Diagnostic performance of dark-blood T2-weighted CMR for evaluation of acute myocardial injury.

Abstract:

OBJECTIVES:We compared the image quality and diagnostic performance of 2 fat-suppression methods for black-blood T2-weighted fast spin-echo (FSE), which are as follows: (a) short T1 inversion recovery (STIR; FSE-STIR) and (b) spectral adiabatic inversion recovery (SPAIR; FSE-SPAIR), for detection of acute myocardial injury. BACKGROUND:Edema-sensitive T2-weighted FSE cardiac magnetic resonance (CMR) imaging is useful in detecting acute myocardial injury but may experience reduced myocardial signal and signal dropout. The SPAIR pulse aims to eliminate artifacts associated with the STIR pulse. MATERIALS AND METHODS:A total of 65 consecutive patients referred for CMR evaluation of myocardial structure and function underwent FSE-STIR and FSE-SPAIR, in addition to cine and late gadolinium enhancement (LGE) CMR. T2-weighted FSE images were independently evaluated by 2 readers for image quality and artifacts (Likert scale of 1-5; best-worst) and presence of increased myocardial signal suggestive of edema. In addition, clinical CMR interpretation, incorporating all CMR sequences available, was recorded for comparison. Diagnostic performance of each T2-weighted sequence was measured using recent (<30 days) troponin elevation greater than 2 times the upper limit of normal as the reference standard for acute myocardial injury. RESULTS:Of the 65 patients, there were 21 (32%) with acute myocardial injury. Image quality and artifact scores were significantly better with FSE-SPAIR compared with FSE-STIR (2.15 vs 2.68, P < 0.01; 2.62 vs 3.05, P < 0.01, respectively). The sensitivity, specificity, positive predictive value, and negative predictive value for acute myocardial injury were as follows: 29%, 93%, 67%, and 73% for FSE-SPAIR; 38%, 91%, 67%, and 75% for FSE-STIR; 71%, 98%, 94%, and 88% for clinical interpretation including LGE, T2, and wall motion. There was a statistically significant difference in sensitivity between the clinical interpretation and each of the T2-weighted sequences but not between each T2-weighted sequence. CONCLUSIONS:Although FSE-SPAIR demonstrated significantly improved image quality and decreased artifacts, isolated interpretations of each T2-weighted technique demonstrated high specificity but overall low sensitivity for the detection of myocardial injury, with no difference in accuracy between the techniques. However, real-world interpretation in combination with cine and LGE CMR methods significantly improves the overall sensitivity and diagnostic performance.

journal_name

Invest Radiol

journal_title

Investigative radiology

authors

Srichai MB,Lim RP,Lath N,Babb J,Axel L,Kim D

doi

10.1097/RLI.0b013e3182718672

subject

Has Abstract

pub_date

2013-01-01 00:00:00

pages

24-31

issue

1

eissn

0020-9996

issn

1536-0210

journal_volume

48

pub_type

杂志文章
  • Free-breathing three-dimensional computed tomography of the lung using prospective respiratory gating: charge-coupled device camera and laser sensor device in an animal experiment.

    abstract:PURPOSE:The aim was to investigate the feasibility and image quality of prospective respiratory gating for 3-D computed tomography (CT) of the lung. MATERIAL AND METHODS:Eight anesthetized pigs underwent prospectively gated multidetector computed tomography using 2 devices: a charge-coupled device (CCD) camera and a l...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/01.rli.0000208926.98693.b6

    authors: Zaporozhan J,Ley S,Unterhinninghofen R,Saito Y,Fabel-Schulte M,Keller S,Szabo G,Kauczor HU

    更新日期:2006-05-01 00:00:00

  • Assessment of osteosarcoma response to preoperative chemotherapy using dynamic FLASH gadolinium-DTPA-enhanced magnetic resonance mapping.

    abstract:RATIONALE AND OBJECTIVES:To improve the accuracy of magnetic resonance imaging (MRI) in evaluating the response of osteosarcomas to preoperative chemotherapy, the authors developed a technique of mapping tumor necrosis and viability by quantitating slope values of gadolinium-DTPA (Gd-DTPA) uptake on dynamic fast low-an...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199205000-00010

    authors: Hanna SL,Parham DM,Fairclough DL,Meyer WH,Le AH,Fletcher BD

    更新日期:1992-05-01 00:00:00

  • Granulocyte accumulation in the transplanted liver does not correlate with clinical and histologic evidence of dysfunction.

