Arterial blood flow measurement: assessment of velocity estimation methods.

Abstract:

:Three methods are presented which provide statistically acceptable estimates of mean transit time of opacified blood during angiography. While the methods vary in precision, the selection of the method appropriate for any particular experimental model depends on the degree of precision required to demonstrate the effect under investigation. As the day follows the night, the cost of equipment increases with increasing precision and the inexpensive method may provide sufficient accuracy for most clinical situations.

journal_name

Invest Radiol

journal_title

Investigative radiology

authors

Silverman NR,Rosen L

doi

10.1097/00004424-197707000-00004

subject

Has Abstract

pub_date

1977-07-01 00:00:00

pages

319-24

issue

4

eissn

0020-9996

issn

1536-0210

journal_volume

12

pub_type

杂志文章
  • Reduction of Metal Artifacts and Improvement in Dose Efficiency Using Photon-Counting Detector Computed Tomography and Tin Filtration.

    abstract:OBJECTIVES:The aim of this study was to investigate the impact on metal artifacts and dose efficiency of using a tin filter in combination with high-energy threshold (TH) images of a photon-counting detector (PCD) computed tomography (CT) system. MATERIALS AND METHODS:A 3D-printed spine with pedicle screws was scanned...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000535

    authors: Zhou W,Bartlett DJ,Diehn FE,Glazebrook KN,Kotsenas AL,Carter RE,Fletcher JG,McCollough CH,Leng S

    更新日期:2019-04-01 00:00:00

  • Screening mammography. A risk versus risk decision.

    abstract::The potential risk of a radiologic procedure often is compared with the potential benefit of the procedure. While risk vs. benefit analysis has been useful as a step toward increased communication and understanding among radiologists, referring physicians, and the general public, it has the disadvantage that risk and ...

    journal_title:Investigative radiology

    pub_type: 杂志文章,评审

    doi:10.1097/00004424-198901000-00005

    authors: Ritenour ER,Hendee WR

    更新日期:1989-01-01 00:00:00

  • A large animal model (swine) to study the diagnosis and treatment of cholelithiasis.

    abstract::Human gallstones were surgically placed into the gallbladders of 200 swine. Eight of these swine were used as a prospective series to verify that the placement and presence of human gallstones in their gallbladders caused no significant pathologic changes in the gallbladder and that the gallstones were not spontaneous...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198902000-00005

    authors: Griffith SL,Burney BT,Fry FJ,Franklin TD Jr

    更新日期:1989-02-01 00:00:00

  • Sequential change of MR signal intensity of the brain after manganese administration in rabbits. Correlation with manganese concentration and histopathologic findings.

    abstract:RATIONALE AND OBJECTIVES:High signal intensity in the basal ganglia on T1-weighted MR imaging has been reported in chronic manganese (Mn) poisoning. However, the exact meaning of the high signal intensity remains unclear: does it result from Mn itself, secondary pathologic changes of the brain tissue, or both? The goal...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199906000-00001

    authors: Kim SH,Chang KH,Chi JG,Cheong HK,Kim JY,Kim YM,Han MH

    更新日期:1999-06-01 00:00:00

  • A silicone gel phantom suitable for multimodality imaging.

    abstract::A silicone gel phantom material is described. It can be molded into any shape and it can contain internal cavities. The material is selfsealing allowing the cavities to be filled with liquids. A simple geometric phantom consisting of a rectangular solid with a single internal spherical cavity was fabricated and imaged...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198702000-00013

    authors: Goldstein DC,Kundel HL,Daube-Witherspoon ME,Thibault LE,Goldstein EJ

    更新日期:1987-02-01 00:00:00

  • Effect of increasing current and decreasing blood flow for transcatheter electrocoagulation (TCEC).

    abstract::Arterial occlusion by direct-current transcatheter electrocoagulation (TCEC) has been developed experimentally and used successfully in clinical situations. The major shortcoming of the technique has been the lengthy time necessary for occlusion of larger arteries. In the present study we attempted to decrease the tim...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198203000-00011

    authors: Ralston MD,Woodfield S,Halvorsen R,Pizzo SV,Thompson WM

    更新日期:1982-03-01 00:00:00

  • Magnetic resonance imaging contrast enhancement of brain tumors at 3 tesla versus 1.5 tesla.

    abstract:RATIONALE AND OBJECTIVES:To compare the diagnostic efficacy of a standard dose of MRI contrast agent in the evaluation of primary brain tumors and metastases using a high-field 3 tesla MR unit versus a 1.5 tesla MR unit. METHODS:Sixteen patients with brain tumors were examined at both field strengths using identical a...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-200203000-00003

    authors: Nöbauer-Huhmann IM,Ba-Ssalamah A,Mlynarik V,Barth M,Schöggl A,Heimberger K,Matula C,Fog A,Kaider A,Trattnig S

