Assessment of a non-ionic contrast medium (Amipaque) in the gastrointestinal tract.

Abstract:

:Gastrografin and Amipaque with identical iodine content and flavoring were orally administered in 100 ml doses to 10 healthy volunteers in a double-blind crossover study. The nonionic Amipaque has only about one third of the osmolality of Gastrografin, and draws less fluid into the bowel lumen. Consequently there is less dilution with Amipaque, and a higher contrast density in the ileocecal region can be observed. Unlike the highly hypertonic Gastrografin, Amipaque causes less changes in hematocrit, and has only a very mild cathartic effect. No more than 0.4% of the iodine in Amipaque was excreted in the urine during one day, and no more than 0.8% during three days. This was less than the excretion found after ingestion of Gastrografin. Non-ionic media are recommended when there is an indication for use of water-soluble contrast media in the gastrointestinal tract.

journal_name

Invest Radiol

journal_title

Investigative radiology

authors

Johansen JG

doi

10.1097/00004424-197811000-00008

subject

Has Abstract

pub_date

1978-11-01 00:00:00

pages

523-7

issue

6

eissn

0020-9996

issn

1536-0210

journal_volume

13

pub_type

临床试验,杂志文章
  • Ultrasound analysis of tongue, hyoid, and larynx activity during swallowing.

    abstract::Using real-time ultrasound, the motions of the tongue, hyoid bone, and larynx were monitored and timed during swallowing in ten normal subjects. A well-defined propulsive wave of the tongue was observed during swallowing a 5-cc water bolus. The body of the hyoid bone was identified on the ultrasound scan as a high ech...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198403000-00003

    authors: Shawker TH,Sonies B,Hall TE,Baum BF

    更新日期:1984-03-01 00:00:00

  • The biliary and urinary excretion of sodium tyropanoate and sodium ipodate in dogs: pharmacokinetics, influence of bile salts and choleretic effects with comparison to iopanoic acid.

    abstract::The biliary and urinary excretion of sodium tyropanoate (Bilopaque) and sodium ipodate (Oragrafin) were studied in unanesthetized bile-fistula dogs using stepwise, increasing, intravenous infusions of the contrast materials. A constant intravenous infusion of sodium taurocholate was administered at the rate of either ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-197701000-00017

    authors: Berk RN,Loeb PM,Cobo-Frenkel A,Barnhart JL

    更新日期:1977-01-01 00:00:00

  • Peripheral magnetic resonance angiography with continuous table movement in combination with high spatial and temporal resolution time-resolved MRA With a total single dose (0.1 mmol/kg) of gadobutrol at 3.0 T.

    abstract:PURPOSE:To prove the concept of peripheral continuous table movement (CTM) MR-angiography (MRA) in combination with high spatial and temporal resolution time-resolved TWIST-MRA in a single MR-examination at 3.0 T with a single dose (0.1 mmol/kg) of gadobutrol in total. MATERIALS AND METHODS:We included 22 consecutive ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e3181b4c26c

    authors: Voth M,Haneder S,Huck K,Gutfleisch A,Schönberg SO,Michaely HJ

    更新日期:2009-09-01 00:00:00

  • Solid, part-solid, or non-solid?: classification of pulmonary nodules in low-dose chest computed tomography by a computer-aided diagnosis system.

    abstract:OBJECTIVES:The purpose of this study was to develop and validate a computer-aided diagnosis (CAD) tool for automatic classification of pulmonary nodules seen on low-dose computed tomography into solid, part-solid, and non-solid. MATERIALS AND METHODS:Study lesions were randomly selected from 2 sites participating in t...

    journal_title:Investigative radiology

    pub_type: 临床试验,杂志文章,多中心研究,随机对照试验

    doi:10.1097/RLI.0000000000000121

    authors: Jacobs C,van Rikxoort EM,Scholten ET,de Jong PA,Prokop M,Schaefer-Prokop C,van Ginneken B

    更新日期:2015-03-01 00:00:00

  • Incidence and methods of diagnosis of musculoskeletal injuries incurred in Operations Desert Shield and Desert Storm.

