Pharmacokinetics and safety of gadobutrol-enhanced magnetic resonance imaging in pediatric patients.

Abstract:

OBJECTIVES:This clinical study investigated the pharmacokinetics and safety of gadobutrol, a magnetic resonance (MR) imaging extracellular contrast agent, in pediatric patients aged 2 to 17 years. MATERIALS AND METHODS:In this open-label, multicenter study, patients scheduled for routine contrast-enhanced MR imaging of the brain, spine, liver or kidney, or MR angiography received a single intravenous injection of gadobutrol (0.1 mmol/kg/0.1 mL/kg). Patients were stratified by age groups (2-6, 7-11, and 12-17 years). Blood and urine samples were collected at prespecified time points and analyzed for gadolinium concentrations. Plasma data were evaluated by means of a nonlinear mixed effects model, and urine data were analyzed using descriptive statistics. In addition, the safety of gadobutrol was evaluated. RESULTS:A total of 130 patients (2-6 years, n = 45; 7-11 years, n = 39; 12-17 years, n = 46) were included in the final population pharmacokinetic analysis. Gadobutrol pharmacokinetics in children aged 2 to 17 years were adequately described by an open 2-compartment model with elimination from the central compartment. The median estimates (2.5th percentile, 97.5th percentile) of body weight-normalized total body clearance (L/h/kg) per age group were 0.10 (0.05, 0.17) for all ages, 0.13 (0.09, 0.17) in the 2 to 6 year age group, 0.10 (0.05, 0.17) in the 7 to 11 year age group and 0.09 (0.05, 0.10) in the 12 to 17 year age group. The body weight-normalized median estimates of total volume of distribution (L/kg) were 0.20 (0.12, 0.28) for all ages, 0.24 (0.20, 0.28) in the 2 to 6 year age group, 0.19 (0.14, 0.23) in the 7 to 11 year age group and 0.18 (0.092, 0.23) in the 12 to 17 year age group. Median gadolinium plasma concentrations at 20 minutes postinjection were simulated using the population pharmacokinetic model and ranged from 414 (13 kg subject) to 518 micromol/L (65 kg subject). Body weight was identified as the major covariate influencing the pharmacokinetic parameters of total body clearance and central volume of distribution. Age was not found to be an additional independent parameter. The median amount of renally excreted gadolinium was 77.0% of the administered dose within 6 hours postinjection, indicating that gadobutrol was renally excreted in this pediatric population aged 2 to 17 years. Gadobutrol was well tolerated, with drug-related adverse events of mild intensity reported for 8 (5.8%) of 138 patients. CONCLUSIONS:Observed differences in pharmacokinetics were attributed to body weight, with no additional independent effect of age. Thus, no dose adjustment from the standard dose of gadobutrol in adults based on body weight (0.1 mmol/kg) is necessary in pediatric patients aged 2 to 17 years. Gadobutrol was safe and well tolerated in the pediatric population in this study.

journal_name

Invest Radiol

journal_title

Investigative radiology

authors

Hahn G,Sorge I,Gruhn B,Glutig K,Hirsch W,Bhargava R,Furtner J,Born M,Schröder C,Ahlström H,Kaiser S,Moritz JD,Kunze CW,Shroff M,Stokland E,Trnkova ZJ,Schultze-Mosgau M,Reif S,Bacher-Stier C,Mentzel HJ

doi

10.1097/RLI.0b013e3181bfe2d2

subject

Has Abstract

pub_date

2009-12-01 00:00:00

pages

776-83

issue

12

eissn

0020-9996

issn

1536-0210

journal_volume

44

pub_type

杂志文章
  • Towards computer analysis of pulmonary infiltration.

    abstract::A feasibility study is described to provide quantitative texture measures to distinguish between normal lung, alveolar infiltrates and interstitial infiltrates. Advanced computer imaging technology and decision making processes were applied to distinguish between these textural patterns. The results, based on computer...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-197807000-00005

    authors: Tully RJ,Conners RW,Harlow CA,Lodwick GS

    更新日期:1978-07-01 00:00:00

  • Interleaved Mapping of Temperature and Longitudinal Relaxation Rate to Monitor Drug Delivery During Magnetic Resonance-Guided High-Intensity Focused Ultrasound-Induced Hyperthermia.

