High-resolution magnetic resonance imaging at 2 Tesla: potential for atherosclerotic lesions exploration in the apolipoprotein E knockout mouse.

Abstract:

INTRODUCTION:The aim of the present study was to evaluate the potential of high-resolution MRI at 2 Tesla (T) for direct noninvasive imaging of the aortic wall in a mouse model of atherosclerosis. MATERIAL AND METHODS:A specific mouse antenna was developed and sequence parameters were adjusted. T(1)- and T2-weighted images of abdominal aorta were obtained at 2 T with a spatial resolution of 86 x 86 x 800 microm3 in vivo. With a dedicated small coil, ex vivo MRI of the aorta was performed with a spatial resolution of 54 x 54 x 520 microm3. RESULTS:In vivo, the aortic wall was clearly defined on T(2)-weighted images in 15 of 16 mice: along the aorta the lumen circumference ranged from 1.07 to 3.61 mm and mean wall thickness from 0.11 to 0.67 mm. In vivo measurements of plaque distribution were confirmed by ex vivo MR imaging and by histology, with a good correlation with histology regarding lumen circumference (r = 0.94) and wall thickness (r = 0.97). CONCLUSION:Magnetic resonance imaging at 2 T to analyze in vivo atherosclerotic lesions in mice is possible with a spatial resolution of 86 x 86 x 800 microm3 and thus can be used for noninvasive follow-up in evaluation of new drugs.

journal_name

Invest Radiol

journal_title

Investigative radiology

authors

Chaabane L,Soulas EC,Contard F,Salah A,Guerrier D,Briguet A,Douek P

doi

10.1097/01.rli.0000067491.31978.1c

keywords:

subject

Has Abstract

pub_date

2003-08-01 00:00:00

pages

532-8

issue

8

eissn

0020-9996

issn

1536-0210

journal_volume

38

pub_type

杂志文章
  • Radiologic-pathologic-clinical correlation in mechanisms of disease course.

    abstract::The interdisciplinary approach to medical education has often been deficient in medical school curricula. Because of the nonintegrated approach to medical education, problem solving capabilities are not fostered. The clinical presentation of a patient, the imaging modalities used to investigate the patient, and the ul...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198604000-00015

    authors: Oldham SA,Jacobson F

    更新日期:1986-04-01 00:00:00

  • Effects of iodinated x-ray contrast media on renal epithelial cells in culture.

    abstract:RATIONALE AND OBJECTIVES:To study cellular mechanisms that cause contrast media nephropathy, an in vitro system for proximal and distal tubular cells has been established to evaluate the influence of x-ray contrast media on tubular function. METHODS:Confluent cell cultures of the two renal cell lines, proximal tubule ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199411000-00002

    authors: Andersen KJ,Christensen EI,Vik H

    更新日期:1994-11-01 00:00:00

  • Phlebography. Survey and present state.

    abstract::Milestones in the history of phlebography are shortly reviewed. The present state of phlebography with emphasis upon the role of new nonionic contrast media is presented. ...

    journal_title:Investigative radiology

    pub_type: 临床试验,杂志文章

    doi:

    authors: Enge I

    更新日期:1985-01-01 00:00:00

  • Noninvasive measurement of an index of renal blood flow.

    abstract::A new technique for the noninvasive measurement of an index of renal blood flow is described. The method utilizes ultrasound determined renal volume and radionuclide assessment of the mean transit time of a pertechnetate bolus through the kidneys. From this information a value for flow is calculated according to compa...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198307000-00009

    authors: Powers TA,Rees RS,Bowen RD

    更新日期:1983-07-01 00:00:00

  • The etiology and implications of dense cavitary "photopenia" on myocardial perfusion scintigraphy.

    abstract::Dense cavitary "photopenia" was observed on 21 of 200 consecutive stress perfusion scintigrams. A prominent finding in many cases, it sometimes occupied only a portion of the region overlying the ventricular cavity, was often seen in some projections and not others, and was frequently adjacent to myocardial perfusion ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198507000-00009

    authors: Dae M,Canhasi B,Botvinick E,Olvera S,Schechtmann N,Engelstad B,Hattner R,Schiller N,O'Connell W,Faulkner D

