OBJECTIVE:To investigate the efficacy of true fast imaging with steady state precession (true-FISP) compared with T2-weighted fast spin echo (T2W-FSE) in monitoring changes in cyst volume and renal expansion in an ischemia reperfusion (IR) injured PKD1 knockout (IKO) mouse model. MATERIALS AND METHODS:The animal study...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e3181be3501

    authors: Zhou X,Bao H,Takakura A,Zhou J,Albert M,Sun Y

    更新日期:2010-01-01 00:00:00

  • Pharmacokinetics and safety of gadobutrol-enhanced magnetic resonance imaging in pediatric patients.

    abstract:OBJECTIVES:This clinical study investigated the pharmacokinetics and safety of gadobutrol, a magnetic resonance (MR) imaging extracellular contrast agent, in pediatric patients aged 2 to 17 years. MATERIALS AND METHODS:In this open-label, multicenter study, patients scheduled for routine contrast-enhanced MR imaging o...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e3181bfe2d2

    authors: Hahn G,Sorge I,Gruhn B,Glutig K,Hirsch W,Bhargava R,Furtner J,Born M,Schröder C,Ahlström H,Kaiser S,Moritz JD,Kunze CW,Shroff M,Stokland E,Trnkova ZJ,Schultze-Mosgau M,Reif S,Bacher-Stier C,Mentzel HJ

    更新日期:2009-12-01 00:00:00

  • Experimental renal papillary necrosis in rats: microangiographic and tubular micropuncture injection studies.

    abstract::Proposed causes of renal papillary necrosis (RPN) include tubular toxicity due to hyperconcentration of toxins in the renal medulla and vasoconstriction of medullary vessels with ischemic necrosis. The authors studied these mechanisms in bromoethylamine hydrobromide-induced RPN in rats by microvascular and tubular mic...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198103000-00006

    authors: Cuttino JT Jr,Goss FU,Clark RL,Marr MC

    更新日期:1981-03-01 00:00:00

  • Role of red blood cell deformation in toxicity of contrast media in cerebral angiography.

    abstract::The authors investigated the effect on the brain of red blood cells that had been modified by contrast media. Rat blood was mixed with an equivolume of contrast media, and up to 200 microL of the mixture was infused to the internal carotid artery of the rat. Evans blue was administered intravenously to assess the inte...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198905000-00009

    authors: Miyazawa T,Nakagawa H,Oshino N

    更新日期:1989-05-01 00:00:00

  • Assessment of large bowel motility by cine magnetic resonance imaging using two different prokinetic agents: a feasibility study.

    abstract:OBJECTIVES:We sought to assess large bowel motility, induced by 2 prokinetic agents, senna tea and erythromycin, using functional cine magnetic resonance imaging (MRI). MATERIALS AND METHODS:Twelve volunteers underwent functional cine MRI before and after the administration of senna tea or erythromycin. The protocol c...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/01.rli.0000183054.43131.a8

    authors: Buhmann S,Kirchhoff C,Wielage C,Mussack T,Reiser MF,Lienemann A

    更新日期:2005-11-01 00:00:00

  • Increased ablation zones using a cryo-based internally cooled bipolar RF applicator in ex vivo bovine liver.

    abstract:PURPOSE:To evaluate the feasibility of ex vivo ablation implementing a cryo-based internally cooled bipolar radiofrequency (RF) applicator and to determine the influence of power and gas pressure on the size and shape of the resulting ablation zones. MATERIALS AND METHODS:Two hundred twenty-five ablations were perform...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e3181b66d11

    authors: Rempp H,Voigtländer M,Clasen S,Kempf S,Neugebauer A,Schraml C,Schmidt D,Claussen CD,Enderle MD,Goldberg SN,Pereira PL

    更新日期:2009-12-01 00:00:00

  • Magnetic resonance imaging-controlled laser-induced interstitial thermotherapy.

    abstract:RATIONALE AND OBJECTIVES:Laser-induced interstitial thermotherapy (LITT) may become an attractive modality for minimally invasive tumor therapy. Magnetic resonance imaging (MRI) could be used to assist this procedure. METHODS:A T1-weighted turbo fast low-angle shot (FLASH) sequence for on-line monitoring of the laser-...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199403000-00015

    authors: Gewiese B,Beuthan J,Fobbe F,Stiller D,Müller G,Böse-Landgraf J,Wolf KJ,Deimling M

    更新日期:1994-03-01 00:00:00

  • The allergic theory of radiocontrast agent toxicity: demonstration of antibody activity in sera of patients suffering major radiocontrast agent reactions.

