Role of iodinated contrast material in the evaluation of myocardial infarction by computerized transmission tomography.

Abstract:

:In vivo and in vitro studies have shown that areas of myocardial infarctions can be delineated on CT scans after intravenous administration of iodinated contrast material to dogs with experimental myocardial infarctions. Within the first minute after intravenous administration of contrast material (initial myocardial perfusion phase), the infarct appears an as area of decreased x-ray attenuation (cold spot image). Studies using radiolabeled microspheres indicate that the relative attenuation numbers throughout the myocardium in this phase reflect myocardial perfusion (Hessel et al, 1978). Delayed scans obtained at 5 minutes and later showed a reversal in the attenuation values of normal and infarcted myocardium with the infarct appearing as an area of homogeneous or mottled increase in x-ray density compared to normal myocardium. (Siemers et al, 1978; Carlsson et al, 1977; Higgins et al, 1979). This phenomenon of delayed contrast enhancement of myocardial infarctions ensues as early as 8 hours after coronary occlusion (Higgins et al, 1979) and is present in evolved infarcts as old as 51 days (Newell et al, 1979). Direct measurements of iodine concentration in infarcts, normal myocardium, and organs surrounding the heart were performed in dogs with 48-hour-old myocardial infarctions using fluorescent excitation analysis (Higgins et al, 1978, 1979). These measurements of iodine concentration in tissue samples obtained at 10-180 minutes after intravenous administration of contrast material indicated that the highest iodine concentration in the infarct was at 10 minutes, but the highest ratio of iodine concentration of the infarct to normal myocardium was at 180 minutes. At all time intervals, the concentration of iodine within the infarct was fivefold greater than in the normal myocardium.

journal_name

Invest Radiol

journal_title

Investigative radiology

authors

Higgins CB,Siemers PT,Newell JD,Schmidt W

doi

10.1097/00004424-198011001-00039

subject

Has Abstract

pub_date

1980-11-01 00:00:00

pages

S176-82

issue

6 Suppl

eissn

0020-9996

issn

1536-0210

journal_volume

15

pub_type

杂志文章
  • Ultrasonic echoes registered from erythrocytes.

    abstract::Erythrocytes at various concentrations were examined with a sensitive A-mode ultrasonic scanner; simultaneous measurements were made under light microscopic control. Individual erythrocytes caused weak (about 1 dB) echoes while erythrocyte aggregates (ten to 100 cells) produced stronger echoes (up to 15 dB), grossly p...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198508000-00014

    authors: Alanen A,Kormano M

    更新日期:1985-08-01 00:00:00

  • First-pass evaluation of myocardial output during dipyridamole stress using turbo-FLASH magnetic resonance imaging.

    abstract:RATIONALE AND OBJECTIVES:This study evaluated the value of dynamically enhanced fast low-angle shot (FLASH) magnetic resonance (MR) imaging in measuring cardiac output with and without dipyridamole pharmacological stress. METHODS:Ten subjects underwent rest and stress MR imaging. Rest images were acquired using electr...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199611000-00003

    authors: Tello R,Hartnell GG,Hill TC,Cerel A,Finn JP,Kamalesh M,Cohen M,Lewis S

    更新日期:1996-11-01 00:00:00

  • Estimating digital information throughput rates for radiology networks. A model.

    abstract::The design and implementation of a digital radiology image management system requires the definition, evaluation, and comparison of appropriate measures of system performance. The mean throughput rate is an important measure of the actual performance of a finished system. The mean throughput rate identifies the transm...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198602000-00014

    authors: Cox GG,Templeton AW,Anderson WH,Cook LT,Hensley KS,Dwyer SJ 3rd

    更新日期:1986-02-01 00:00:00

  • Towards computer analysis of pulmonary infiltration.

    abstract::A feasibility study is described to provide quantitative texture measures to distinguish between normal lung, alveolar infiltrates and interstitial infiltrates. Advanced computer imaging technology and decision making processes were applied to distinguish between these textural patterns. The results, based on computer...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-197807000-00005

    authors: Tully RJ,Conners RW,Harlow CA,Lodwick GS

    更新日期:1978-07-01 00:00:00

  • MRI dosimetry: a fast quantitative MRI method to determine 3D absorbed dose distributions.