    abstract:RATIONALE AND OBJECTIVES:The authors studied the incidence and distribution of orthopedic injuries sustained in Operation Desert Shield and Desert Storm by evaluating whether existing diagnostic imaging modalities were sufficient to diagnose the types of musculoskeletal injuries incurred. The authors also sought to det...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199703000-00006

    authors: Truax AL,Chandnani VP,Chacko AK,Gonzalez DM

    更新日期:1997-03-01 00:00:00

  • Right-Angled Traction Bronchiectasis in Differentiating Idiopathic Pulmonary Fibrosis Without Honeycombing From Idiopathic Nonspecific Interstitial Pneumonia.

    abstract:OBJECTIVES:The aim of this study was to conduct a radiopathologic evaluation of right-angled traction bronchiectasis to differentiate idiopathic pulmonary fibrosis (IPF) without honeycombing from idiopathic nonspecific interstitial pneumonia (NSIP). MATERIALS AND METHODS:The derivation cohort included 78 consecutive p...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000651

    authors: Kim H,Yoon SH,Lee HJ,Song SG,Koh J,Jeon YK,Chae KJ,Jin GY,Jin KN,Lee KY,Goo JM

    更新日期:2020-06-01 00:00:00

  • Changes in complement and coagulation factors in a patient suffering a severe anaphylactoid reaction to injected contrast material: some considerations of pathogenesis.

    abstract::A patient, suffering a severe anaphylactoid reaction to contrast material injected for an intravenous pyelogram, developed a consumption coagulopathy and evidence of complement activation. Precontrast complement values suggested that the patient had been processing complement via the classical pathway, perhaps as a co...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198011001-00004

    authors: Lasser EC,Lang JH,Lyon SG,Hamblin AE

    更新日期:1980-11-01 00:00:00

  • Auditory cortex activation in deaf subjects during cochlear electrical stimulation. Evaluation by functional magnetic resonance imaging.

    abstract:RATIONALE AND OBJECTIVES:The authors detect activation in the auditory cortex during cochlear electrical stimulation in deaf patients using functional magnetic resonance (MR) imaging. METHODS:Stimulating electrode was inserted gently under local anesthesia close to the round window membrane of the cochlea in seven coc...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199705000-00007

    authors: Berthezène Y,Truy E,Morgon A,Giard MH,Hermier M,Franconi JM,Froment JC

    更新日期:1997-05-01 00:00:00

  • Hepatic kinetics and magnetic resonance imaging of gadolinium-EOB-DTPA in dogs.

    abstract:RATIONALE AND OBJECTIVES:To measure the hepatic uptake and biliary elimination kinetics of gadolinium (Gd)-EOB-DTPA in dogs. METHOD:Two groups of four beagles each were anesthetized and given an intravenous bolus of 25 mumol/kg or 250 mumol/kg of Gd-EOB-DTPA. Blood, hepatic bile, and urine were collected over 140 minu...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199604000-00005

    authors: Benness G,Khangure M,Morris I,Warwick A,Burrows P,Vogler H,Weinmann HJ

    更新日期:1996-04-01 00:00:00

  • Tamm-Horsfall glycoprotein excretion and aggregation during intravenous urography. Relevance to acute renal failure.

    abstract::The effect of intravenous urography (IVU) on the excretion rate and precipitation of Tamm-Horsfall glycoprotein (THG) has been evaluated in 19 patients. Urine samples were collected immediately before the administration of contrast medium (U1) and then during the period of the excretion urogram (U2). The urinary THG: ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198501000-00014

    authors: Dawnay AB,Thornley C,Nockler I,Webb JA,Cattell WR

    更新日期:1985-01-01 00:00:00

  • A direct comparison of noninvasive coronary angiography by electron beam tomography and navigator-echo-based magnetic resonance imaging for the detection of restenosis following coronary angioplasty.

