Abstract:
:Thromboembolic complications occurring during angiography may result from a number of different causes. Catheters and guidewires can interact with blood to form thrombi; this tendency is related to wall defects and the chemical composition and structural characteristics of the catheters and guidewires. Nonthrombic sources of emboli may consist of foreign bodies derived from surgical equipment or may exist in the flushing solution and contrast media. Plastic emboli may be shed from catheters and guidewires when the guidewires are passed through the catheters. Air emboli may result from poor technique or loose fitting connections between the catheter and injector or syringe; they can mimic emboli from catheters and guidewires. A number of strategies for decreasing the risk of thromboembolic complications during angiography are reviewed.
journal_name
Invest Radioljournal_title
Investigative radiologyauthors
Kido DK,King PD,Manzione JV,Simon JHdoi
10.1097/00004424-198811002-00009subject
Has Abstractpub_date
1988-11-01 00:00:00pages
S359-65eissn
0020-9996issn
1536-0210journal_volume
23 Suppl 2pub_type
杂志文章,评审abstract::In vivo and in vitro studies have shown that areas of myocardial infarctions can be delineated on CT scans after intravenous administration of iodinated contrast material to dogs with experimental myocardial infarctions. Within the first minute after intravenous administration of contrast material (initial myocardial ...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198011001-00039
更新日期:1980-11-01 00:00:00
abstract::Urine samples were collected from 200 subjects undergoing intravenous pyelography. The urine histamine levels were compared with those of 132 normal control subjects, 11 subjects with systemic mastocytosis, six subjects with idiopathic anaphylaxis, and ten subjects experiencing mild anaphylactic reactions during aller...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198403000-00007
更新日期:1984-03-01 00:00:00
abstract:OBJECTIVES:The objective of this study was to assess the feasibility of the combination of magnetic resonance (MR)-guided biopsy (MRGB) and diagnostic 3T MR imaging in the localization of local recurrence of prostate cancer (PCa) after external beam radiation therapy (EBRT). MATERIALS AND METHODS:Twenty-four consecuti...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0b013e3181c7bcda
更新日期:2010-03-01 00:00:00
abstract:OBJECTIVE:With the introduction of ultrashort echo time (UTE) sequences solid polymeric materials might become visible on clinical whole-body magnetic resonance (MR) scanners. The aim of this study was to characterize solid polymeric materials typically used for instruments in magnetic resonance guided interventions an...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0b013e318188601f
更新日期:2008-11-01 00:00:00
abstract::We have examined the metabolic behavior of several triiodobenzoic acid derivatives because of the observed mutagenicity and cytotoxicity of 3-amino-5-acetamido-2,4,6-triiodobenzoate (I) and 3,5-diamino-2,4,6-triiodobenzoate (II). Measurements were facilitated using iodine-131 (131I)-labeled compounds. Drug retention i...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:
更新日期:1981-11-01 00:00:00
abstract:OBJECTIVE:Computed tomography (CT) and magnetic resonance imaging (MRI) are introduced as an alternative to traditional autopsy. The purpose of this study was to investigate their accuracy in mass estimation of liver and spleen. METHODS:In 44 cases, the weights of spleen and liver were estimated based on MRI and CT da...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/01.rli.0000221323.38443.8d
更新日期:2006-07-01 00:00:00
abstract::Magnetic resonance (MR) methods have been used to study the metabolic and vascular response of model tumors to tumor necrosis factor (TNF). Magnetic resonance measurements demonstrated acute reductions in tumor blood flow, measured from tumor uptake of D2O, and in tumor adenosine triphosphate (ATP), measured by 31P ma...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198912000-00022
更新日期:1989-12-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:Studies describing the effects of radiographic contrast media (RCM) in leukocyte chemotaxis have been contradictory. No studies have been performed after in-vivo exposure. The authors assess the effect of RCM on leukocytes following in-vivo exposure. METHODS:Seventeen patients were studied aft...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199401000-00012
