In vivo and in vitro evaluation of Gd-DTPA-polylysine as a macromolecular contrast agent for magnetic resonance imaging.

Abstract:

:Polylysine covalently linked to moieties of gadopentetate (Gd-DTPA), for use as a macromolecular blood pool marker for contrast material-enhanced magnetic resonance imaging (MRI), was characterized by means of physicochemical measurements and pharmacokinetics in rats and rabbits and compared with Gd-DTPA. Gd-DTPA-polylysine was composed of a series of polymers of different molecular sizes that on average were labeled with 60 to 70 Gd-DTPA moieties (average molecular weight, 48,700 daltons [D]). For the macromolecular compound Gd-DTPA-polylysine, relaxivity was three times higher than that of Gd-DTPA. The LD50 value of 17 mmol/kg reflects a fairly high acute intravenous tolerance of the macromolecular compound in mice. Even though the volume of distribution of Gd-DTPA-polylysine in rabbits approached the extracellular fluid space (indicating that the macromolecular compound was also leaking slowly into the interstitial space), the half-life of distribution of the macromolecular compound in the extracellular fluid space was significantly prolonged, thus making the compound suitable as a blood pool marker for MRI. In rats the elimination of Gd-DTPA-polylysine occurred predominantly via the renal route. High-pressure liquid chromatography-size-exclusion chromatography of the fractionated urine samples revealed that the renal clearance must be the integral sum of the separate clearances of each molecular weight species. No biodegradation of the polypeptide was observed, and biodistribution studies revealed only minimal retention of Gd in the body of the rat.

journal_name

Invest Radiol

journal_title

Investigative radiology

authors

Schuhmann-Giampieri G,Schmitt-Willich H,Frenzel T,Press WR,Weinmann HJ

doi

10.1097/00004424-199111000-00008

subject

Has Abstract

pub_date

1991-11-01 00:00:00

pages

969-74

issue

11

eissn

0020-9996

issn

1536-0210

journal_volume

26

pub_type

杂志文章
  • Quantitative computed tomography of the lungs and airways in healthy nonsmoking adults.

    abstract:OBJECTIVES:The purposes of this study were to evaluate the reference range of quantitative computed tomography (QCT) measures of lung attenuation and airway parameter measurements in healthy nonsmoking adults and to identify sources of variation in those measures and possible means to adjust for them. MATERIALS AND ME...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e318262292e

    authors: Zach JA,Newell JD Jr,Schroeder J,Murphy JR,Curran-Everett D,Hoffman EA,Westgate PM,Han MK,Silverman EK,Crapo JD,Lynch DA,COPDGene Investigators.

    更新日期:2012-10-01 00:00:00

  • Right-Angled Traction Bronchiectasis in Differentiating Idiopathic Pulmonary Fibrosis Without Honeycombing From Idiopathic Nonspecific Interstitial Pneumonia.

    abstract:OBJECTIVES:The aim of this study was to conduct a radiopathologic evaluation of right-angled traction bronchiectasis to differentiate idiopathic pulmonary fibrosis (IPF) without honeycombing from idiopathic nonspecific interstitial pneumonia (NSIP). MATERIALS AND METHODS:The derivation cohort included 78 consecutive p...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000651

    authors: Kim H,Yoon SH,Lee HJ,Song SG,Koh J,Jeon YK,Chae KJ,Jin GY,Jin KN,Lee KY,Goo JM

    更新日期:2020-06-01 00:00:00

  • The allergic theory of radiocontrast agent toxicity: demonstration of antibody activity in sera of patients suffering major radiocontrast agent reactions.

    abstract::An allergic, immunologic mechanism for certain adverse reactions to radiocontrast agents has been postulated on the basis of clinical and theoretical considerations. One obstacle to the acceptance of this allergic theory has been the inability to demonstrate significant antibodies with specificity for these agents. In...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-197609000-00002

    authors: Brasch RC,Caldwell JL

    更新日期:1976-09-01 00:00:00

  • Contrast-detail phantom study for x-ray spectrum optimization regarding chest radiography using a cesium iodide-amorphous silicon flat-panel detector.

