Hardcopy recording technologies for digitally formatted image data.

Abstract:

:The hardcopy recording technologies of video cameras, slow-scan (digital spot) recorders, and laser film printers are presented and compared. Slow-scan (digital spot) recorders offer a few advantages when compared with multiformat video cameras. But only laser film printers provide the high-quality hardcopy recordings and speed required by newer digital imaging modalities.

journal_name

Invest Radiol

journal_title

Investigative radiology

authors

Siegel EL,Bishop MD,Wetzel LH,Anderson WF,McMillan JH

doi

10.1097/00004424-199102000-00017

subject

Has Abstract

pub_date

1991-02-01 00:00:00

pages

179-83

issue

2

eissn

0020-9996

issn

1536-0210

journal_volume

26

pub_type

杂志文章
  • Some practical issues of experimental design and data analysis in radiological ROC studies.

    abstract::Receiver operating characteristic (ROC) analysis has been used in a broad variety of medical imaging studies during the past 15 years, and its advantages over more traditional measures of diagnostic performance are now clearly established. But despite the essential simplicity of the approach, workers in the field ofte...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198903000-00012

    authors: Metz CE

    更新日期:1989-03-01 00:00:00

  • Hepatic parenchymal changes after the intraarterial injection of lipiodol in tumor-bearing rabbits.

    abstract:RATIONALE AND OBJECTIVES:The influence of lipiodol injection on hepatic morphology and function was investigated in 119 rabbits with hepatic VX2 tumors. METHODS:The rabbits were divided into the following three groups, according to the materials injected via the proper hepatic artery: group 1 received doxorubicin (Adr...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199302000-00009

    authors: Akashi Y,Koreeda C,Mizuno T,Inoue K,Kawa SK,Tanaka Y

    更新日期:1993-02-01 00:00:00

  • Clinical and High-Resolution CT Features of the COVID-19 Infection: Comparison of the Initial and Follow-up Changes.

    abstract:OBJECTIVES:In late December 2019, an outbreak of coronavirus disease (COVID-19) in Wuhan, China was caused by a novel coronavirus, newly named severe acute respiratory syndrome coronavirus 2. We aimed to quantify the severity of COVID-19 infection on high-resolution chest computed tomography (CT) and to determine its r...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000674

    authors: Xiong Y,Sun D,Liu Y,Fan Y,Zhao L,Li X,Zhu W

    更新日期:2020-06-01 00:00:00

  • Pulmonary density distribution in experimental noncardiac canine pulmonary edema evaluated by computed transmission tomography.

    abstract::We evaluated the density distribution (anterior-posterior) of the right lung in 19 acutely anesthetized supine dogs using computed transmission tomography (CTT). Eleven dogs served as controls, and eight received 0.12 cc/kg of intravenously administered oleic acid. The latter were sequentially imaged over 1 hour. Nine...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:

    authors: Slutsky RA,Long S,Peck WW,Higgins CB,Mattrey R

    更新日期:1984-05-01 00:00:00

  • The use of continuous and discrete confidence judgments in receiver operating characteristic studies of diagnostic imaging techniques.

    abstract::Virtually all receiver operating characteristic (ROC) studies of medical imaging methods have involved data collected on a discrete confidence-rating scale, though in principle ROC studies can be conducted with either discrete or continuous scales. Continuous scales provide potential advantages in medical applications...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199202000-00016

    authors: Rockette HE,Gur D,Metz CE

    更新日期:1992-02-01 00:00:00

  • Assessment of myocardial viability using delayed enhancement magnetic resonance imaging at 3.0 Tesla.

    abstract:OBJECTIVE:Cardiac magnetic resonance imaging (MRI) at 3.0 T has recently become available and potentially provides a significant improvement of tissue contrast in T1-weighted imaging techniques relying on Gd-based contrast enhancement. Imaging at high-field strength may be especially advantageous for methods relying on...

    journal_title:Investigative radiology

    pub_type: 临床试验,杂志文章

    doi:10.1097/01.rli.0000233321.82194.09

    authors: Klumpp B,Fenchel M,Hoevelborn T,Helber U,Scheule A,Claussen C,Miller S

    更新日期:2006-09-01 00:00:00

  • Long-term effect of irradiation on lymph node uptake of interstitially delivered nanoparticulate contrast media.

    abstract:RATIONALE AND OBJECTIVES:To characterize the long-term effects of therapeutic doses of ionizing radiation on the uptake and distribution of percutaneously delivered particulate contrast media in normal lymph nodes. METHODS:Two milliliters of an iodinated nanoparticle suspension (76 mg I/mL) was injected subcutaneously...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-200003000-00007

    authors: Wisner ER,Théon A,Griffey SM,McIntire GL

    更新日期:2000-03-01 00:00:00

  • Embolization of superior mesenteric artery branches in dogs. Ischemic bowel changes depend on location of vessel occlusion and embolic materials.

