New contrast media in cerebral angiography: animal experiments and preliminary clinical studies.

Abstract:

:The cerebrovascular toxicity of three water-soluble contrast agents with a low hypertonicity (metrizamide, ioxaglate, iopamidol) was tested. Blood-brain barrier damage after carotid injection was assessed using 32P autoradiography and fluorescent microscopy after Evans blue staining. The damage to carotid endothelium was determined using a silver staining method. Brain tissue was studied by light and electron microscopy. The studied contrast media did not damage either the blood-brain barrier or the carotid endothelium at clinical doses. Nonionic metrizamide and iopamidol have a very low brain tissue toxicity. Preliminary clinical experience indicates that the incidence of adverse reactions (pain, feeling of heat) is low. No severe adverse reactions were observed. No improvement of the radiologic information compared with the current contrast agents was observed.

journal_name

Invest Radiol

journal_title

Investigative radiology

authors

Gonsette RE,Liesenborgh L

doi

10.1097/00004424-198011001-00058

subject

Has Abstract

pub_date

1980-11-01 00:00:00

pages

S270-4

issue

6 Suppl

eissn

0020-9996

issn

1536-0210

journal_volume

15

pub_type

杂志文章
  • Comparison of 1.5 and 3 T BOLD MR to study oxygenation of kidney cortex and medulla in human renovascular disease.

    abstract:OBJECTIVES:Imaging of the kidney using blood oxygen level dependent MR presents a major opportunity to examine differences in tissue oxygenation within the cortex and medulla applicable to human disease. We sought to define the differences between regions within kidneys and to optimize selection of regions of interest ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e3181b4c1e8

    authors: Gloviczki ML,Glockner J,Gomez SI,Romero JC,Lerman LO,McKusick M,Textor SC

    更新日期:2009-09-01 00:00:00

  • Auditory cortex activation in deaf subjects during cochlear electrical stimulation. Evaluation by functional magnetic resonance imaging.

    abstract:RATIONALE AND OBJECTIVES:The authors detect activation in the auditory cortex during cochlear electrical stimulation in deaf patients using functional magnetic resonance (MR) imaging. METHODS:Stimulating electrode was inserted gently under local anesthesia close to the round window membrane of the cochlea in seven coc...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199705000-00007

    authors: Berthezène Y,Truy E,Morgon A,Giard MH,Hermier M,Franconi JM,Froment JC

    更新日期:1997-05-01 00:00:00

  • Observer variation in abdominal CT.

    abstract::Observer performance in radiologic interpretation has traditionally been based upon Receiver Operating Characteristic (ROC) analysis. A statistical method that evaluates the reproducibility or consistency of radiologic interpretation is presented. Since this method is not based upon pathologic verification, it cannot ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198411000-00024

    authors: Herman S,DeBoer G,Rideout DF,Majesky IF

    更新日期:1984-11-01 00:00:00

  • Characteristics of magnetic resonance sequences used for imaging silicone gel, saline, and gel-saline implants at low field strengths.

    abstract:RATIONALE AND OBJECTIVES:Low-field magnetic resonance imaging (MRI) evaluation of breast implants is described, with emphasis on the capabilities provided by different imaging sequences. METHODS:Open architecture MR images using a .064-T permanent magnet and three-dimensional Fourier transform and inversion recovery s...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199408000-00009

    authors: Frankel S,Occhipinti K,Kaufman L,Kramer D,Carlson J,Mineyev M,Friedenthal R

    更新日期:1994-08-01 00:00:00

  • Ultrasonic echoes registered from erythrocytes.

    abstract::Erythrocytes at various concentrations were examined with a sensitive A-mode ultrasonic scanner; simultaneous measurements were made under light microscopic control. Individual erythrocytes caused weak (about 1 dB) echoes while erythrocyte aggregates (ten to 100 cells) produced stronger echoes (up to 15 dB), grossly p...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198508000-00014

    authors: Alanen A,Kormano M

    更新日期:1985-08-01 00:00:00

  • Specific absorption rate as a poor indicator of magnetic resonance-related implant heating.

    abstract::Recent publications of the magnetic resonance safety profile of neurostimulators, cardiac pacemakers, and other implanted devices imply that these devices are no longer a contraindication for magnetic resonance imaging. It is very promising that patients who have these implanted devices may in the future no longer be ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/01.rli.0000185898.59140.91

    authors: Nitz WR,Brinker G,Diehl D,Frese G

    更新日期:2005-12-01 00:00:00

  • Evaluation of Gd-EOB-DTPA uptake in a perfused and isolated mouse liver model: correlation between magnetic resonance imaging and monochromatic quantitative computed tomography.

