Phase I clinical evaluation of citrate-coated monocrystalline very small superparamagnetic iron oxide particles as a new contrast medium for magnetic resonance imaging.

Abstract:

RATIONALE AND OBJECTIVES:To evaluate the safety and pharmacokinetics of a newly developed MR contrast medium consisting of very small superparamagnetic iron oxide particles (VSOP) coated with citrate (VSOP-C184) in a clinical phase I trial. METHODS:A total of 18 healthy subjects received either VSOP-C184 (core diameter: 4 nm; total diameter: 7 +/- 0.15 nm; relaxivities in water at 0.47 T (T1) 18.7 and (T2) 30 L/(mmol*seconds)) at doses of 0.015, 0.045, or 0.075 mmol Fe/kg (n = 5 per dose) or placebo (n = 1 per dose) as intravenous injections. Physical status and vital parameters were recorded, blood samples were collected for clinical chemistry and relaxometry (0.94 T), and urinalyses were performed before and for up to 2 weeks after administration. RESULTS:No serious adverse events occurred. The most pronounced adverse events occurred in 2 subjects of the highest dose group 45-50 minutes after injection. These were a drop in blood pressure and a drop in oxygen saturation, which were considered to be possibly drug-related and rapidly resolved without medication. Otherwise, no relevant changes in vital and laboratory parameters were observed. The parameters of iron metabolism exhibited short-term, dose-related changes. The injection of VSOP-C184 decreased T1 relaxation time of blood below 100 milliseconds for 18 minutes after a dose of 0.045 mmol [corrected] Fe/kg and for 60 minutes after 0.075 mmol [corrected] Fe/kg. CONCLUSIONS:The favorable data on the safety, tolerability, and efficacy of VSOP-C184 justify further clinical phase II and III trials as a contrast medium for MRI.

journal_name

Invest Radiol

journal_title

Investigative radiology

authors

Taupitz M,Wagner S,Schnorr J,Kravec I,Pilgrimm H,Bergmann-Fritsch H,Hamm B

doi

10.1097/01.rli.0000129472.45832.b0

keywords:

subject

Has Abstract

pub_date

2004-07-01 00:00:00

pages

394-405

issue

7

eissn

0020-9996

issn

1536-0210

pii

00004424-200407000-00002

journal_volume

39

pub_type

临床试验,杂志文章,随机对照试验
  • The General Electric-Association of University Radiologists Radiology Research Academic Fellowship (GERRAF). An industry-academic collaboration to improve clinical research in radiology.

    abstract::The association of GE Medical Systems and the AUR represents a unique collaboration between academic radiology and industry that bears important potential for elevating the quality of clinical research in radiology and developing a cadre of high-quality radiologist researchers for the future. The establishment of the ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199305000-00001

    authors: Hillman BJ,Fryback DG,Holden RW,McNeil BJ,Molitor RM,Moss AA,Peck PV,Putman CE,Thompson WM

    更新日期:1993-05-01 00:00:00

  • A method for the study of regional ischemic dysfunction in the intact dog. Permanent endocardial markers and the pressure-length loop.

    abstract::A radiographic method for use in the closed-chest dog is described which allows the quantitation of segmental mechanical performance. Previous work has shown that the area of the pressure-length loop (an approximation of a stress-strain integral) is a useful measure of the mechanical work performed by a segment of myo...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-197611000-00010

    authors: Ringertz HG,Carlsson E,Tyberg JV

    更新日期:1976-11-01 00:00:00

  • Increased urine histamine and contrast media reactions.

    abstract::Urine samples were collected from 200 subjects undergoing intravenous pyelography. The urine histamine levels were compared with those of 132 normal control subjects, 11 subjects with systemic mastocytosis, six subjects with idiopathic anaphylaxis, and ten subjects experiencing mild anaphylactic reactions during aller...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198403000-00007

    authors: Kaliner M,Dyer J,Merlin S,Shelton A,Greenhill A,Treadwell G,McKenna W,Lieberman P