    abstract:OBJECTIVE:To evaluate the degree of ischemic changes of the small intestine after arterial embolization of proximal or distal arteries with Gelfoam particles and coils in dogs. METHODS:Superselective arterial embolization in 18 dogs was performed using a coaxial catheter system. Gelfoam occlusion of the proximal level...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199910000-00004

    authors: Han YM,Lee JM,Jin KY,Lee SY,Kim CS

    更新日期:1999-10-01 00:00:00

  • Magnetic resonance pulmonary angiography and direct imaging of embolus for the detection of pulmonary emboli.

    abstract:RATIONALE AND OBJECTIVES:The authors developed a two-dimensional breathhold magnetic resonance (MR) technique for the direct imaging of pulmonary emboli. METHODS:In vitro MR imaging was performed to demonstrate the potential generation of clot-blood contrast by in vivo pulmonary embolism (PE). A two-dimensional magnet...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199708000-00001

    authors: Moody AR,Liddicoat A,Krarup K

    更新日期:1997-08-01 00:00:00

  • Myocardial wall motion evaluation using amplitude frequency spectral analysis.

    abstract::Frequency spectral analysis of cardiac wall motion as calculated from the recorded video kymogram are demonstrated. Characteristic harmonics following the fundamental frequency of the cardiac rate have been demonstrated to have an alternating sequential energy distribution as measured from the free margin of the left ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-197503000-00005

    authors: Silverman NR,Rosen L,Helland DR

    更新日期:1975-03-01 00:00:00

  • Specific absorption rate as a poor indicator of magnetic resonance-related implant heating.

    abstract::Recent publications of the magnetic resonance safety profile of neurostimulators, cardiac pacemakers, and other implanted devices imply that these devices are no longer a contraindication for magnetic resonance imaging. It is very promising that patients who have these implanted devices may in the future no longer be ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/01.rli.0000185898.59140.91

    authors: Nitz WR,Brinker G,Diehl D,Frese G

    更新日期:2005-12-01 00:00:00

  • Comparison of Routine Brain Imaging at 3 T and 7 T.

    abstract:OBJECTIVE:The aim of this study was to compare quantitative and semiquantitative parameters (signal-to-noise ratio [SNR], contrast-to-noise ratio [CNR], image quality, diagnostic confidence) from a standard brain magnetic resonance imaging examination encompassing common neurological disorders such as demyelinating dis...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000256

    authors: Springer E,Dymerska B,Cardoso PL,Robinson SD,Weisstanner C,Wiest R,Schmitt B,Trattnig S

    更新日期:2016-08-01 00:00:00

  • Ventral sacroiliac ligament. Anatomic and pathologic considerations.

    abstract:RATIONALE AND OBJECTIVES:The ventral sacroiliac ligament (VSL), which bridges the sacroiliac (SI) joint anteriorly, has been described as an important stabilizing structure of the joint, but no data exist regarding its assessment with routine and advanced imaging methods. The authors determine the imaging appearance of...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199608000-00009

    authors: Jaovisidha S,Ryu KN,De Maeseneer M,Haghighi P,Goodwin D,Sartoris DJ,Resnick D

    更新日期:1996-08-01 00:00:00

  • Effect of lumbar puncture on flow of cerebrospinal fluid.

    abstract::The rate at which isotopes descend from the cisterna magna to the lumbar subarachnoid space is highly variable. In monkeys, with and without previous lumbar puncture, transit time was measured. In animals with a previous lumbar puncture, transit times were 10 to 120 minutes; in monkeys without a previous lumbar punctu...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198805000-00005

    authors: Lipman B,Palmer D,Noble J,Haughton V,Collier D

    更新日期:1988-05-01 00:00:00

  • The use of a thrombus-specific ultrasound contrast agent to detect thrombus in arteriovenous fistulae.

    abstract:RATIONALE AND OBJECTIVES:To evaluate the use of a new thrombus-specific ultrasound contrast agent, MRX-408, in the ultrasonic detection of thrombus in arteriovenous (AV) fistulae. METHODS:Six purpose-bred mongrels with two AV fistulae each were imaged with gray-scale ultrasound 7 weeks after graft implantation before ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-200001000-00010

    authors: Unger E,Metzger P 3rd,Krupinski E,Baker M,Hulett R,Gabaeff D,Mills J,Ihnat D,McCreery T