    abstract:RATIONALE AND OBJECTIVES:To compare electron beam tomography (EBT) with MR imaging (MRI) for detection of restenosis after coronary angioplasty (PTCA). METHODS:One hundred eighteen patients after PTCA were investigated. By EBT, 50 axial images were acquired (3-mm slice thickness, 120-160 mL radiographic contrast agent...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-200207000-00005

    authors: Ropers D,Regenfus M,Stilianakis N,Birke S,Kessler W,Moshage W,Laub G,Daniel WG,Achenbach S

    更新日期:2002-07-01 00:00:00

  • Contrast media-induced chromosomal damage in human lymphocyte cultures.

    abstract::Ionic (diatrizoate, ioxaglate) and nonionic (iohexol, iosimide, iopromide, and iotrolan) contrast media (CM) were evaluated for their cytogenetic effects in lymphocytes. Heparinized blood was mixed with culture medium RPMI-1640 supplemented with phytohemagglutinin, fetal calf serum, and antibiotics. Plastic tubes cont...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198611000-00006

    authors: Parvez Z,Kormano M,Moncada R,Eklund R

    更新日期:1986-11-01 00:00:00

  • Manganese dipyridoxyl diphosphate (MnDPDP)-enhanced magnetic resonance imaging of acute reperfused myocardial injury in a cat model: part I: comparison with pathologic examination.

    abstract:RATIONALE AND OBJECTIVES:To investigate the capacity of manganese dipyridoxyl diphosphate (MnDPDP)-enhanced magnetic resonance imaging (MRI) to discriminate the injured myocardium from the normal myocardium in a cat model. MATERIALS AND METHODS:Fourteen cats were prepared for acute myocardial infarction with 90-minute...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:

    authors: Kim TH,Yang DH,Choi JW,Kim ST,Yoon JH,Shin JH,Seo JB,Gong GY,Lim TH

    更新日期:2005-01-01 00:00:00

  • Air-filled ultrasound contrast agents do not damage the cerebral microvasculature or brain tissue in rats.

    abstract:RATIONALE AND OBJECTIVES:Air microemboli may damage the cerebral microvasculature. The aim of this study was to evaluate the safety of ultrasound contrast agents composed of air microspheres with regard to cerebral damage when administered into the arterial system (ie, when not filtered by the capillary system of the l...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199803000-00001

    authors: Haggag KJ,Russell D,Walday P,Skiphamn A,Torvik A

    更新日期:1998-03-01 00:00:00

  • Magnetic resonance imaging-guided percutaneous biopsy of mediastinal masses: diagnostic performance and safety.

    abstract:OBJECTIVE:The objective of this study was to evaluate the diagnostic performance and safety of magnetic resonance (MR) imaging-guided percutaneous mediastinal biopsy procedures using a 0.23-T open MR system with optical tracking navigation. MATERIALS AND METHODS:A retrospective analysis of 59 participants (38 males an...

    journal_title:Investigative radiology

    pub_type: 临床试验,杂志文章

    doi:10.1097/RLI.0b013e31827a4a17

    authors: Lü Y,Fritz J,Li C,Liu M,Lee P,Wu L,Carrino JA

    更新日期:2013-06-01 00:00:00

  • Stability of MRI paramagnetic contrast media: a proton relaxometric protocol for transmetallation assessment.

    abstract:RATIONALE AND OBJECTIVES:The suitability of paramagnetic complexes as magnetic resonance contrast agents depends on various factors such as their relaxivity, stability, selectivity, and the inertness toward transmetallation by endogenous ions. The transmetallation of a series of 18 gadolinium complexes by the Zn2+ ion ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-200102000-00008

    authors: Laurent S,Elst LV,Copoix F,Muller RN

    更新日期:2001-02-01 00:00:00

  • Comparison of left ventricular ejection fraction and regional contractility fraction pre and post coronary angiography.

    abstract::Thirty patients [four normals, eight with mild and 18 with severe coronary artery disease (CAD)] were studied to evaluate left ventricular function type and post coronary angiography. The end diastolic volume (EDV), end systolic volume (ESV), ejection fraction (EF) and the regional contractility fractions (RCF) of eig...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-197603000-00009

    authors: Sos TA,Baltaxe HA

    更新日期:1976-03-01 00:00:00

  • Helium3 polarization using spin exchange technique: application to simultaneous pulmonary ventilation/perfusion imaging in small animals.

