Microangiographic anatomy of the cat's eye.

Abstract:

:The microangiographic anatomy of the cat's eye is presented. The characteristic vascular pattern of each of the three distinct circulations, retinal choroidal, and ciliary is described and illustrated.

journal_name

Invest Radiol

journal_title

Investigative radiology

authors

Rothman SL,Kier EL,Deuker DK

doi

10.1097/00004424-197501000-00007

keywords:

subject

Has Abstract

pub_date

1975-01-01 00:00:00

pages

53-61

issue

1

eissn

0020-9996

issn

1536-0210

journal_volume

10

pub_type

杂志文章
  • Technical feasibility and performance studies of a 0.009-inch nitinol microguidewire for potential neuroendovascular applications.

    abstract:RATIONALE AND OBJECTIVES:The authors conduct technical feasibility and performance studies on a new 0.009-inch nitinol microguidewire for potential neuroendovascular applications. METHODS:In vivo microcatheterizations of brachiocephalic arteries were performed in four pigs using the 0.009-inch nitinol microguidewire w...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199704000-00008

    authors: Putman CM,Chaloupka JC,Kailasnath P,Alderman J

    更新日期:1997-04-01 00:00:00

  • Phase I clinical evaluation of citrate-coated monocrystalline very small superparamagnetic iron oxide particles as a new contrast medium for magnetic resonance imaging.

    abstract:RATIONALE AND OBJECTIVES:To evaluate the safety and pharmacokinetics of a newly developed MR contrast medium consisting of very small superparamagnetic iron oxide particles (VSOP) coated with citrate (VSOP-C184) in a clinical phase I trial. METHODS:A total of 18 healthy subjects received either VSOP-C184 (core diamete...

    journal_title:Investigative radiology

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1097/01.rli.0000129472.45832.b0

    authors: Taupitz M,Wagner S,Schnorr J,Kravec I,Pilgrimm H,Bergmann-Fritsch H,Hamm B

    更新日期:2004-07-01 00:00:00

  • Cellular uptake and trafficking of a prototypical magnetic iron oxide label in vitro.

    abstract:RATIONALE AND OBJECTIVES:Target-specific magnetic resonance (MR) contrast agents are being developed to improve the accuracy of MR imaging. The purpose of this study was to determine the mechanism of cell uptake, and modes of intracellular trafficking of a prototypical iron oxide label (RMA) used in the synthesis of so...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199510000-00006

    authors: Schulze E,Ferrucci JT Jr,Poss K,Lapointe L,Bogdanova A,Weissleder R

    更新日期:1995-10-01 00:00:00

  • Role of red blood cell deformation in toxicity of contrast media in cerebral angiography.

    abstract::The authors investigated the effect on the brain of red blood cells that had been modified by contrast media. Rat blood was mixed with an equivolume of contrast media, and up to 200 microL of the mixture was infused to the internal carotid artery of the rat. Evans blue was administered intravenously to assess the inte...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198905000-00009

    authors: Miyazawa T,Nakagawa H,Oshino N

    更新日期:1989-05-01 00:00:00

  • Collateral arterial formation. Lymph draining ischemic kidneys contains a neovascular stimulating agent of high molecular weight.

    abstract::An agent has been identified in lymph from rat kidneys rendered ischemic by partial renal artery occlusion that induces a striking neovascular response in a hamster cheek-pouch assay system. The factor has a high molecular weight, cannot be identified in lymph from normal kidneys, and is associated with a marked incre...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198501000-00015

    authors: Hollenberg NK,Paskins-Hurlburt AJ,Abrams HL

    更新日期:1985-01-01 00:00:00

  • Intracranial arteriovenous malformations. Current imaging and treatment.

    abstract::Patients with intracranial arteriovenous malformations (AVM) can expect significant mortality (15% to 20%) and morbidity (20% to 30%) over a 15-year to 20-year period. Recent advances in interventional neuroradiology, neurosurgery, neuroanesthesia, and stereotactic radiotherapy provide the opportunity to obliterate ma...

    journal_title:Investigative radiology

    pub_type: 杂志文章,评审

    doi:10.1097/00004424-199008000-00014

    authors: Graves VB,Duff TA

    更新日期:1990-08-01 00:00:00

  • Renal blood oxygenation level-dependent imaging: contribution of R2 to R2* values.

