The potential of iosulamide meglumine as a contrast material for intravenous cholangiography: an experimental study in dogs.

Abstract:

:Because of relatively low acute toxicity, iosulamide meglumine has been recommended as an improved contrast material for intravenous cholangiography. It has been postulated that high doses of the compound could be given safely with the expectation of achieving greater biliary excretion and improved opacification of the biliary tree. Experiments performed in dogs show that higher rates of infusion of iosulamide result in greater urinary elimination without additional biliary excretion. Consequently, iosulamide is unlikely to have any special advantage as a contrast agent.

journal_name

Invest Radiol

journal_title

Investigative radiology

authors

Berk RN,Barnhart JL,Nazareno G,Witt BL

doi

10.1097/00004424-198105000-00016

subject

Has Abstract

pub_date

1981-05-01 00:00:00

pages

240-4

issue

3

eissn

0020-9996

issn

1536-0210

journal_volume

16

pub_type

杂志文章
  • Sequential change of MR signal intensity of the brain after manganese administration in rabbits. Correlation with manganese concentration and histopathologic findings.

    abstract:RATIONALE AND OBJECTIVES:High signal intensity in the basal ganglia on T1-weighted MR imaging has been reported in chronic manganese (Mn) poisoning. However, the exact meaning of the high signal intensity remains unclear: does it result from Mn itself, secondary pathologic changes of the brain tissue, or both? The goal...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199906000-00001

    authors: Kim SH,Chang KH,Chi JG,Cheong HK,Kim JY,Kim YM,Han MH

    更新日期:1999-06-01 00:00:00

  • Curriculum for musculoskeletal radiology.

    abstract::Although general suggestions have been made regarding a radiology residency curriculum, no specific list of entities has been offered. Over the past ten years, we have developed a resident-run morning conference in musculoskeletal radiology that is supervised by faculty and covers a specific curriculum. We offer our c...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199111000-00019

    authors: Renfrew DL,el-Khoury GY,Moore TE,Kathol MH,Whitten CG,Walker CW,Fraser-Hill MA

    更新日期:1991-11-01 00:00:00

  • Noninvasive quantification of hepatic fat content using three-echo dixon magnetic resonance imaging with correction for T2* relaxation effects.

    abstract:OBJECTIVE:To investigate three-echo T2*-corrected Dixon magnetic resonance imaging (MRI) for noninvasively estimating hepatic fat content (HFC) compared with biopsy. MATERIALS AND METHODS:One hundred patients (50 men, 50 women; mean age, 57.7±14.2 years) underwent clinically indicated liver core biopsy (102 valid tiss...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e31822b124c

    authors: Kühn JP,Evert M,Friedrich N,Kannengiesser S,Mayerle J,Thiel R,Lerch MM,Dombrowski F,Mensel B,Hosten N,Puls R

    更新日期:2011-12-01 00:00:00

  • Dose response to Paclitaxel-coated balloon catheters in the porcine coronary overstretch and stent implantation model.

    abstract:OBJECTIVE:There is little published information regarding the efficacy of paclitaxel-coated balloon catheters except for the iopromide-containing formulation, and less is known about the kind of toxicity at overdose. The aim of our study was to assess 2 different paclitaxel matrix formulations on angioplasty balloon ca...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e31820577df

    authors: Kelsch B,Scheller B,Biedermann M,Clever YP,Schaffner S,Mahnkopf D,Speck U,Cremers B

    更新日期:2011-04-01 00:00:00

  • Pharmacokinetics and safety of gadobutrol-enhanced magnetic resonance imaging in pediatric patients.

    abstract:OBJECTIVES:This clinical study investigated the pharmacokinetics and safety of gadobutrol, a magnetic resonance (MR) imaging extracellular contrast agent, in pediatric patients aged 2 to 17 years. MATERIALS AND METHODS:In this open-label, multicenter study, patients scheduled for routine contrast-enhanced MR imaging o...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e3181bfe2d2

    authors: Hahn G,Sorge I,Gruhn B,Glutig K,Hirsch W,Bhargava R,Furtner J,Born M,Schröder C,Ahlström H,Kaiser S,Moritz JD,Kunze CW,Shroff M,Stokland E,Trnkova ZJ,Schultze-Mosgau M,Reif S,Bacher-Stier C,Mentzel HJ

    更新日期:2009-12-01 00:00:00

  • Interference of gadolinium-containing contrast-enhancing agents with colorimetric calcium laboratory testing.

    abstract:OBJECTIVES:The purpose of this study was to evaluate the extent to which various commercially available gadolinium-containing contrast-enhancing (CE) agents can interfere with the measurement of calcium levels by currently used laboratory methods, suggesting (spurious) hypocalcemia or hypercalcemia with a potential ris...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/01.rli.0000170447.45577.5e

    authors: Löwe A,Balzer T,Hirt U

    更新日期:2005-08-01 00:00:00

  • Short-term effects of a new intravascular nitinol stent in canine arteries.

