Experimental pulmonary arteritis.

Abstract:

:Experimental pulmonary arteritis was produced in rabbits by intravenous injection of alveolar macrophages from donor rabbits. These animals, along with matched controls, were studied with pulmonary angiography to test the hypothesis that angiography could detect the vasculitic process in life. The animals were then sacrificed and postmortem angiography and histologic studies of the fixed inflated lung were used to locate the vascular lesions. The authors conclude that pulmonary vasculitis can be detected by angiography when the chest x-ray is normal.

journal_name

Invest Radiol

journal_title

Investigative radiology

authors

Hicken P,Hogg JC,Pare PD

doi

10.1097/00004424-198007000-00005

subject

Has Abstract

pub_date

1980-07-01 00:00:00

pages

299-307

issue

4

eissn

0020-9996

issn

1536-0210

journal_volume

15

pub_type

杂志文章
  • Blood velocity calculated from volumetric dynamic computed tomography angiography.

    abstract:OBJECTIVE:Though functional intravascular parameters such as blood velocity and direction of blood flow are available via imaging modalities such as Doppler ultrasound and phase contrast magnetic resonance imaging, such quantitative information is not yet supported by computed tomography (CT). In this study, we examine...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e3181ea3588

    authors: Barfett JJ,Fierstra J,Mikulis DJ,Krings T

    更新日期:2010-12-01 00:00:00

  • Comparison of Fenestra VC Contrast-enhanced computed tomography imaging with gadopentetate dimeglumine and ferucarbotran magnetic resonance imaging for the in vivo evaluation of murine liver damage after ischemia and reperfusion.

    abstract:OBJECTIVES:Comparison of intravenous Fenestra VC-enhanced computed tomography (CT) with gadopentetate dimeglumine and Ferucarbotran contrast-enhanced magnetic resonance imaging (MRI) for the in vivo imaging of hepatic ischemia/reperfusion injury (IRI) in a murine model. MATERIAL AND METHODS:After induction of hepatic ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e318155aa2e

    authors: Choukèr A,Lizak M,Schimel D,Helmberger T,Ward JM,Despres D,Kaufmann I,Bruns C,Löhe F,Ohta A,Sitkovsky MV,Klaunberg B,Thiel M

    更新日期:2008-02-01 00:00:00

  • 3.0 Tesla high spatial resolution contrast-enhanced magnetic resonance angiography (CE-MRA) of the pulmonary circulation: initial experience with a 32-channel phased array coil using a high relaxivity contrast agent.

    abstract:PURPOSE:To evaluate the technical feasibility of high spatial resolution contrast-enhanced magnetic resonance angiography (CE-MRA) with highly accelerated parallel acquisition at 3.0 T using a 32-channel phased array coil, and a high relaxivity contrast agent. MATERIALS AND METHODS:Ten adult healthy volunteers (5 men,...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/01.rli.0000261937.77365.6a

    authors: Nael K,Fenchel M,Krishnam M,Finn JP,Laub G,Ruehm SG

    更新日期:2007-06-01 00:00:00

  • Accuracy of ultrasound in fetal femur length determination. Ultrasound phantom study.

    abstract::An ultrasound phantom was constructed simulating fetal femurs in amniotic fluid. Bones of 26, 36, 50, 58, and 70 mm, representative of gestational ages ranging from 17 to 36 weeks, were scanned with mechanical sector, phased sector, and linear array systems (ATL, Diasonics, Acuson, and GE). Measurements were made with...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198505000-00016

    authors: Gamba JL,Bowie JD,Dodson WC,Hedlund LW

    更新日期:1985-05-01 00:00:00

  • Percutaneous radiofrequency ablation of hepatic colorectal metastases: technique, indications, results, and new promises.

    abstract::Surgical resection is the standard of care for colorectal metastases isolated to the liver. However, only 10-25% of the patients are eligible for resection because of extent and location of the disease in the liver or concurrent medical conditions. Image-guided radiofrequency (RF) ablation is a minimally invasive tech...

    journal_title:Investigative radiology

    pub_type: 杂志文章,评审

    doi:10.1097/00004424-200411000-00007

    authors: Lencioni R,Crocetti L,Cioni D,Della Pina C,Bartolozzi C

    更新日期:2004-11-01 00:00:00

  • Alteration of human tumor cell adhesion by high-strength static magnetic fields.

    abstract:RATIONALE AND OBJECTIVES:The authors investigated whether the ability of human malignant melanoma cells to increase in cell number or their ability to remain viable was compromised by high-field strength static magnetic fields. Normal human fibroblasts also were studied to determine if any magnetic field-related altera...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199210000-00014

    authors: Short WO,Goodwill L,Taylor CW,Job C,Arthur ME,Cress AE

    更新日期:1992-10-01 00:00:00

  • Computed Tomography for 4-Dimensional Angiography and Perfusion Imaging of the Prostate for Embolization Planning of Benign Prostatic Hyperplasia.