    abstract:RATIONALE AND OBJECTIVES:To evaluate the role of granulocytes in reperfusion injury after liver transplantation. The authors injected radiolabeled granulocytes to determine if human liver graft outcome could be correlated with granulocyte accumulation. MATERIALS AND METHODS:Pure granulocyte suspension was prepared fro...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199603000-00003

    authors: Ziser A,Forstrom LA,Plevak DJ,Sanchez-Urdazpal L,Gores GJ,Wiesner RH,Batts KP,Krom RA

    更新日期:1996-03-01 00:00:00

  • A new class of contrast agents for magnetic resonance imaging based on selective reduction of water-T2 by chemical exchange.

    abstract::Compounds containing mobile protons can act as contrast agents by increasing the value of the term (1/12 - 1/11). The efficiency of this method is markedly pH- and field-dependent. There are many such compounds allowing a choice to be made based on the characteristics of the tissue or organ, magnetic field strength, a...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198809001-00058

    authors: Aime S,Nano R,Grandi M

    更新日期:1988-09-01 00:00:00

  • Temporal changes in the oxidation state in in vitro blood.

    abstract::The rates at which the paramagnetic compounds deoxyhemoglobin (Hb) and methemoglobin (MHb) form in vivo within an area of hemorrhage are unknown. The present experiment establishes the baseline concentrations and rates of change in paramagnetic hemoglobin concentrations, as well as the pH in normal heparinized and clo...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199003000-00006

    authors: Taber KH,Migliore PJ,Pagani JJ,Ford JJ,McLauren T,Hayman LA

    更新日期:1990-03-01 00:00:00

  • Cellular uptake and trafficking of a prototypical magnetic iron oxide label in vitro.

    abstract:RATIONALE AND OBJECTIVES:Target-specific magnetic resonance (MR) contrast agents are being developed to improve the accuracy of MR imaging. The purpose of this study was to determine the mechanism of cell uptake, and modes of intracellular trafficking of a prototypical iron oxide label (RMA) used in the synthesis of so...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199510000-00006

    authors: Schulze E,Ferrucci JT Jr,Poss K,Lapointe L,Bogdanova A,Weissleder R

    更新日期:1995-10-01 00:00:00

  • Contrast-enhanced magnetic resonance angiography in rabbits: evaluation of the gadolinium-based agent p846 and the iron-based blood pool agent p904 in comparison with gadoterate meglumine.

    abstract:OBJECTIVES:: To evaluate the performance of a gadolinium-based contrast compound (P846) as well as an ultra-small particle of iron oxide agent (P904) in contrast-enhanced magnetic resonance angiography (MRA) in rabbits and to compare those agents with gadoterate meglumine (Gd-DOTA) for first pass and steady state imagi...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e31821ae21f

    authors: Kinner S,Maderwald S,Parohl N,Albert J,Corot C,Robert P,Barkhausen J,Vogt FM

    更新日期:2011-08-01 00:00:00

  • Evaluation of perfluoroctylbromide for lymphography in the dog: comparison with ethiodol.

    abstract::The efficacy and safety of perfluoroctylbromide as a diagnostic contrast agent for direct lymphography was studied in mongrel dogs. This radiopaque perfluorocarbon has several advantages over Ethiodol. The liquid compound has injection times one-fifth of that required for Ethiodol. When dosages were three to four tim...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-197707000-00012

    authors: Liebner EJ

    更新日期:1977-07-01 00:00:00

  • Impact of Impaired Renal Function on Gadolinium Retention After Administration of Gadolinium-Based Contrast Agents in a Mouse Model.

    abstract:OBJECTIVES:The aim of this study was to investigate the impact of impaired renal function on gadolinium (Gd) retention in various organs after Gd-based contrast agent injection. MATERIALS AND METHODS:After local animal care and review committee approval, 23 normal mice and 26 with renal failure were divided into 4 tre...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000295

    authors: Kartamihardja AA,Nakajima T,Kameo S,Koyama H,Tsushima Y

    更新日期:2016-10-01 00:00:00

  • Detection and characterization of focal liver lesions: a Japanese phase III, multicenter comparison between gadoxetic acid disodium-enhanced magnetic resonance imaging and contrast-enhanced computed tomography predominantly in patients with hepatocellular

    abstract:OBJECTIVES:To prospectively evaluate the safety and efficacy of combined unenhanced and gadoxetic acid disodium (Gd-EOB-DTPA)-enhanced magnetic resonance (MR) imaging compared with unenhanced MR imaging and triphasic contrast-enhanced spiral computed tomography (CT) for the detection and characterization of focal liver...