    abstract:OBJECTIVES:Magnetic resonance-guided high-intensity focused ultrasound (MR-HIFU) is a method to heat lesions noninvasively to a stable, elevated temperature and a well-suited method to induce local hyperthermia (41°C-43°C) in deep-seated tissues. Magnetic Resonance (MR) imaging provides therapy planning on anatomical i...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000392

    authors: Kneepkens E,Heijman E,Keupp J,Weiss S,Nicolay K,Grüll H

    更新日期:2017-10-01 00:00:00

  • Contrast media for CT. An analysis of the early pharmacokinetics.

    abstract::Iohexol and meglumine-sodium diatrizoate were injected intravenously into 18 pigs as either a 99:1 or 1:99 mixture. Blood samples were taken for 30 minutes and the concentration of each of the two contrast media was measured by means of a double labeling technique with 125I and 131I. Relative concentrations of iohexol...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198511000-00016

    authors: Jensen LI,Dean PB,Nyman U,Golman K

    更新日期:1985-11-01 00:00:00

  • Arterial blood flow measurement: assessment of velocity estimation methods.

    abstract::Three methods are presented which provide statistically acceptable estimates of mean transit time of opacified blood during angiography. While the methods vary in precision, the selection of the method appropriate for any particular experimental model depends on the degree of precision required to demonstrate the effe...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-197707000-00004

    authors: Silverman NR,Rosen L

    更新日期:1977-07-01 00:00:00

  • Estimating digital information throughput rates for radiology networks. A model.

    abstract::The design and implementation of a digital radiology image management system requires the definition, evaluation, and comparison of appropriate measures of system performance. The mean throughput rate is an important measure of the actual performance of a finished system. The mean throughput rate identifies the transm...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198602000-00014

    authors: Cox GG,Templeton AW,Anderson WH,Cook LT,Hensley KS,Dwyer SJ 3rd

    更新日期:1986-02-01 00:00:00

  • The current status of total joint replacement.

    abstract::The last two decades have witnessed tremendous strides in the evolution of acceptable and successful methods of prosthetic replacement for the arthritic joint. By and large, these techniques are predictable and durable, though not always to the complete satisfaction of the patient and surgeon. Despite the recent empha...

    journal_title:Investigative radiology

    pub_type: 杂志文章,评审

    doi:10.1097/00004424-199001000-00022

    authors: Volz RG,Benjamin JB

    更新日期:1990-01-01 00:00:00

  • Influence of paramagnetic ions and pH on proton NMR relaxation of biologic fluids.

    abstract::The extent to which various concentrations of the paramagnetic metal ions [gadolinium (III), manganese (II), chromium (III), iron (III), nickel (II), copper (II), and cobalt (II)] affect proton magnetic relaxation times of distilled water, 4% human serum albumin (HSA), and dog plasma was studied in vitro. The pH of wa...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198602000-00009

    authors: Barnhart JL,Berk RN

    更新日期:1986-02-01 00:00:00

  • Detection of pulmonary nodules with move-during-scan magnetic resonance imaging using a free-breathing turbo inversion recovery magnitude sequence.

    abstract:PURPOSE:Detection of pulmonary metastases is still a challenging task for magnetic resonance imaging (MRI). It was the aim of this study to evaluate the potential of a free-breathing move-during-scan turbo inversion recovery magnitude sequence for the detection of pulmonary nodules. MATERIALS AND METHODS:The sensitivi...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e31816901fa

    authors: Baumann T,Ludwig U,Pache G,Gall C,Saueressig U,Fisch D,Stankovic Z,Bartholomae JP,Honal M,Bley TA,Langer M,Schaefer O

    更新日期:2008-06-01 00:00:00

  • Development, chemistry, and physical properties of iopamidol and its analogues.

    abstract::A series of 5-hydroxyacylamino-2,4,6-triiodo-N,N'-hydroxy-alkyl-isophtalamides was prepared in order to study the structural requirements for high water solubility and low toxicity. Among the amides substituted by 2-hydroxyethyl; 2,3-dihydroxypropyl; 1,3-dihydroxypropyl-; and 1,1-dihydroxy-methyl-2-oxyethyl- groups, t...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198011001-00065

    authors: Pitrè D,Felder E

    更新日期:1980-11-01 00:00:00

  • Magnetic resonance imaging and histologic findings of experimental cerebral fat embolism.