    abstract:OBJECTIVES:The aim of this study was to assess the impact of oral water and intravenous furosemide challenges on blood oxygenation level-dependent magnetic resonance imaging measurements in the kidney and to examine the contribution of R2 (=1/T2) to changes in R2* (=1/T2*). MATERIALS AND METHODS:This Health Insurance ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e3182823591

    authors: Vivier PH,Storey P,Chandarana H,Yamamoto A,Tantillo K,Khan U,Zhang JL,Sigmund EE,Rusinek H,Babb JS,Bubenheim M,Lee VS

    更新日期:2013-07-01 00:00:00

  • Microcomputer-based technique for 3-D reconstruction and volume measurement of computer tomographic images. Part 1: Phantom studies.

    abstract::This paper presents a microcomputer-based technique that accurately quantifies volumes from computed tomographic (CT) scans of irregularly shaped objects as well as displaying 3-D reconstructions. The method uses standard CT film, allowing analysis of previous or outside CT studies. The planimetry method showed less t...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198812000-00001

    authors: Albright RE Jr,Fram EK

    更新日期:1988-12-01 00:00:00

  • Radiofrequency balloon angioplasty. Rationale and proof of principle.

    abstract::Post-angioplasty restenosis (PARS) in atherosclerotic lesions of medium and small arteries occurs in about one-third of cases in the first year following percutaneous transluminal angioplasty (PTA) (early PARS). PARS includes acute spasm, dissection with reclosure, elastic recoil, fibrocellular proliferative response,...

    journal_title:Investigative radiology

    pub_type: 临床试验,杂志文章,多中心研究

    doi:10.1097/00004424-198811000-00002

    authors: Becker GJ,Lee BI,Waller BF,Barry KJ,Kaplan J,Connolly R,Dreesen RG,Nardella P

    更新日期:1988-11-01 00:00:00

  • Curriculum for musculoskeletal radiology.

    abstract::Although general suggestions have been made regarding a radiology residency curriculum, no specific list of entities has been offered. Over the past ten years, we have developed a resident-run morning conference in musculoskeletal radiology that is supervised by faculty and covers a specific curriculum. We offer our c...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199111000-00019

    authors: Renfrew DL,el-Khoury GY,Moore TE,Kathol MH,Whitten CG,Walker CW,Fraser-Hill MA

    更新日期:1991-11-01 00:00:00

  • Biodistribution and excretion of 125I ioversol in conscious dogs.

    abstract::Radiolabeled ioversol was injected intravenously into two male and two female beagle dogs (6.7 to 10.4 kg) at two dose levels each (0.2 and 1.0 g I/kg). Blood levels of radioactivity were monitored at 2, 5, 10, 20, 40, 60, 90, and 120 minutes and at one and two days. Urine and feces were collected in metabolism cages ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198906001-00005

    authors: Coveney JR,Robbins MS

    更新日期:1989-06-01 00:00:00

  • Arterial blood flow measurement: assessment of velocity estimation methods.

    abstract::Three methods are presented which provide statistically acceptable estimates of mean transit time of opacified blood during angiography. While the methods vary in precision, the selection of the method appropriate for any particular experimental model depends on the degree of precision required to demonstrate the effe...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-197707000-00004

    authors: Silverman NR,Rosen L

    更新日期:1977-07-01 00:00:00

  • Patient choice and nonionic contrast media.

    abstract:RATIONALE AND OBJECTIVES:Because of the greatly increased cost of nonionic, low-osmolar contrast material, some practitioners reserve its use for patients at high risk for an adverse contrast reaction. The authors attempt to evaluate the proportion of low-risk outpatients--when offered a choice between the more expensi...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199304000-00008

    authors: Hopper KD,Matthews YL

    更新日期:1993-04-01 00:00:00

  • Comparison of Power Versus Manual Injection in Bolus Shape and Image Quality on Contrast-Enhanced Magnetic Resonance Angiography: An Experimental Study in a Swine Model.

    abstract:OBJECTIVE:The aim of this study was to compare power versus manual injection in bolus shape and image quality on contrast-enhanced magnetic resonance angiography (CE-MRA). MATERIALS AND METHODS:Three types of CE-MRA (head-neck 3-dimensional [3D] MRA with a test-bolus technique, thoracic-abdominal 3D MRA with a bolus-t...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000383

    authors: Tsuboyama T,Jost G,Pietsch H,Tomiyama N

    更新日期:2017-09-01 00:00:00

  • Hemodynamic effect of iodinated high-viscosity contrast medium in the rat kidney: a diffusion-weighted MRI feasibility study.

