Facilitated Diagnosis of Pneumothoraces in Newborn Mice Using X-ray Dark-Field Radiography.

Abstract:

OBJECTIVE:The aim of this study was to evaluate the diagnostic value of x-ray dark-field imaging in projection radiography-based depiction of pneumothoraces in the neonatal murine lung, a potentially life-threatening medical condition that requires a timely and correct diagnosis. MATERIALS AND METHODS:By the use of a unique preclinical model, 7-day-old C57Bl/6N mice received mechanical ventilation for 2 or 8 hours with oxygen-rich gas (FIO2 = 0.4; n = 24). Unventilated mice either spontaneously breathed oxygen-rich gas (FIO2 = 0.4) for 2 or 8 hours or room air (n = 22). At the end of the experiment, lungs were inflated with a standardized volume of air after a lethal dose of pentobarbital was administered to the pups. All lungs were imaged with a prototype grating-based small-animal scanner to acquire x-ray transmission and dark-field radiographs. Image contrast between the air-filled pleural space and lung tissue was quantified for both transmission and dark-field radiograms. After the independent expert's assessment, 2 blinded readers evaluated all dark-field and transmission images for the presence or absence of pneumothoraces. Contrast ratios, diagnostic accuracy, as well as reader's confidence and interreader agreement were recorded for both imaging modalities. RESULTS:Evaluation of both x-ray transmission and dark-field radiographs by independent experts revealed the development of a total of 10 pneumothoraces in 8 mice. Here, the contrast ratio between the air-filled pleural space of the pneumothoraces and the lung tissue was significantly higher in the dark field (8.4 ± 3.5) when compared with the transmission images (5.1 ± 2.8; P < 0.05). Accordingly, the readers' diagnostic confidence for the diagnosis of pneumothoraces was significantly higher for dark-field compared with transmission images (P = 0.001). Interreader agreement improved from moderate for the analysis of transmission images alone (κ = 0.41) to very good when analyzing dark-field images alone (κ = 0.90) or in combination with transmission images (κ = 0.88). Diagnostic accuracy significantly improved for the analysis of dark-field images alone (P = 0.04) or in combination with transmission images (P = 0.02), compared with the analysis of transmission radiographs only. CONCLUSIONS:The significant improvement in contrast ratios between lung parenchyma and free air in the dark-field images allows the facilitated detection of pneumothoraces in the newborn mouse. These preclinical experiments indicate the potential of the technique for future clinical applications.

journal_name

Invest Radiol

journal_title

Investigative radiology

authors

Hellbach K,Yaroshenko A,Willer K,Pritzke T,Baumann A,Hesse N,Auweter S,Reiser MF,Eickelberg O,Pfeiffer F,Hilgendorff A,Meinel FG

doi

10.1097/RLI.0000000000000285

subject

Has Abstract

pub_date

2016-10-01 00:00:00

pages

597-601

issue

10

eissn

0020-9996

issn

1536-0210

pii

00004424-201610000-00001

journal_volume

51

pub_type

杂志文章
  • Heavily Calcified Coronary Arteries: Advanced Calcium Subtraction Improves Luminal Visualization and Diagnostic Confidence in Dual-Energy Coronary Computed Tomography Angiography.

    abstract:OBJECTIVES:The aim of this study was to evaluate a prototype dual-energy computed tomography calcium subtraction algorithm and its impact on luminal visualization in patients with heavily calcified coronary arteries. MATERIALS AND METHODS:Twenty-nine patients (62% male; mean age, 64 ± 7 years) who had undergone dual-e...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000416

    authors: De Santis D,Jin KN,Schoepf UJ,Grant KL,De Cecco CN,Nance JW Jr,Vogl TJ,Laghi A,Albrecht MH

    更新日期:2018-02-01 00:00:00

  • Effect of multiple intravenous injections of diatrizoate on iodine concentrations and osmolality. An experimental study in rabbits.

    abstract::Multiple intravenous injections of contrast media are used in radiology, but information regarding corresponding changes in the serum iodine concentrations and osmolality is lacking. We measured the changes in serum iodine concentration and serum osmolality in rabbits after a series of intravenous injections of contra...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198703000-00007

    authors: Rubin DI,Kido DK,Morris TW,Fischer HW

    更新日期:1987-03-01 00:00:00

  • Expert learning system network for diagnosis of breast calcifications.