    更新日期:2000-01-01 00:00:00

  • Breast stereotactic core biopsy washings: abundant cell samples from clinically occult lesions for flow cytometric DNA analysis.

    abstract:RATIONALE AND OBJECTIVES:The object of this study was to determine by flow cytometry the cellular and DNA content of the washings of core biopsy samples and needles obtained during stereotactic core biopsies of clinically occult suspicious lesions. METHODS:Fourteen-gauge core multipass biopsy inner-needle saline washi...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199801000-00008

    authors: Stomper PC,Budnick RM,Stewart CC

    更新日期:1998-01-01 00:00:00

  • Comparative evaluation of digital radiography versus conventional radiography of fractured skulls.

    abstract:OBJECTIVES:The authors assessed the relative efficacy of conventional and digital storage-phosphor radiographs for the detection of skull fractures. METHODS:Fifty conventional film-screen radiographs (FSR) and 50 digital storage-phosphor radiographs (DR) with 66 fractures were compared. Five radiologists evaluated ima...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199308000-00005

    authors: Langen HJ,Klein HM,Wein B,Stargardt A,Günther RW

    更新日期:1993-08-01 00:00:00

  • Magnetic resonance imaging using gadolinium labeled monoclonal antibody.

    abstract::Gadolinium was attached to antibodies and tested in vitro and in vivo for its effect on proton relaxation enhancement. Using the cyclic anhydride method, diethylenetriaminepentaacetic acid (DTPA) was attached to albumin, IgG and anti-CEA monoclonal antibody. Gadolinium (Gd) was then chelated to the protein complexes f...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198510000-00008

    authors: Unger EC,Totty WG,Neufeld DM,Otsuka FL,Murphy WA,Welch MS,Connett JM,Philpott GW

    更新日期:1985-10-01 00:00:00

  • Trabecular bone structure of the distal radius, the calcaneus, and the spine: which site predicts fracture status of the spine best?

    abstract:RATIONALE AND OBJECTIVES:To compare trabecular bone structure measures obtained in magnetic resonance images of the distal radius and the calcaneus as well as computed tomographic images of the spine versus bone mineral density (BMD) of the spine and the calcaneus in the prediction of osteoporotic spine fracture status...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/01.rli.0000129154.50654.4e

    authors: Link TM,Bauer J,Kollstedt A,Stumpf I,Hudelmaier M,Settles M,Majumdar S,Lochmüller EM,Eckstein F

    更新日期:2004-08-01 00:00:00

  • Clinical safety and diagnostic value of the gadolinium chelate gadoterate meglumine (Gd-DOTA).

    abstract:OBJECTIVE:The purpose of this study was to assess the diagnostic value and safety of the contrast agent gadoterate meglumine (Gd-DOTA, DOTAREM, Guerbet, Roissy CdG Cedex, France) in the setting of a postmarketing surveillance study. MATERIALS AND METHODS:Between January 2004 and October 2005, radiologists in 61 radiol...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/01.rli.0000248893.01067.e5

    authors: Herborn CU,Honold E,Wolf M,Kemper J,Kinner S,Adam G,Barkhausen J

    更新日期:2007-01-01 00:00:00

  • High-Signal Intensity in the Dentate Nucleus and Globus Pallidus on Unenhanced T1-Weighted Images: Evaluation of the Macrocyclic Gadolinium-Based Contrast Agent Gadobutrol.

    abstract:OBJECTIVE:The aim of this study was to compare changes in the signal intensity (SI) ratio of the dentate nucleus (DN) to the pons, DN to cerebrospinal fluid (CSF), and globus pallidus (GP) to thalamus on unenhanced T1-weighted magnetic resonance imaging (MRI) scans after serial injections of the macrocyclic gadolinium-...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000227

    authors: Radbruch A,Weberling LD,Kieslich PJ,Hepp J,Kickingereder P,Wick W,Schlemmer HP,Bendszus M

    更新日期:2015-12-01 00:00:00

  • Pharmacologic treatment of intimal hyperplasia after metallic stent placement in the peripheral arteries. An experimental study.

    abstract:RATIONALE AND OBJECTIVES:To evaluate the efficacy of oral administration of cilostazol, an antithrombotic agent, for the prevention of thrombotic occlusion and intimal hyperplasia after stenting. METHODS:Single-bodied Z-stents were placed in the iliac arteries of 23 dogs. Before stenting, an embolizing coil was introd...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199509000-00004

    authors: Kubota Y,Kichikawa K,Uchida H,Maeda M,Nishimine K,Makutani S,Sakaguchi S,Yoshioka T,Ohishi H,Kimura Y