    abstract:RATIONALE AND OBJECTIVES:The purpose of this study evaluating a cesium iodide-amorphous silicon-based flat-panel detector was to optimize the x-ray spectrum for chest radiography combining excellent contrast-detail visibility with reduced patient exposure. MATERIALS AND METHODS:A Lucite plate with 36 drilled holes of ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/01.rli.0000138091.96320.f8

    authors: Hamer OW,Völk M,Zorger N,Borisch I,Büttner R,Feuerbach S,Strotzer M

    更新日期:2004-10-01 00:00:00

  • Nonparametric estimation of degenerate ROC data sets used for comparison of imaging systems.

    abstract::Maximum likelihood estimation, assuming a binormal model, has been used extensively to estimate the area under receiver operating characteristic (ROC) curves and thus provide an index of diagnostic accuracy for the comparison of two imaging systems. However, in some instances, a degenerate data set results in a fitted...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199007000-00016

    authors: Rockette HE,Obuchowski NA,Gur D

    更新日期:1990-07-01 00:00:00

  • Curriculum for musculoskeletal radiology.

    abstract::Although general suggestions have been made regarding a radiology residency curriculum, no specific list of entities has been offered. Over the past ten years, we have developed a resident-run morning conference in musculoskeletal radiology that is supervised by faculty and covers a specific curriculum. We offer our c...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199111000-00019

    authors: Renfrew DL,el-Khoury GY,Moore TE,Kathol MH,Whitten CG,Walker CW,Fraser-Hill MA

    更新日期:1991-11-01 00:00:00

  • The effect of radiographic contrast media on leukocyte motility.

    abstract:RATIONALE AND OBJECTIVES:Studies describing the effects of radiographic contrast media (RCM) in leukocyte chemotaxis have been contradictory. No studies have been performed after in-vivo exposure. The authors assess the effect of RCM on leukocytes following in-vivo exposure. METHODS:Seventeen patients were studied aft...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199401000-00012

    authors: Roobottom CA,Farrow R,Wells IP,Hurlock-Fimls N

    更新日期:1994-01-01 00:00:00

  • 3 T contrast-enhanced magnetic resonance angiography for evaluation of the intracranial arteries: comparison with time-of-flight magnetic resonance angiography and multislice computed tomography angiography.

    abstract:PURPOSE:We sought to prospectively evaluate the image quality and visualization of the intracranial arteries using high spatial resolution contrast-enhanced magnetic resonance angiography (CE-MRA) at 3 T and to perform intraindividual comparison with time-of-flight (TOF) MRA and multislice CT angiography (CTA). MATERI...

    journal_title:Investigative radiology

    pub_type: 临床试验,杂志文章

    doi:10.1097/01.rli.0000242835.00032.f5

    authors: Villablanca JP,Nael K,Habibi R,Nael A,Laub G,Finn JP

    更新日期:2006-11-01 00:00:00

  • CT Dosimetry: What Has Been Achieved and What Remains to Be Done.

    abstract::Radiation dose in computed tomography (CT) has become a hot topic due to an upward trend in the number of CT procedures worldwide and the relatively high doses associated with these procedures. The main aim of this review article is to provide an overview of the most frequently used metrics for CT radiation dose chara...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000727

    authors: Damilakis J

    更新日期:2021-01-01 00:00:00

  • Experimental arterial stent placement. Comparison of a new Nitinol stent and Wallstent.

    abstract:RATIONALE AND OBJECTIVES:To compare technical aspects and neointima formation of a new Nitinol stent and a Wallstent. METHODS:A Nitinol sten and a Wallstent were placed into the iliac arteries of 14 sheep (total of 28 stents) and followed angiographically. Seven sheep were killed after 1 month and 7 after 4.5 months. ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199507000-00004

    authors: Schürmann K,Vorwerk D,Kulisch A,Stroehmer-Kulisch E,Biesterfeld S,Stopinski T,Günther RW