    abstract::Breast calcification diagnosis was studied by using clinical findings and computerized image processing of a mammogram in a network of trained expert learning systems (Outcome Advisor [OA]). The system was tested with records not used for training and performance was compared with radiologist. The network was 72% accu...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199106000-00004

    authors: Patrick EA,Moskowitz M,Mansukhani VT,Gruenstein EI

    更新日期:1991-06-01 00:00:00

  • Pediatric angiocardiography with iohexol.

    abstract::A nonionic contrast medium (iohexol) was evaluated for safety and efficacy in pediatric angiocardiography in this study of 15 patients, age 6 to 82 months. Patients carried a preliminary diagnosis of congenital heart disease. Subjects were injected with iohexol, 350 mg iodine/ml of solution with an average volume of 2...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:

    authors: Carlsson EC,Rudolph A,Stanger P,Teitel D,Weber W,Yoshida H

    更新日期:1985-01-01 00:00:00

  • Slice simulation from a model of the parenchymous vascularization to evaluate texture features: work in progress.

    abstract:RATIONALE AND OBJECTIVES:To demonstrate the usefulness of a model of the parenchymous vascularization to evaluate texture analysis methods. METHODS:Slices with thickness varying from 1 to 4 mm were reformatted from a 3D vascular model corresponding to either normal tissue perfusion or local hypervascularization. Param...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199903000-00004

    authors: Rolland Y,Bézy-Wendling J,Duvauferrier R,Coatrieux JL

    更新日期:1999-03-01 00:00:00

  • The role of catheters and guidewires in the production of angiographic thromboembolic complications.

    abstract::Thromboembolic complications occurring during angiography may result from a number of different causes. Catheters and guidewires can interact with blood to form thrombi; this tendency is related to wall defects and the chemical composition and structural characteristics of the catheters and guidewires. Nonthrombic sou...

    journal_title:Investigative radiology

    pub_type: 杂志文章,评审

    doi:10.1097/00004424-198811002-00009

    authors: Kido DK,King PD,Manzione JV,Simon JH

    更新日期:1988-11-01 00:00:00

  • Multiphase magnetic resonance angiography of the abdominal and pelvic arteries: results of a bicenter multireader analysis.

    abstract:RATIONALE AND OBJECTIVES:The objective is to assess the diagnostic accuracy and interobserver variability of multiphase 3D gadolinium-enhanced magnetic resonance angiography (3D-Gd-MRA) for assessment of abdominal and pelvic vascular disease. METHODS:In 41 patients from two different institutions multiphase 3D-Gd-MRA ...

    journal_title:Investigative radiology

    pub_type: 杂志文章,多中心研究

    doi:10.1097/00004424-200201000-00005

    authors: Schoenberg SO,Essig M,Hallscheidt P,Sharafuddin MJ,Stolpen AH,Knopp MV,Yuh WT

    更新日期:2002-01-01 00:00:00

  • Contrast-detail phantom study for x-ray spectrum optimization regarding chest radiography using a cesium iodide-amorphous silicon flat-panel detector.

    abstract:RATIONALE AND OBJECTIVES:The purpose of this study evaluating a cesium iodide-amorphous silicon-based flat-panel detector was to optimize the x-ray spectrum for chest radiography combining excellent contrast-detail visibility with reduced patient exposure. MATERIALS AND METHODS:A Lucite plate with 36 drilled holes of ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/01.rli.0000138091.96320.f8

    authors: Hamer OW,Völk M,Zorger N,Borisch I,Büttner R,Feuerbach S,Strotzer M

    更新日期:2004-10-01 00:00:00

  • Binary nature and radiographic identifiability of craniosynostosis.

    abstract:RATIONALE AND OBJECTIVES:Two independent gold standards and diagnoses from three-dimensional computed tomography (CT) images were used to examine the possibility that craniosynostosis is a binary abnormality that potentially may be diagnosed without error. METHODS:Surgical reports, histology of excised sutures, and th...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199410000-00005

    authors: Pilgram TK,Vannier MW,Marsh JL,Kraemer BB,Rayne SC,Gado MH,Moran CJ,McAlister WH,Shackelford GD,Hardesty RA

    更新日期:1994-10-01 00:00:00

  • Value of in vivo T2 measurement for myocardial fibrosis assessment in diabetic mice at 11.75 T.