    abstract:RATIONALE AND OBJECTIVES:To assess the abilities of dynamic diffusion-weighted MRI to demonstrate the effects in vivo of a high-viscosity iodinated contrast agent on medullary and cortical blood flow in the rat kidney. METHODS:Dynamic diffusion-weighted, echoplanar MR images obtained from five b-value single-shot acqu...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-200011000-00001

    authors: Laissy JP,Menegazzo D,Dumont E,Piekarski JD,Karila-Cohen P,Chillon S,Schouman-Claeys E

    更新日期:2000-11-01 00:00:00

  • Ultrasonic echoes registered from erythrocytes.

    abstract::Erythrocytes at various concentrations were examined with a sensitive A-mode ultrasonic scanner; simultaneous measurements were made under light microscopic control. Individual erythrocytes caused weak (about 1 dB) echoes while erythrocyte aggregates (ten to 100 cells) produced stronger echoes (up to 15 dB), grossly p...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198508000-00014

    authors: Alanen A,Kormano M

    更新日期:1985-08-01 00:00:00

  • Dual Plasma Sampling Method to Determine the Hepatic and Renal Clearance of the 2 Diastereoisomers of Gd-EOB-DTPA.

    abstract:OBJECTIVES:The aim of this study was to develop a method to determine hepatic and renal clearance of the 2 diastereoisomers (Gd-A, Gd-B) of Gd-EOB-DTPA separately. MATERIALS AND METHODS:Between July 2017 and February 2018, 41 patients with hepatic disease were prospectively included. For each patient, 1 mL of iopromid...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000622

    authors: Yuan X,Wang S,Shi W,Cai Y,Chen Y,Chen M,Peng Y,Ao G

    更新日期:2020-03-01 00:00:00

  • Effect of lumbar puncture on flow of cerebrospinal fluid.

    abstract::The rate at which isotopes descend from the cisterna magna to the lumbar subarachnoid space is highly variable. In monkeys, with and without previous lumbar puncture, transit time was measured. In animals with a previous lumbar puncture, transit times were 10 to 120 minutes; in monkeys without a previous lumbar punctu...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198805000-00005

    authors: Lipman B,Palmer D,Noble J,Haughton V,Collier D

    更新日期:1988-05-01 00:00:00

  • Adenosine-stress dynamic myocardial CT perfusion imaging: initial clinical experience.

    abstract:OBJECTIVE:To evaluate the feasibility of adenosine-stress dynamic myocardial volume perfusion imaging with second generation dual source computed tomography (CT) for the qualitative and quantitative assessment of myocardial blood flow (MBF) compared with stress perfusion and viability magnetic resonance imaging (MRI). ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e3181dfa2f2

    authors: Bastarrika G,Ramos-Duran L,Rosenblum MA,Kang DK,Rowe GW,Schoepf UJ

    更新日期:2010-06-01 00:00:00

  • Educational objectives for diagnostic radiology residency training.

    abstract::A method of teaching radiology residents by identification of general and specific objectives to be accomplished during each time segment of the four-year training program has been developed. The objectives are incorporated into an educational contract that is signed by the resident and rotation director at the beginn...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198612000-00009

    authors: Howland WJ,Marler D,Bosshart D

    更新日期:1986-12-01 00:00:00

  • Fibroblast response to gadolinium: role for platelet-derived growth factor receptor.

    abstract:OBJECTIVE:The purpose of this study was to assess the effects of gadolinium (Gd3+), provided as gadolinium chloride, on fibroblast function. MATERIALS AND METHODS:Human dermal fibroblasts in monolayer culture and intact skin in organ culture were exposed to the lanthanide metal (1-20 μM). RESULTS:Increased proliferat...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e3181e943d2

    authors: Bhagavathula N,Dame MK,DaSilva M,Jenkins W,Aslam MN,Perone P,Varani J

    更新日期:2010-12-01 00:00:00

  • Deep Learning on Conventional Magnetic Resonance Imaging Improves the Diagnosis of Multiple Sclerosis Mimics.

    abstract:OBJECTIVES:The aims of this study were to present a deep learning approach for the automated classification of multiple sclerosis and its mimics and compare model performance with that of 2 expert neuroradiologists. MATERIALS AND METHODS:A total of 268 T2-weighted and T1-weighted brain magnetic resonance imagin scans ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000735

    authors: Rocca MA,Anzalone N,Storelli L,Del Poggio A,Cacciaguerra L,Manfredi AA,Meani A,Filippi M

    更新日期:2020-10-26 00:00:00

  • Diatrizoate contrast agents: 2-amino-5-acetamido-, and 3,5-diamino-2,4,6-triiodobenzoates.

