Abstract:
OBJECTIVES:To test the feasibility of combining inner-volume imaging (IVI) techniques with conventional multishot periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER) techniques for targeted-PROPELLER magnetic resonance imaging. MATERIALS AND METHODS:Perpendicular section-selective gradients for spatially selective excitation and refocusing RF pulses were applied to limit the refocused field-of-view (FOV) along the phase-encoding direction for each rectangular blade image. We performed comparison studies in phantoms and normal volunteers by using targeted-PROPELLER methods for a wide range of imaging applications that commonly use turbo-spin-echo (TSE) approaches (brain, abdominal, vessel wall, cardiac). RESULTS:In these initial studies, we demonstrated the feasibility of using targeted-PROPELLER approaches to limit the imaging FOV thereby reducing the number of blades or permitting increased spatial resolution without commensurate increases in scan time. Both phantom and in vivo motion studies demonstrated the potential for more robust regional self-navigated motion correction compared with conventional full FOV PROPELLER methods. CONCLUSION:We demonstrated that the reduced FOV targeted-PROPELLER technique offers the potential for reducing imaging time, increasing spatial resolution, and targeting specific areas for robust regional motion correction.
journal_name
Invest Radioljournal_title
Investigative radiologyauthors
Deng J,Larson ACdoi
10.1097/RLI.0b013e3181a8b015subject
Has Abstractpub_date
2009-08-01 00:00:00pages
454-62issue
8eissn
0020-9996issn
1536-0210journal_volume
44pub_type
杂志文章abstract::Observation of the relaxivity of MRI contrast media over a wide range of magnetic fields is not only necessary for predicting their efficiency at any field but also compulsory for understanding and improving their mechanisms of action. The best experimental approach to this problem is the field cycling method, which a...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198809001-00047
更新日期:1988-09-01 00:00:00
abstract:OBJECTIVES:The aim of this study was to assess the effectiveness of a model-based iterative reconstruction (MBIR) in improving image quality and diagnostic performance of ultralow-dose computed tomography (ULDCT) of the lung. MATERIALS AND METHODS:The institutional review board approved this study, and all patients pr...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0b013e3182562a89
更新日期:2012-08-01 00:00:00
abstract:OBJECTIVE:To evaluate the degree of ischemic changes of the small intestine after arterial embolization of proximal or distal arteries with Gelfoam particles and coils in dogs. METHODS:Superselective arterial embolization in 18 dogs was performed using a coaxial catheter system. Gelfoam occlusion of the proximal level...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199910000-00004
更新日期:1999-10-01 00:00:00
abstract::Magnetic resonance (MR) methods have been used to study the metabolic and vascular response of model tumors to tumor necrosis factor (TNF). Magnetic resonance measurements demonstrated acute reductions in tumor blood flow, measured from tumor uptake of D2O, and in tumor adenosine triphosphate (ATP), measured by 31P ma...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198912000-00022
更新日期:1989-12-01 00:00:00
abstract:PURPOSE:The relaxivities of 3 macrocyclic gadolinium-based contrast agents (GBCAs) were determined in human plasma and blood under standardized and clinically relevant laboratory conditions. METHODS:The T1 relaxivity, r1, was determined in human plasma at 1.5, 3, and 7 T, and in human blood at 3 T at 37°C in phantoms ...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0000000000000577
更新日期:2019-09-01 00:00:00
abstract::Four-hour delayed contrast-enhanced computed tomography (DCECT) shows promise for improved detection of focal liver lesions. No previous studies have examined the use of nonionic contrast materials for DCECT. The authors undertook a case-controlled study in monkeys to define the relative efficacies of iopamidol and di...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198910000-00010
更新日期:1989-10-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:To assess the influence of injection rates and volumes on the arrival time of contrast material (CM) in the common carotid artery, the jugular vein and the resulting arterial-venous transit time. Additionally the relationship between injection parameters and the extent of a CM plateau was evalu...