    abstract:RATIONALE AND OBJECTIVES:Magnetic resonance imaging (MRI) techniques seem to be very promising for 3D dosimetry studies, but long imaging acquisition time limits their use. A new fast T1 mapping protocol, easy to implement on a conventional MR imager, has been used to determine dose distributions on Fricke gels. METHO...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199903000-00014

    authors: Calmet C,Vincensini D,Bonnet J,Bertino C,Catala A,Martinez M,Joffre F

    更新日期:1999-03-01 00:00:00

  • Antiproliferative effects of the antiallergic agent azelastine on human aortic smooth-muscle cells: an in vitro study.

    abstract:RATIONALE AND OBJECTIVES:The aim of the study was to examine the effects of azelastine on proliferation, clonogenic activity, cell-cycle, and migration of human aortic smooth-muscle cells (haSMCs) in vitro. METHODS:HaSMCs were treated for 4 days with azelastine (1 micromol/L, 25 micromol/L, 50 micromol/L). Half of the...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-200205000-00002

    authors: Schöber W,Wiskirchen J,Kehlbach R,Gebert R,Rodegerdts E,Betsch A,Johst U,Feuls R,Claussen CD,Duda SD

    更新日期:2002-05-01 00:00:00

  • Systemic absorption of gallbladder sclerosing agents in the rabbit. A preliminary study.

    abstract::The absorbed levels of ethanol or tetracycline, used as gallbladder sclerosing agents, were measured in the systemic blood circulation of 16 rabbits. The maximal systemic level of ethanol was 46 mg/dl and of tetracycline was 4.6 micrograms/ml after 30 minutes of gallbladder exposure. Comparable serum levels would be c...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198605000-00005

    authors: Remley KB,Cubberley DA,Watanabe AS,Nelson JA,Colby TV

    更新日期:1986-05-01 00:00:00

  • Preclinical profile of the monodisperse iodinated macromolecular blood pool agent P743.

    abstract:RATIONALE AND OBJECTIVES:To summarize the chemical synthesis, physicochemical characterization, pharmacokinetic behavior, and biological evaluation of P743, a new macromolecular iodinated contrast medium. METHODS:The synthesis and molecular modeling of the iodinated macromolecule P743 are described. The pharmacokineti...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-200101000-00006

    authors: Idée JM,Port M,Robert P,Raynal I,Prigent P,Dencausse A,Le Greneur S,Tichkowsky I,Le Lem G,Bourrinet P,Mugel T,Benderbous S,Devoldere L,Bourbouze R,Meyer D,Bonnemain B,Corot C

    更新日期:2001-01-01 00:00:00

  • Spatial resolution analysis of computed tomographic images.

    abstract::Methods are presented for the quantification of spatial resolution in x-ray computed tomographic (CT) images. Model-dependent methods are derived and compared with model independent methods for computation of the Modulation Transfer Function (MTF). These techniques are applied to phantom images of point, line, edge, a...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198603000-00012

    authors: Assimakopoulos PA,Boyd DP,Jaschke W,Lipton MJ

    更新日期:1986-03-01 00:00:00

  • Photon scattering measurement of calcaneal bone density: result of in vivo cross-sectional studies.

    abstract::The density of trabecular bone in the os calcis has been measured in 321 subjects using a gamma ray scattering technique. In normal subjects it was shown that density could be predicted from body weight and age with a standard error of 5.6%. It was also shown that the dependence of density upon weight and age was the ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198201000-00004

    authors: Roberts JG,DiTomasso E,Webber CE

    更新日期:1982-01-01 00:00:00

  • Computer-aided detection for computed tomographic colonography screening: a prospective comparison of a double-reading paradigm with first-reader computer-aided detection against second-reader computer-aided detection.

    abstract:OBJECTIVES:The objective of this study was to prospectively compare diagnostic performance and time efficiency of a double-reading paradigm in which a first-reader computer-aided detection (CAD) is followed by a fast 2-dimensional review (DR FR-CAD) with those of a double reading with second-reader CAD (SR CAD). MATER...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000009

    authors: Iussich G,Correale L,Senore C,Hassan C,Segnan N,Campanella D,Bert A,Galatola G,Laudi C,Regge D