    journal_title:Investigative radiology

    pub_type: 杂志文章,多中心研究

    doi:10.1097/RLI.0b013e3181caea5b

    authors: Ichikawa T,Saito K,Yoshioka N,Tanimoto A,Gokan T,Takehara Y,Kamura T,Gabata T,Murakami T,Ito K,Hirohashi S,Nishie A,Saito Y,Onaya H,Kuwatsuru R,Morimoto A,Ueda K,Kurauchi M,Breuer J

    更新日期:2010-03-01 00:00:00

  • Black-blood diffusion-weighted EPI acquisition of the liver with parallel imaging: comparison with a standard T2-weighted sequence for detection of focal liver lesions.

    abstract:OBJECTIVES:To evaluate the performance of black-blood diffusion-weighted (DW)-EPI sequences with parallel imaging for the detection of focal liver lesions in comparison with a standard T2-weighted (T2-w) sequence. MATERIALS AND METHODS:Twenty patients with known or suspected focal liver lesions underwent liver MRI usi...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e31816200b5

    authors: Zech CJ,Herrmann KA,Dietrich O,Horger W,Reiser MF,Schoenberg SO

    更新日期:2008-04-01 00:00:00

  • Phase I clinical evaluation of citrate-coated monocrystalline very small superparamagnetic iron oxide particles as a new contrast medium for magnetic resonance imaging.

    abstract:RATIONALE AND OBJECTIVES:To evaluate the safety and pharmacokinetics of a newly developed MR contrast medium consisting of very small superparamagnetic iron oxide particles (VSOP) coated with citrate (VSOP-C184) in a clinical phase I trial. METHODS:A total of 18 healthy subjects received either VSOP-C184 (core diamete...

    journal_title:Investigative radiology

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1097/01.rli.0000129472.45832.b0

    authors: Taupitz M,Wagner S,Schnorr J,Kravec I,Pilgrimm H,Bergmann-Fritsch H,Hamm B

    更新日期:2004-07-01 00:00:00

  • Ultrasonic detection of osteomyelitis. Pathologic correlation in an animal model.

    abstract::The authors correlated sonographic findings with histologic findings in a rabbit model of osteomyelitis. Staphylococcus aureus osteomyelitis was induced in the femora of 11 New Zealand white rabbits. The opposite leg was used as a control. Sonographic findings showed fluid adjacent to the bone in 11 cases. The fluid w...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199202000-00002

    authors: Abiri MM,DeAngelis GA,Kirpekar M,Abou AN,Ablow RC

    更新日期:1992-02-01 00:00:00

  • Time course of satisfaction of search.

    abstract::"Satisfaction of search" (SOS) refers to the effect in which a second lesion remains undetected after detection of another lesion on the same radiograph. The objective of this study was to clarify our understanding of SOS by relating it to total time of inspection and time intervals before, between, and after discover...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199107000-00003

    authors: Berbaum KS,Franken EA Jr,Dorfman DD,Rooholamini SA,Coffman CE,Cornell SH,Cragg AH,Galvin JR,Honda H,Kao SC

    更新日期:1991-07-01 00:00:00

  • Comparison of Iodine Density Measurement Among Dual-Energy Computed Tomography Scanners From 3 Vendors.

    abstract:OBJECTIVES:The aims of this study were to analyze the effect of dual-energy computed tomography (DECT) scanners and fluid characteristics on iodine quantification and to calculate the measurement variability range induced by those variables. METHODS:We performed an experimental phantom study with 4 mediastinal iodine ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000446

    authors: Kim H,Goo JM,Kang CK,Chae KJ,Park CM

    更新日期:2018-06-01 00:00:00

  • Evaluation of noninvasive follow-up methods for the detection of intracranial in-stent restenosis: a phantom study.