    abstract:OBJECTIVES:The aim of this work was to quantitatively evaluate the pharmacokinetic pattern of Gd-EOB-DTPA in a model of isolated and perfused mouse liver by using magnetic resonance imaging (MRI) and monochromatic quantitative computed tomography (MQCT). MATERIALS AND METHODS:For MQCT, perfusions were realized with th...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/01.rli.0000174474.43772.58

    authors: Segers J,Le Duc G,Laumonier C,Troprès I,Elst LV,Muller RN

    更新日期:2005-09-01 00:00:00

  • Mitral annular shape, size, and motion in normals and in patients with cardiomyopathy: evaluation with computed tomography.

    abstract:OBJECTIVE:To assess prospectively, in healthy subjects and in patients with dilated cardiomyopathy (DCM) and hypertrophic obstructive cardiomyopathy (HOCM), the 3-dimensional (3D) shape, size, and motion of the mitral annulus (MA) using computed tomography (CT). MATERIALS AND METHODS:Twenty patients with no cardiac ab...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e3181994a73

    authors: Alkadhi H,Desbiolles L,Stolzmann P,Leschka S,Scheffel H,Plass A,Schertler T,Trindade PT,Genoni M,Cattin P,Marincek B,Frauenfelder T

    更新日期:2009-04-01 00:00:00

  • Hardcopy recording technologies for digitally formatted image data.

    abstract::The hardcopy recording technologies of video cameras, slow-scan (digital spot) recorders, and laser film printers are presented and compared. Slow-scan (digital spot) recorders offer a few advantages when compared with multiformat video cameras. But only laser film printers provide the high-quality hardcopy recordings...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199102000-00017

    authors: Siegel EL,Bishop MD,Wetzel LH,Anderson WF,McMillan JH

    更新日期:1991-02-01 00:00:00

  • A silicone gel phantom suitable for multimodality imaging.

    abstract::A silicone gel phantom material is described. It can be molded into any shape and it can contain internal cavities. The material is selfsealing allowing the cavities to be filled with liquids. A simple geometric phantom consisting of a rectangular solid with a single internal spherical cavity was fabricated and imaged...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198702000-00013

    authors: Goldstein DC,Kundel HL,Daube-Witherspoon ME,Thibault LE,Goldstein EJ

    更新日期:1987-02-01 00:00:00

  • Ultrahigh-field imaging of the biliary tract at 7 T: initial results of gadoxetic acid-enhanced magnetic resonance cholangiography.

    abstract:OBJECTIVES:The objectives of this study were to assess the feasibility of magnetic resonance cholangiography (MRC) using biliary-secreted gadoxetic acid at 7 T and to compare it with T2-weighted (w) MRC at 3 T. MATERIALS AND METHODS:Ten healthy volunteers were examined on a 7-T whole-body magnetic resonance system. T2...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000004

    authors: Fischer A,Kraff O,Orzada S,Nensa F,Schäfer LC,Ladd ME,Umutlu L,Lauenstein TC

    更新日期:2014-05-01 00:00:00

  • AUR Memorial Award 1993. A drug system (PDH) for interventional radiology. Synthesis, properties, and efficacy.

    abstract:RATIONALE AND OBJECTIVES:The authors synthesized and tested a novel hydrogel system proposed for use in extra- and intravascular radiologic interventions, such as chemoembolizations and embolizations, and as a vehicle for sustained drug release. MATERIALS:The material was specifically designed to meet the prerequisite...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199312000-00001

    authors: Weissleder R,Bogdanov A,Frank H,Nossiff N,Bogdanova A,Schaffer BK,Brady T,Wittenberg J

    更新日期:1993-12-01 00:00:00

  • The potential of iosulamide meglumine as a contrast material for intravenous cholangiography: an experimental study in dogs.

    abstract::Because of relatively low acute toxicity, iosulamide meglumine has been recommended as an improved contrast material for intravenous cholangiography. It has been postulated that high doses of the compound could be given safely with the expectation of achieving greater biliary excretion and improved opacification of th...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198105000-00016

    authors: Berk RN,Barnhart JL,Nazareno G,Witt BL

    更新日期:1981-05-01 00:00:00

  • The role of catheters and guidewires in the production of angiographic thromboembolic complications.

    abstract::Thromboembolic complications occurring during angiography may result from a number of different causes. Catheters and guidewires can interact with blood to form thrombi; this tendency is related to wall defects and the chemical composition and structural characteristics of the catheters and guidewires. Nonthrombic sou...