    更新日期:1985-07-01 00:00:00

  • Large-tip-angle spin-echo imaging. Theory and applications.

    abstract:RATIONALE AND OBJECTIVES:Tissue contrast phenomenology was investigated analytically and clinically for a class of magnetic resonance (MR) pulse sequences we call large-tip-angle (LTA) spin-echo (SE) imaging. In comparison to traditional SE sequences (denoted 90 degrees-180 degrees-echo), the LTA sequence is of the for...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199310000-00017

    authors: Elster AD,Provost TJ

    更新日期:1993-10-01 00:00:00

  • Trabecular bone structure of the distal radius, the calcaneus, and the spine: which site predicts fracture status of the spine best?

    abstract:RATIONALE AND OBJECTIVES:To compare trabecular bone structure measures obtained in magnetic resonance images of the distal radius and the calcaneus as well as computed tomographic images of the spine versus bone mineral density (BMD) of the spine and the calcaneus in the prediction of osteoporotic spine fracture status...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/01.rli.0000129154.50654.4e

    authors: Link TM,Bauer J,Kollstedt A,Stumpf I,Hudelmaier M,Settles M,Majumdar S,Lochmüller EM,Eckstein F

    更新日期:2004-08-01 00:00:00

  • Experimental tissue damage after subcutaneous injection of water soluble contrast media.

    abstract::Various water soluble contrast media (WSCM) were injected subcutaneously into 970 hind feet of 485 rats. Gross morphologic changes were seen after the injection and analyzed as a function of various physicochemical characteristics of WSCM. The WSCM of larger volume, higher osmolality, higher iodine content, and meglum...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199006000-00011

    authors: Kim SH,Park JH,Kim YI,Kim CW,Han MC

    更新日期:1990-06-01 00:00:00

  • Pharmacokinetics and safety of gadobutrol-enhanced magnetic resonance imaging in pediatric patients.

    abstract:OBJECTIVES:This clinical study investigated the pharmacokinetics and safety of gadobutrol, a magnetic resonance (MR) imaging extracellular contrast agent, in pediatric patients aged 2 to 17 years. MATERIALS AND METHODS:In this open-label, multicenter study, patients scheduled for routine contrast-enhanced MR imaging o...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e3181bfe2d2

    authors: Hahn G,Sorge I,Gruhn B,Glutig K,Hirsch W,Bhargava R,Furtner J,Born M,Schröder C,Ahlström H,Kaiser S,Moritz JD,Kunze CW,Shroff M,Stokland E,Trnkova ZJ,Schultze-Mosgau M,Reif S,Bacher-Stier C,Mentzel HJ

    更新日期:2009-12-01 00:00:00

  • Detection of breast abnormalities on teleradiology transmitted mammograms.

    abstract::The authors conducted an observer performance study to compare breast lesion detection of conventional mammography (CM) with teleradiology (TE) transmitted mammograms. One hundred four abnormal, single-projection mammographic images were transmitted by teleradiology. Abnormalities included 11 cases with skin thickenin...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199010000-00007

    authors: Fajardo LL,Yoshino MT,Seeley GW,Hunt R,Hunter TB,Friedman R,Cardenas D,Boyle R

    更新日期:1990-10-01 00:00:00

  • Digital radiography versus conventional radiography for the detection of a skull fracture under varying exposure parameters.

    abstract:RATIONALE AND OBJECTIVES:The effect of varying exposure parameters on the detectability of a fracture with digital and conventional radiography were examined. METHODS:A macerated fractured skull was imaged by film-screen radiography (FSR) and digital storage phosphor radiography (DR) with various exposure values. Five...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199303000-00010

    authors: Langen HJ,Klein HM,Wein B,Schiwy-Bochat KH,Stargardt A,Günther RW

    更新日期:1993-03-01 00:00:00

  • Technical feasibility and performance studies of a 0.009-inch nitinol microguidewire for potential neuroendovascular applications.