    更新日期:2002-03-01 00:00:00

  • The importance of nuclear magnetic relaxation dispersion (NMRD) profiles in MRI contrast media development.

    abstract::Observation of the relaxivity of MRI contrast media over a wide range of magnetic fields is not only necessary for predicting their efficiency at any field but also compulsory for understanding and improving their mechanisms of action. The best experimental approach to this problem is the field cycling method, which a...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198809001-00047

    authors: Muller RN,Vander Elst L,Rinck PA,Vallet P,Maton F,Fischer H,Roch A,Van Haverbeke Y

    更新日期:1988-09-01 00:00:00

  • Contrast and electrolyte dynamics of the intravenous pyelogram. II. Disparities in serum and urine concentrations of meglumine and anion.

    abstract::Intravenous or intra-aortic injections of meglumine iothalamate in dogs indicate a slightly different tissue distribution and excretory pattern of the meglumine cation and the iothalamate anion. Differences in serum and urinary concentrations of these ions suggest some cellular penetration of the meglumine anion. In a...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-197507000-00004

    authors: Lasser EC,Lang JH,Hamblin AE,Rosen L

    更新日期:1975-07-01 00:00:00

  • Spontaneous acute dissection of the internal carotid artery: high-resolution magnetic resonance imaging at 3.0 tesla with a dedicated surface coil.

    abstract:PURPOSE:Magnetic Resonance Imaging (MRI) has become the method of choice in the evaluation of patients with suspected cervical artery dissection (CAD). However, reliable identification of acute CAD might be impaired by the limited spatial resolution of standard 1.5 T MRI. In this preliminary study, we implemented a mul...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/01.rli.0000195836.57778.1f

    authors: Bachmann R,Nassenstein I,Kooijman H,Dittrich R,Kugel H,Niederstadt T,Kuhlenbäumer G,Ringelstein EB,Krämer S,Heindel W

    更新日期:2006-02-01 00:00:00

  • The importance of end-systole for optimal reconstruction protocol of coronary angiography with 16-slice multidetector computed tomography.

    abstract:OBJECTIVES:Multidetector-row computed tomography coronary images are usually analyzed in mid-diastole (MD). Because of slow coronary motion also in end-systole (ES), we evaluated the impact on image quality of including ES images and defined an efficient reconstruction protocol. MATERIAL AND METHODS:In 50 coronary mul...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/01.rli.0000153930.34439.e4

    authors: Sanz J,Rius T,Kuschnir P,Fuster V,Goldberg J,Ye XY,Wisdom P,Poon M

    更新日期:2005-03-01 00:00:00

  • Evaluation of complex joint motion with computer-based analysis of fluoroscopic sequences.

    abstract:RATIONALE AND OBJECTIVES:To develop a computer-assisted analysis of complex joint motion based on standard fluoroscopic sequences. MATERIALS AND METHODS:Fluoroscopic sequences of 10 normal shoulders and 20 patients after total shoulder arthroplasty were recorded during abduction and adduction. The analysis of the shou...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-200202000-00004

    authors: Pfirrmann CW,Huser M,Székely G,Hodler J,Gerber C

    更新日期:2002-02-01 00:00:00

  • Searching for lung nodules. Visual dwell indicates locations of false-positive and false-negative decisions.

    abstract::Eye position recordings made while radiologists searched chest images for lung nodules showed that regions falsely reported positive or suspicious received prolonged visual attention. Correlation of regional fixation dwell time with independent ratings of image features indicated that more than 90% of false-positive d...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:

    authors: Kundel HL,Nodine CF,Krupinski EA

    更新日期:1989-06-01 00:00:00

  • Developments in X-Ray Contrast Media and the Potential Impact on Computed Tomography.

    abstract::Over the past 120 years, continuous developments in medical imaging has improved diagnosis and treatment for many diseases and has thereby improved treatment outcome and quality of life of many patients. The number of computed tomography (CT) examinations is today increasing by 4% per year worldwide, for a total of ap...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000696

    authors: Schöckel L,Jost G,Seidensticker P,Lengsfeld P,Palkowitsch P,Pietsch H

    更新日期:2020-09-01 00:00:00

  • Clinical Evaluation of a Multiparametric Deep Learning Model for Glioblastoma Segmentation Using Heterogeneous Magnetic Resonance Imaging Data From Clinical Routine.

    abstract:OBJECTIVES:The aims of this study were, first, to evaluate a deep learning-based, automatic glioblastoma (GB) tumor segmentation algorithm on clinical routine data from multiple centers and compare the results to a ground truth, manual expert segmentation, and second, to evaluate the quality of the segmentation results...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000484

    authors: Perkuhn M,Stavrinou P,Thiele F,Shakirin G,Mohan M,Garmpis D,Kabbasch C,Borggrefe J