    journal_title:Investigative radiology

    pub_type: 杂志文章,评审

    doi:10.1097/00004424-198811002-00009

    authors: Kido DK,King PD,Manzione JV,Simon JH

    更新日期:1988-11-01 00:00:00

  • Spontaneous acute dissection of the internal carotid artery: high-resolution magnetic resonance imaging at 3.0 tesla with a dedicated surface coil.

    abstract:PURPOSE:Magnetic Resonance Imaging (MRI) has become the method of choice in the evaluation of patients with suspected cervical artery dissection (CAD). However, reliable identification of acute CAD might be impaired by the limited spatial resolution of standard 1.5 T MRI. In this preliminary study, we implemented a mul...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/01.rli.0000195836.57778.1f

    authors: Bachmann R,Nassenstein I,Kooijman H,Dittrich R,Kugel H,Niederstadt T,Kuhlenbäumer G,Ringelstein EB,Krämer S,Heindel W

    更新日期:2006-02-01 00:00:00

  • In vivo and in vitro evaluation of Gd-DTPA-polylysine as a macromolecular contrast agent for magnetic resonance imaging.

    abstract::Polylysine covalently linked to moieties of gadopentetate (Gd-DTPA), for use as a macromolecular blood pool marker for contrast material-enhanced magnetic resonance imaging (MRI), was characterized by means of physicochemical measurements and pharmacokinetics in rats and rabbits and compared with Gd-DTPA. Gd-DTPA-poly...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199111000-00008

    authors: Schuhmann-Giampieri G,Schmitt-Willich H,Frenzel T,Press WR,Weinmann HJ

    更新日期:1991-11-01 00:00:00

  • Personal computer needs for the radiologist.

    abstract::This article reviews the computer system hardware and software, applications programs, and computer network services that are available on microcomputers for use by the radiologist. The American College of Radiology Institute computer network is described, which is specifically designed to help the practicing radiolog...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198602000-00015

    authors: Newell JD,Hunter TB

    更新日期:1986-02-01 00:00:00

  • The retropsoas recess. Demonstration using computed tomography.

    abstract::The retropsoas recess, a previously undescribed normal anatomic variant, is reported. In most individuals, the space posterior to the belly of the psoas muscle contains fat within the posterior pararenal space. However, a retrospective review of 250 consecutive CT examinations of the abdomen revealed 11 cases (4.4%) i...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198707000-00004

    authors: Kelly RB,Mahoney PD,Frick MP

    更新日期:1987-07-01 00:00:00

  • Experimental pulmonary arteritis.

    abstract::Experimental pulmonary arteritis was produced in rabbits by intravenous injection of alveolar macrophages from donor rabbits. These animals, along with matched controls, were studied with pulmonary angiography to test the hypothesis that angiography could detect the vasculitic process in life. The animals were then sa...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198007000-00005

    authors: Hicken P,Hogg JC,Pare PD

    更新日期:1980-07-01 00:00:00

  • The effect of verification on the assessment of imaging techniques.

    abstract::In order to measure the accuracy of a diagnostic imaging technique, the correctness of each observer decision must be determined. This is often difficult in clinical cases, and various strategies are frequently used to approximate the truth. Experiments using chest radiographs as an example are reported to show the pi...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198303000-00018

    authors: Revesz G,Kundel HL,Bonitatibus M

    更新日期:1983-03-01 00:00:00

  • Clinical image quality assessment of accelerated magnetic resonance neuroimaging using compressed sensing.

    abstract:PURPOSE:The aim of this study was to determine to what degree current compressed sensing methods are capable of accelerating clinical magnetic resonance neuroimaging sequences. METHODS:Two 2-dimensional clinical sequences were chosen for this study because of their long scan times. A pilot study was used to establish ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e31828a012d

    authors: Sharma SD,Fong CL,Tzung BS,Law M,Nayak KS

    更新日期:2013-09-01 00:00:00

  • Multishot targeted PROPELLER magnetic resonance imaging: description of the technique and initial applications.

    abstract:OBJECTIVES:To test the feasibility of combining inner-volume imaging (IVI) techniques with conventional multishot periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER) techniques for targeted-PROPELLER magnetic resonance imaging. MATERIALS AND METHODS:Perpendicular section-selective ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e3181a8b015

    authors: Deng J,Larson AC

    更新日期:2009-08-01 00:00:00

  • Combined methods for assessment of neurotoxicity: testing of new nonionic radiographic media.