    abstract:RATIONALE AND OBJECTIVES:To evaluate the short-term effects of a new nitinol stent on canine arteries. METHODS:Eighteen nitinol mesh stents were placed in abdominal aortas, common iliac arteries, and renal arteries of six dogs. Angiography was performed to evaluate the patency rates and structural changes of arteries ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199905000-00007

    authors: Lee KW,Park JH,Chung JW,Kim WS,Lee W,Yeon KM

    更新日期:1999-05-01 00:00:00

  • Image mottle in abdominal CT.

    abstract:RATIONALE AND OBJECTIVES:To investigate image mottle in conventional CT images of the abdomen as a function of radiographic technique factors and patient size. METHODS:Water-filled phantoms simulating the abdomens of adult (32 cm in diameter) and pediatric (16 cm in diameter) patients were used to investigate image mo...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199904000-00005

    authors: Ende JF,Huda W,Ros PR,Litwiller AL

    更新日期:1999-04-01 00:00:00

  • A new animal model for testing renal tolerance of contrast agents.

    abstract:RATIONALE AND OBJECTIVES:To develop a new animal model for the evaluation of the renal tolerance of contrast agent and its application to diatrizoate and iotrolan injections in comparison to saline and mannitol solution. MATERIALS AND METHODS:The nephrotoxic potential of intravenously injected contrast agents in Beagl...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/01.rli.0000087096.61127.13

    authors: Krause W,Gilles T

    更新日期:2003-11-01 00:00:00

  • A direct comparison of noninvasive coronary angiography by electron beam tomography and navigator-echo-based magnetic resonance imaging for the detection of restenosis following coronary angioplasty.

    abstract:RATIONALE AND OBJECTIVES:To compare electron beam tomography (EBT) with MR imaging (MRI) for detection of restenosis after coronary angioplasty (PTCA). METHODS:One hundred eighteen patients after PTCA were investigated. By EBT, 50 axial images were acquired (3-mm slice thickness, 120-160 mL radiographic contrast agent...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-200207000-00005

    authors: Ropers D,Regenfus M,Stilianakis N,Birke S,Kessler W,Moshage W,Laub G,Daniel WG,Achenbach S

    更新日期:2002-07-01 00:00:00

  • Terbutaline in diagnosis of interstitial fallopian tube obstruction.

    abstract::Effectiveness of terbutaline, a potent uterine muscle relaxant, for differentiation of temporary and anatomic interstitial fallopian tube obstruction (IFTO) at hysterosalpingography (HSG) was explored. In 43 IFTO evaluated, HSG after terbutaline showed patency in only one of 16 tubes in which IFTO was caused by spasm ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198803000-00010

    authors: Thurmond AS,Novy M,Rösch J

    更新日期:1988-03-01 00:00:00

  • Pediatric angiocardiography with iohexol.

    abstract::A nonionic contrast medium (iohexol) was evaluated for safety and efficacy in pediatric angiocardiography in this study of 15 patients, age 6 to 82 months. Patients carried a preliminary diagnosis of congenital heart disease. Subjects were injected with iohexol, 350 mg iodine/ml of solution with an average volume of 2...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:

    authors: Carlsson EC,Rudolph A,Stanger P,Teitel D,Weber W,Yoshida H

    更新日期:1985-01-01 00:00:00

  • Preliminary evaluation of Hexabrix for temporomandibular joint arthrography.

    abstract::A double-blind randomized study of ten patients compared Hexabrix 32% to Renografin-60 in TMJ arthrography. Equivalent volumes of contrast material were injected under fluoroscopic observation, with film quality and patient subjective response graded independently by three radiologists. In immediate arthrogram quality...

    journal_title:Investigative radiology

    pub_type: 临床试验,杂志文章

    doi:10.1097/00004424-198411001-00032

    authors: Katzberg RW

    更新日期:1984-11-01 00:00:00

  • Pediatric Brain: Gadolinium Deposition in Dentate Nucleus and Globus Pallidus on Unenhanced T1-Weighted Images Is Dependent on the Type of Contrast Agent.

    abstract:PURPOSE:The aim of this study was to identify the signal intensity (SI) changes in the dentate nucleus (DN) and the globus pallidus (GP) on unenhanced T1-weighted magnetic resonance (MR) images after multiple administration of gadolinium-based contrast agents (GBCAs) in children and compare those changes between linear...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000436

    authors: Ryu YJ,Choi YH,Cheon JE,Lee WJ,Park S,Park JE,Kim WS,Kim IO

    更新日期:2018-04-01 00:00:00

  • Potential of dose reduction after marker placement with full-field digital mammography.