    更新日期:2018-11-01 00:00:00

  • The role of catheters and guidewires in the production of angiographic thromboembolic complications.

    abstract::Thromboembolic complications occurring during angiography may result from a number of different causes. Catheters and guidewires can interact with blood to form thrombi; this tendency is related to wall defects and the chemical composition and structural characteristics of the catheters and guidewires. Nonthrombic sou...

    journal_title:Investigative radiology

    pub_type: 杂志文章,评审

    doi:10.1097/00004424-198811002-00009

    authors: Kido DK,King PD,Manzione JV,Simon JH

    更新日期:1988-11-01 00:00:00

  • Interventional atrioseptostomy by application of monopolar high-frequency alternating current. In vitro evaluation of a new device.

    abstract:RATIONALE AND OBJECTIVES:The authors evaluate the use of a new device for interventional creation of atrial septal defects (ASD) working with high-frequency alternating current in an in vitro study with porcine atria. METHODS:The device consists of a symmetrical cage of six superelastic monofile wires, including a mic...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199702000-00003

    authors: Grabitz RG,Handt S,Vanopbroeke HJ,Seghaye MC,Franke A,Osypka P,von Bernuth G

    更新日期:1997-02-01 00:00:00

  • Magnetic resonance microscopy of the rat carotid artery at 300 megahertz.

    abstract:RATIONALE AND OBJECTIVES:Magnetic resonance microscopy (MRM) has evolved from a technical curiosity to a tool with which researchers can study important disease models. But MRM is not simply an extension of clinical magnetic resonance imaging. In this article, the unique adaptations of MRM required in the study of caro...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199409000-00004

    authors: Arnder L,Zhou X,Cofer GP,Hedlund LW,Johnson GA

    更新日期:1994-09-01 00:00:00

  • Evaluation of Gd-EOB-DTPA uptake in a perfused and isolated mouse liver model: correlation between magnetic resonance imaging and monochromatic quantitative computed tomography.

    abstract:OBJECTIVES:The aim of this work was to quantitatively evaluate the pharmacokinetic pattern of Gd-EOB-DTPA in a model of isolated and perfused mouse liver by using magnetic resonance imaging (MRI) and monochromatic quantitative computed tomography (MQCT). MATERIALS AND METHODS:For MQCT, perfusions were realized with th...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/01.rli.0000174474.43772.58

    authors: Segers J,Le Duc G,Laumonier C,Troprès I,Elst LV,Muller RN

    更新日期:2005-09-01 00:00:00

  • Solid, part-solid, or non-solid?: classification of pulmonary nodules in low-dose chest computed tomography by a computer-aided diagnosis system.

    abstract:OBJECTIVES:The purpose of this study was to develop and validate a computer-aided diagnosis (CAD) tool for automatic classification of pulmonary nodules seen on low-dose computed tomography into solid, part-solid, and non-solid. MATERIALS AND METHODS:Study lesions were randomly selected from 2 sites participating in t...

    journal_title:Investigative radiology

    pub_type: 临床试验,杂志文章,多中心研究,随机对照试验

    doi:10.1097/RLI.0000000000000121

    authors: Jacobs C,van Rikxoort EM,Scholten ET,de Jong PA,Prokop M,Schaefer-Prokop C,van Ginneken B

    更新日期:2015-03-01 00:00:00

  • Investigation of 125I as an isotopic source for mammography.

    abstract::An isotopic radiation source 125I was investigated for use in soft tissue radiaography, with particular attention to possible use in mammography for mass screening. Film sensitivities, exposure rates, absorbed doeses, contrast and resolution were determined, and compared to conventional x-ray units. It was found that ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-197509000-00007

    authors: Fairchild R,Atkins HL,Lebowitz E,Greenberg D

    更新日期:1975-09-01 00:00:00

  • Radiation hormesis. Its emerging significance in medical practice.

    abstract::Because of the strong scientific evidence in support of radiation hormesis, we can no longer ignore this concept. There is, however, need for additional, carefully documented investigations in selected biological systems exposed to LLIR if the matter of radiation hormesis is to be settled once and for all. This need s...

    journal_title:Investigative radiology

    pub_type: 杂志文章,评审

    doi:

    authors: Loken MK,Feinendegen LE

    更新日期:1993-05-01 00:00:00

  • Multiphase magnetic resonance angiography of the abdominal and pelvic arteries: results of a bicenter multireader analysis.

    abstract:RATIONALE AND OBJECTIVES:The objective is to assess the diagnostic accuracy and interobserver variability of multiphase 3D gadolinium-enhanced magnetic resonance angiography (3D-Gd-MRA) for assessment of abdominal and pelvic vascular disease. METHODS:In 41 patients from two different institutions multiphase 3D-Gd-MRA ...