    更新日期:1995-09-01 00:00:00

  • Terbutaline in diagnosis of interstitial fallopian tube obstruction.

    abstract::Effectiveness of terbutaline, a potent uterine muscle relaxant, for differentiation of temporary and anatomic interstitial fallopian tube obstruction (IFTO) at hysterosalpingography (HSG) was explored. In 43 IFTO evaluated, HSG after terbutaline showed patency in only one of 16 tubes in which IFTO was caused by spasm ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198803000-00010

    authors: Thurmond AS,Novy M,Rösch J

    更新日期:1988-03-01 00:00:00

  • Characterization of ultrasmall magnetite [correction of paramagnetic magnetite] particles as superparamagnetic contrast agents in MRI.

    abstract:RATIONALE AND OBJECTIVES:Very small dextran-coated magnetite particles were developed. These particles can be used either as immunospecific contrast agents for MRI by coupling to antibodies or as an interstitial contrast agent. METHODS:The particles were synthesized from iron chloride/dextran solutions. Size was evalu...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-200009000-00006

    authors: Grimm J,Karger N,Lüsse S,Winoto-Morbach S,Krisch B,Müller-Hülsbeck S,Heller M

    更新日期:2000-09-01 00:00:00

  • Granulocyte accumulation in the transplanted liver does not correlate with clinical and histologic evidence of dysfunction.

    abstract:RATIONALE AND OBJECTIVES:To evaluate the role of granulocytes in reperfusion injury after liver transplantation. The authors injected radiolabeled granulocytes to determine if human liver graft outcome could be correlated with granulocyte accumulation. MATERIALS AND METHODS:Pure granulocyte suspension was prepared fro...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199603000-00003

    authors: Ziser A,Forstrom LA,Plevak DJ,Sanchez-Urdazpal L,Gores GJ,Wiesner RH,Batts KP,Krom RA

    更新日期:1996-03-01 00:00:00

  • Lung perfusion demonstrated by contrast-enhanced dynamic magnetic resonance imaging. Application to unilateral lung transplantation.

    abstract:RATIONALE AND OBJECTIVES:The authors evaluate the use of magnetic resonance (MR) to image pulmonary perfusion in healthy controls and to detect pulmonary defects in patients with unilateral lung transplantation, using dynamic images after contrast administration. METHODS:Five patients with right lung transplantation a...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199706000-00006

    authors: Berthezène Y,Croisille P,Bertocchi M,Houzard C,Bendib K,Revel D

    更新日期:1997-06-01 00:00:00

  • Analysis of edge-tracking errors inherent in fluoroscopic images of the beating heart.

    abstract:RATIONALE AND OBJECTIVES:Because of the complex relationships between the dynamic three-dimensional cardiac surface shape and its projected image, errors arise with the use of two-dimensional silhouettes to measure displacements of the heart. The character and frequency of such errors are examined. METHODS:A high-prec...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199403000-00004

    authors: McInerney JJ,Weldner PW,Herr MD,Copenhaver GL

    更新日期:1994-03-01 00:00:00

  • Radiation hormesis. Its emerging significance in medical practice.

    abstract::Because of the strong scientific evidence in support of radiation hormesis, we can no longer ignore this concept. There is, however, need for additional, carefully documented investigations in selected biological systems exposed to LLIR if the matter of radiation hormesis is to be settled once and for all. This need s...

    journal_title:Investigative radiology

    pub_type: 杂志文章,评审

    doi:

    authors: Loken MK,Feinendegen LE

    更新日期:1993-05-01 00:00:00

  • In-vitro assessment of the behavior of magnetic resonance angiography in the presence of constrictions.

    abstract:RATIONALE AND OBJECTIVES:Time-of-flight magnetic resonance angiography (TOF/MRA) is increasingly used to assess the nature and severity of stenotic blood vessels. Flow artifacts associated with high flows and/or narrow constrictions may confuse the interpretation of these studies. Accurate TOF/MRA evaluations demand an...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199307000-00011

    authors: Sebok NR,Sebok DA,Wilkerson D,Mezrich RS,Zatina M

    更新日期:1993-07-01 00:00:00

  • The role of catheters and guidewires in the production of angiographic thromboembolic complications.

    abstract::Thromboembolic complications occurring during angiography may result from a number of different causes. Catheters and guidewires can interact with blood to form thrombi; this tendency is related to wall defects and the chemical composition and structural characteristics of the catheters and guidewires. Nonthrombic sou...

    journal_title:Investigative radiology

    pub_type: 杂志文章,评审

    doi:10.1097/00004424-198811002-00009

    authors: Kido DK,King PD,Manzione JV,Simon JH

    更新日期:1988-11-01 00:00:00