    更新日期:2014-03-01 00:00:00

  • Comparison of Power Versus Manual Injection in Bolus Shape and Image Quality on Contrast-Enhanced Magnetic Resonance Angiography: An Experimental Study in a Swine Model.

    abstract:OBJECTIVE:The aim of this study was to compare power versus manual injection in bolus shape and image quality on contrast-enhanced magnetic resonance angiography (CE-MRA). MATERIALS AND METHODS:Three types of CE-MRA (head-neck 3-dimensional [3D] MRA with a test-bolus technique, thoracic-abdominal 3D MRA with a bolus-t...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000383

    authors: Tsuboyama T,Jost G,Pietsch H,Tomiyama N

    更新日期:2017-09-01 00:00:00

  • Comparison of Gd(DTPA-BMA) (Omniscan) versus Gd(HP-DO3A) (ProHance) relative to gadolinium retention in human bone tissue by inductively coupled plasma mass spectroscopy.

    abstract:OBJECTIVE:The objective of this study was to determine the gadolinium (Gd) concentration remaining in human bone tissue after administration of standard clinical doses of 2 Gd-based contrast agents: ProHance and Omniscan. MATERIALS AND METHODS:After administration of 0.1 mmol/kg of Gd chelate to patients undergoing hi...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/01.rli.0000186569.32408.95

    authors: White GW,Gibby WA,Tweedle MF

    更新日期:2006-03-01 00:00:00

  • Temporal changes in the oxidation state in in vitro blood.

    abstract::The rates at which the paramagnetic compounds deoxyhemoglobin (Hb) and methemoglobin (MHb) form in vivo within an area of hemorrhage are unknown. The present experiment establishes the baseline concentrations and rates of change in paramagnetic hemoglobin concentrations, as well as the pH in normal heparinized and clo...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199003000-00006

    authors: Taber KH,Migliore PJ,Pagani JJ,Ford JJ,McLauren T,Hayman LA

    更新日期:1990-03-01 00:00:00

  • AUR Memorial Award 1993. A drug system (PDH) for interventional radiology. Synthesis, properties, and efficacy.

    abstract:RATIONALE AND OBJECTIVES:The authors synthesized and tested a novel hydrogel system proposed for use in extra- and intravascular radiologic interventions, such as chemoembolizations and embolizations, and as a vehicle for sustained drug release. MATERIALS:The material was specifically designed to meet the prerequisite...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199312000-00001

    authors: Weissleder R,Bogdanov A,Frank H,Nossiff N,Bogdanova A,Schaffer BK,Brady T,Wittenberg J

    更新日期:1993-12-01 00:00:00

  • The effect of certain variables on the tumor and tissue distribution of tracers: VI. False-carrier effect, Part III, Fe.

    abstract::Previous work has shown that Fe3+, when administered in the proper dose and time sequence, increases the tumor uptake of gallium-67 (67Ga) while decreasing its uptake by normal tissues. The purpose of this series of experiments was to examine further the postulate that the false carrier effect is mediated at the cellu...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198207000-00016

    authors: Stern PH,Halpern SE,Hagan PL,Chen A

    更新日期:1982-07-01 00:00:00

  • Inhibition of restenosis in stented porcine coronary arteries: uptake of Paclitaxel from angiographic contrast media.

    abstract:RATIONALE AND OBJECTIVES:Paclitaxel added to angiographic contrast medium (CM) has been shown to inhibit restenosis in the porcine coronary overstretch model. This study determined early local tissue concentrations after the administration of different paclitaxel doses and preparations. MATERIALS AND METHODS:Fifteen p...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/01.rli.0000116125.96544.64

    authors: Speck U,Scheller B,Abramjuk C,Grossmann S,Mahnkopf D,Simon O

    更新日期:2004-03-01 00:00:00

  • BR1: a new ultrasonographic contrast agent based on sulfur hexafluoride-filled microbubbles.