    abstract:OBJECTIVES:The purpose of our study was to assess the potential for radiation dose reduction in digital postinterventional digital mammograms after marker placement. MATERIALS AND METHODS:One hundred consecutive cases of marker placement (hook-wire localization or postbiopsy clip marker placement), with 200 full-field...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/01.rli.0000163743.63063.9f

    authors: Riedl CC,Jaromi S,Floery D,Pfarl G,Fuchsjaeger MH,Helbich TH

    更新日期:2005-06-01 00:00:00

  • Heavily Calcified Coronary Arteries: Advanced Calcium Subtraction Improves Luminal Visualization and Diagnostic Confidence in Dual-Energy Coronary Computed Tomography Angiography.

    abstract:OBJECTIVES:The aim of this study was to evaluate a prototype dual-energy computed tomography calcium subtraction algorithm and its impact on luminal visualization in patients with heavily calcified coronary arteries. MATERIALS AND METHODS:Twenty-nine patients (62% male; mean age, 64 ± 7 years) who had undergone dual-e...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000416

    authors: De Santis D,Jin KN,Schoepf UJ,Grant KL,De Cecco CN,Nance JW Jr,Vogl TJ,Laghi A,Albrecht MH

    更新日期:2018-02-01 00:00:00

  • Contrast gradient and the detection of lung nodules.

    abstract::The effects of edge gradient and blur on the detection pulmonary nodules were studied, using a test series of 175 artificial nodules on 30 chest films. The nodules were of homogeneous texture, about 1 cm in diameter and had a mean contrast of .12. Six observers viewed the film set, scoring both location and confidence...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-197901000-00004

    authors: Kundel HL,Revesz G,Toto L

    更新日期:1979-01-01 00:00:00

  • Effect of additional cations on the twitching reaction to intracarotid, nonionic contrast media in rabbits.

    abstract::Previous investigations in this laboratory have confirmed the observation of facial muscle twitching during intracarotid injections of nonionic contrast media (CM) in rabbits. The reaction appears to be a locally mediated effect. To further investigate this reaction, cortical electroencephalogram (EEG) and facial elec...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199009000-00010

    authors: Whisson CC,Evill CA,Sage MR,Wilson AJ

    更新日期:1990-09-01 00:00:00

  • Evaluation of Gd-EOB-DTPA uptake in a perfused and isolated mouse liver model: correlation between magnetic resonance imaging and monochromatic quantitative computed tomography.

    abstract:OBJECTIVES:The aim of this work was to quantitatively evaluate the pharmacokinetic pattern of Gd-EOB-DTPA in a model of isolated and perfused mouse liver by using magnetic resonance imaging (MRI) and monochromatic quantitative computed tomography (MQCT). MATERIALS AND METHODS:For MQCT, perfusions were realized with th...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/01.rli.0000174474.43772.58

    authors: Segers J,Le Duc G,Laumonier C,Troprès I,Elst LV,Muller RN

    更新日期:2005-09-01 00:00:00

  • High-resolution magnetic resonance imaging at 2 Tesla: potential for atherosclerotic lesions exploration in the apolipoprotein E knockout mouse.

    abstract:INTRODUCTION:The aim of the present study was to evaluate the potential of high-resolution MRI at 2 Tesla (T) for direct noninvasive imaging of the aortic wall in a mouse model of atherosclerosis. MATERIAL AND METHODS:A specific mouse antenna was developed and sequence parameters were adjusted. T(1)- and T2-weighted i...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/01.rli.0000067491.31978.1c

    authors: Chaabane L,Soulas EC,Contard F,Salah A,Guerrier D,Briguet A,Douek P

    更新日期:2003-08-01 00:00:00

  • Hepatic parenchymal changes after the intraarterial injection of lipiodol in tumor-bearing rabbits.

    abstract:RATIONALE AND OBJECTIVES:The influence of lipiodol injection on hepatic morphology and function was investigated in 119 rabbits with hepatic VX2 tumors. METHODS:The rabbits were divided into the following three groups, according to the materials injected via the proper hepatic artery: group 1 received doxorubicin (Adr...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199302000-00009

    authors: Akashi Y,Koreeda C,Mizuno T,Inoue K,Kawa SK,Tanaka Y

    更新日期:1993-02-01 00:00:00

  • Protective effects of corticosteroids in contrast material anaphylaxis.

    abstract::A prospective, randomized study of the potential protective effects of corticosteroids administered as pretreatment against contrast material (CM) reactions is reported. Patients (n = 6,763) from multiple institutions received either a single dose of steroids (32 mg of oral methylprednisolone, approximately 2 hours be...