    更新日期:1984-03-01 00:00:00

  • Evaluation of gadolinium 2,5-BPA-DO3A, a new macrocyclic hepatobiliary chelate, in normal liver and metastatic disease on high field magnetic resonance imaging.

    abstract:RATIONALE AND OBJECTIVES:A new hepatobiliary gadolinium chelate, gadolinium (Gd) 2,5-BPA-DO3A, was compared in two animal species with Gd HP-DO3A (gadoteridol), a clinically approved extracellular contrast agent, and Gd Cy2-DOTA, a second hepatobiliary chelate in preclinical development. The ligand in Gd 2,5-BPA-DO3A i...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199601000-00003

    authors: Runge VM,Wells JW,Williams NM

    更新日期:1996-01-01 00:00:00

  • Magnetic resonance microscopy of the rat carotid artery at 300 megahertz.

    abstract:RATIONALE AND OBJECTIVES:Magnetic resonance microscopy (MRM) has evolved from a technical curiosity to a tool with which researchers can study important disease models. But MRM is not simply an extension of clinical magnetic resonance imaging. In this article, the unique adaptations of MRM required in the study of caro...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199409000-00004

    authors: Arnder L,Zhou X,Cofer GP,Hedlund LW,Johnson GA

    更新日期:1994-09-01 00:00:00

  • Delayed Gadolinium Leakage in Ocular Structures: A Potential Marker for Age- and Vascular Risk Factor-Related Small Vessel Disease?

    abstract:BACKGROUND:Gadolinium leakage in ocular structures (GLOS) was recently observed in fluid-attenuated inversion recovery (FLAIR) images obtained the day after an initial gadolinium injection in stroke patients. The specificity of GLOS to stroke and its mechanisms remain unclear. OBJECTIVE:We investigated the factors ass...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000757

    authors: Galmiche C,Moal B,Marnat G,Sagnier S,Schweitzer C,Dousset V,Sibon I,Tourdias T

    更新日期:2021-01-19 00:00:00

  • Ioversol clinical safety summary.

    abstract::The authors evaluated double-blind comparative and open-label clinical trials in 1,186 patients who received ioversol to evaluate the safety and efficacy of ioversol, a new nonionic low-osmolality contrast medium, at iodine concentrations of 32%, 24%, and 16%. The results indicate that ioversol was well tolerated in a...

    journal_title:Investigative radiology

    pub_type: 临床试验,杂志文章

    doi:10.1097/00004424-198906001-00020

    authors: Benamor M,Aten EM,McElvany KD,Lankin DG,James MA,Buy-Gandal T,Harashe LT,Weinandt WJ

    更新日期:1989-06-01 00:00:00

  • CTA contrast enhancement of the aorta and pulmonary artery: the effect of saline chase injected at two different rates in a canine experimental model.

    abstract:OBJECTIVE:To investigate the effect of saline chase injected at 2 different rates on computed tomography (CT) angiography. MATERIALS AND METHODS:This study was approved by our institutional animal study committee. Three injection protocols were used; contrast injection (24 mL, 0.8 mL/s) without saline chase (protocol ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e318032a9fe

    authors: Lee CH,Goo JM,Bae KT,Lee HJ,Kim KG,Chun EJ,Park CM,Im JG

    更新日期:2007-07-01 00:00:00

  • Assessment of cerebral blood flow in man by video dilution technique: a preliminary report.

    abstract::Video dilution technique (VDT) is currently performed in conjunction with routine cerebral angiography to determine carotid blood flow in humans. Preliminary results indicate that the blood flows (as a percentage of cardial output) of the common, internal, and external carotid arteries are 8.5%, 5.5%, and 3.0%, respec...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198105000-00004

    authors: Lantz BM,Dublin AB,McGahan JP,Link DP

    更新日期:1981-05-01 00:00:00

  • Computerized case-based instructional system for computed tomography and magnetic resonance imaging of brain tumors.