    abstract:OBJECTIVE:The aim of the study was to assess the value of in vivo T2 measurements to noninvasively quantify myocardial fibrosis in diabetic mice at 11.75 T. Diabetic cardiomyopathy is characterized by extracellular matrix alteration and microcirculation impairment. These conditions might provide electrical heterogeneit...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e318243e062

    authors: Bun SS,Kober F,Jacquier A,Espinosa L,Kalifa J,Bonzi MF,Kopp F,Lalevee N,Zaffran S,Deharo JC,Cozzone PJ,Bernard M

    更新日期:2012-05-01 00:00:00

  • Clinical safety and diagnostic value of the gadolinium chelate gadoterate meglumine (Gd-DOTA).

    abstract:OBJECTIVE:The purpose of this study was to assess the diagnostic value and safety of the contrast agent gadoterate meglumine (Gd-DOTA, DOTAREM, Guerbet, Roissy CdG Cedex, France) in the setting of a postmarketing surveillance study. MATERIALS AND METHODS:Between January 2004 and October 2005, radiologists in 61 radiol...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/01.rli.0000248893.01067.e5

    authors: Herborn CU,Honold E,Wolf M,Kemper J,Kinner S,Adam G,Barkhausen J

    更新日期:2007-01-01 00:00:00

  • 18F-Fluorodeoxyglucose Positron Emission Tomography/Magnetic Resonance in Lymphoma: Comparison With 18F-Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography and With the Addition of Magnetic Resonance Diffusion-Weighted Imaging.

    abstract:OBJECTIVES:The aim of this study was to compare F-fluorodeoxyglucose (FDG) positron emission tomography (PET)/magnetic resonance (MR) (with and without diffusion-weighted imaging [DWI]) to F-FDG PET/computed tomography (CT), with regard to the assessment of nodal and extranodal involvement, in patients with Hodgkin lym...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000218

    authors: Giraudo C,Raderer M,Karanikas G,Weber M,Kiesewetter B,Dolak W,Simonitsch-Klupp I,Mayerhoefer ME

    更新日期:2016-03-01 00:00:00

  • Nonparametric estimation of degenerate ROC data sets used for comparison of imaging systems.

    abstract::Maximum likelihood estimation, assuming a binormal model, has been used extensively to estimate the area under receiver operating characteristic (ROC) curves and thus provide an index of diagnostic accuracy for the comparison of two imaging systems. However, in some instances, a degenerate data set results in a fitted...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199007000-00016

    authors: Rockette HE,Obuchowski NA,Gur D

    更新日期:1990-07-01 00:00:00

  • Thirty-two-channel coil 3T magnetic resonance-guided biopsies of prostate tumor suspicious regions identified on multimodality 3T magnetic resonance imaging: technique and feasibility.

    abstract:OBJECTIVES:To test the technique and feasibility of translating tumor suspicious region maps in the prostate, obtained by multimodality, anatomic, and functional 3T magnetic resonance imaging (MRI) data to 32-channel coil, T2-weighted (T2-w), 3T MR images, for directing MR-guided biopsies. Furthermore, to evaluate the ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e31817d0506

    authors: Hambrock T,Fütterer JJ,Huisman HJ,Hulsbergen-vandeKaa C,van Basten JP,van Oort I,Witjes JA,Barentsz JO

    更新日期:2008-10-01 00:00:00

  • Direct video-microscopic observation of the dynamic effects of medical ultrasound on ultrasound contrast microspheres.

    abstract:RATIONALE AND OBJECTIVES:Ultrasound can cause destruction of microbubble contrast agents used to enhance medical ultrasound imaging. This study sought to characterize the dynamics of this interaction by direct visual observation of microbubbles during insonification in vitro by a medical ultrasound imaging system. MET...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199812000-00004

    authors: Klibanov AL,Ferrara KW,Hughes MS,Wible JH Jr,Wojdyla JK,Dayton PA,Morgan KE,Brandenburger GH

    更新日期:1998-12-01 00:00:00

  • Large-tip-angle spin-echo imaging. Theory and applications.

    abstract:RATIONALE AND OBJECTIVES:Tissue contrast phenomenology was investigated analytically and clinically for a class of magnetic resonance (MR) pulse sequences we call large-tip-angle (LTA) spin-echo (SE) imaging. In comparison to traditional SE sequences (denoted 90 degrees-180 degrees-echo), the LTA sequence is of the for...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199310000-00017

    authors: Elster AD,Provost TJ

    更新日期:1993-10-01 00:00:00

  • Three-dimensional ultrashort echo time imaging of solid polymers on a 3-Tesla whole-body MRI scanner.