    abstract:RATIONALE AND OBJECTIVES:The basic characteristics of BR1, a novel echo contrast agent based on stabilized sulfur hexafluoride (SF6) microbubbles have been evaluated. METHODS:The authors determined the physicochemical properties (bubble concentration, bubble size distribution, resistance to pressure, and stability) an...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199508000-00001

    authors: Schneider M,Arditi M,Barrau MB,Brochot J,Broillet A,Ventrone R,Yan F

    更新日期:1995-08-01 00:00:00

  • Effect of inspiratory and expiratory breathhold on pulmonary perfusion: assessment by pulmonary perfusion magnetic resonance imaging.

    abstract:RATIONALE AND OBJECTIVES:The effect of breathholding on pulmonary perfusion remains largely unknown. The aim of this study was to assess the effect of inspiratory and expiratory breathhold on pulmonary perfusion using quantitative pulmonary perfusion magnetic resonance imaging (MRI). METHODS AND RESULTS:Nine healthy v...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/01.rli.0000149252.42679.78

    authors: Fink C,Ley S,Risse F,Eichinger M,Zaporozhan J,Buhmann R,Puderbach M,Plathow C,Kauczor HU

    更新日期:2005-02-01 00:00:00

  • Contrast and electrolyte dynamics of the intravenous pyelogram. II. Disparities in serum and urine concentrations of meglumine and anion.

    abstract::Intravenous or intra-aortic injections of meglumine iothalamate in dogs indicate a slightly different tissue distribution and excretory pattern of the meglumine cation and the iothalamate anion. Differences in serum and urinary concentrations of these ions suggest some cellular penetration of the meglumine anion. In a...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-197507000-00004

    authors: Lasser EC,Lang JH,Hamblin AE,Rosen L

    更新日期:1975-07-01 00:00:00

  • Perfusion quantitation by ultrafast computed tomography.

    abstract::Flow measurements can be made with computed tomography (CT) scanners using iodinated, nonionic contrast media as a first-pass indicator. Ultrafast CT (UFCT) is an ideal machine to make these measurements because of its short scan time (50 mseconds) and interscan delay (< or = 0.6 seconds). Additionally, UFCT can acqui...

    journal_title:Investigative radiology

    pub_type: 杂志文章,评审

    doi:10.1097/00004424-199212002-00004

    authors: Gould RG

    更新日期:1992-12-01 00:00:00

  • Comparison of gadobenate dimeglumine with gadopentetate dimeglumine for magnetic resonance imaging of liver tumors.

    abstract:RATIONALE AND OBJECTIVES:To compare gadobenate dimeglumine (Gd-BOPTA) with gadopentetate dimeglumine (Gd-DTPA) for magnetic resonance imaging of the liver. METHODS:The contrast agent Gd-BOPTA or Gd-DTPA was administered at a dose of 0.1 mmol/kg to 257 patients suspected of having malignant liver tumors. Dynamic phase ...

    journal_title:Investigative radiology

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1097/00004424-200111000-00002

    authors: Kuwatsuru R,Kadoya M,Ohtomo K,Tanimoto A,Hirohashi S,Murakami T,Tanaka Y,Yoshikawa K,Katayama H

    更新日期:2001-11-01 00:00:00

  • Mechanical thrombectomy in hemodialysis access shunts using a 5F pigtail rotation catheter. In vitro and in vivo investigations.

    abstract:RATIONALE AND OBJECTIVES:To evaluate the feasibility of mechanical thrombectomy in occluded hemodialysis access shunts by using a newly developed 5F pigtail rotation catheter. METHODS:Thrombosed hemodialysis access shunts were simulated by clotted bovine blood in silicone tubing (diameter 6 mm). After retrograde and a...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199907000-00008

    authors: Wildberger J,Schmitz-Rode T,Wein BB,Günther RW

    更新日期:1999-07-01 00:00:00

  • Alteration of human tumor cell adhesion by high-strength static magnetic fields.