    abstract:RATIONALE AND OBJECTIVES:A computerized system that applies the case-based approach to training radiologists to diagnose brain tumors was designed. The authors attempted to provide residents a tool that supports their visual memory and inducts case-based reasoning. METHODS:A relational database with a digital image li...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199404000-00020

    authors: Macura RT,Macura KJ,Toro VE,Binet EF,Trueblood JH,Ji K

    更新日期:1994-04-01 00:00:00

  • Diatrizoate contrast agents: 2-amino-5-acetamido-, and 3,5-diamino-2,4,6-triiodobenzoates.

    abstract::We have examined the metabolic behavior of several triiodobenzoic acid derivatives because of the observed mutagenicity and cytotoxicity of 3-amino-5-acetamido-2,4,6-triiodobenzoate (I) and 3,5-diamino-2,4,6-triiodobenzoate (II). Measurements were facilitated using iodine-131 (131I)-labeled compounds. Drug retention i...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:

    authors: Weiss R,Hsu B,Wheeler L,Norman A,Riley RF

    更新日期:1981-11-01 00:00:00

  • Pediatric angiocardiography with iohexol.

    abstract::A nonionic contrast medium (iohexol) was evaluated for safety and efficacy in pediatric angiocardiography in this study of 15 patients, age 6 to 82 months. Patients carried a preliminary diagnosis of congenital heart disease. Subjects were injected with iohexol, 350 mg iodine/ml of solution with an average volume of 2...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:

    authors: Carlsson EC,Rudolph A,Stanger P,Teitel D,Weber W,Yoshida H

    更新日期:1985-01-01 00:00:00

  • Vascular alterations in canine histiocytic ulcerative colitis.

    abstract::The large intestines of eight boxer dogs with canine histiocytic ulcerative colitis (CHUC) and 10 normal dogs were studied by in vivo angiography and postmortem microangiography. The vascular abnormalities were correlated with the gross and histologic pathology found at necropsy. The angiographic abnormalities were ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-197505000-00005

    authors: Lawson TL,Gomez JA,Margulis AR

    更新日期:1975-05-01 00:00:00

  • Retention of iodine and expression of biomarkers for renal damage in the kidney after application of iodinated contrast media in rats.

    abstract:OBJECTIVE:Commercially available iodinated contrast media (CM) show significantly different physico-chemical properties. The relevance of the viscosity of CM may be underestimated as a contributing factor for clinically relevant renal failure as suggested by a large registry data analysis (Swedish registry study). The ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e318190fbd2

    authors: Jost G,Pietsch H,Sommer J,Sandner P,Lengsfeld P,Seidensticker P,Lehr S,Hütter J,Sieber MA

    更新日期:2009-02-01 00:00:00

  • Longitudinal Computed Tomography Monitoring of Pelvic Bones in Patients With Breast Cancer Using Automated Bone Subtraction Software.

    abstract:OBJECTIVE:The aim of this study was to optimize computed tomography (CT) surveillance of skeletal metastases in patients with breast cancer through the use of osseous subtraction maps between baseline and follow-up examinations created by a novel software algorithm. The new postprocessing algorithm segments the origina...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000343

    authors: Horger M,Thaiss WM,Wiesinger B,Ditt H,Fritz J,Nikolaou K,Kloth C

    更新日期:2017-02-01 00:00:00

  • In vitro complement consumption by contrast materials and analogues: reactors vs. nonreactors.

    abstract::Blood samples from previous contrast reactors and nonreactor controls were incubated with diatrizoate and several contrast analogues. Total complement levels were assayed. All the agents caused complement activation generally proportional to their concentration. Reactors' sera responded to lower concentrations of cont...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198307000-00018

    authors: Siegle RL,Lieberman P,Rice MC

    更新日期:1983-07-01 00:00:00

  • Evaluation of Gd-EOB-DTPA uptake in a perfused and isolated mouse liver model: correlation between magnetic resonance imaging and monochromatic quantitative computed tomography.