    更新日期:1995-07-01 00:00:00

  • Evaluation of Gd-EOB-DTPA uptake in a perfused and isolated mouse liver model: correlation between magnetic resonance imaging and monochromatic quantitative computed tomography.

    abstract:OBJECTIVES:The aim of this work was to quantitatively evaluate the pharmacokinetic pattern of Gd-EOB-DTPA in a model of isolated and perfused mouse liver by using magnetic resonance imaging (MRI) and monochromatic quantitative computed tomography (MQCT). MATERIALS AND METHODS:For MQCT, perfusions were realized with th...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/01.rli.0000174474.43772.58

    authors: Segers J,Le Duc G,Laumonier C,Troprès I,Elst LV,Muller RN

    更新日期:2005-09-01 00:00:00

  • Comparison of Power Versus Manual Injection in Bolus Shape and Image Quality on Contrast-Enhanced Magnetic Resonance Angiography: An Experimental Study in a Swine Model.

    abstract:OBJECTIVE:The aim of this study was to compare power versus manual injection in bolus shape and image quality on contrast-enhanced magnetic resonance angiography (CE-MRA). MATERIALS AND METHODS:Three types of CE-MRA (head-neck 3-dimensional [3D] MRA with a test-bolus technique, thoracic-abdominal 3D MRA with a bolus-t...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000383

    authors: Tsuboyama T,Jost G,Pietsch H,Tomiyama N

    更新日期:2017-09-01 00:00:00

  • Assessment of a non-ionic contrast medium (Amipaque) in the gastrointestinal tract.

    abstract::Gastrografin and Amipaque with identical iodine content and flavoring were orally administered in 100 ml doses to 10 healthy volunteers in a double-blind crossover study. The nonionic Amipaque has only about one third of the osmolality of Gastrografin, and draws less fluid into the bowel lumen. Consequently there is l...

    journal_title:Investigative radiology

    pub_type: 临床试验,杂志文章

    doi:10.1097/00004424-197811000-00008

    authors: Johansen JG

    更新日期:1978-11-01 00:00:00

  • Retrievable patent ductus arteriosus plug for interventional, transvenous occlusion of the patent ductus arteriosus. Evaluation in lambs and preliminary clinical results.

    abstract:RATIONALE AND OBJECTIVES:The clinically most widely used devices (Porstmann-plug, Rashkind-umbrella, Botallooccluder) have inherent specific limitations (eg, transarterial approach, residual shunts, limited retrieval). The authors assess practicability, efficacy, and tissue reaction of the new retrievable transvenous p...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199709000-00004

    authors: Grabitz RG,Schräder R,Sigler M,Seghaye MC,Dzionsko C,Handt S,Schneidt B,Von Bernuth G

    更新日期:1997-09-01 00:00:00

  • Alteration of human tumor cell adhesion by high-strength static magnetic fields.

    abstract:RATIONALE AND OBJECTIVES:The authors investigated whether the ability of human malignant melanoma cells to increase in cell number or their ability to remain viable was compromised by high-field strength static magnetic fields. Normal human fibroblasts also were studied to determine if any magnetic field-related altera...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199210000-00014

    authors: Short WO,Goodwill L,Taylor CW,Job C,Arthur ME,Cress AE

    更新日期:1992-10-01 00:00:00

  • Technical feasibility and performance studies of a 0.009-inch nitinol microguidewire for potential neuroendovascular applications.

    abstract:RATIONALE AND OBJECTIVES:The authors conduct technical feasibility and performance studies on a new 0.009-inch nitinol microguidewire for potential neuroendovascular applications. METHODS:In vivo microcatheterizations of brachiocephalic arteries were performed in four pigs using the 0.009-inch nitinol microguidewire w...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199704000-00008

    authors: Putman CM,Chaloupka JC,Kailasnath P,Alderman J

    更新日期:1997-04-01 00:00:00

  • Correlation of flow velocity measurements by magnetic resonance phase contrast imaging and intravascular Doppler ultrasound.