    abstract:RATIONALE AND OBJECTIVES:The purpose of this study was to determine whether cerebral fat embolism demonstrated reversible or irreversible findings in magnetic resonance (MR) imaging over time and to compare the features in MR images with histologic findings in a cat model. MATERIALS AND METHODS:MR images were obtained...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/01.rli.0000077055.48406.e2

    authors: Kim HJ,Lee CH,Lee SH,Moon TY

    更新日期:2003-10-01 00:00:00

  • Identifying tumor vascular permeability heterogeneity with magnetic resonance imaging contrast agents.

    abstract:RATIONALE AND OBJECTIVES:Dynamic contrast enhanced (DCE) MR mammography (MRM) uses tumor capillary density differences for prognosis. The heterogeneous response of permeability-surface area products (PS = Kp<-->t) was examined in mammary tumors, as a function of contrast agent size, to determine what effect ROI size mi...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-200204000-00003

    authors: Aref M,Brechbiel M,Wiener EC

    更新日期:2002-04-01 00:00:00

  • Pancreatic Steatosis Is Associated With Impaired Exocrine Pancreatic Function.

    abstract:OBJECTIVES:The aim of this study was to investigate if pancreatic steatosis measured by proton density fat fraction (PDFF) is associated with exocrine pancreatic function defined by fecal elastase concentrations. MATERIALS AND METHODS:A total of 1458 volunteers (777 women; age range, 21-88 years) underwent magnetic re...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000554

    authors: Kromrey ML,Friedrich N,Hoffmann RT,Bülow R,Völzke H,Weiss FU,Lerch MM,Motosugi U,Kühn JP

    更新日期:2019-07-01 00:00:00

  • Evaluation of neuroendocrine liver metastases: a comparison of dynamic contrast-enhanced magnetic resonance imaging and positron emission tomography/computed tomography.

    abstract:OBJECTIVES:The objective of this study was to evaluate the correlation between dynamic gadoxetic acid-enhanced magnetic resonance imaging parameters and specific uptake values (SUVs) derived from ¹⁸fluorodeoxyglucose (¹⁸F-FDG) and ⁶⁸Ga-DOTA-Tyr(3)-octreotate (⁶⁸Ga-DOTATATE) positron emission tomography/computed tomogra...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e3182a4eb4a

    authors: Armbruster M,Sourbron S,Haug A,Zech CJ,Ingrisch M,Auernhammer CJ,Nikolaou K,Paprottka PM,Rist C,Reiser MF,Sommer WH

    更新日期:2014-01-01 00:00:00

  • Estimation of chemical composition and density from computed tomography carried out at a number of energies.

    abstract::A method is presented by whichcomputed tomography scans carried out at a number of energies may be utilized to obtain cross-sectional images of density and atomic number in addition to the conventional array of linear attenuation coefficients. This type of analysis has been carried out for various substances of biolog...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-197703000-00016

    authors: McDavid WD,Waggener RG,Dennis MJ,Sank VJ,Payne WH

    更新日期:1977-03-01 00:00:00

  • Comparison of vascular opacification after bolus injection of iodixanol-320 iohexol-350.

    abstract:RATIONALE AND OBJECTIVES:The vascular opacification characteristics of a new nonionic, dimeric contrast agent, iodixanol, have been compared with a nonionic, monomeric agent, iohexol, using ultrafast computed tomography (UFCT). METHODS:In 10 experiments with mongrel dogs, the contrast agents were alternately injected ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199212000-00011

    authors: Gould R,Brasch RC,Sievers R,Baxter A,Aicher K

    更新日期:1992-12-01 00:00:00

  • Whole-body diffusion-weighted imaging with apparent diffusion coefficient mapping for treatment response assessment in patients with diffuse large B-cell lymphoma: pilot study.

    abstract:OBJECTIVES:The aim of this pilot study was to assess post-treatment apparent diffusion coefficient (ADC) changes of diffuse large B-cell lymphoma lesions on respiratory-gated whole-body diffusion-weighted imaging (DWI), with integrated (18)F-fluoro-2-deoxyglucose positron emission tomography/computed tomography (PET/CT...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e3182087b03

    authors: Lin C,Itti E,Luciani A,Zegai B,Lin SJ,Kuhnowski F,Pigneur F,Gaillard I,Paone G,Meignan M,Haioun C,Rahmouni A