    abstract::A battery of tests for toxicity assessment of new contrast media is reviewed. Cell toxicity in a protozoan culture (Blepharisma americanum); lethal dose determination in mice; EEG Spectral analysis following cisternography in rabbits; ED50 and LD50 determination by intra- and pericerebral injection in rats; intraciste...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198011001-00053

    authors: Sovak M,Siefert HM,Ranganathan R

    更新日期:1980-11-01 00:00:00

  • Photon scattering measurement of calcaneal bone density: result of in vivo cross-sectional studies.

    abstract::The density of trabecular bone in the os calcis has been measured in 321 subjects using a gamma ray scattering technique. In normal subjects it was shown that density could be predicted from body weight and age with a standard error of 5.6%. It was also shown that the dependence of density upon weight and age was the ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198201000-00004

    authors: Roberts JG,DiTomasso E,Webber CE

    更新日期:1982-01-01 00:00:00

  • Measured Multipoint Ultra-High b-Value Diffusion MRI in the Assessment of MRI-Detected Prostate Lesions.

    abstract:OBJECTIVES:The aim of this study was to assess quantitative ultra-high b-value (UHB) diffusion magnetic resonance imaging (MRI)-derived parameters in comparison to standard clinical apparent diffusion coefficient (SD-ADC-2b-1000, SD-ADC-2b-1500) for the prediction of clinically significant prostate cancer, defined as G...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000712

    authors: Tavakoli AA,Kuder TA,Tichy D,Radtke JP,Görtz M,Schütz V,Stenzinger A,Hohenfellner M,Schlemmer HP,Bonekamp D

    更新日期:2021-02-01 00:00:00

  • Brain tumor enhancement in magnetic resonance imaging: dependency on the level of protein binding of applied contrast agents.

    abstract:PURPOSE:To evaluate the dependency of tumor contrast enhancement (CE) in regard to protein-binding properties of contrast agents, using 4 different agents with a wide range of protein-binding capacities in a standardized rat brain glioma model. MATERIAL AND METHODS:Sixteen rats with implanted brain gliomas were evalua...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e318191a334

    authors: Wintersperger BJ,Runge VM,Tweedle MF,Jackson CB,Reiser MF

    更新日期:2009-02-01 00:00:00

  • A new class of contrast agents for magnetic resonance imaging based on selective reduction of water-T2 by chemical exchange.

    abstract::Compounds containing mobile protons can act as contrast agents by increasing the value of the term (1/12 - 1/11). The efficiency of this method is markedly pH- and field-dependent. There are many such compounds allowing a choice to be made based on the characteristics of the tissue or organ, magnetic field strength, a...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198809001-00058

    authors: Aime S,Nano R,Grandi M

    更新日期:1988-09-01 00:00:00

  • Dechelation (Transmetalation): Consequences and Safety Concerns With the Linear Gadolinium-Based Contrast Agents, In View of Recent Health Care Rulings by the EMA (Europe), FDA (United States), and PMDA (Japan).

    abstract::The issue of dechelation (transmetallation) in vivo after administration of the linear gadolinium-based contrast agents, and potential safety concerns, is considered on the basis of an extensive, focused literature review. Early indications of potential problems included the high level of excess ligand used in the for...

    journal_title:Investigative radiology

    pub_type: 杂志文章,评审

    doi:10.1097/RLI.0000000000000507

    authors: Runge VM

    更新日期:2018-10-01 00:00:00

  • Contrast-enhanced magnetic resonance angiography of the carotid arteries: influence of injection rates and volumes on arterial-venous transit time.

    abstract:RATIONALE AND OBJECTIVES:To assess the influence of injection rates and volumes on the arrival time of contrast material (CM) in the common carotid artery, the jugular vein and the resulting arterial-venous transit time. Additionally the relationship between injection parameters and the extent of a CM plateau was evalu...

    journal_title:Investigative radiology

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1097/01.rli.0000105040.40925.c8

    authors: Herold T,Paetzel C,Völk M,Bachthaler M,Zorger N,Feuerbach S,Strotzer M,Lenhart M

    更新日期:2004-02-01 00:00:00

  • Detection of pulmonary nodules with move-during-scan magnetic resonance imaging using a free-breathing turbo inversion recovery magnitude sequence.

    abstract:PURPOSE:Detection of pulmonary metastases is still a challenging task for magnetic resonance imaging (MRI). It was the aim of this study to evaluate the potential of a free-breathing move-during-scan turbo inversion recovery magnitude sequence for the detection of pulmonary nodules. MATERIALS AND METHODS:The sensitivi...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e31816901fa

    authors: Baumann T,Ludwig U,Pache G,Gall C,Saueressig U,Fisch D,Stankovic Z,Bartholomae JP,Honal M,Bley TA,Langer M,Schaefer O

    更新日期:2008-06-01 00:00:00