更新日期:1994-01-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:The authors determine the value of contrast-enhanced, three-dimensional (3D) magnetic resonance angiography (MRA) in the assessment of the renal arteries in comparison with conventional arteriography (CA). METHODS:One hundred three patients (71 m, 32 f) were evaluated with both CA and 3D MRA. ...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199809000-00021
更新日期:1998-09-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:The clinically most widely used devices (Porstmann-plug, Rashkind-umbrella, Botallooccluder) have inherent specific limitations (eg, transarterial approach, residual shunts, limited retrieval). The authors assess practicability, efficacy, and tissue reaction of the new retrievable transvenous p...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199709000-00004
更新日期:1997-09-01 00:00:00
abstract::Trypan blue and 197HgCl2 were used as markers of the increased leakage through the blood-brain barrier which developed after selective injection of different contrast media formulations into the internal carotid arteries of rabbits. Interest was focused on a new, experimental, nonionic medium (C-29) and possible effec...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-197907000-00007
更新日期:1979-07-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:Our purpose was to validate contrast-enhanced computed tomography (CECT)-derived quantitative measures of perfusion and permeability against gold standard techniques of fluorescent microspheres and Evan's Blue dye, respectively. MATERIALS AND METHODS:Normal and tumor-bearing (R3230AC) Fischer ...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/01rli.0000124456.82985.35
更新日期:2004-06-01 00:00:00
abstract:OBJECTIVE:Hydration is widely accepted as an effective measure to prevent contrast media (CM)-induced acute kidney injury (AKI). Whether bicarbonate (NaHCO₃) infusion has a greater effect than saline is disputed. Effective prevention of CM-induced AKI by NaHCO₃ has been found by several clinical trials. However, others...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0b013e31822311a9
更新日期:2011-11-01 00:00:00
abstract::This paper presents a microcomputer-based technique that accurately quantifies volumes from computed tomographic (CT) scans of irregularly shaped objects as well as displaying 3-D reconstructions. The method uses standard CT film, allowing analysis of previous or outside CT studies. The planimetry method showed less t...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198812000-00001
更新日期:1988-12-01 00:00:00
abstract::An agent has been identified in lymph from rat kidneys rendered ischemic by partial renal artery occlusion that induces a striking neovascular response in a hamster cheek-pouch assay system. The factor has a high molecular weight, cannot be identified in lymph from normal kidneys, and is associated with a marked incre...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198501000-00015
更新日期:1985-01-01 00:00:00
abstract:OBJECTIVE:To investigate the efficacy of true fast imaging with steady state precession (true-FISP) compared with T2-weighted fast spin echo (T2W-FSE) in monitoring changes in cyst volume and renal expansion in an ischemia reperfusion (IR) injured PKD1 knockout (IKO) mouse model. MATERIALS AND METHODS:The animal study...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0b013e3181be3501
更新日期:2010-01-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:The authors detect activation in the auditory cortex during cochlear electrical stimulation in deaf patients using functional magnetic resonance (MR) imaging. METHODS:Stimulating electrode was inserted gently under local anesthesia close to the round window membrane of the cochlea in seven coc...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199705000-00007
更新日期:1997-05-01 00:00:00
abstract::Fractures modeled in the dried skull indicate that the initial plane of computed tomography (CT) section contributes to the accuracy of three-dimensional (3D) images generated from two-dimensional (2D) CT data. The authors retrospectively analyzed seven clinical cases of tripod zygomatic fractures that were imaged wit...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199105000-00009
更新日期:1991-05-01 00:00:00
abstract::The study aim was to define potential differences and advantages in magnetic resonance (MR) patterns of tumoral contrast enhancement using either a small molecular, extracellular fluid contrast enhancer [Gd-DTPA] or a macromolecular agent [albumin-(Gd-DTPA)20], designed for primary intravascular biodistribution. MR im...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198908000-00007
更新日期:1989-08-01 00:00:00