    abstract:RATIONALE AND OBJECTIVES:The authors compare the magnetic resonance (MR) phase contrast flow velocity measurements in varying concentric stenoses with invasive measurements obtained with a Doppler guidewire. METHODS:Flow velocity measurements were obtained using a calibrated 0.018 inch 12 MHz Doppler guidewire and a 1...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199808000-00001

    authors: Hoppe M,Heverhagen JT,Froelich JJ,Kunisch-Hoppe M,Klose KJ,Wagner HJ

    更新日期:1998-08-01 00:00:00

  • Hepatocellular carcinoma: correlation between vascular endothelial growth factor level and degree of enhancement by multiphase contrast-enhanced computed tomography.

    abstract:RATIONALE AND OBJECTIVES:To determine whether vascular endothelial growth factor (VEGF) is a histopathological factor influencing contrast enhancement of hepatocellular carcinoma (HCC) on computed tomography (CT). METHODS:Twenty-two nodular HCCs underwent multiphase helical CT and surgery. Tumor size, histological gra...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-200108000-00008

    authors: Kwak BK,Shim HJ,Park ES,Kim SA,Choi D,Lim HK,Park CK,Chung JW,Park JH

    更新日期:2001-08-01 00:00:00

  • Evaluation of radiologist interpretive performance using blinded reads by multiple external readers.

    abstract:OBJECTIVE:To demonstrate a method of assessing radiologic diagnostic agreement utilizing multiple blinded external readers. METHODS:Six body CT studies interpreted by one reader (primary reader) at the host institution were compiled with patient identifiers removed. Brief clinical histories that were available to the ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e3181d2ee97

    authors: Ryan AF,Semelka RC,Molina PL,Yonkers S,Vaidean G

    更新日期:2010-04-01 00:00:00

  • Biliary tract depiction in living potential liver donors at 3.0-T magnetic resonance cholangiography.

    abstract:OBJECTIVES:To prospectively evaluate accuracy of biliary anatomy depiction and quality of biliary tract visualization of magnetic resonance cholangiography (MRC) at 3.0 T in living potential liver donors (LPLDs). MATERIALS AND METHODS:Our institutional review board approved this study and did not require patient's inf...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e31817e9b52

    authors: Kim SY,Byun JH,Hong HS,Choi EK,Lee SS,Park SH,Lee MG

    更新日期:2008-08-01 00:00:00

  • Ventral sacroiliac ligament. Anatomic and pathologic considerations.

    abstract:RATIONALE AND OBJECTIVES:The ventral sacroiliac ligament (VSL), which bridges the sacroiliac (SI) joint anteriorly, has been described as an important stabilizing structure of the joint, but no data exist regarding its assessment with routine and advanced imaging methods. The authors determine the imaging appearance of...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199608000-00009

    authors: Jaovisidha S,Ryu KN,De Maeseneer M,Haghighi P,Goodwin D,Sartoris DJ,Resnick D

    更新日期:1996-08-01 00:00:00

  • Sensitivity to detect small coronary artery calcium lesions with varying slice thickness using electron beam tomography.

    abstract:RATIONALE AND OBJECTIVE:To estimate the sensitivity to find small coronary artery calcium lesions with use of different slice widths with electron beam tomography. MATERIALS AND METHODS:Two studies were performed. Study 1 utilized double scanning of a stationary cork phantom with three different slice thickness (1.5, ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/01.RLI.0000055289.97726.B1

    authors: Mao S,Child J,Carson S,Liu SC,Oudiz RJ,Budoff MJ

    更新日期:2003-03-01 00:00:00

  • Noninvasive measurement of an index of renal blood flow.

    abstract::A new technique for the noninvasive measurement of an index of renal blood flow is described. The method utilizes ultrasound determined renal volume and radionuclide assessment of the mean transit time of a pertechnetate bolus through the kidneys. From this information a value for flow is calculated according to compa...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198307000-00009

    authors: Powers TA,Rees RS,Bowen RD

    更新日期:1983-07-01 00:00:00

  • Transverse ligament and its effect on meniscal motion. Correlation of kinematic MR imaging and anatomic sections.