    abstract:OBJECTIVES:The aim of this work was to quantitatively evaluate the pharmacokinetic pattern of Gd-EOB-DTPA in a model of isolated and perfused mouse liver by using magnetic resonance imaging (MRI) and monochromatic quantitative computed tomography (MQCT). MATERIALS AND METHODS:For MQCT, perfusions were realized with th...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/01.rli.0000174474.43772.58

    authors: Segers J,Le Duc G,Laumonier C,Troprès I,Elst LV,Muller RN

    更新日期:2005-09-01 00:00:00

  • MR cholangiopancreatography at 3.0 T: intraindividual comparative study with MR cholangiopancreatography at 1.5 T for clinical patients.

    abstract:OBJECTIVES:To prospectively evaluate the image quality and diagnostic accuracy of magnetic resonance cholangiopancreatography (MRCP) at 3.0 T compared with that at 1.5 T used for patients. MATERIALS AND METHODS:This study was approved by our institutional review board, and informed consent was obtained from all patien...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e3181b4c0ae

    authors: Onishi H,Kim T,Hori M,Murakami T,Tatsumi M,Nakaya Y,Nakamoto A,Osuga K,Tomoda K,Nakamura H

    更新日期:2009-09-01 00:00:00

  • Pyrroxamide, a nonionic nitroxyl spin label contrast agent for magnetic resonance imaging. Mutagenesis and cell survival.

    abstract::Pyrroxamide [N-(1-hydroxymethyl-2,3-dihydroxypropyl)-2,2,5,5-tetramethyl pyrrolidine-1-oxyl-3-carboxyamide] is a newly tested nonionic monomeric nitroxyl compound with demonstrated effectiveness for MRI contrast enhancement at doses as low as 10(-3) M. Pyrroxamide and its hydroxylamine metabolic derivative were tested...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198808000-00013

    authors: Gordon DG,Brasch RC,Ogan MD,Deen D

    更新日期:1988-08-01 00:00:00

  • Contrast media tonicity. Part I. Effects upon IV-DSA time-concentration curve peak and width: experimental studies.

    abstract::Prior to the formation of an intravenous digital subtraction angiography (IV-DSA) image, contrast medium passes through the lesser circulation and is diluted by the blood volume of the heart and lungs. If the contrast medium alone influences central blood volume or cardiac output, the shape of the resultant time-conce...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198603000-00009

    authors: Burbank FH,Thompson WM

    更新日期:1986-03-01 00:00:00

  • Pancreatic Steatosis Is Associated With Impaired Exocrine Pancreatic Function.

    abstract:OBJECTIVES:The aim of this study was to investigate if pancreatic steatosis measured by proton density fat fraction (PDFF) is associated with exocrine pancreatic function defined by fecal elastase concentrations. MATERIALS AND METHODS:A total of 1458 volunteers (777 women; age range, 21-88 years) underwent magnetic re...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000554

    authors: Kromrey ML,Friedrich N,Hoffmann RT,Bülow R,Völzke H,Weiss FU,Lerch MM,Motosugi U,Kühn JP

    更新日期:2019-07-01 00:00:00

  • Activities of the Conjoint Committee. Enhancement of diagnostic radiologic research and education.

    abstract::Even though we have made much progress over the last decade, much still needs to be done. I am personally very pleased with the excellent management and authority of my coauthor, Joe Frank, in assuming the Acting Directorship of our DRRP. You will be hearing more from him in the immediate future about this research pr...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199304001-00014

    authors: Putman CE,Frank JA

    更新日期:1993-04-01 00:00:00

  • Nonparametric estimation of degenerate ROC data sets used for comparison of imaging systems.

    abstract::Maximum likelihood estimation, assuming a binormal model, has been used extensively to estimate the area under receiver operating characteristic (ROC) curves and thus provide an index of diagnostic accuracy for the comparison of two imaging systems. However, in some instances, a degenerate data set results in a fitted...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199007000-00016

    authors: Rockette HE,Obuchowski NA,Gur D

    更新日期:1990-07-01 00:00:00

  • Some practical issues of experimental design and data analysis in radiological ROC studies.

    abstract::Receiver operating characteristic (ROC) analysis has been used in a broad variety of medical imaging studies during the past 15 years, and its advantages over more traditional measures of diagnostic performance are now clearly established. But despite the essential simplicity of the approach, workers in the field ofte...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198903000-00012

    authors: Metz CE

    更新日期:1989-03-01 00:00:00

  • Hemodynamic effect of iodinated high-viscosity contrast medium in the rat kidney: a diffusion-weighted MRI feasibility study.