    abstract::An allergic, immunologic mechanism for certain adverse reactions to radiocontrast agents has been postulated on the basis of clinical and theoretical considerations. One obstacle to the acceptance of this allergic theory has been the inability to demonstrate significant antibodies with specificity for these agents. In...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-197609000-00002

    authors: Brasch RC,Caldwell JL

    更新日期:1976-09-01 00:00:00

  • Ventral sacroiliac ligament. Anatomic and pathologic considerations.

    abstract:RATIONALE AND OBJECTIVES:The ventral sacroiliac ligament (VSL), which bridges the sacroiliac (SI) joint anteriorly, has been described as an important stabilizing structure of the joint, but no data exist regarding its assessment with routine and advanced imaging methods. The authors determine the imaging appearance of...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199608000-00009

    authors: Jaovisidha S,Ryu KN,De Maeseneer M,Haghighi P,Goodwin D,Sartoris DJ,Resnick D

    更新日期:1996-08-01 00:00:00

  • Semiautomatic lymph node segmentation in multislice computed tomography: impact of slice thickness on segmentation quality, measurement precision, and interobserver variability.

    abstract:OBJECTIVES:To determine the impact of slice thickness on semiautomatic lymph node analysis. MATERIALS AND METHODS:Thoracic multislice computed tomography (MSCT) of 46 patients with NSCLC were reconstructed at 1.0-, 3.0-, and 5.0-mm slice thickness. Two radiologists independently determined long and short axis diameter...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e3181c443e1

    authors: Buerke B,Puesken M,Beyer F,Gerss J,Weckesser M,Seifarth H,Heindel W,Wessling J

    更新日期:2010-02-01 00:00:00

  • Cine phase-contrast magnetic resonance imaging for analysis of flow phenomena in experimental aortic dissection.

    abstract::Using a 1.5 T magnetic resonance imaging (MRI) system, cine phase-contrast and magnitude images were obtained in three phantoms that simulated different anatomic configurations of aortic dissection. The dissection phantoms were made of compliant materials, and pulsatile flow was used in all experiments. Phantoms diffe...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199112000-00007

    authors: Iwai F,Sostman HD,Evans AJ,Nadel SN,Hedlund LW,Beam CA,Charles HC,Spritzer CE

    更新日期:1991-12-01 00:00:00

  • Differentiation of delayed kidney graft function with gadolinium-DTPA-enhanced magnetic resonance imaging and Doppler ultrasound.

    abstract:RATIONALE AND OBJECTIVES:The authors differentiate acute tubular necrosis from transplant rejection in patients with delayed kidney graft function using gadolinium (Gd)-DTPA enhanced magnetic resonance (MR) imaging. METHODS:Twenty-four patients after renal transplantation (10 with normal graft function, 14 with delaye...

    journal_title:Investigative radiology

    pub_type: 临床试验,杂志文章

    doi:10.1097/00004424-199606000-00009

    authors: Preidler KW,Szolar D,Schreyer H,Ebner F,Kern R,Holzer H,Horina JH

    更新日期:1996-06-01 00:00:00

  • Mitral annular shape, size, and motion in normals and in patients with cardiomyopathy: evaluation with computed tomography.

    abstract:OBJECTIVE:To assess prospectively, in healthy subjects and in patients with dilated cardiomyopathy (DCM) and hypertrophic obstructive cardiomyopathy (HOCM), the 3-dimensional (3D) shape, size, and motion of the mitral annulus (MA) using computed tomography (CT). MATERIALS AND METHODS:Twenty patients with no cardiac ab...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e3181994a73

    authors: Alkadhi H,Desbiolles L,Stolzmann P,Leschka S,Scheffel H,Plass A,Schertler T,Trindade PT,Genoni M,Cattin P,Marincek B,Frauenfelder T

    更新日期:2009-04-01 00:00:00

  • Nonenhanced magnetic resonance angiography of the lower extremity vessels at 7 tesla: initial experience.

    abstract:OBJECTIVES:The aim of this study was to investigate the feasibility of nonenhanced magnetic resonance angiography (MRA) of the lower extremities at 7 tesla (T). MATERIALS AND METHODS:Eight healthy volunteers were examined on a 7-T whole-body magnetic resonance system. For image acquisition, a custom-built 16-channel t...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e3182839c2b

    authors: Fischer A,Maderwald S,Orzada S,Johst S,Schäfer LC,Ladd ME,Nassenstein K,Umutlu L,Lauenstein TC

    更新日期:2013-07-01 00:00:00

  • Searching for lung nodules. Visual dwell indicates locations of false-positive and false-negative decisions.

    abstract::Eye position recordings made while radiologists searched chest images for lung nodules showed that regions falsely reported positive or suspicious received prolonged visual attention. Correlation of regional fixation dwell time with independent ratings of image features indicated that more than 90% of false-positive d...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:

    authors: Kundel HL,Nodine CF,Krupinski EA

    更新日期:1989-06-01 00:00:00

  • Low-Dose Characterization of Kidney Stones Using Spectral Detector Computed Tomography: An Ex Vivo Study.