abstract:INTRODUCTION:The aim of the present study was to evaluate the potential of high-resolution MRI at 2 Tesla (T) for direct noninvasive imaging of the aortic wall in a mouse model of atherosclerosis. MATERIAL AND METHODS:A specific mouse antenna was developed and sequence parameters were adjusted. T(1)- and T2-weighted i...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/01.rli.0000067491.31978.1c
更新日期:2003-08-01 00:00:00
abstract:PURPOSE:To prospectively determine the accuracy of 1.5 Tesla (T) and 3 T magnetic resonance angiography (MRA) versus digital subtraction angiography (DSA) in the depiction of infrageniculate arteries in patients with symptomatic peripheral arterial disease. PATIENTS AND METHODS:A prospective 1.5 T, 3 T MRA, and DSA co...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/01.rli.0000262581.52315.ef
更新日期:2007-06-01 00:00:00
abstract:OBJECTIVE:To investigate the correlation between intravoxel incoherent motion (IVIM) model-derived parameters and histologically determined microvascularity in pancreatic ductal adenocarcinomas (PDACs) and pancreatic neuroendocrine tumors (PNETs). MATERIALS AND METHODS:From April 2013 to May 2014, 42 patients with mal...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0000000000000187
更新日期:2015-11-01 00:00:00
abstract::The cytogenetic interactions of ionic (diatrizoate, ioxaglate) and nonionic (iohexol) contrast media (CM) with antineoplastic drugs cyclophosphamide (CPA) and carmustine (CARM) were evaluated in a rat bone marrow cell model. Male Wistar rats were anesthetized with a 6% chloral hydrate solution and divided into five gr...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198805000-00011
更新日期:1988-05-01 00:00:00
abstract::A method of teaching radiology residents by identification of general and specific objectives to be accomplished during each time segment of the four-year training program has been developed. The objectives are incorporated into an educational contract that is signed by the resident and rotation director at the beginn...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198612000-00009
更新日期:1986-12-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:As part of a general examination of the effect of blood flow patterns on the growth and risk of rupture of abdominal aortic aneurysms, the authors investigated the flow through an experimental model of a fusiform aneurysm. MATERIALS AND METHODS:Aneurysms were simulated in polyvinyl chloride tu...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199207000-00008
更新日期:1992-07-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:To develop a new animal model for the evaluation of the renal tolerance of contrast agent and its application to diatrizoate and iotrolan injections in comparison to saline and mannitol solution. MATERIALS AND METHODS:The nephrotoxic potential of intravenously injected contrast agents in Beagl...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/01.rli.0000087096.61127.13
更新日期:2003-11-01 00:00:00
abstract::The effects of an intravenously administered nitroxyl spin label (PCA) on the magnetic resonance imaging (MRI) appearance and relaxation times of acute canine myocardial infarctions were studied. Twenty-four hours after ligation of the left anterior descending coronary artery (LAD), animals were either sacrificed imme...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:
更新日期:1985-09-01 00:00:00
abstract:OBJECTIVES:The goal of this study was to demonstrate feasibility of measuring extracellular pH in cartilage and meniscus using acidoCEST technique with a 3-dimensional ultrashort echo time readout (acidoCEST-UTE) magnetic resonance imaging (MRI). MATERIALS AND METHODS:Magnetization transfer ratio asymmetry, radiofrequ...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0000000000000576
更新日期:2019-09-01 00:00:00
abstract::Using a 1.5 T magnetic resonance imaging (MRI) system, cine phase-contrast and magnitude images were obtained in three phantoms that simulated different anatomic configurations of aortic dissection. The dissection phantoms were made of compliant materials, and pulsatile flow was used in all experiments. Phantoms diffe...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199112000-00007
更新日期:1991-12-01 00:00:00
abstract:OBJECTIVES:To prospectively evaluate accuracy of biliary anatomy depiction and quality of biliary tract visualization of magnetic resonance cholangiography (MRC) at 3.0 T in living potential liver donors (LPLDs). MATERIALS AND METHODS:Our institutional review board approved this study and did not require patient's inf...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0b013e31817e9b52
更新日期:2008-08-01 00:00:00