    abstract:RATIONALE AND OBJECTIVES:The authors conduct technical feasibility and performance studies on a new 0.009-inch nitinol microguidewire for potential neuroendovascular applications. METHODS:In vivo microcatheterizations of brachiocephalic arteries were performed in four pigs using the 0.009-inch nitinol microguidewire w...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199704000-00008

    authors: Putman CM,Chaloupka JC,Kailasnath P,Alderman J

    更新日期:1997-04-01 00:00:00

  • Incidence and methods of diagnosis of musculoskeletal injuries incurred in Operations Desert Shield and Desert Storm.

    abstract:RATIONALE AND OBJECTIVES:The authors studied the incidence and distribution of orthopedic injuries sustained in Operation Desert Shield and Desert Storm by evaluating whether existing diagnostic imaging modalities were sufficient to diagnose the types of musculoskeletal injuries incurred. The authors also sought to det...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199703000-00006

    authors: Truax AL,Chandnani VP,Chacko AK,Gonzalez DM

    更新日期:1997-03-01 00:00:00

  • The effects of radiographic contrast media on myocardial contractility and coronary resistance: osmolality, ionic concentration, and viscosity.

    abstract::With the ongoing development of new contrast agents, questions develop concerning the cardiac effects of these drugs. We used the perfused rat heart model to investigate the effects on cardiac and coronary function of hypertonic ionic (sodium chloride) and nonionic (glucose) solutions and conventional and low osmolali...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199003000-00009

    authors: Fleetwood G,Bettmann MA,Gordon JL

    更新日期:1990-03-01 00:00:00

  • Retrievable patent ductus arteriosus plug for interventional, transvenous occlusion of the patent ductus arteriosus. Evaluation in lambs and preliminary clinical results.

    abstract:RATIONALE AND OBJECTIVES:The clinically most widely used devices (Porstmann-plug, Rashkind-umbrella, Botallooccluder) have inherent specific limitations (eg, transarterial approach, residual shunts, limited retrieval). The authors assess practicability, efficacy, and tissue reaction of the new retrievable transvenous p...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199709000-00004

    authors: Grabitz RG,Schräder R,Sigler M,Seghaye MC,Dzionsko C,Handt S,Schneidt B,Von Bernuth G

    更新日期:1997-09-01 00:00:00

  • Cellular uptake and trafficking of a prototypical magnetic iron oxide label in vitro.

    abstract:RATIONALE AND OBJECTIVES:Target-specific magnetic resonance (MR) contrast agents are being developed to improve the accuracy of MR imaging. The purpose of this study was to determine the mechanism of cell uptake, and modes of intracellular trafficking of a prototypical iron oxide label (RMA) used in the synthesis of so...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199510000-00006

    authors: Schulze E,Ferrucci JT Jr,Poss K,Lapointe L,Bogdanova A,Weissleder R

    更新日期:1995-10-01 00:00:00

  • Critical Questions Regarding Gadolinium Deposition in the Brain and Body After Injections of the Gadolinium-Based Contrast Agents, Safety, and Clinical Recommendations in Consideration of the EMA's Pharmacovigilance and Risk Assessment Committee Recommend

    abstract::For magnetic resonance, the established class of intravenous contrast media is the gadolinium-based contrast agents. In the 3 decades since initial approval, these have proven in general to be very safe for human administration. However, in 2006, a devastating late adverse reaction to administration of the less stable...

    journal_title:Investigative radiology

    pub_type: 杂志文章,评审

    doi:10.1097/RLI.0000000000000374

    authors: Runge VM

    更新日期:2017-06-01 00:00:00

  • Auditory cortex activation in deaf subjects during cochlear electrical stimulation. Evaluation by functional magnetic resonance imaging.