    abstract:RATIONALE AND OBJECTIVES:To assess the abilities of dynamic diffusion-weighted MRI to demonstrate the effects in vivo of a high-viscosity iodinated contrast agent on medullary and cortical blood flow in the rat kidney. METHODS:Dynamic diffusion-weighted, echoplanar MR images obtained from five b-value single-shot acqu...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-200011000-00001

    authors: Laissy JP,Menegazzo D,Dumont E,Piekarski JD,Karila-Cohen P,Chillon S,Schouman-Claeys E

    更新日期:2000-11-01 00:00:00

  • Magnetic resonance imaging assays for dimethyl sulfoxide effect on cancer vasculature.

    abstract:OBJECTIVES:To evaluate the potential of quantitative assays of vascular characteristics based on dynamic contrast-enhanced magnetic resonance imaging (MRI) using a macromolecular contrast medium (MMCM) to search for and measure effects of dimethyl sulfoxide (DMSO) on cancer vasculature with microscopic correlations. M...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e318164b71d

    authors: Cyran CC,Sennino B,Chaopathomkul B,Fu Y,Rogut V,Shames DM,Wendland MF,McDonald DM,Brasch RC

    更新日期:2008-05-01 00:00:00

  • Lung perfusion demonstrated by contrast-enhanced dynamic magnetic resonance imaging. Application to unilateral lung transplantation.

    abstract:RATIONALE AND OBJECTIVES:The authors evaluate the use of magnetic resonance (MR) to image pulmonary perfusion in healthy controls and to detect pulmonary defects in patients with unilateral lung transplantation, using dynamic images after contrast administration. METHODS:Five patients with right lung transplantation a...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199706000-00006

    authors: Berthezène Y,Croisille P,Bertocchi M,Houzard C,Bendib K,Revel D

    更新日期:1997-06-01 00:00:00

  • Right-Angled Traction Bronchiectasis in Differentiating Idiopathic Pulmonary Fibrosis Without Honeycombing From Idiopathic Nonspecific Interstitial Pneumonia.

    abstract:OBJECTIVES:The aim of this study was to conduct a radiopathologic evaluation of right-angled traction bronchiectasis to differentiate idiopathic pulmonary fibrosis (IPF) without honeycombing from idiopathic nonspecific interstitial pneumonia (NSIP). MATERIALS AND METHODS:The derivation cohort included 78 consecutive p...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000651

    authors: Kim H,Yoon SH,Lee HJ,Song SG,Koh J,Jeon YK,Chae KJ,Jin GY,Jin KN,Lee KY,Goo JM

    更新日期:2020-06-01 00:00:00

  • The effect of computed tomographic scan orientation on information loss in the three-dimensional reconstruction of tripod zygomatic fractures.

    abstract::Fractures modeled in the dried skull indicate that the initial plane of computed tomography (CT) section contributes to the accuracy of three-dimensional (3D) images generated from two-dimensional (2D) CT data. The authors retrospectively analyzed seven clinical cases of tripod zygomatic fractures that were imaged wit...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199105000-00009

    authors: Levy RA,Kellman RM,Rosenbaum AE

    更新日期:1991-05-01 00:00:00

  • Comparison of Power Versus Manual Injection in Bolus Shape and Image Quality on Contrast-Enhanced Magnetic Resonance Angiography: An Experimental Study in a Swine Model.

    abstract:OBJECTIVE:The aim of this study was to compare power versus manual injection in bolus shape and image quality on contrast-enhanced magnetic resonance angiography (CE-MRA). MATERIALS AND METHODS:Three types of CE-MRA (head-neck 3-dimensional [3D] MRA with a test-bolus technique, thoracic-abdominal 3D MRA with a bolus-t...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000383

    authors: Tsuboyama T,Jost G,Pietsch H,Tomiyama N

    更新日期:2017-09-01 00:00:00