    journal_title:Investigative radiology

    pub_type: 杂志文章,多中心研究

    doi:10.1097/00004424-200201000-00005

    authors: Schoenberg SO,Essig M,Hallscheidt P,Sharafuddin MJ,Stolpen AH,Knopp MV,Yuh WT

    更新日期:2002-01-01 00:00:00

  • Biodistribution and excretion of 125I ioversol in conscious dogs.

    abstract::Radiolabeled ioversol was injected intravenously into two male and two female beagle dogs (6.7 to 10.4 kg) at two dose levels each (0.2 and 1.0 g I/kg). Blood levels of radioactivity were monitored at 2, 5, 10, 20, 40, 60, 90, and 120 minutes and at one and two days. Urine and feces were collected in metabolism cages ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198906001-00005

    authors: Coveney JR,Robbins MS

    更新日期:1989-06-01 00:00:00

  • Assessment of a non-ionic contrast medium (Amipaque) in the gastrointestinal tract.

    abstract::Gastrografin and Amipaque with identical iodine content and flavoring were orally administered in 100 ml doses to 10 healthy volunteers in a double-blind crossover study. The nonionic Amipaque has only about one third of the osmolality of Gastrografin, and draws less fluid into the bowel lumen. Consequently there is l...

    journal_title:Investigative radiology

    pub_type: 临床试验,杂志文章

    doi:10.1097/00004424-197811000-00008

    authors: Johansen JG

    更新日期:1978-11-01 00:00:00

  • Diagnostic performance of dark-blood T2-weighted CMR for evaluation of acute myocardial injury.

    abstract:OBJECTIVES:We compared the image quality and diagnostic performance of 2 fat-suppression methods for black-blood T2-weighted fast spin-echo (FSE), which are as follows: (a) short T1 inversion recovery (STIR; FSE-STIR) and (b) spectral adiabatic inversion recovery (SPAIR; FSE-SPAIR), for detection of acute myocardial in...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e3182718672

    authors: Srichai MB,Lim RP,Lath N,Babb J,Axel L,Kim D

    更新日期:2013-01-01 00:00:00

  • Application of direct cannulation and injection lymphangiography to the study of the canine cardiac and pulmonary efferent mediastinal lymphatics.

    abstract::Lymphangiograms of canine cardiac and pulmonary efferent mediastinal lymphatics were made by cannulation and injection of Ethiodol. Injections were made singly and serially. The mediastinal lymphatics and lymph nodes, which constitute the pathways of drainage of the heart and lungs, were delineated from the point of c...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-197901000-00012

    authors: Leeds SE,Uhley HN,Meister RB

    更新日期:1979-01-01 00:00:00

  • Ultrasound Time-Harmonic Elastography of the Pancreas: Reference Values and Clinical Feasibility.

    abstract:OBJECTIVES:Pancreatic ductal adenocarcinoma (PDAC) is a very aggressive tumor with a very low 5-year survival rate of 8%. The aims of this study are to determine reference values and physiologic confounders in healthy pancreas and to assess the diagnostic accuracy of ultrasound time-harmonic elastography (THE) in the d...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000638

    authors: Burkhardt C,Tzschätzsch H,Schmuck R,Bahra M,Jürgensen C,Pelzer U,Hamm B,Braun J,Sack I,Marticorena Garcia SR

    更新日期:2020-05-01 00:00:00

  • AUR Memorial Award 1993. A drug system (PDH) for interventional radiology. Synthesis, properties, and efficacy.

    abstract:RATIONALE AND OBJECTIVES:The authors synthesized and tested a novel hydrogel system proposed for use in extra- and intravascular radiologic interventions, such as chemoembolizations and embolizations, and as a vehicle for sustained drug release. MATERIALS:The material was specifically designed to meet the prerequisite...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199312000-00001

    authors: Weissleder R,Bogdanov A,Frank H,Nossiff N,Bogdanova A,Schaffer BK,Brady T,Wittenberg J

    更新日期:1993-12-01 00:00:00

  • Reproducibility, accuracy, and predictors of accuracy for the detection of coronary atherosclerotic plaque composition by computed tomography: an ex vivo comparison to intravascular ultrasound.

    abstract:PURPOSE:To determine the reproducibility, accuracy, and predictors of accuracy of computed tomography (CT) angiography to detect and characterize coronary atherosclerotic plaque as compared with intravascular ultrasound. METHODS:Ten ex vivo human coronary arteries were imaged in a moving phantom by dual-source CT (col...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e3181e0a541

    authors: van der Giessen AG,Toepker MH,Donelly PM,Bamberg F,Schlett CL,Raffle C,Irlbeck T,Lee H,van Walsum T,Maurovich-Horvat P,Gijsen FJ,Wentzel JJ,Hoffmann U

    更新日期:2010-11-01 00:00:00