    abstract::We have examined the metabolic behavior of several triiodobenzoic acid derivatives because of the observed mutagenicity and cytotoxicity of 3-amino-5-acetamido-2,4,6-triiodobenzoate (I) and 3,5-diamino-2,4,6-triiodobenzoate (II). Measurements were facilitated using iodine-131 (131I)-labeled compounds. Drug retention i...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:

    authors: Weiss R,Hsu B,Wheeler L,Norman A,Riley RF

    更新日期:1981-11-01 00:00:00

  • The night stalker effect: quality improvements with a dedicated night-call rotation.

    abstract:RATIONALE AND OBJECTIVES:The authors assessed whether a non-sleep-deprived, second-year diagnostic radiology resident assigned to an after-hours "night stalker" emergency radiology (ER) rotation in an urban university hospital has a measurable impact on the number and clinical significance of "missed" radiologic findin...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199301000-00032

    authors: Mann FA,Danz PL

    更新日期:1993-01-01 00:00:00

  • Characterization of radial forces in Z stents.

    abstract:RATIONAL AND OBJECTIVES:The purpose of this study was to evaluate the effects of variation in design parameters on the resultant radial force. We evaluated the influence of wire gauge, leg length, and number of bends on the radial force produced by z stents and compared these with radial forces produced by commercial s...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-200109000-00004

    authors: Snowhill PB,Nosher JL,Siegel RL,Silver FH

    更新日期:2001-09-01 00:00:00

  • Whole-body diffusion-weighted imaging with apparent diffusion coefficient mapping for treatment response assessment in patients with diffuse large B-cell lymphoma: pilot study.

    abstract:OBJECTIVES:The aim of this pilot study was to assess post-treatment apparent diffusion coefficient (ADC) changes of diffuse large B-cell lymphoma lesions on respiratory-gated whole-body diffusion-weighted imaging (DWI), with integrated (18)F-fluoro-2-deoxyglucose positron emission tomography/computed tomography (PET/CT...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e3182087b03

    authors: Lin C,Itti E,Luciani A,Zegai B,Lin SJ,Kuhnowski F,Pigneur F,Gaillard I,Paone G,Meignan M,Haioun C,Rahmouni A

    更新日期:2011-05-01 00:00:00

  • Evaluation of postprocessing dual-energy methods in quantitative computed tomography. Part 2. Practical aspects.

    abstract::Three facets of dual-energy quantitative computed tomography are studied: (1) the algorithm for postprocessing data (the methods of Cann, Laval-Jeantet et al, Goodsitt et al [two methods], and Nickoloff et al); (2) the influence of choice of tissue-equivalent materials for calibration; and (3) the difference between c...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199008000-00003

    authors: van Kuijk C,Grashuis JL,Steenbeek JC,Schütte HE,Trouerbach WT

    更新日期:1990-08-01 00:00:00

  • Contrast-enhanced magnetic resonance angiography of the carotid arteries: influence of injection rates and volumes on arterial-venous transit time.

    abstract:RATIONALE AND OBJECTIVES:To assess the influence of injection rates and volumes on the arrival time of contrast material (CM) in the common carotid artery, the jugular vein and the resulting arterial-venous transit time. Additionally the relationship between injection parameters and the extent of a CM plateau was evalu...

    journal_title:Investigative radiology

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1097/01.rli.0000105040.40925.c8

    authors: Herold T,Paetzel C,Völk M,Bachthaler M,Zorger N,Feuerbach S,Strotzer M,Lenhart M

    更新日期:2004-02-01 00:00:00

  • The pediatric tracheostomy: III). An appraisal of xerography.

    abstract::Comparatively new in the roentgen evaluation of infants and children, xerography would appear to be ideal for portraying the pediatric airway. Since the radiation dose of xerography is higher than conventional radiography, its image quality is the subject of careful scrutiny in a pediatric setting here described in 23...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-197807000-00002

    authors: Scott JR,Kramer SS,Griscom NT

    更新日期:1978-07-01 00:00:00

  • Incompatibility of water-soluble contrast media and intravascular pharmacologic agents. An in vitro study.

    abstract::In vitro incompatibilities between nine water-soluble contrast media and 21 intravascular pharmacologic agents were investigated using naked-eye observation and a centrifuge. Most of the previously reported incompatibilities were verified, and a few new incompatibilities were discovered: phentolamine mesylate with dia...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199201000-00008

    authors: Kim SH,Lee HK,Han MC

    更新日期:1992-01-01 00:00:00