    journal_title:Investigative radiology

    pub_type: 临床试验,杂志文章,多中心研究,随机对照试验

    doi:10.1097/00004424-198809001-00035

    authors: Lasser EC,Berry CC,Talner LB,Santini LC,Lang EK,Gerber FH,Stolberg HO

    更新日期:1988-09-01 00:00:00

  • Applications of voxel shifting in magnetic resonance imaging.

    abstract::Due to the nature of three-dimensional Fourier transform (3-DFT) data acquisition in magnetic resonance imaging (MRI), the spatial relation between a resolved volume element (a voxel) and the object can be manipulated easily. Those manipulations have practical consequences in terms of registering slice positions with ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199012000-00006

    authors: Kramer D,Li A,Simovsky I,Hawryszko C,Hale J,Kaufman L

    更新日期:1990-12-01 00:00:00

  • Design of an isolated pig heart preparation for positron emission tomography and magnetic resonance imaging.

    abstract:RATIONALE AND OBJECTIVES:Validation of new positron emission tomography (PET) tracers or magnetic (MR) imaging contrast agents is based on isolated rodent heart preparations. The use of larger animals could provide a more direct validation using the devices used for humans. METHODS:An isolated pig heart preparation ha...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199711000-00010

    authors: Casali C,Obadia JF,Canet E,Bendjelid K,André-Fouët X,Revel D,Janier MF

    更新日期:1997-11-01 00:00:00

  • Low-Dose Characterization of Kidney Stones Using Spectral Detector Computed Tomography: An Ex Vivo Study.

    abstract:OBJECTIVES:The aim of this study was to investigate the feasibility of kidney stone composition analysis using spectral detector computed tomography scanner (SDCT) with normal- and low-dose imaging protocols. METHODS:A total of 154 stones harvested from nephrolithotripsy or nephrolithotomy with a known monocrystalline...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000468

    authors: Große Hokamp N,Salem J,Hesse A,Holz JA,Ritter M,Heidenreich A,Maintz D,Haneder S

    更新日期:2018-08-01 00:00:00

  • D-galactose-based signal-enhanced color Doppler sonography of breast tumors and tumorlike lesions.

    abstract:RATIONALE AND OBJECTIVES:This study sought to evaluate prospectively the diagnostic potential of unenhanced and enhanced color Doppler and power Doppler for the differentiation of tumors and tumorlike lesions of the breast. METHODS:Ninety-two patients with 110 tumors or tumorlike lesions of the breast were investigate...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199902000-00003

    authors: Schroeder RJ,Maeurer J,Vogl TJ,Hidajat N,Hadijuana J,Venz S,Weber S,Felix R

    更新日期:1999-02-01 00:00:00

  • The effects of radiographic contrast media on myocardial contractility and coronary resistance: osmolality, ionic concentration, and viscosity.

    abstract::With the ongoing development of new contrast agents, questions develop concerning the cardiac effects of these drugs. We used the perfused rat heart model to investigate the effects on cardiac and coronary function of hypertonic ionic (sodium chloride) and nonionic (glucose) solutions and conventional and low osmolali...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199003000-00009

    authors: Fleetwood G,Bettmann MA,Gordon JL

    更新日期:1990-03-01 00:00:00

  • Radiologic-pathologic-clinical correlation in mechanisms of disease course.

    abstract::The interdisciplinary approach to medical education has often been deficient in medical school curricula. Because of the nonintegrated approach to medical education, problem solving capabilities are not fostered. The clinical presentation of a patient, the imaging modalities used to investigate the patient, and the ul...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198604000-00015

    authors: Oldham SA,Jacobson F

    更新日期:1986-04-01 00:00:00

  • Ultrasound bone velocity on proximal phalanges in premenopausal, perimenopausal, and postmenopausal healthy women.

    abstract:RATIONALE AND OBJECTIVES:The authors studied premenopausal, perimenopausal, and postmenopausal women to determine if ultrasound bone velocity (UBV) on proximal phalanges of women reflect bone changes related to gonadal status and age. METHODS:A total of 166 healthy women-64 postmenopausal women (mean age 58.7 +/- 9.4 ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199701000-00011

    authors: Aguado F,Revilla M,Hernández ER,Villa LF,Rico H

    更新日期:1997-01-01 00:00:00

  • Detection of emphysema with computed tomography. Correlation with pulmonary function tests and chest radiography.

    abstract::We studied 60 male patients who had concurrent chest films (CXR), computed tomography scans (CT) and pulmonary function tests (PFT) to assess the sensitivity of CT and conventional films in detecting emphysema compared with PFT. We also sought to determine whether emphysema could be diagnosed by CT in patients with no...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198804000-00004

    authors: Sanders C,Nath PH,Bailey WC

    更新日期:1988-04-01 00:00:00