Abstract:
:Capacity-limited elimination of sodium iopanoate and a reproducible apparent transport maximum (Tm) were demonstrated in nonoperated dogs having an intact enterohepatic circulation and normal endogenous bile salt pool. Using a multiple infusion technique, estimation of apparent Tm of iopanoate in the liver was possible without sampling either bile or urine. Values obtained for apparent Tm of iopanoate in dogs with normal bile salt pool were similar to those obtained in studies of dogs with chronic bile fistulas. Use of this technique in 4 dogs demonstrated that pretreatment with phenobarbital significantly increases apparent Tm of iopanoate.
journal_name
Invest Radioljournal_title
Investigative radiologyauthors
Herzog RJ,Nelson JA,Staubus AEdoi
10.1097/00004424-197601000-00007keywords:
subject
Has Abstractpub_date
1976-01-01 00:00:00pages
32-8issue
1eissn
0020-9996issn
1536-0210journal_volume
11pub_type
杂志文章abstract:OBJECTIVE:BR55, a vascular endothelial growth factor receptor 2 (VEGFR2)-specific ultrasound molecular contrast agent (MCA), has shown promising results in multiple preclinical models regarding cancer imaging. In this first-in-human, phase 0, exploratory study, we investigated the feasibility and safety of the MCA for ...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0000000000000362
更新日期:2017-07-01 00:00:00
abstract:OBJECTIVE:The aim of this study was to evaluate the diagnostic value of x-ray dark-field imaging in projection radiography-based depiction of pneumothoraces in the neonatal murine lung, a potentially life-threatening medical condition that requires a timely and correct diagnosis. MATERIALS AND METHODS:By the use of a ...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0000000000000285
更新日期:2016-10-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:To improve the accuracy of magnetic resonance imaging (MRI) in evaluating the response of osteosarcomas to preoperative chemotherapy, the authors developed a technique of mapping tumor necrosis and viability by quantitating slope values of gadolinium-DTPA (Gd-DTPA) uptake on dynamic fast low-an...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199205000-00010
更新日期:1992-05-01 00:00:00
abstract:OBJECTIVES:To test the feasibility of combining inner-volume imaging (IVI) techniques with conventional multishot periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER) techniques for targeted-PROPELLER magnetic resonance imaging. MATERIALS AND METHODS:Perpendicular section-selective ...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0b013e3181a8b015
更新日期:2009-08-01 00:00:00
abstract:OBJECTIVES:The objective of this study was to assess the feasibility of the combination of magnetic resonance (MR)-guided biopsy (MRGB) and diagnostic 3T MR imaging in the localization of local recurrence of prostate cancer (PCa) after external beam radiation therapy (EBRT). MATERIALS AND METHODS:Twenty-four consecuti...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0b013e3181c7bcda
更新日期:2010-03-01 00:00:00
abstract::We compared the damage resulting from intradermal injection of four commonly used radiographic contrast media in laboratory rats. Sixty percent meglumine diatrizoate (Reno M 60) and ioxaglate (Hexabrix) produced significantly more ulceration and crusting on gross inspection and more necrosis, edema, and hemorrhage on ...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199005000-00006
更新日期:1990-05-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:To test noninvasive inductive heating of implanted vascular stents as an alternative approach for reduction or prevention of neointimal hyperplasia. METHODS:Calorimetric pretests were performed to get an orientation on the different parameters of influence for inductive heating of stents. The ...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/01.rli.0000117881.42422.72
更新日期:2004-05-01 00:00:00
abstract:OBJECTIVES:In late December 2019, an outbreak of coronavirus disease (COVID-19) in Wuhan, China was caused by a novel coronavirus, newly named severe acute respiratory syndrome coronavirus 2. We aimed to quantify the severity of COVID-19 infection on high-resolution chest computed tomography (CT) and to determine its r...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0000000000000674
更新日期:2020-06-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:To develop a new animal model for the evaluation of the renal tolerance of contrast agent and its application to diatrizoate and iotrolan injections in comparison to saline and mannitol solution. MATERIALS AND METHODS:The nephrotoxic potential of intravenously injected contrast agents in Beagl...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/01.rli.0000087096.61127.13
更新日期:2003-11-01 00:00:00