    abstract:RATIONALE AND OBJECTIVES:The authors detect activation in the auditory cortex during cochlear electrical stimulation in deaf patients using functional magnetic resonance (MR) imaging. METHODS:Stimulating electrode was inserted gently under local anesthesia close to the round window membrane of the cochlea in seven coc...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199705000-00007

    authors: Berthezène Y,Truy E,Morgon A,Giard MH,Hermier M,Franconi JM,Froment JC

    更新日期:1997-05-01 00:00:00

  • Diffusivity- and T2 imaging at 3 Tesla for the detection of degenerative changes in human-excised tissue with high resolution: atherosclerotic arteries.

    abstract:RATIONALE AND OBJECTIVES:We investigated whether it is possible to investigate degenerative changes in human tissue on a sub-100-microm resolution scale not only on special high-field small-bore MR-microscopy systems but also on a 3T whole-body MR-scanner. METHODS:Spin-spin relaxation, proton density, and diffusion mi...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/01.RLI.0000068620.17569.83

    authors: Berg A,Sailer J,Rand T,Moser E

    更新日期:2003-07-01 00:00:00

  • Brain tumor enhancement in magnetic resonance imaging: dependency on the level of protein binding of applied contrast agents.

    abstract:PURPOSE:To evaluate the dependency of tumor contrast enhancement (CE) in regard to protein-binding properties of contrast agents, using 4 different agents with a wide range of protein-binding capacities in a standardized rat brain glioma model. MATERIAL AND METHODS:Sixteen rats with implanted brain gliomas were evalua...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e318191a334

    authors: Wintersperger BJ,Runge VM,Tweedle MF,Jackson CB,Reiser MF

    更新日期:2009-02-01 00:00:00

  • Hepatic kinetics and magnetic resonance imaging of gadolinium-EOB-DTPA in dogs.

    abstract:RATIONALE AND OBJECTIVES:To measure the hepatic uptake and biliary elimination kinetics of gadolinium (Gd)-EOB-DTPA in dogs. METHOD:Two groups of four beagles each were anesthetized and given an intravenous bolus of 25 mumol/kg or 250 mumol/kg of Gd-EOB-DTPA. Blood, hepatic bile, and urine were collected over 140 minu...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199604000-00005

    authors: Benness G,Khangure M,Morris I,Warwick A,Burrows P,Vogler H,Weinmann HJ

    更新日期:1996-04-01 00:00:00

  • Embolization of superior mesenteric artery branches in dogs. Ischemic bowel changes depend on location of vessel occlusion and embolic materials.

    abstract:OBJECTIVE:To evaluate the degree of ischemic changes of the small intestine after arterial embolization of proximal or distal arteries with Gelfoam particles and coils in dogs. METHODS:Superselective arterial embolization in 18 dogs was performed using a coaxial catheter system. Gelfoam occlusion of the proximal level...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199910000-00004

    authors: Han YM,Lee JM,Jin KY,Lee SY,Kim CS

    更新日期:1999-10-01 00:00:00

  • 3.0 Tesla high spatial resolution contrast-enhanced magnetic resonance angiography (CE-MRA) of the pulmonary circulation: initial experience with a 32-channel phased array coil using a high relaxivity contrast agent.

    abstract:PURPOSE:To evaluate the technical feasibility of high spatial resolution contrast-enhanced magnetic resonance angiography (CE-MRA) with highly accelerated parallel acquisition at 3.0 T using a 32-channel phased array coil, and a high relaxivity contrast agent. MATERIALS AND METHODS:Ten adult healthy volunteers (5 men,...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/01.rli.0000261937.77365.6a

    authors: Nael K,Fenchel M,Krishnam M,Finn JP,Laub G,Ruehm SG

    更新日期:2007-06-01 00:00:00

  • Comparison of gadobenate dimeglumine with gadopentetate dimeglumine for magnetic resonance imaging of liver tumors.

    abstract:RATIONALE AND OBJECTIVES:To compare gadobenate dimeglumine (Gd-BOPTA) with gadopentetate dimeglumine (Gd-DTPA) for magnetic resonance imaging of the liver. METHODS:The contrast agent Gd-BOPTA or Gd-DTPA was administered at a dose of 0.1 mmol/kg to 257 patients suspected of having malignant liver tumors. Dynamic phase ...