    更新日期:2011-05-01 00:00:00

  • Increased ablation zones using a cryo-based internally cooled bipolar RF applicator in ex vivo bovine liver.

    abstract:PURPOSE:To evaluate the feasibility of ex vivo ablation implementing a cryo-based internally cooled bipolar radiofrequency (RF) applicator and to determine the influence of power and gas pressure on the size and shape of the resulting ablation zones. MATERIALS AND METHODS:Two hundred twenty-five ablations were perform...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e3181b66d11

    authors: Rempp H,Voigtländer M,Clasen S,Kempf S,Neugebauer A,Schraml C,Schmidt D,Claussen CD,Enderle MD,Goldberg SN,Pereira PL

    更新日期:2009-12-01 00:00:00

  • Heavily Calcified Coronary Arteries: Advanced Calcium Subtraction Improves Luminal Visualization and Diagnostic Confidence in Dual-Energy Coronary Computed Tomography Angiography.

    abstract:OBJECTIVES:The aim of this study was to evaluate a prototype dual-energy computed tomography calcium subtraction algorithm and its impact on luminal visualization in patients with heavily calcified coronary arteries. MATERIALS AND METHODS:Twenty-nine patients (62% male; mean age, 64 ± 7 years) who had undergone dual-e...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000416

    authors: De Santis D,Jin KN,Schoepf UJ,Grant KL,De Cecco CN,Nance JW Jr,Vogl TJ,Laghi A,Albrecht MH

    更新日期:2018-02-01 00:00:00

  • Comparison of open- and closed-chest canine model for quantification of coronary stenosis severity by myocardial contrast echocardiography.

    abstract:RATIONALE AND OBJECTIVES:The objective of the present study was to compare the data regarding the ability of real-time myocardial contrast echocardiography (MCE) to assess altered myocardial blood flow produced by graded coronary stenoses between open- and closed-chest canine models. MATERIALS AND METHODS:Three grades...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-200301000-00006

    authors: Masugata H,Peters B,Lafitte S,Yao B,Strachan M,Ling Kwan O,Ohmori K,Mizushige K,Kohno M

    更新日期:2003-01-01 00:00:00

  • Potential of dose reduction after marker placement with full-field digital mammography.

    abstract:OBJECTIVES:The purpose of our study was to assess the potential for radiation dose reduction in digital postinterventional digital mammograms after marker placement. MATERIALS AND METHODS:One hundred consecutive cases of marker placement (hook-wire localization or postbiopsy clip marker placement), with 200 full-field...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/01.rli.0000163743.63063.9f

    authors: Riedl CC,Jaromi S,Floery D,Pfarl G,Fuchsjaeger MH,Helbich TH

    更新日期:2005-06-01 00:00:00

  • Comparing kidney perfusion using noncontrast arterial spin labeling MRI and microsphere methods in an interventional swine model.

    abstract:OBJECTIVE:The purpose of this study was to assess the ability of a flow-sensitive alternating inversion recovery-arterial spin labeling (FAIR-ASL) technique to track renal perfusion changes during pharmacologic and physiologic alterations in renal blood flow using microspheres as a gold standard. MATERIALS AND METHODS...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e3181f5e101

    authors: Artz NS,Wentland AL,Sadowski EA,Djamali A,Grist TM,Seo S,Fain SB

    更新日期:2011-02-01 00:00:00

  • Efficacy of gadoteridol for magnetic resonance imaging of the brain and spine.

    abstract:RATIONALE AND OBJECTIVES:The efficacy of gadoteridol for contrast enhancement of central nervous system pathology was assessed in a multicenter clinical trial involving 411 patients suspected of having intracranial or spinal pathology. METHODS:Magnetic resonance imaging was performed before and after intravenous admin...

    journal_title:Investigative radiology

    pub_type: 临床试验,杂志文章,多中心研究,随机对照试验

    doi:

    authors: Runge VM,Bronen RA,Davis KR

    更新日期:1992-08-01 00:00:00

  • The pediatric tracheostomy: III). An appraisal of xerography.

    abstract::Comparatively new in the roentgen evaluation of infants and children, xerography would appear to be ideal for portraying the pediatric airway. Since the radiation dose of xerography is higher than conventional radiography, its image quality is the subject of careful scrutiny in a pediatric setting here described in 23...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-197807000-00002

    authors: Scott JR,Kramer SS,Griscom NT

    更新日期:1978-07-01 00:00:00

  • Clinical Evaluation of a Multiparametric Deep Learning Model for Glioblastoma Segmentation Using Heterogeneous Magnetic Resonance Imaging Data From Clinical Routine.