    abstract:OBJECTIVE:With the introduction of ultrashort echo time (UTE) sequences solid polymeric materials might become visible on clinical whole-body magnetic resonance (MR) scanners. The aim of this study was to characterize solid polymeric materials typically used for instruments in magnetic resonance guided interventions an...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e318188601f

    authors: Springer F,Martirosian P,Schwenzer NF,Szimtenings M,Kreisler P,Claussen CD,Schick F

    更新日期:2008-11-01 00:00:00

  • Critical Questions Regarding Gadolinium Deposition in the Brain and Body After Injections of the Gadolinium-Based Contrast Agents, Safety, and Clinical Recommendations in Consideration of the EMA's Pharmacovigilance and Risk Assessment Committee Recommend

    abstract::For magnetic resonance, the established class of intravenous contrast media is the gadolinium-based contrast agents. In the 3 decades since initial approval, these have proven in general to be very safe for human administration. However, in 2006, a devastating late adverse reaction to administration of the less stable...

    journal_title:Investigative radiology

    pub_type: 杂志文章,评审

    doi:10.1097/RLI.0000000000000374

    authors: Runge VM

    更新日期:2017-06-01 00:00:00

  • Combined methods for assessment of neurotoxicity: testing of new nonionic radiographic media.

    abstract::A battery of tests for toxicity assessment of new contrast media is reviewed. Cell toxicity in a protozoan culture (Blepharisma americanum); lethal dose determination in mice; EEG Spectral analysis following cisternography in rabbits; ED50 and LD50 determination by intra- and pericerebral injection in rats; intraciste...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198011001-00053

    authors: Sovak M,Siefert HM,Ranganathan R

    更新日期:1980-11-01 00:00:00

  • Response of tumors to therapy studied by 31P magnetic resonance spectroscopy.

    abstract::Magnetic resonance (MR) methods have been used to study the metabolic and vascular response of model tumors to tumor necrosis factor (TNF). Magnetic resonance measurements demonstrated acute reductions in tumor blood flow, measured from tumor uptake of D2O, and in tumor adenosine triphosphate (ATP), measured by 31P ma...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198912000-00022

    authors: Karczmar GS,Meyerhoff DJ,Speder A,Valone F,Wilkinson M,Shine N,Boska MD,Weiner MW

    更新日期:1989-12-01 00:00:00

  • A new class of contrast agents for magnetic resonance imaging based on selective reduction of water-T2 by chemical exchange.

    abstract::Compounds containing mobile protons can act as contrast agents by increasing the value of the term (1/12 - 1/11). The efficiency of this method is markedly pH- and field-dependent. There are many such compounds allowing a choice to be made based on the characteristics of the tissue or organ, magnetic field strength, a...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198809001-00058

    authors: Aime S,Nano R,Grandi M

    更新日期:1988-09-01 00:00:00

  • Pharmacokinetics and safety of iomeprol in healthy volunteers and in patients with renal impairment or end-stage renal disease requiring hemodialysis.

    abstract:RATIONALE AND OBJECTIVES:To present the results of two studies conducted to evaluate the pharmacokinetics and safety of iomeprol in healthy volunteers and in patients with various degrees of renal impairment. METHODS:In these two open-label, single-dose, phase I studies, a 50-mL dose of iomeprol 400 was administered i...

    journal_title:Investigative radiology

    pub_type: 临床试验,杂志文章

    doi:10.1097/00004424-200106000-00002

    authors: Lorusso V,Taroni P,Alvino S,Spinazzi A

    更新日期:2001-06-01 00:00:00

  • Magnetic resonance imaging assays for dimethyl sulfoxide effect on cancer vasculature.

    abstract:OBJECTIVES:To evaluate the potential of quantitative assays of vascular characteristics based on dynamic contrast-enhanced magnetic resonance imaging (MRI) using a macromolecular contrast medium (MMCM) to search for and measure effects of dimethyl sulfoxide (DMSO) on cancer vasculature with microscopic correlations. M...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e318164b71d

    authors: Cyran CC,Sennino B,Chaopathomkul B,Fu Y,Rogut V,Shames DM,Wendland MF,McDonald DM,Brasch RC

    更新日期:2008-05-01 00:00:00

  • Brain tumor enhancement in magnetic resonance imaging: dependency on the level of protein binding of applied contrast agents.

