Abstract:
:The cerebrovascular toxicity of three water-soluble contrast agents with a low hypertonicity (metrizamide, ioxaglate, iopamidol) was tested. Blood-brain barrier damage after carotid injection was assessed using 32P autoradiography and fluorescent microscopy after Evans blue staining. The damage to carotid endothelium was determined using a silver staining method. Brain tissue was studied by light and electron microscopy. The studied contrast media did not damage either the blood-brain barrier or the carotid endothelium at clinical doses. Nonionic metrizamide and iopamidol have a very low brain tissue toxicity. Preliminary clinical experience indicates that the incidence of adverse reactions (pain, feeling of heat) is low. No severe adverse reactions were observed. No improvement of the radiologic information compared with the current contrast agents was observed.
journal_name
Invest Radioljournal_title
Investigative radiologyauthors
Gonsette RE,Liesenborgh Ldoi
10.1097/00004424-198011001-00058subject
Has Abstractpub_date
1980-11-01 00:00:00pages
S270-4issue
6 Suppleissn
0020-9996issn
1536-0210journal_volume
15pub_type
杂志文章abstract:OBJECTIVES:Imaging of the kidney using blood oxygen level dependent MR presents a major opportunity to examine differences in tissue oxygenation within the cortex and medulla applicable to human disease. We sought to define the differences between regions within kidneys and to optimize selection of regions of interest ...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0b013e3181b4c1e8
更新日期:2009-09-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:The authors detect activation in the auditory cortex during cochlear electrical stimulation in deaf patients using functional magnetic resonance (MR) imaging. METHODS:Stimulating electrode was inserted gently under local anesthesia close to the round window membrane of the cochlea in seven coc...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199705000-00007
更新日期:1997-05-01 00:00:00
abstract::Observer performance in radiologic interpretation has traditionally been based upon Receiver Operating Characteristic (ROC) analysis. A statistical method that evaluates the reproducibility or consistency of radiologic interpretation is presented. Since this method is not based upon pathologic verification, it cannot ...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198411000-00024
更新日期:1984-11-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:Low-field magnetic resonance imaging (MRI) evaluation of breast implants is described, with emphasis on the capabilities provided by different imaging sequences. METHODS:Open architecture MR images using a .064-T permanent magnet and three-dimensional Fourier transform and inversion recovery s...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199408000-00009
更新日期:1994-08-01 00:00:00
abstract::Erythrocytes at various concentrations were examined with a sensitive A-mode ultrasonic scanner; simultaneous measurements were made under light microscopic control. Individual erythrocytes caused weak (about 1 dB) echoes while erythrocyte aggregates (ten to 100 cells) produced stronger echoes (up to 15 dB), grossly p...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198508000-00014
更新日期:1985-08-01 00:00:00
abstract::Recent publications of the magnetic resonance safety profile of neurostimulators, cardiac pacemakers, and other implanted devices imply that these devices are no longer a contraindication for magnetic resonance imaging. It is very promising that patients who have these implanted devices may in the future no longer be ...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/01.rli.0000185898.59140.91
更新日期:2005-12-01 00:00:00
abstract:OBJECTIVES:The aim of this work was to quantitatively evaluate the pharmacokinetic pattern of Gd-EOB-DTPA in a model of isolated and perfused mouse liver by using magnetic resonance imaging (MRI) and monochromatic quantitative computed tomography (MQCT). MATERIALS AND METHODS:For MQCT, perfusions were realized with th...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/01.rli.0000174474.43772.58
更新日期:2005-09-01 00:00:00
abstract:OBJECTIVE:To assess prospectively, in healthy subjects and in patients with dilated cardiomyopathy (DCM) and hypertrophic obstructive cardiomyopathy (HOCM), the 3-dimensional (3D) shape, size, and motion of the mitral annulus (MA) using computed tomography (CT). MATERIALS AND METHODS:Twenty patients with no cardiac ab...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0b013e3181994a73
更新日期:2009-04-01 00:00:00