    abstract:OBJECTIVES:The aims of this study were, first, to evaluate a deep learning-based, automatic glioblastoma (GB) tumor segmentation algorithm on clinical routine data from multiple centers and compare the results to a ground truth, manual expert segmentation, and second, to evaluate the quality of the segmentation results...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000484

    authors: Perkuhn M,Stavrinou P,Thiele F,Shakirin G,Mohan M,Garmpis D,Kabbasch C,Borggrefe J

    更新日期:2018-11-01 00:00:00

  • Detection and characterization of crystal suspensions using single-source dual-energy computed tomography: a phantom model of crystal arthropathies.

    abstract:OBJECTIVES:The aim of this study was to perform phantom measurements to prove the feasibility of single-source dual-energy computed tomography (DECT) of the extremities using a volume scan mode. In addition, we, for the first time, wanted to determine which concentrations of monosodium urate (MSU) in gout and calcium p...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000099

    authors: Diekhoff T,Kiefer T,Stroux A,Pilhofer I,Juran R,Mews J,Blobel J,Tsuyuki M,Ackermann B,Hamm B,Hermann KG

    更新日期:2015-04-01 00:00:00

  • Ultrasonic echoes registered from erythrocytes.

    abstract::Erythrocytes at various concentrations were examined with a sensitive A-mode ultrasonic scanner; simultaneous measurements were made under light microscopic control. Individual erythrocytes caused weak (about 1 dB) echoes while erythrocyte aggregates (ten to 100 cells) produced stronger echoes (up to 15 dB), grossly p...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198508000-00014

    authors: Alanen A,Kormano M

    更新日期:1985-08-01 00:00:00

  • Evaluation of radiologist interpretive performance using blinded reads by multiple external readers.

    abstract:OBJECTIVE:To demonstrate a method of assessing radiologic diagnostic agreement utilizing multiple blinded external readers. METHODS:Six body CT studies interpreted by one reader (primary reader) at the host institution were compiled with patient identifiers removed. Brief clinical histories that were available to the ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e3181d2ee97

    authors: Ryan AF,Semelka RC,Molina PL,Yonkers S,Vaidean G

    更新日期:2010-04-01 00:00:00

  • Digital radiography versus conventional radiography for the detection of a skull fracture under varying exposure parameters.

    abstract:RATIONALE AND OBJECTIVES:The effect of varying exposure parameters on the detectability of a fracture with digital and conventional radiography were examined. METHODS:A macerated fractured skull was imaged by film-screen radiography (FSR) and digital storage phosphor radiography (DR) with various exposure values. Five...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199303000-00010

    authors: Langen HJ,Klein HM,Wein B,Schiwy-Bochat KH,Stargardt A,Günther RW

    更新日期:1993-03-01 00:00:00

  • Dynamic Contrast-Enhanced Magnetic Resonance Imaging for Quantitative Lung Perfusion Imaging Using the Dual-Bolus Approach: Comparison of 3 Contrast Agents and Recommendation of Feasible Doses.

    abstract:OBJECTIVE:The aims of this study were to compare 3 contrast agents and to define feasible doses for quantitative lung perfusion imaging using the dual-bolus approach in dynamic contrast-enhanced (DCE) magnetic resonance imaging (MRI). MATERIALS AND METHODS:Ten healthy volunteers (6 males, 4 females; mean age, 23.5 yea...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000224

    authors: Veldhoen S,Oechsner M,Fischer A,Weng AM,Kunz AS,Bley TA,Köstler H,Ritter CO

    更新日期:2016-03-01 00:00:00

  • A double-blind comparative study of Hexabrix and Renografin-76 in aortography and visceral arteriography.

    abstract::A diatrizoate compound (Renografin-76) and low osmolality Hexabrix were compared in a double-blind study of 50 adults undergoing arteriographic examination. Subjective and objective assessment of pain reaction for each contrast injection rated lower overall for Hexabrix. Discomfort associated with Renografin was great...

    journal_title:Investigative radiology

    pub_type: 临床试验,杂志文章

    doi:10.1097/00004424-198411001-00012

    authors: Barth KH,Mertens MA

    更新日期:1984-11-01 00:00:00