    abstract:RATIONALE AND OBJECTIVES:To evaluate the effect of the transverse ligament on translation of the menisci. METHODS:Six cadaveric knees were examined by MR imaging inside a positioning device before and after transecting the transverse ligament. The knees were examined at various positions: extension, 30 degrees of flex...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199909000-00002

    authors: Muhle C,Thompson WO,Sciulli R,Pedowitz R,Ahn JM,Yeh L,Clopton P,Haghighi P,Trudell DJ,Resnick D

    更新日期:1999-09-01 00:00:00

  • Binary nature and radiographic identifiability of craniosynostosis.

    abstract:RATIONALE AND OBJECTIVES:Two independent gold standards and diagnoses from three-dimensional computed tomography (CT) images were used to examine the possibility that craniosynostosis is a binary abnormality that potentially may be diagnosed without error. METHODS:Surgical reports, histology of excised sutures, and th...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199410000-00005

    authors: Pilgram TK,Vannier MW,Marsh JL,Kraemer BB,Rayne SC,Gado MH,Moran CJ,McAlister WH,Shackelford GD,Hardesty RA

    更新日期:1994-10-01 00:00:00

  • Safety and efficacy of dotarem (Gd-DOTA) versus magnevist (Gd-DTPA) in magnetic resonance imaging of the central nervous system.

    abstract:RATIONALE AND OBJECTIVES:Gd-DTPA is a well-characterized, safe contrast agent frequently used in magnetic resonance imaging (MRI) of the central nervous system. The purpose of this double-blind, comparative MRI study of brain, spine, trunk, and limbs was to evaluate the safety and efficacy of Gd-DOTA versus Gd-DTPA in ...

    journal_title:Investigative radiology

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1097/00004424-199502000-00002

    authors: Oudkerk M,Sijens PE,Van Beek EJ,Kuijpers TJ

    更新日期:1995-02-01 00:00:00

  • Collateral arterial formation. Lymph draining ischemic kidneys contains a neovascular stimulating agent of high molecular weight.

    abstract::An agent has been identified in lymph from rat kidneys rendered ischemic by partial renal artery occlusion that induces a striking neovascular response in a hamster cheek-pouch assay system. The factor has a high molecular weight, cannot be identified in lymph from normal kidneys, and is associated with a marked incre...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198501000-00015

    authors: Hollenberg NK,Paskins-Hurlburt AJ,Abrams HL

    更新日期:1985-01-01 00:00:00

  • Comparison of left ventricular ejection fraction and regional contractility fraction pre and post coronary angiography.

    abstract::Thirty patients [four normals, eight with mild and 18 with severe coronary artery disease (CAD)] were studied to evaluate left ventricular function type and post coronary angiography. The end diastolic volume (EDV), end systolic volume (ESV), ejection fraction (EF) and the regional contractility fractions (RCF) of eig...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-197603000-00009

    authors: Sos TA,Baltaxe HA

    更新日期:1976-03-01 00:00:00

  • Long-term effect of irradiation on lymph node uptake of interstitially delivered nanoparticulate contrast media.

    abstract:RATIONALE AND OBJECTIVES:To characterize the long-term effects of therapeutic doses of ionizing radiation on the uptake and distribution of percutaneously delivered particulate contrast media in normal lymph nodes. METHODS:Two milliliters of an iodinated nanoparticle suspension (76 mg I/mL) was injected subcutaneously...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-200003000-00007

    authors: Wisner ER,Théon A,Griffey SM,McIntire GL

    更新日期:2000-03-01 00:00:00

  • Estimation of chemical composition and density from computed tomography carried out at a number of energies.

    abstract::A method is presented by whichcomputed tomography scans carried out at a number of energies may be utilized to obtain cross-sectional images of density and atomic number in addition to the conventional array of linear attenuation coefficients. This type of analysis has been carried out for various substances of biolog...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-197703000-00016

    authors: McDavid WD,Waggener RG,Dennis MJ,Sank VJ,Payne WH

    更新日期:1977-03-01 00:00:00