    abstract:RATIONALE AND OBJECTIVES:The authors investigated whether the ability of human malignant melanoma cells to increase in cell number or their ability to remain viable was compromised by high-field strength static magnetic fields. Normal human fibroblasts also were studied to determine if any magnetic field-related altera...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199210000-00014

    authors: Short WO,Goodwill L,Taylor CW,Job C,Arthur ME,Cress AE

    更新日期:1992-10-01 00:00:00

  • Slice simulation from a model of the parenchymous vascularization to evaluate texture features: work in progress.

    abstract:RATIONALE AND OBJECTIVES:To demonstrate the usefulness of a model of the parenchymous vascularization to evaluate texture analysis methods. METHODS:Slices with thickness varying from 1 to 4 mm were reformatted from a 3D vascular model corresponding to either normal tissue perfusion or local hypervascularization. Param...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199903000-00004

    authors: Rolland Y,Bézy-Wendling J,Duvauferrier R,Coatrieux JL

    更新日期:1999-03-01 00:00:00

  • Evaluation of diffusion-weighted MR imaging at inclusion in an active surveillance protocol for low-risk prostate cancer.

    abstract:PURPOSE:We aimed to determine whether diffusion-weighted magnetic resonance imaging, by means of the apparent diffusion coefficient (ADC), is able to guide magnetic resonance-guided biopsy in patients fit for active surveillance (AS) and identify patients harboring high-grade Gleason components not suitable for AS. MA...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e31827b711e

    authors: Somford DM,Hoeks CM,Hulsbergen-van de Kaa CA,Hambrock T,Fütterer JJ,Witjes JA,Bangma CH,Vergunst H,Smits GA,Oddens JR,van Oort IM,Barentsz JO,MR-PRIAS Collaboration Group.

    更新日期:2013-03-01 00:00:00

  • Observation on the metabolism of iopanoyl (Telepaque) glucuronide in dogs treated with antibiotics.

    abstract::The purpose of our investigation was to determine whether iopanoyl glucuronide, the major metabolite of iopanoic acid (Telepaque), undergoes hydrolysis by bacterial beta-glucuronidase in dogs. The conjugated compound was identified and quantitated by elemental analysis, fluorescent excitation analysis, thin-layer chro...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-197805000-00011

    authors: Thoeni RF,Goldberg HI,Moss AA,Lin SK,Brito AC

    更新日期:1978-05-01 00:00:00

  • Auditory cortex activation in deaf subjects during cochlear electrical stimulation. Evaluation by functional magnetic resonance imaging.

    abstract:RATIONALE AND OBJECTIVES:The authors detect activation in the auditory cortex during cochlear electrical stimulation in deaf patients using functional magnetic resonance (MR) imaging. METHODS:Stimulating electrode was inserted gently under local anesthesia close to the round window membrane of the cochlea in seven coc...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199705000-00007

    authors: Berthezène Y,Truy E,Morgon A,Giard MH,Hermier M,Franconi JM,Froment JC

    更新日期:1997-05-01 00:00:00

  • Pyrroxamide, a nonionic nitroxyl spin label contrast agent for magnetic resonance imaging. Mutagenesis and cell survival.

    abstract::Pyrroxamide [N-(1-hydroxymethyl-2,3-dihydroxypropyl)-2,2,5,5-tetramethyl pyrrolidine-1-oxyl-3-carboxyamide] is a newly tested nonionic monomeric nitroxyl compound with demonstrated effectiveness for MRI contrast enhancement at doses as low as 10(-3) M. Pyrroxamide and its hydroxylamine metabolic derivative were tested...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198808000-00013

    authors: Gordon DG,Brasch RC,Ogan MD,Deen D

    更新日期:1988-08-01 00:00:00

  • Toward clinical X-ray phase-contrast CT: demonstration of enhanced soft-tissue contrast in human specimen.

    abstract:OBJECTIVES:X-ray computed tomography (CT) using phase contrast can provide images with greatly enhanced soft-tissue contrast in comparison to conventional attenuation-based CT. We report on the first scan of a human specimen recorded with a phase-contrast CT system based on an x-ray grating interferometer and a convent...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e3181e21866

    authors: Donath T,Pfeiffer F,Bunk O,Grünzweig C,Hempel E,Popescu S,Vock P,David C

    更新日期:2010-07-01 00:00:00