journal_title:Investigative radiology
pub_type: 临床试验,杂志文章,随机对照试验
doi:10.1097/01.rli.0000105040.40925.c8
更新日期:2004-02-01 00:00:00
abstract::A new nonionic contrast medium (CM), ioxilan, was compared with iohexol and iopamidol. Following incubation of whole heparinized blood with CM, the morphology and osmotic fragility of erythrocytes were studied, the former by transmission electron microscopy. Effects on platelets and hemocoagulation were determined by ...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198809001-00032
更新日期:1988-09-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:Two independent gold standards and diagnoses from three-dimensional computed tomography (CT) images were used to examine the possibility that craniosynostosis is a binary abnormality that potentially may be diagnosed without error. METHODS:Surgical reports, histology of excised sutures, and th...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199410000-00005
更新日期:1994-10-01 00:00:00
abstract:PURPOSE:We sought to evaluate the potential of dynamic contrast enhancement after the intravenous administration of an iodine-based contrast medium in full-field digital mammography. MATERIAL AND METHODS:A protocol for image acquisition was established for contrast-enhanced mammography and the mammography unit (Senogr...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/01.rli.0000167421.83203.4e
更新日期:2005-07-01 00:00:00
abstract::Experimental pulmonary arteritis was produced in rabbits by intravenous injection of alveolar macrophages from donor rabbits. These animals, along with matched controls, were studied with pulmonary angiography to test the hypothesis that angiography could detect the vasculitic process in life. The animals were then sa...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198007000-00005
更新日期:1980-07-01 00:00:00
abstract::The effect of contrast media (CM) dilution on contrast enhancement was studied using CM representing four structurally different molecular types at osmolalities ranging from 135 to 1340 mosm/kg. Diatrizoate (ionic monomer), iopamidol (nonionic monomer), ioxaglate (ionic dimer), and iodecol (nonionic dimer) were each g...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198809001-00014
更新日期:1988-09-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:To investigate the capacity of manganese dipyridoxyl diphosphate (MnDPDP)-enhanced magnetic resonance imaging (MRI) to discriminate the injured myocardium from the normal myocardium in a cat model. MATERIALS AND METHODS:Fourteen cats were prepared for acute myocardial infarction with 90-minute...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:
更新日期:2005-01-01 00:00:00
abstract::An ultrasound phantom was constructed simulating fetal femurs in amniotic fluid. Bones of 26, 36, 50, 58, and 70 mm, representative of gestational ages ranging from 17 to 36 weeks, were scanned with mechanical sector, phased sector, and linear array systems (ATL, Diasonics, Acuson, and GE). Measurements were made with...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198505000-00016
更新日期:1985-05-01 00:00:00
abstract:OBJECTIVE:The objective of this study was to validate quantitation of R2* and DeltaR2* measurements obtained with a 3-dimensional (3-D) multiple gradient-recalled echo (mGRE) sequence for evaluating intrarenal oxygenation in humans. MATERIALS AND METHODS:Validation was accomplished (1) by comparing R2* values with pre...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/01.rli.0000187166.43871.fb
更新日期:2006-02-01 00:00:00
abstract::A method is presented by whichcomputed tomography scans carried out at a number of energies may be utilized to obtain cross-sectional images of density and atomic number in addition to the conventional array of linear attenuation coefficients. This type of analysis has been carried out for various substances of biolog...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-197703000-00016
更新日期:1977-03-01 00:00:00
abstract::The biliary and urinary excretion of sodium tyropanoate (Bilopaque) and sodium ipodate (Oragrafin) were studied in unanesthetized bile-fistula dogs using stepwise, increasing, intravenous infusions of the contrast materials. A constant intravenous infusion of sodium taurocholate was administered at the rate of either ...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-197701000-00017
更新日期:1977-01-01 00:00:00
abstract::Renal arteriography gives a reliable anatomic delineation of the renal vasculature. However, the presence of renal arterial disease does not determine the physiologic significance of the lesion. The intravenous infusion of saralasin, a specific angiotensin II antagonist, has been investigated as a method for identify...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-197711000-00006
更新日期:1977-11-01 00:00:00
abstract:PURPOSE:The aim was to investigate the feasibility and image quality of prospective respiratory gating for 3-D computed tomography (CT) of the lung. MATERIAL AND METHODS:Eight anesthetized pigs underwent prospectively gated multidetector computed tomography using 2 devices: a charge-coupled device (CCD) camera and a l...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/01.rli.0000208926.98693.b6
更新日期:2006-05-01 00:00:00
abstract::The authors investigated the effect on the brain of red blood cells that had been modified by contrast media. Rat blood was mixed with an equivolume of contrast media, and up to 200 microL of the mixture was infused to the internal carotid artery of the rat. Evans blue was administered intravenously to assess the inte...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198905000-00009
更新日期:1989-05-01 00:00:00
abstract::Advances in the field of magnetic resonance (MR) as it pertains to clinical diagnostic radiology are examined in this review on the basis of publications in Investigative Radiology over the past 2 years (2005-2006). The articles published during that timeframe are discussed, organizationally wise, by anatomic region w...