    abstract:OBJECTIVES:The aim of this study was to evaluate the feasibility of a computed tomography (CT) protocol enabling the visualization of the prostatic artery (PA) before prostatic artery embolization (PAE) in benign prostatic hyperplasia, which provides quantitative perfusion information of the prostate gland. MATERIALS ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000582

    authors: Kobe A,Puippe G,Klotz E,Alkadhi H,Pfammatter T

    更新日期:2019-10-01 00:00:00

  • Vein graft-coated stents for endovascular occlusion of canine experimental arteriovenous fistulae.

    abstract:RATIONALE AND OBJECTIVES:To evaluate different vein graft-coated stent systems in the endovascular treatment of experimental arteriovenous fistulae (AVF) in a canine model. METHODS:Bilateral carotid-to-external jugular vein AVF were created. Two balloon-expandable tantalum stents (Strecker stent), two self-expanding n...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199901000-00004

    authors: Schellhammer F,Wahkloo AK,Nagursky H,Schumacher M

    更新日期:1999-01-01 00:00:00

  • Magnetic resonance osteodensitometry in human heel bones: correlation with quantitative computed tomography using different measuring parameters.

    abstract:RATIONALE AND OBJECTIVES:Density of trabecular bone structures in human heel bones was assessed by 3D magnetic resonance (MR) gradient echo imaging (GEI) with multiple echoes. Different spatial resolutions were applied to investigate the influence of the pixel size on signal characteristics in GEI and to find suitable ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-200007000-00001

    authors: Machann J,Schnatterbeck P,Raible A,Lutz O,Claussen CD,Schick F

    更新日期:2000-07-01 00:00:00

  • Microbubble contrast agents: targeted ultrasound imaging and ultrasound-assisted drug-delivery applications.

    abstract::The use of microbubble contrast agents for general tissue delineation and perfusion enjoys steady interest in ultrasound imaging. Microbubbles as contrast materials require a small dosage and show excellent detection sensitivity. Targeting ligands on the surface of microbubbles permit the selective accumulation of the...

    journal_title:Investigative radiology

    pub_type: 杂志文章,评审

    doi:10.1097/01.rli.0000199292.88189.0f

    authors: Klibanov AL

    更新日期:2006-03-01 00:00:00

  • Semiquantitative assessment of myocardial perfusion using magnetic resonance imaging: evaluation of appropriate thresholds and segmentation models.

    abstract:RATIONALE AND OBJECTIVES:The aim of the study was to determine optimal thresholds for semiquantitative perfusion parameters and to evaluate the influence of different segmentation models in detecting malperfused regions. MATERIAL AND METHODS:In 6 healthy subjects and 13 patients with coronary artery disease, contrast-...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/01.rli.0000133816.83192.38

    authors: Fenchel M,Kramer U,Helber U,Stauder NI,Franow A,Claussen CD,Miller S

    更新日期:2004-09-01 00:00:00

  • Reduction of Metal Artifacts and Improvement in Dose Efficiency Using Photon-Counting Detector Computed Tomography and Tin Filtration.

    abstract:OBJECTIVES:The aim of this study was to investigate the impact on metal artifacts and dose efficiency of using a tin filter in combination with high-energy threshold (TH) images of a photon-counting detector (PCD) computed tomography (CT) system. MATERIALS AND METHODS:A 3D-printed spine with pedicle screws was scanned...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000535

    authors: Zhou W,Bartlett DJ,Diehn FE,Glazebrook KN,Kotsenas AL,Carter RE,Fletcher JG,McCollough CH,Leng S

    更新日期:2019-04-01 00:00:00

  • MRI dosimetry: a fast quantitative MRI method to determine 3D absorbed dose distributions.

    abstract:RATIONALE AND OBJECTIVES:Magnetic resonance imaging (MRI) techniques seem to be very promising for 3D dosimetry studies, but long imaging acquisition time limits their use. A new fast T1 mapping protocol, easy to implement on a conventional MR imager, has been used to determine dose distributions on Fricke gels. METHO...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199903000-00014

    authors: Calmet C,Vincensini D,Bonnet J,Bertino C,Catala A,Martinez M,Joffre F

    更新日期:1999-03-01 00:00:00

  • Developments in X-Ray Contrast Media and the Potential Impact on Computed Tomography.

    abstract::Over the past 120 years, continuous developments in medical imaging has improved diagnosis and treatment for many diseases and has thereby improved treatment outcome and quality of life of many patients. The number of computed tomography (CT) examinations is today increasing by 4% per year worldwide, for a total of ap...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000696

    authors: Schöckel L,Jost G,Seidensticker P,Lengsfeld P,Palkowitsch P,Pietsch H

    更新日期:2020-09-01 00:00:00

  • Contrast and electrolyte dynamics of the intravenous pyelogram. II. Disparities in serum and urine concentrations of meglumine and anion.