    abstract:PURPOSE:To evaluate the dependency of tumor contrast enhancement (CE) in regard to protein-binding properties of contrast agents, using 4 different agents with a wide range of protein-binding capacities in a standardized rat brain glioma model. MATERIAL AND METHODS:Sixteen rats with implanted brain gliomas were evalua...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e318191a334

    authors: Wintersperger BJ,Runge VM,Tweedle MF,Jackson CB,Reiser MF

    更新日期:2009-02-01 00:00:00

  • 3.0 Tesla high spatial resolution contrast-enhanced magnetic resonance angiography (CE-MRA) of the pulmonary circulation: initial experience with a 32-channel phased array coil using a high relaxivity contrast agent.

    abstract:PURPOSE:To evaluate the technical feasibility of high spatial resolution contrast-enhanced magnetic resonance angiography (CE-MRA) with highly accelerated parallel acquisition at 3.0 T using a 32-channel phased array coil, and a high relaxivity contrast agent. MATERIALS AND METHODS:Ten adult healthy volunteers (5 men,...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/01.rli.0000261937.77365.6a

    authors: Nael K,Fenchel M,Krishnam M,Finn JP,Laub G,Ruehm SG

    更新日期:2007-06-01 00:00:00

  • The importance of end-systole for optimal reconstruction protocol of coronary angiography with 16-slice multidetector computed tomography.

    abstract:OBJECTIVES:Multidetector-row computed tomography coronary images are usually analyzed in mid-diastole (MD). Because of slow coronary motion also in end-systole (ES), we evaluated the impact on image quality of including ES images and defined an efficient reconstruction protocol. MATERIAL AND METHODS:In 50 coronary mul...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/01.rli.0000153930.34439.e4

    authors: Sanz J,Rius T,Kuschnir P,Fuster V,Goldberg J,Ye XY,Wisdom P,Poon M

    更新日期:2005-03-01 00:00:00

  • Contrast-enhanced magnetic resonance angiography of the carotid arteries: influence of injection rates and volumes on arterial-venous transit time.

    abstract:RATIONALE AND OBJECTIVES:To assess the influence of injection rates and volumes on the arrival time of contrast material (CM) in the common carotid artery, the jugular vein and the resulting arterial-venous transit time. Additionally the relationship between injection parameters and the extent of a CM plateau was evalu...

    journal_title:Investigative radiology

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1097/01.rli.0000105040.40925.c8

    authors: Herold T,Paetzel C,Völk M,Bachthaler M,Zorger N,Feuerbach S,Strotzer M,Lenhart M

    更新日期:2004-02-01 00:00:00

  • Biliary tract depiction in living potential liver donors at 3.0-T magnetic resonance cholangiography.

    abstract:OBJECTIVES:To prospectively evaluate accuracy of biliary anatomy depiction and quality of biliary tract visualization of magnetic resonance cholangiography (MRC) at 3.0 T in living potential liver donors (LPLDs). MATERIALS AND METHODS:Our institutional review board approved this study and did not require patient's inf...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e31817e9b52

    authors: Kim SY,Byun JH,Hong HS,Choi EK,Lee SS,Park SH,Lee MG

    更新日期:2008-08-01 00:00:00

  • Semiquantitative assessment of myocardial perfusion using magnetic resonance imaging: evaluation of appropriate thresholds and segmentation models.

    abstract:RATIONALE AND OBJECTIVES:The aim of the study was to determine optimal thresholds for semiquantitative perfusion parameters and to evaluate the influence of different segmentation models in detecting malperfused regions. MATERIAL AND METHODS:In 6 healthy subjects and 13 patients with coronary artery disease, contrast-...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/01.rli.0000133816.83192.38

    authors: Fenchel M,Kramer U,Helber U,Stauder NI,Franow A,Claussen CD,Miller S

    更新日期:2004-09-01 00:00:00

  • The allergic theory of radiocontrast agent toxicity: demonstration of antibody activity in sera of patients suffering major radiocontrast agent reactions.

    abstract::An allergic, immunologic mechanism for certain adverse reactions to radiocontrast agents has been postulated on the basis of clinical and theoretical considerations. One obstacle to the acceptance of this allergic theory has been the inability to demonstrate significant antibodies with specificity for these agents. In...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-197609000-00002

    authors: Brasch RC,Caldwell JL

    更新日期:1976-09-01 00:00:00