journal_title:Investigative radiology
pub_type: 杂志文章,评审
doi:10.1097/01.rli.0000250461.03245.5c
更新日期:2006-12-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:The objective is to assess the diagnostic accuracy and interobserver variability of multiphase 3D gadolinium-enhanced magnetic resonance angiography (3D-Gd-MRA) for assessment of abdominal and pelvic vascular disease. METHODS:In 41 patients from two different institutions multiphase 3D-Gd-MRA ...
journal_title:Investigative radiology
pub_type: 杂志文章,多中心研究
doi:10.1097/00004424-200201000-00005
更新日期:2002-01-01 00:00:00
abstract::The ideal contrast agent in patients suspected of having gastrointestinal perforation is an iso-osmolar, or nearly iso-osmolar substance, that causes no peritoneal reaction. Iopamidol is a nonionic water-soluble contrast medium that may be considered in such situations. Intraperitoneal injections of ionic and nonionic...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199002000-00008
更新日期:1990-02-01 00:00:00
abstract:OBJECTIVES:The objectives of this study were to assess the feasibility of magnetic resonance cholangiography (MRC) using biliary-secreted gadoxetic acid at 7 T and to compare it with T2-weighted (w) MRC at 3 T. MATERIALS AND METHODS:Ten healthy volunteers were examined on a 7-T whole-body magnetic resonance system. T2...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0000000000000004
更新日期:2014-05-01 00:00:00
abstract:OBJECTIVES:The objective of this study was to prospectively compare diagnostic performance and time efficiency of a double-reading paradigm in which a first-reader computer-aided detection (CAD) is followed by a fast 2-dimensional review (DR FR-CAD) with those of a double reading with second-reader CAD (SR CAD). MATER...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0000000000000009
更新日期:2014-03-01 00:00:00
abstract::Thirty patients [four normals, eight with mild and 18 with severe coronary artery disease (CAD)] were studied to evaluate left ventricular function type and post coronary angiography. The end diastolic volume (EDV), end systolic volume (ESV), ejection fraction (EF) and the regional contractility fractions (RCF) of eig...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-197603000-00009
更新日期:1976-03-01 00:00:00
abstract::Percutaneous injection of absolute ethanol into adenocarcinomas implanted in the hind leg of rats was evaluated as a potential cancer treatment. Intramuscular alcohol injections up to 10 mL/kg produced a local dose-dependent coagulation necrosis followed by granulation tissue formation and subsequent fibrosis but no a...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198706000-00005
更新日期:1987-06-01 00:00:00
abstract::Using simple surgical techniques, experimental carotid aneurysms are created which simulate some types of human berry aneurysms, both in hemodynamic and radiographic behavior. End to side anastomoses of an external jugular vein graft to the common carotid artery can be carried out by radiologic personnel with no forma...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-197703000-00009
更新日期:1977-03-01 00:00:00
abstract:OBJECTIVES:The purpose of this study was to assess whether fluorochrome-coupled bacterial magnetic nanoparticles can be used as bimodal contrast agent for both magnetic resonance imaging (MRI) and near-infrared fluorescence optical (NIRF) imaging of cultured macrophages. MATERIALS AND METHODS:Bacterial magnetic nanopa...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/01.rli.0000255832.44443.e7
更新日期:2007-04-01 00:00:00
abstract:OBJECTIVE:The objective of this study was to elucidate the mechanism of hepatic parenchyma-specific contrast of Sonazoid (microbubble contrast agent) using microscopic techniques. MATERIALS AND METHODS:Sonazoid was intravenously injected into rats to investigate the microbubble dynamics and distribution within hepatic...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0b013e31805f2682
更新日期:2007-09-01 00:00:00