Pediatric angiocardiography with iohexol.

Abstract:

:A nonionic contrast medium (iohexol) was evaluated for safety and efficacy in pediatric angiocardiography in this study of 15 patients, age 6 to 82 months. Patients carried a preliminary diagnosis of congenital heart disease. Subjects were injected with iohexol, 350 mg iodine/ml of solution with an average volume of 2.46 ml/kg of body weight at a rate of 9 to 14.5 ml/sec. The parameters evaluated included vital signs, intravascular BP, ECG changes, discomfort, and adverse reactions. No adverse reactions were noted in 14 of 15 patients. No significant changes in axillary temperature of ECG were observed. Intravascular blood pressure showed only moderate changes. After 24 hours, creatine phosphokinase (CPK) plasma concentrations increased significantly. Serum electrolytes remained unchanged. Image quality was deemed excellent considering variations in injection site and flow condition of the heart. Iohexol caused remarkably little discomfort and no adverse effects.

journal_name

Invest Radiol

journal_title

Investigative radiology

authors

Carlsson EC,Rudolph A,Stanger P,Teitel D,Weber W,Yoshida H

subject

Has Abstract

pub_date

1985-01-01 00:00:00

pages

S75-8

issue

1 Suppl

eissn

0020-9996

issn

1536-0210

journal_volume

20

pub_type

杂志文章
  • Personal computer needs for the radiologist.

    abstract::This article reviews the computer system hardware and software, applications programs, and computer network services that are available on microcomputers for use by the radiologist. The American College of Radiology Institute computer network is described, which is specifically designed to help the practicing radiolog...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198602000-00015

    authors: Newell JD,Hunter TB

    更新日期:1986-02-01 00:00:00

  • Experimental nephrotoxicity of the radiocontrast agents iohexol, ioxaglate, and iothalamate. An in vitro and in vivo study.

    abstract::The authors compared the renal toxicity of the low osmolality radiocontrast agents, iohexol and ioxaglate, and the ionic agent, iothalamate, at equivalent iodine dose, using experimental models in vitro and in vivo. In isolated perfused rat kidneys, all agents induced comparable biphasic hemodynamic changes, associate...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199104000-00008

    authors: Brezis M,Greenfeld Z,Herman M,Meyer JJ,Heyman SN,Rosen S

    更新日期:1991-04-01 00:00:00

  • Dynamic contrast-enhanced ultrasound for assessment of skeletal muscle microcirculation in peripheral arterial disease.

    abstract:OBJECTIVE:: This feasibility study was performed to assess whether dynamic contrast-enhanced ultrasound (CEUS) and transient arterial occlusion are able to detect alterations in the microvascular perfusion and arterial perfusion reserve in patients suffering from peripheral arterial disease (PAD) in comparison with hea...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e3182183a77

    authors: Amarteifio E,Weber MA,Wormsbecher S,Demirel S,Krakowski-Roosen H,Jöres A,Braun S,Delorme S,Böckler D,Kauczor HU,Krix M

    更新日期:2011-08-01 00:00:00

  • In vivo and in vitro evaluation of Gd-DTPA-polylysine as a macromolecular contrast agent for magnetic resonance imaging.

    abstract::Polylysine covalently linked to moieties of gadopentetate (Gd-DTPA), for use as a macromolecular blood pool marker for contrast material-enhanced magnetic resonance imaging (MRI), was characterized by means of physicochemical measurements and pharmacokinetics in rats and rabbits and compared with Gd-DTPA. Gd-DTPA-poly...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199111000-00008

    authors: Schuhmann-Giampieri G,Schmitt-Willich H,Frenzel T,Press WR,Weinmann HJ

    更新日期:1991-11-01 00:00:00

  • Bone mineral analysis using single-energy computed tomography.

    abstract::We present a new method for evaluating in vivo changes in bone mineralization in the peripheral skeleton, using computed tomography (CT). A set of bone mineralization indices are generated from numerous CT images of the patient's distal radius. The cross-sectional anatomy displayed by the CT scan allows for separate e...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-197903000-00003

    authors: Orphanoudakis SC,Jensen PS,Rauschkolb EN,Lang R,Rasmussen H

    更新日期:1979-03-01 00:00:00

  • Comparison of Gd(DTPA-BMA) (Omniscan) versus Gd(HP-DO3A) (ProHance) relative to gadolinium retention in human bone tissue by inductively coupled plasma mass spectroscopy.