abstract::The hardcopy recording technologies of video cameras, slow-scan (digital spot) recorders, and laser film printers are presented and compared. Slow-scan (digital spot) recorders offer a few advantages when compared with multiformat video cameras. But only laser film printers provide the high-quality hardcopy recordings...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199102000-00017
更新日期:1991-02-01 00:00:00
abstract::A silicone gel phantom material is described. It can be molded into any shape and it can contain internal cavities. The material is selfsealing allowing the cavities to be filled with liquids. A simple geometric phantom consisting of a rectangular solid with a single internal spherical cavity was fabricated and imaged...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198702000-00013
更新日期:1987-02-01 00:00:00
abstract:OBJECTIVES:The objectives of this study were to assess the feasibility of magnetic resonance cholangiography (MRC) using biliary-secreted gadoxetic acid at 7 T and to compare it with T2-weighted (w) MRC at 3 T. MATERIALS AND METHODS:Ten healthy volunteers were examined on a 7-T whole-body magnetic resonance system. T2...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0000000000000004
更新日期:2014-05-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:The authors synthesized and tested a novel hydrogel system proposed for use in extra- and intravascular radiologic interventions, such as chemoembolizations and embolizations, and as a vehicle for sustained drug release. MATERIALS:The material was specifically designed to meet the prerequisite...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199312000-00001
更新日期:1993-12-01 00:00:00
abstract::Because of relatively low acute toxicity, iosulamide meglumine has been recommended as an improved contrast material for intravenous cholangiography. It has been postulated that high doses of the compound could be given safely with the expectation of achieving greater biliary excretion and improved opacification of th...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198105000-00016
更新日期:1981-05-01 00:00:00
abstract::Thromboembolic complications occurring during angiography may result from a number of different causes. Catheters and guidewires can interact with blood to form thrombi; this tendency is related to wall defects and the chemical composition and structural characteristics of the catheters and guidewires. Nonthrombic sou...
journal_title:Investigative radiology
pub_type: 杂志文章,评审
doi:10.1097/00004424-198811002-00009
更新日期:1988-11-01 00:00:00
abstract:PURPOSE:Magnetic Resonance Imaging (MRI) has become the method of choice in the evaluation of patients with suspected cervical artery dissection (CAD). However, reliable identification of acute CAD might be impaired by the limited spatial resolution of standard 1.5 T MRI. In this preliminary study, we implemented a mul...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/01.rli.0000195836.57778.1f
更新日期:2006-02-01 00:00:00
abstract::Polylysine covalently linked to moieties of gadopentetate (Gd-DTPA), for use as a macromolecular blood pool marker for contrast material-enhanced magnetic resonance imaging (MRI), was characterized by means of physicochemical measurements and pharmacokinetics in rats and rabbits and compared with Gd-DTPA. Gd-DTPA-poly...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199111000-00008
更新日期:1991-11-01 00:00:00
abstract::This article reviews the computer system hardware and software, applications programs, and computer network services that are available on microcomputers for use by the radiologist. The American College of Radiology Institute computer network is described, which is specifically designed to help the practicing radiolog...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198602000-00015
更新日期:1986-02-01 00:00:00
abstract::The retropsoas recess, a previously undescribed normal anatomic variant, is reported. In most individuals, the space posterior to the belly of the psoas muscle contains fat within the posterior pararenal space. However, a retrospective review of 250 consecutive CT examinations of the abdomen revealed 11 cases (4.4%) i...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198707000-00004
更新日期:1987-07-01 00:00:00
abstract::Experimental pulmonary arteritis was produced in rabbits by intravenous injection of alveolar macrophages from donor rabbits. These animals, along with matched controls, were studied with pulmonary angiography to test the hypothesis that angiography could detect the vasculitic process in life. The animals were then sa...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198007000-00005
更新日期:1980-07-01 00:00:00