    abstract:OBJECTIVES:The aim of this study was to investigate the feasibility of kidney stone composition analysis using spectral detector computed tomography scanner (SDCT) with normal- and low-dose imaging protocols. METHODS:A total of 154 stones harvested from nephrolithotripsy or nephrolithotomy with a known monocrystalline...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000468

    authors: Große Hokamp N,Salem J,Hesse A,Holz JA,Ritter M,Heidenreich A,Maintz D,Haneder S

    更新日期:2018-08-01 00:00:00

  • Specific absorption rate as a poor indicator of magnetic resonance-related implant heating.

    abstract::Recent publications of the magnetic resonance safety profile of neurostimulators, cardiac pacemakers, and other implanted devices imply that these devices are no longer a contraindication for magnetic resonance imaging. It is very promising that patients who have these implanted devices may in the future no longer be ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/01.rli.0000185898.59140.91

    authors: Nitz WR,Brinker G,Diehl D,Frese G

    更新日期:2005-12-01 00:00:00

  • Sclerotherapy of the gallbladder in pigs. Development of a balloon catheter for a single-step procedure.

    abstract::Gallbladder sclerotherapy after permanent cystic duct occlusion, to prevent gallstone recurrence in nonsurgical gallstone therapy, is at least a two-stage procedure. A balloon catheter was developed to perform gallbladder sclerotherapy with only temporary occlusion of the cystic duct, and the efficacy and safety of th...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199109000-00005

    authors: Brakel K,Laméris JS,Vergunst H,Ten Kate FJ,Nijs HG,Terpstra OT

    更新日期:1991-09-01 00:00:00

  • Activities of the Conjoint Committee. Enhancement of diagnostic radiologic research and education.

    abstract::Even though we have made much progress over the last decade, much still needs to be done. I am personally very pleased with the excellent management and authority of my coauthor, Joe Frank, in assuming the Acting Directorship of our DRRP. You will be hearing more from him in the immediate future about this research pr...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199304001-00014

    authors: Putman CE,Frank JA

    更新日期:1993-04-01 00:00:00

  • Intravascular ultrasound imaging of vascular responsiveness in isolated perfused canine arteries.

    abstract::We investigated the feasibility of using intravascular ultrasound imaging to analyze vascular physiology in various arterial beds. Canine superficial femoral, external iliac, and common carotid arteries were harvested and suspended and perfused in a bath of oxygenated, heated, physiologic salt solution. A 6-Fr, 20-MHz...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199103000-00010

    authors: Wilson MW,Webb RC,Marx MV,Meyer CR,Gallagher MA,Haarer SL,Buda AJ,Williams DM

    更新日期:1991-03-01 00:00:00

  • The use of a thrombus-specific ultrasound contrast agent to detect thrombus in arteriovenous fistulae.

    abstract:RATIONALE AND OBJECTIVES:To evaluate the use of a new thrombus-specific ultrasound contrast agent, MRX-408, in the ultrasonic detection of thrombus in arteriovenous (AV) fistulae. METHODS:Six purpose-bred mongrels with two AV fistulae each were imaged with gray-scale ultrasound 7 weeks after graft implantation before ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-200001000-00010

    authors: Unger E,Metzger P 3rd,Krupinski E,Baker M,Hulett R,Gabaeff D,Mills J,Ihnat D,McCreery T

    更新日期:2000-01-01 00:00:00

  • Expert learning system network for diagnosis of breast calcifications.

    abstract::Breast calcification diagnosis was studied by using clinical findings and computerized image processing of a mammogram in a network of trained expert learning systems (Outcome Advisor [OA]). The system was tested with records not used for training and performance was compared with radiologist. The network was 72% accu...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199106000-00004

    authors: Patrick EA,Moskowitz M,Mansukhani VT,Gruenstein EI

    更新日期:1991-06-01 00:00:00

  • Evolution of the ablation region after magnetic resonance-guided high-intensity focused ultrasound ablation in a Vx2 tumor model.

    abstract:OBJECTIVES:Volumetric magnetic resonance (MR)-guided high-intensity focused ultrasound (HIFU) is a completely noninvasive image-guided thermal ablation technique. Recently, there has been growing interest in the use of MR-HIFU for noninvasive ablation of malignant tumors. Of particular interest for noninvasive ablation...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e3182820257

    authors: Wijlemans JW,Deckers R,van den Bosch MA,Seinstra BA,van Stralen M,van Diest PJ,Moonen CT,Bartels LW

    更新日期:2013-06-01 00:00:00