abstract:OBJECTIVES:To prospectively evaluate accuracy of biliary anatomy depiction and quality of biliary tract visualization of magnetic resonance cholangiography (MRC) at 3.0 T in living potential liver donors (LPLDs). MATERIALS AND METHODS:Our institutional review board approved this study and did not require patient's inf...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0b013e31817e9b52
更新日期:2008-08-01 00:00:00
abstract::A technique to measure absolute arterial blood flow in ml/min has been developed utilizing software programs with high-speed digital recording for the off-line analysis of intra-arterial injections of contrast medium. Measurements of pulsatile flow in a phantom for a physical flow model showed that calculations with t...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198503000-00017
更新日期:1985-03-01 00:00:00
abstract::We examined the acute systemic and renal hemodynamic effects of intravenous meglumine/sodium diatrizoate-76% and iopamidol in euvolemic and dehydrated dogs. The physiologic responses were compared with acute changes in the level of an endogenous heparin-like material (EHM). One of eight dehydrated dogs receiving diatr...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198610000-00005
更新日期:1986-10-01 00:00:00
abstract:PURPOSE:To determine the reproducibility, accuracy, and predictors of accuracy of computed tomography (CT) angiography to detect and characterize coronary atherosclerotic plaque as compared with intravascular ultrasound. METHODS:Ten ex vivo human coronary arteries were imaged in a moving phantom by dual-source CT (col...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0b013e3181e0a541
更新日期:2010-11-01 00:00:00
abstract:OBJECTIVES:We sought to assess large bowel motility, induced by 2 prokinetic agents, senna tea and erythromycin, using functional cine magnetic resonance imaging (MRI). MATERIALS AND METHODS:Twelve volunteers underwent functional cine MRI before and after the administration of senna tea or erythromycin. The protocol c...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/01.rli.0000183054.43131.a8
更新日期:2005-11-01 00:00:00
abstract:OBJECTIVE:The purpose of this study was to assess the ability of a flow-sensitive alternating inversion recovery-arterial spin labeling (FAIR-ASL) technique to track renal perfusion changes during pharmacologic and physiologic alterations in renal blood flow using microspheres as a gold standard. MATERIALS AND METHODS...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0b013e3181f5e101
更新日期:2011-02-01 00:00:00
abstract:AIM:: We sought to improve the clinical interpretation of first-pass myocardial magnetic resonance perfusion. Parametric analyses of the myocardial distribution of the contrast agent have been proposed. The objective of the present study was to compare the effectiveness of visual analysis and of a parametric approach i...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/01.rli.0000197980.89673.4b
更新日期:2006-04-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:To compare technical aspects and neointima formation of a new Nitinol stent and a Wallstent. METHODS:A Nitinol sten and a Wallstent were placed into the iliac arteries of 14 sheep (total of 28 stents) and followed angiographically. Seven sheep were killed after 1 month and 7 after 4.5 months. ...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199507000-00004
更新日期:1995-07-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:The authors compare the magnetic resonance (MR) phase contrast flow velocity measurements in varying concentric stenoses with invasive measurements obtained with a Doppler guidewire. METHODS:Flow velocity measurements were obtained using a calibrated 0.018 inch 12 MHz Doppler guidewire and a 1...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199808000-00001
更新日期:1998-08-01 00:00:00
abstract::The microangiographic anatomy of the cat's eye is presented. The characteristic vascular pattern of each of the three distinct circulations, retinal choroidal, and ciliary is described and illustrated. ...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-197501000-00007
更新日期:1975-01-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:Laser-induced interstitial thermotherapy (LITT) may become an attractive modality for minimally invasive tumor therapy. Magnetic resonance imaging (MRI) could be used to assist this procedure. METHODS:A T1-weighted turbo fast low-angle shot (FLASH) sequence for on-line monitoring of the laser-...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199403000-00015
更新日期:1994-03-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:To evaluate the safety and pharmacokinetics of a newly developed MR contrast medium consisting of very small superparamagnetic iron oxide particles (VSOP) coated with citrate (VSOP-C184) in a clinical phase I trial. METHODS:A total of 18 healthy subjects received either VSOP-C184 (core diamete...