    journal_title:Investigative radiology

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1097/00004424-200111000-00002

    authors: Kuwatsuru R,Kadoya M,Ohtomo K,Tanimoto A,Hirohashi S,Murakami T,Tanaka Y,Yoshikawa K,Katayama H

    更新日期:2001-11-01 00:00:00

  • Opacification phase effects of angiographic contrast medium on left ventricular size and function: influence of initial ventricular volume and the pericardium.

    abstract::Prior studies of the opacification-phase effects of left ventricular (LV) injection of angiographic contrast medium (CM) on LV size and function have yielded discrepant results. A sensitive ultrasonic technique was used to measure LV dimension (Di) in 10 open-chest dogs with physiologic heart rates, and injection of s...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198209000-00009

    authors: LeWinter MM,Pavelec RS

    更新日期:1982-09-01 00:00:00

  • Evaluation of CT time-density curves of lower-limb veins.

    abstract:UNLABELLED:Szapiro D, Ghaye B, Willems V, et al. Evaluation of CT time-density curves of lower-limb veins. Invest Radiol 2001;36:164-169. RATIONALE AND OBJECTIVES:To evaluate time-density curves of the lower-limb veins for optimization of CT venography. METHODS:Fifty patients referred for chest CT were randomized int...

    journal_title:Investigative radiology

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1097/00004424-200103000-00005

    authors: Szapiro D,Ghaye B,Willems V,Zhang L,Albert A,Dondelinger RF

    更新日期:2001-03-01 00:00:00

  • A Single-Arm, Multicenter Validation Study of Prostate Cancer Localization and Aggressiveness With a Quantitative Multiparametric Magnetic Resonance Imaging Approach.

    abstract:OBJECTIVES:The aims of this study were to assess the discriminative performance of quantitative multiparametric magnetic resonance imaging (mpMRI) between prostate cancer and noncancer tissues and between tumor grade groups (GGs) in a multicenter, single-vendor study, and to investigate to what extent site-specific dif...

    journal_title:Investigative radiology

    pub_type: 杂志文章,多中心研究

    doi:10.1097/RLI.0000000000000558

    authors: Maas MC,Litjens GJS,Wright AJ,Attenberger UI,Haider MA,Helbich TH,Kiefer B,Macura KJ,Margolis DJA,Padhani AR,Selnæs KM,Villeirs GM,Fütterer JJ,Scheenen TWJ

    更新日期:2019-07-01 00:00:00

  • A closed-chest pulmonary artery occlusion/reperfusion model in the pig: detection of experimental pulmonary embolism with MR angiography and perfusion MR imaging.

    abstract:RATIONALE AND OBJECTIVES:To establish a pig model suitable for imitating pulmonary emboli to facilitate research in the diagnosis of pulmonary embolism. METHODS:Thirteen animals were anesthetized, mechanically ventilated, and subjected to pulmonary artery catheterization initiated from the right external jugular vein....

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-200005000-00003

    authors: Amundsen T,Kvaerness J,Aadahl P,Waage A,Bjermer L,Odegård A,Haraldseth O

    更新日期:2000-05-01 00:00:00

  • Perfusion quantitation by ultrafast computed tomography.

    abstract::Flow measurements can be made with computed tomography (CT) scanners using iodinated, nonionic contrast media as a first-pass indicator. Ultrafast CT (UFCT) is an ideal machine to make these measurements because of its short scan time (50 mseconds) and interscan delay (< or = 0.6 seconds). Additionally, UFCT can acqui...

    journal_title:Investigative radiology

    pub_type: 杂志文章,评审

    doi:10.1097/00004424-199212002-00004

    authors: Gould RG

    更新日期:1992-12-01 00:00:00

  • Experimental carotid aneurysms: I. Simple surgical production and radiographic evaluation.

    abstract::Using simple surgical techniques, experimental carotid aneurysms are created which simulate some types of human berry aneurysms, both in hemodynamic and radiographic behavior. End to side anastomoses of an external jugular vein graft to the common carotid artery can be carried out by radiologic personnel with no forma...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-197703000-00009