    abstract:OBJECTIVES:Intra-arterial digital subtraction angiography (IA-DSA), an invasive procedure, is the current reference examination after percutaneous transluminal angioplasty and stenting for the detection of in-stent restenosis (ISR). In this phantom study, we evaluated flat-panel angiographic computed tomography after i...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e318276db43

    authors: Psychogios MN,Schramm P,Amelung N,Pilgram-Pastor SM,Gröschel K,Wasser K,Frölich AM,Mohr A,Knauth M

    更新日期:2013-02-01 00:00:00

  • Development of echogenic, plasmid-incorporated, tissue-targeted cationic liposomes that can be used for directed gene delivery.

    abstract:RATIONALE AND OBJECTIVES:Echogenic antibody-conjugated anionic liposomes have been developed that allow directed tissue targeting and acoustic enhancement. These are not efficient for gene delivery. A cationic formulation that allows directed gene delivery while retaining acoustic properties may provide more efficient ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-200012000-00007

    authors: Tiukinhoy SD,Mahowald ME,Shively VP,Nagaraj A,Kane BJ,Klegerman ME,MacDonald RC,McPherson DD,Matsumura JS

    更新日期:2000-12-01 00:00:00

  • Magnetic resonance angiography. Application to the peripheral circulation.

    abstract::Magnetic resonance angiography (MRA) for application in the musculoskeletal system is progressing at a rapid pace. The clinical role of this new technique is still being developed, although a number of uses have already become well recognized, and MRA is diffusing into clinical practice. This article describes the bas...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199212002-00014

    authors: Harms SE,Flamig DP

    更新日期:1992-12-01 00:00:00

  • Embolization of superior mesenteric artery branches in dogs. Ischemic bowel changes depend on location of vessel occlusion and embolic materials.

    abstract:OBJECTIVE:To evaluate the degree of ischemic changes of the small intestine after arterial embolization of proximal or distal arteries with Gelfoam particles and coils in dogs. METHODS:Superselective arterial embolization in 18 dogs was performed using a coaxial catheter system. Gelfoam occlusion of the proximal level...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199910000-00004

    authors: Han YM,Lee JM,Jin KY,Lee SY,Kim CS

    更新日期:1999-10-01 00:00:00

  • Assessment of preoperative magnetic resonance imaging staging in patients with hepatocellular carcinoma undergoing resection compared with the seventh American Joint Committee on Cancer System.

    abstract:OBJECTIVES:The aim of this study was to compare the prognostic utility of a staging system using magnetic resonance imaging (MRI) with the seventh American Joint Committee on Cancer (AJCC) staging system in patients with hepatocellular carcinoma (HCC) who underwent hepatic resection. MATERIALS AND METHODS:A total of 1...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e3182630e8d

    authors: An C,Choi GH,Lee HS,Kim MJ

    更新日期:2012-11-01 00:00:00

  • The influence of contrast medium dose on filtration fraction in the rabbit kidney.

    abstract::We have examined the effect of dose on contrast medium-induced reductions in glomerular filtration in anesthetized rabbits. The fraction of renal plasma flow that is filtered, the filtration fraction, was directly measured by the renal arteriovenous difference method using technetium-99m (99mTc) (Sn) DTPA as the trace...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198309000-00007

    authors: Harvey LA,Caldicott WJ

    更新日期:1983-09-01 00:00:00

  • Slice simulation from a model of the parenchymous vascularization to evaluate texture features: work in progress.

    abstract:RATIONALE AND OBJECTIVES:To demonstrate the usefulness of a model of the parenchymous vascularization to evaluate texture analysis methods. METHODS:Slices with thickness varying from 1 to 4 mm were reformatted from a 3D vascular model corresponding to either normal tissue perfusion or local hypervascularization. Param...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199903000-00004

    authors: Rolland Y,Bézy-Wendling J,Duvauferrier R,Coatrieux JL

    更新日期:1999-03-01 00:00:00

  • Clinical experience with saralasin infusion in hypertensive patients.

    abstract::Renal arteriography gives a reliable anatomic delineation of the renal vasculature. However, the presence of renal arterial disease does not determine the physiologic significance of the lesion. The intravenous infusion of saralasin, a specific angiotensin II antagonist, has been investigated as a method for identify...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-197711000-00006

    authors: Tegtmeyer CJ,Latour EA,Vaughan ED Jr,Ayers CR,Carey RM,Wellons HA Jr

    更新日期:1977-11-01 00:00:00

  • Control of experimental traumatic hepatic hemorrhage by transcatheter embolization.