abstract::In order to measure the accuracy of a diagnostic imaging technique, the correctness of each observer decision must be determined. This is often difficult in clinical cases, and various strategies are frequently used to approximate the truth. Experiments using chest radiographs as an example are reported to show the pi...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198303000-00018
更新日期:1983-03-01 00:00:00
abstract:PURPOSE:The aim of this study was to determine to what degree current compressed sensing methods are capable of accelerating clinical magnetic resonance neuroimaging sequences. METHODS:Two 2-dimensional clinical sequences were chosen for this study because of their long scan times. A pilot study was used to establish ...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0b013e31828a012d
更新日期:2013-09-01 00:00:00
abstract:OBJECTIVES:To test the feasibility of combining inner-volume imaging (IVI) techniques with conventional multishot periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER) techniques for targeted-PROPELLER magnetic resonance imaging. MATERIALS AND METHODS:Perpendicular section-selective ...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0b013e3181a8b015
更新日期:2009-08-01 00:00:00
abstract::A battery of tests for toxicity assessment of new contrast media is reviewed. Cell toxicity in a protozoan culture (Blepharisma americanum); lethal dose determination in mice; EEG Spectral analysis following cisternography in rabbits; ED50 and LD50 determination by intra- and pericerebral injection in rats; intraciste...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198011001-00053
更新日期:1980-11-01 00:00:00
abstract::The density of trabecular bone in the os calcis has been measured in 321 subjects using a gamma ray scattering technique. In normal subjects it was shown that density could be predicted from body weight and age with a standard error of 5.6%. It was also shown that the dependence of density upon weight and age was the ...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198201000-00004
更新日期:1982-01-01 00:00:00
abstract:OBJECTIVES:The aim of this study was to assess quantitative ultra-high b-value (UHB) diffusion magnetic resonance imaging (MRI)-derived parameters in comparison to standard clinical apparent diffusion coefficient (SD-ADC-2b-1000, SD-ADC-2b-1500) for the prediction of clinically significant prostate cancer, defined as G...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0000000000000712
更新日期:2021-02-01 00:00:00
abstract:PURPOSE:To evaluate the dependency of tumor contrast enhancement (CE) in regard to protein-binding properties of contrast agents, using 4 different agents with a wide range of protein-binding capacities in a standardized rat brain glioma model. MATERIAL AND METHODS:Sixteen rats with implanted brain gliomas were evalua...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0b013e318191a334
更新日期:2009-02-01 00:00:00
abstract::Compounds containing mobile protons can act as contrast agents by increasing the value of the term (1/12 - 1/11). The efficiency of this method is markedly pH- and field-dependent. There are many such compounds allowing a choice to be made based on the characteristics of the tissue or organ, magnetic field strength, a...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198809001-00058
更新日期:1988-09-01 00:00:00
abstract::The issue of dechelation (transmetallation) in vivo after administration of the linear gadolinium-based contrast agents, and potential safety concerns, is considered on the basis of an extensive, focused literature review. Early indications of potential problems included the high level of excess ligand used in the for...
journal_title:Investigative radiology
pub_type: 杂志文章,评审
doi:10.1097/RLI.0000000000000507
更新日期:2018-10-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:To assess the influence of injection rates and volumes on the arrival time of contrast material (CM) in the common carotid artery, the jugular vein and the resulting arterial-venous transit time. Additionally the relationship between injection parameters and the extent of a CM plateau was evalu...
journal_title:Investigative radiology
pub_type: 临床试验,杂志文章,随机对照试验
doi:10.1097/01.rli.0000105040.40925.c8
更新日期:2004-02-01 00:00:00
abstract:PURPOSE:Detection of pulmonary metastases is still a challenging task for magnetic resonance imaging (MRI). It was the aim of this study to evaluate the potential of a free-breathing move-during-scan turbo inversion recovery magnitude sequence for the detection of pulmonary nodules. MATERIALS AND METHODS:The sensitivi...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0b013e31816901fa
更新日期:2008-06-01 00:00:00