    abstract::Intravenous or intra-aortic injections of meglumine iothalamate in dogs indicate a slightly different tissue distribution and excretory pattern of the meglumine cation and the iothalamate anion. Differences in serum and urinary concentrations of these ions suggest some cellular penetration of the meglumine anion. In a...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-197507000-00004

    authors: Lasser EC,Lang JH,Hamblin AE,Rosen L

    更新日期:1975-07-01 00:00:00

  • Manganese dipyridoxyl diphosphate (MnDPDP)-enhanced magnetic resonance imaging of acute reperfused myocardial injury in a cat model: part I: comparison with pathologic examination.

    abstract:RATIONALE AND OBJECTIVES:To investigate the capacity of manganese dipyridoxyl diphosphate (MnDPDP)-enhanced magnetic resonance imaging (MRI) to discriminate the injured myocardium from the normal myocardium in a cat model. MATERIALS AND METHODS:Fourteen cats were prepared for acute myocardial infarction with 90-minute...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:

    authors: Kim TH,Yang DH,Choi JW,Kim ST,Yoon JH,Shin JH,Seo JB,Gong GY,Lim TH

    更新日期:2005-01-01 00:00:00

  • Observer variation in detecting the radiologic features associated with bronchiolitis.

    abstract::Chest radiographs are commonly obtained to assess children for bronchiolitis, both to corroborate the diagnosis and to exclude other diagnostic possibilities. Their utility in this setting has not previously been examined. Using a blinded, randomized study design, we examined the interobserver and intraobserver variat...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199102000-00004

    authors: Coblentz CL,Babcook CJ,Alton D,Riley BJ,Norman G

    更新日期:1991-02-01 00:00:00

  • Activities of the Conjoint Committee. Enhancement of diagnostic radiologic research and education.

    abstract::Even though we have made much progress over the last decade, much still needs to be done. I am personally very pleased with the excellent management and authority of my coauthor, Joe Frank, in assuming the Acting Directorship of our DRRP. You will be hearing more from him in the immediate future about this research pr...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199304001-00014

    authors: Putman CE,Frank JA

    更新日期:1993-04-01 00:00:00

  • Interventional atrioseptostomy by application of monopolar high-frequency alternating current. In vitro evaluation of a new device.

    abstract:RATIONALE AND OBJECTIVES:The authors evaluate the use of a new device for interventional creation of atrial septal defects (ASD) working with high-frequency alternating current in an in vitro study with porcine atria. METHODS:The device consists of a symmetrical cage of six superelastic monofile wires, including a mic...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199702000-00003

    authors: Grabitz RG,Handt S,Vanopbroeke HJ,Seghaye MC,Franke A,Osypka P,von Bernuth G

    更新日期:1997-02-01 00:00:00

  • The effect of verification on the assessment of imaging techniques.

    abstract::In order to measure the accuracy of a diagnostic imaging technique, the correctness of each observer decision must be determined. This is often difficult in clinical cases, and various strategies are frequently used to approximate the truth. Experiments using chest radiographs as an example are reported to show the pi...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198303000-00018

    authors: Revesz G,Kundel HL,Bonitatibus M

    更新日期:1983-03-01 00:00:00

  • Technical feasibility and performance studies of a 0.009-inch nitinol microguidewire for potential neuroendovascular applications.

    abstract:RATIONALE AND OBJECTIVES:The authors conduct technical feasibility and performance studies on a new 0.009-inch nitinol microguidewire for potential neuroendovascular applications. METHODS:In vivo microcatheterizations of brachiocephalic arteries were performed in four pigs using the 0.009-inch nitinol microguidewire w...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199704000-00008

    authors: Putman CM,Chaloupka JC,Kailasnath P,Alderman J

    更新日期:1997-04-01 00:00:00

  • New contrast media in cerebral angiography: animal experiments and preliminary clinical studies.

    abstract::The cerebrovascular toxicity of three water-soluble contrast agents with a low hypertonicity (metrizamide, ioxaglate, iopamidol) was tested. Blood-brain barrier damage after carotid injection was assessed using 32P autoradiography and fluorescent microscopy after Evans blue staining. The damage to carotid endothelium ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198011001-00058

    authors: Gonsette RE,Liesenborgh L

    更新日期:1980-11-01 00:00:00

  • Gadobutrol-enhanced, three-dimensional, dynamic MR imaging with MR cholangiography for the preoperative evaluation of bile duct cancer.