    abstract:RATIONALE AND OBJECTIVES:To develop a simple and robust helium3 polarization system dedicated to small animal imaging. To demonstrate the potential of helium3 imaging for pulmonary ventilation and perfusion studies. METHODS:A home-built polarization system based on spin-exchange technique was used. This system was app...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:

    authors: Stupar V,Berthezène Y,Canet E,Tournier H,Dupuich D,Crémillieux Y

    更新日期:2003-06-01 00:00:00

  • Changes in portal hemodynamics and acute rejection in the first 2 weeks after orthotopic liver transplantation. A prospective Doppler ultrasound study.

    abstract:RATIONALE AND OBJECTIVES:To analyze changes in Doppler ultrasound variables of the portal vein in relation to liver biopsy findings, the authors performed a prospective study of 316 Doppler ultrasound examinations in the first 2 weeks after orthotopic liver transplantation on 23 patients. METHODS:Recordings were obtai...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199612000-00007

    authors: Kok T,Slooff MJ,Peeters PM,Zwaveling JH,Bijleveld CM,Gi-van Loon CE,Klompmaker IJ,Haagsma EB

    更新日期:1996-12-01 00:00:00

  • Design of an isolated pig heart preparation for positron emission tomography and magnetic resonance imaging.

    abstract:RATIONALE AND OBJECTIVES:Validation of new positron emission tomography (PET) tracers or magnetic (MR) imaging contrast agents is based on isolated rodent heart preparations. The use of larger animals could provide a more direct validation using the devices used for humans. METHODS:An isolated pig heart preparation ha...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199711000-00010

    authors: Casali C,Obadia JF,Canet E,Bendjelid K,André-Fouët X,Revel D,Janier MF

    更新日期:1997-11-01 00:00:00

  • The effect of computed tomographic scan orientation on information loss in the three-dimensional reconstruction of tripod zygomatic fractures.

    abstract::Fractures modeled in the dried skull indicate that the initial plane of computed tomography (CT) section contributes to the accuracy of three-dimensional (3D) images generated from two-dimensional (2D) CT data. The authors retrospectively analyzed seven clinical cases of tripod zygomatic fractures that were imaged wit...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199105000-00009

    authors: Levy RA,Kellman RM,Rosenbaum AE

    更新日期:1991-05-01 00:00:00

  • Sensitivity to detect small coronary artery calcium lesions with varying slice thickness using electron beam tomography.

    abstract:RATIONALE AND OBJECTIVE:To estimate the sensitivity to find small coronary artery calcium lesions with use of different slice widths with electron beam tomography. MATERIALS AND METHODS:Two studies were performed. Study 1 utilized double scanning of a stationary cork phantom with three different slice thickness (1.5, ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/01.RLI.0000055289.97726.B1

    authors: Mao S,Child J,Carson S,Liu SC,Oudiz RJ,Budoff MJ

    更新日期:2003-03-01 00:00:00

  • Safety and Oncologic Outcomes of Magnetic Resonance Imaging-Guided Cryoablation of Renal Cell Carcinoma: A 10-Year Single-Center Experience.

    abstract:OBJECTIVES:Magnetic resonance imaging guidance has been sporadically reported for renal tumor cryoablation (CA); therefore, clinical experience with this modality is still limited.The aim of this study is to retrospectively analyze our 10-year experience with renal tumor CA performed on a 1.5 T magnetic resonance imagi...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000719

    authors: Cazzato RL,De Marini P,Leonard-Lorant I,Leclerc L,Auloge P,Tricard T,Dalili D,Garnon J,Lang H,Gangi A

    更新日期:2020-09-04 00:00:00

  • In-vitro assessment of the behavior of magnetic resonance angiography in the presence of constrictions.