    abstract::The feasibility of control of traumatic hepatic hemorrhage by angiographic transcatheter embolization was investigated. Bleeding sites were created in the livers of each of twelve dogs, and the hepatic artery was occluded with Gelfoam. Successful control of bleeding was demonstrated by postembolization angiography in ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-197801000-00014

    authors: Tyler T,Rosenbaum HD

    更新日期:1978-01-01 00:00:00

  • BR1: a new ultrasonographic contrast agent based on sulfur hexafluoride-filled microbubbles.

    abstract:RATIONALE AND OBJECTIVES:The basic characteristics of BR1, a novel echo contrast agent based on stabilized sulfur hexafluoride (SF6) microbubbles have been evaluated. METHODS:The authors determined the physicochemical properties (bubble concentration, bubble size distribution, resistance to pressure, and stability) an...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199508000-00001

    authors: Schneider M,Arditi M,Barrau MB,Brochot J,Broillet A,Ventrone R,Yan F

    更新日期:1995-08-01 00:00:00

  • Intrapulmonary 3He gas distribution depending on bolus size and temporal bolus placement.

    abstract:OBJECTIVE:Dynamic ventilation (3)He-MRI is a new method to assess pulmonary gas inflow. As differing airway diameters throughout the ventilatory cycle can influence gas inflow this study intends to investigate the influence of volume and timing of a He gas bolus with respect to the beginning of the tidal volume on insp...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e3181690111

    authors: Gast KK,Hawig K,Windirsch M,Markstaller K,Schreiber WG,Schmiedeskamp J,Düber C,Kauczor HU,Heussel CP

    更新日期:2008-06-01 00:00:00

  • Reproducibility, accuracy, and predictors of accuracy for the detection of coronary atherosclerotic plaque composition by computed tomography: an ex vivo comparison to intravascular ultrasound.

    abstract:PURPOSE:To determine the reproducibility, accuracy, and predictors of accuracy of computed tomography (CT) angiography to detect and characterize coronary atherosclerotic plaque as compared with intravascular ultrasound. METHODS:Ten ex vivo human coronary arteries were imaged in a moving phantom by dual-source CT (col...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e3181e0a541

    authors: van der Giessen AG,Toepker MH,Donelly PM,Bamberg F,Schlett CL,Raffle C,Irlbeck T,Lee H,van Walsum T,Maurovich-Horvat P,Gijsen FJ,Wentzel JJ,Hoffmann U

    更新日期:2010-11-01 00:00:00

  • Incompatibility of water-soluble contrast media and intravascular pharmacologic agents. An in vitro study.

    abstract::In vitro incompatibilities between nine water-soluble contrast media and 21 intravascular pharmacologic agents were investigated using naked-eye observation and a centrifuge. Most of the previously reported incompatibilities were verified, and a few new incompatibilities were discovered: phentolamine mesylate with dia...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199201000-00008

    authors: Kim SH,Lee HK,Han MC

    更新日期:1992-01-01 00:00:00

  • T2-Weighted 4D Magnetic Resonance Imaging for Application in Magnetic Resonance-Guided Radiotherapy Treatment Planning.

    abstract:OBJECTIVES:The aim of this study was to develop and verify a method to obtain good temporal resolution T2-weighted 4-dimensional (4D-T2w) magnetic resonance imaging (MRI) by using motion information from T1-weighted 4D (4D-T1w) MRI, to support treatment planning in MR-guided radiotherapy. MATERIALS AND METHODS:Ten pat...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000381

    authors: Freedman JN,Collins DJ,Bainbridge H,Rank CM,Nill S,Kachelrieß M,Oelfke U,Leach MO,Wetscherek A

    更新日期:2017-10-01 00:00:00

  • Saturation kinetics of iopanoate in dogs with an intact enterohepatic circulation. Before and after phenobarbital induction.

    abstract::Capacity-limited elimination of sodium iopanoate and a reproducible apparent transport maximum (Tm) were demonstrated in nonoperated dogs having an intact enterohepatic circulation and normal endogenous bile salt pool. Using a multiple infusion technique, estimation of apparent Tm of iopanoate in the liver was possibl...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-197601000-00007

    authors: Herzog RJ,Nelson JA,Staubus AE

    更新日期:1976-01-01 00:00:00