journal_title:Investigative radiology
pub_type: 临床试验,杂志文章,随机对照试验
doi:10.1097/01.rli.0000129472.45832.b0
更新日期:2004-07-01 00:00:00
abstract::French physicians must obtain their patient's consent before carrying out an action that interferes with the patient's corporal integrity. The doctor must use simple, approximate, intelligent, and honest words that help the patient to reach the indispensable decision. Proof of lack of consent lies with the patient. Th...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198809001-00006
更新日期:1988-09-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:Gd-DTPA is a well-characterized, safe contrast agent frequently used in magnetic resonance imaging (MRI) of the central nervous system. The purpose of this double-blind, comparative MRI study of brain, spine, trunk, and limbs was to evaluate the safety and efficacy of Gd-DOTA versus Gd-DTPA in ...
journal_title:Investigative radiology
pub_type: 临床试验,杂志文章,随机对照试验
doi:10.1097/00004424-199502000-00002
更新日期:1995-02-01 00:00:00
abstract::Gelatin encapsulated nitrogen microbubbles were effective ultrasonic contrast agents in in vitro phantom and in vivo rabbit V2 carcinoma studies. Intra-arterial injection of 80-micrometer gelatin encapsulated nitrogen microbubbles appeared to improve tumor visualization by rim enhancement, which persisted for several ...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198005000-00013
更新日期:1980-05-01 00:00:00
abstract::The effect of three iodinated contrast media (CM) on human plasma butyrylcholinesterase (BuChE) activity was studied during the intravenous pyelography (i.v.P). BuChE is an enzyme that participates in the metabolism of acetylcholine and hydrolyzes food esters and drugs such as nondepolarizing muscle relaxants and loca...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199805000-00008
更新日期:1998-05-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:At many institutions, three-dimensional magnetic resonance imaging (MRI) is routinely used for examination of the knee. Multiplanar reconstruction (MPR) is a method of displaying three-dimensional datasets. The authors assessed the usefulness of MPR for evaluating knee MRI datasets by comparing...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199302000-00011
更新日期:1993-02-01 00:00:00
abstract:OBJECTIVES:We compared the image quality and diagnostic performance of 2 fat-suppression methods for black-blood T2-weighted fast spin-echo (FSE), which are as follows: (a) short T1 inversion recovery (STIR; FSE-STIR) and (b) spectral adiabatic inversion recovery (SPAIR; FSE-SPAIR), for detection of acute myocardial in...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0b013e3182718672
更新日期:2013-01-01 00:00:00
abstract:OBJECTIVE:Though functional intravascular parameters such as blood velocity and direction of blood flow are available via imaging modalities such as Doppler ultrasound and phase contrast magnetic resonance imaging, such quantitative information is not yet supported by computed tomography (CT). In this study, we examine...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0b013e3181ea3588
更新日期:2010-12-01 00:00:00
abstract::The design and implementation of a digital radiology image management system requires the definition, evaluation, and comparison of appropriate measures of system performance. The mean throughput rate is an important measure of the actual performance of a finished system. The mean throughput rate identifies the transm...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198602000-00014
更新日期:1986-02-01 00:00:00
abstract::Left ventricular volume has been measured with ultrafast computed tomography. However, the accuracy with which this can be done is unknown. We therefore imaged with ultrafast computed tomography 11 rectangular phantoms, 20 to 225 ml, and 17 left ventricular casts, 15 to 112 ml. Two observers planimetered serial tomogr...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199101000-00006
更新日期:1991-01-01 00:00:00