    abstract:PURPOSE:To evaluate the diagnostic performance of 1.0-M gadobutrol-enhanced, 3-dimensional (3D), dynamic MR images with 3D-MR cholangiography (MRC) in the preoperative evaluation of bile duct cancer staging and resectability. MATERIALS AND METHODS:Our institutional review board approved this retrospective study. Sixty...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e3181d2eeb1

    authors: Ryoo I,Lee JM,Chung YE,Park HS,Kim SH,Han JK,Choi BI

    更新日期:2010-04-01 00:00:00

  • Ioversol clinical safety summary.

    abstract::The authors evaluated double-blind comparative and open-label clinical trials in 1,186 patients who received ioversol to evaluate the safety and efficacy of ioversol, a new nonionic low-osmolality contrast medium, at iodine concentrations of 32%, 24%, and 16%. The results indicate that ioversol was well tolerated in a...

    journal_title:Investigative radiology

    pub_type: 临床试验,杂志文章

    doi:10.1097/00004424-198906001-00020

    authors: Benamor M,Aten EM,McElvany KD,Lankin DG,James MA,Buy-Gandal T,Harashe LT,Weinandt WJ

    更新日期:1989-06-01 00:00:00

  • The use of continuous and discrete confidence judgments in receiver operating characteristic studies of diagnostic imaging techniques.

    abstract::Virtually all receiver operating characteristic (ROC) studies of medical imaging methods have involved data collected on a discrete confidence-rating scale, though in principle ROC studies can be conducted with either discrete or continuous scales. Continuous scales provide potential advantages in medical applications...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199202000-00016

    authors: Rockette HE,Gur D,Metz CE

    更新日期:1992-02-01 00:00:00

  • Intrapulmonary 3He gas distribution depending on bolus size and temporal bolus placement.

    abstract:OBJECTIVE:Dynamic ventilation (3)He-MRI is a new method to assess pulmonary gas inflow. As differing airway diameters throughout the ventilatory cycle can influence gas inflow this study intends to investigate the influence of volume and timing of a He gas bolus with respect to the beginning of the tidal volume on insp...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e3181690111

    authors: Gast KK,Hawig K,Windirsch M,Markstaller K,Schreiber WG,Schmiedeskamp J,Düber C,Kauczor HU,Heussel CP

    更新日期:2008-06-01 00:00:00

  • Pulmonary microangiography. A comparison of in vitro versus in vivo perfusion techniques in dogs.

    abstract::Because of a need to correlate pulmonary microvascular changes with physiologic data during lung injury, in vitro and in vivo pulmonary capillary microangiography was performed on normal dogs and those subjected to oleic acid injury and glass bead microembolization. During these studies, no significant differences wer...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:

    authors: Clark RL,Friedman M,Kwock L,Zaremba J

    更新日期:1983-01-01 00:00:00

  • Microcomputer-based technique for 3-D reconstruction and volume measurement of computer tomographic images. Part 1: Phantom studies.

    abstract::This paper presents a microcomputer-based technique that accurately quantifies volumes from computed tomographic (CT) scans of irregularly shaped objects as well as displaying 3-D reconstructions. The method uses standard CT film, allowing analysis of previous or outside CT studies. The planimetry method showed less t...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198812000-00001

    authors: Albright RE Jr,Fram EK

    更新日期:1988-12-01 00:00:00

  • Quantitative computed tomography of the lungs and airways in healthy nonsmoking adults.

    abstract:OBJECTIVES:The purposes of this study were to evaluate the reference range of quantitative computed tomography (QCT) measures of lung attenuation and airway parameter measurements in healthy nonsmoking adults and to identify sources of variation in those measures and possible means to adjust for them. MATERIALS AND ME...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e318262292e

    authors: Zach JA,Newell JD Jr,Schroeder J,Murphy JR,Curran-Everett D,Hoffman EA,Westgate PM,Han MK,Silverman EK,Crapo JD,Lynch DA,COPDGene Investigators.

    更新日期:2012-10-01 00:00:00

  • Dual-Energy Computed Tomography-Based Display of Bone Marrow Edema in Incidental Vertebral Compression Fractures: Diagnostic Accuracy and Characterization in Oncological Patients Undergoing Routine Staging Computed Tomography.

    abstract:PURPOSE:The aim of this study was to evaluate the diagnostic performance of virtual noncalcium (VNCa) dual-energy computed tomography (DECT) reconstructions enabling visualization of bone marrow edema for characterization of incidental thoracolumbar compression fractures in routine thoracoabdominal staging computed tom...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000458

    authors: Frellesen C,Azadegan M,Martin SS,Otani K,DʼAngelo T,Booz C,Eichler K,Panahi B,Kaup M,Bauer RW,Vogl TJ,Wichmann JL

    更新日期:2018-07-01 00:00:00