    abstract:RATIONALE AND OBJECTIVES:Time-of-flight magnetic resonance angiography (TOF/MRA) is increasingly used to assess the nature and severity of stenotic blood vessels. Flow artifacts associated with high flows and/or narrow constrictions may confuse the interpretation of these studies. Accurate TOF/MRA evaluations demand an...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199307000-00011

    authors: Sebok NR,Sebok DA,Wilkerson D,Mezrich RS,Zatina M

    更新日期:1993-07-01 00:00:00

  • Gadobutrol-enhanced, three-dimensional, dynamic MR imaging with MR cholangiography for the preoperative evaluation of bile duct cancer.

    abstract:PURPOSE:To evaluate the diagnostic performance of 1.0-M gadobutrol-enhanced, 3-dimensional (3D), dynamic MR images with 3D-MR cholangiography (MRC) in the preoperative evaluation of bile duct cancer staging and resectability. MATERIALS AND METHODS:Our institutional review board approved this retrospective study. Sixty...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e3181d2eeb1

    authors: Ryoo I,Lee JM,Chung YE,Park HS,Kim SH,Han JK,Choi BI

    更新日期:2010-04-01 00:00:00

  • Ultrasonic echoes registered from erythrocytes.

    abstract::Erythrocytes at various concentrations were examined with a sensitive A-mode ultrasonic scanner; simultaneous measurements were made under light microscopic control. Individual erythrocytes caused weak (about 1 dB) echoes while erythrocyte aggregates (ten to 100 cells) produced stronger echoes (up to 15 dB), grossly p...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198508000-00014

    authors: Alanen A,Kormano M

    更新日期:1985-08-01 00:00:00

  • Image Quality and Geometric Distortion of Modern Diffusion-Weighted Imaging Sequences in Magnetic Resonance Imaging of the Prostate.

    abstract:PURPOSE:The aim of this study was to compare qualitative and quantitative image quality and geometric distortion of 4 magnetic resonance diffusion-weighted imaging (DWI) sequences of the prostate using comparable imaging parameters and similar acquisition times. METHODS AND MATERIALS:Axial T2-weighted turbo spin echo ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000429

    authors: Stocker D,Manoliu A,Becker AS,Barth BK,Nanz D,Klarhöfer M,Donati OF

    更新日期:2018-04-01 00:00:00

  • First-in-Human Ultrasound Molecular Imaging With a VEGFR2-Specific Ultrasound Molecular Contrast Agent (BR55) in Prostate Cancer: A Safety and Feasibility Pilot Study.

    abstract:OBJECTIVE:BR55, a vascular endothelial growth factor receptor 2 (VEGFR2)-specific ultrasound molecular contrast agent (MCA), has shown promising results in multiple preclinical models regarding cancer imaging. In this first-in-human, phase 0, exploratory study, we investigated the feasibility and safety of the MCA for ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000362

    authors: Smeenge M,Tranquart F,Mannaerts CK,de Reijke TM,van de Vijver MJ,Laguna MP,Pochon S,de la Rosette JJMCH,Wijkstra H

    更新日期:2017-07-01 00:00:00

  • A computer program for the localization of small areas in roentgenological images.

    abstract::A method and associated algorithm are presented which allow a simple and accurate determination to be made of the location of small symmetric areas presented in roentgenological images. The method utilizes an operator to visually spot object positions but eliminates the need for critical positoning accuracy on the ope...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-197603000-00007

    authors: Keller RA,Baily NA

    更新日期:1976-03-01 00:00:00

  • Targeted-microbubble binding selectively to GPIIb IIIa receptors of platelet thrombi.

    abstract:RATIONALE AND OBJECTIVES:New targeted microbubbles directed to the GPIIb IIIa receptor have been developed. The objective was to determine whether targeting microbubbles to clots would enhance ultrasound imaging. Systematic studies were designed to determine whether in vitro methodology is an acceptable predictor of in...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-200211000-00001

    authors: Schumann PA,Christiansen JP,Quigley RM,McCreery TP,Sweitzer RH,Unger EC,Lindner JR,Matsunaga TO

    更新日期:2002-11-01 00:00:00