    abstract:OBJECTIVE:The objective of this study was to determine the gadolinium (Gd) concentration remaining in human bone tissue after administration of standard clinical doses of 2 Gd-based contrast agents: ProHance and Omniscan. MATERIALS AND METHODS:After administration of 0.1 mmol/kg of Gd chelate to patients undergoing hi...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/01.rli.0000186569.32408.95

    authors: White GW,Gibby WA,Tweedle MF

    更新日期:2006-03-01 00:00:00

  • Magnetic resonance microscopy of the rat carotid artery at 300 megahertz.

    abstract:RATIONALE AND OBJECTIVES:Magnetic resonance microscopy (MRM) has evolved from a technical curiosity to a tool with which researchers can study important disease models. But MRM is not simply an extension of clinical magnetic resonance imaging. In this article, the unique adaptations of MRM required in the study of caro...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199409000-00004

    authors: Arnder L,Zhou X,Cofer GP,Hedlund LW,Johnson GA

    更新日期:1994-09-01 00:00:00

  • Image mottle in abdominal CT.

    abstract:RATIONALE AND OBJECTIVES:To investigate image mottle in conventional CT images of the abdomen as a function of radiographic technique factors and patient size. METHODS:Water-filled phantoms simulating the abdomens of adult (32 cm in diameter) and pediatric (16 cm in diameter) patients were used to investigate image mo...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199904000-00005

    authors: Ende JF,Huda W,Ros PR,Litwiller AL

    更新日期:1999-04-01 00:00:00

  • Direct video-microscopic observation of the dynamic effects of medical ultrasound on ultrasound contrast microspheres.

    abstract:RATIONALE AND OBJECTIVES:Ultrasound can cause destruction of microbubble contrast agents used to enhance medical ultrasound imaging. This study sought to characterize the dynamics of this interaction by direct visual observation of microbubbles during insonification in vitro by a medical ultrasound imaging system. MET...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199812000-00004

    authors: Klibanov AL,Ferrara KW,Hughes MS,Wible JH Jr,Wojdyla JK,Dayton PA,Morgan KE,Brandenburger GH

    更新日期:1998-12-01 00:00:00

  • Effect of Age on High T1 Signal Intensity of the Dentate Nucleus and Globus Pallidus in a Large Population Exposed to Gadodiamide.

    abstract:OBJECTIVE:The purpose of this study was to assess the effect of age and number of previous injections of gadodiamide on the signal intensity of unenhanced T1-weighted (T1w) images of the dentate nucleus and globus pallidus in a large population. MATERIALS AND METHODS:A large, single-center retrospective population sur...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000431

    authors: Quattrocchi CC,Errante Y,Mallio CA,Marinelli L,LoVullo G,Giannotti G,Della Sala SW,van der Molen AJ,Beomonte Zobel B

    更新日期:2018-04-01 00:00:00

  • Pulmonary microangiography. A comparison of in vitro versus in vivo perfusion techniques in dogs.

    abstract::Because of a need to correlate pulmonary microvascular changes with physiologic data during lung injury, in vitro and in vivo pulmonary capillary microangiography was performed on normal dogs and those subjected to oleic acid injury and glass bead microembolization. During these studies, no significant differences wer...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:

    authors: Clark RL,Friedman M,Kwock L,Zaremba J

    更新日期:1983-01-01 00:00:00

  • Contrast media tonicity. Part I. Effects upon IV-DSA time-concentration curve peak and width: experimental studies.

    abstract::Prior to the formation of an intravenous digital subtraction angiography (IV-DSA) image, contrast medium passes through the lesser circulation and is diluted by the blood volume of the heart and lungs. If the contrast medium alone influences central blood volume or cardiac output, the shape of the resultant time-conce...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198603000-00009

    authors: Burbank FH,Thompson WM

    更新日期:1986-03-01 00:00:00

  • Pathophysiology of radiocontrast nephropathy: a role for medullary hypoxia.

    abstract::Recent experimental data underlies the role of hypoxic tubular injury in the pathophysiology of radiocontrast nephropathy. Although systemic transient hypoxemia, increased blood viscosity, and a leftward shift of the oxygen-hemoglobin dissociation curve may all contribute to intrarenal hypoxia, imbalance between oxyge...

    journal_title:Investigative radiology

    pub_type: 杂志文章,评审

    doi:10.1097/00004424-199911000-00004

    authors: Heyman SN,Reichman J,Brezis M

    更新日期:1999-11-01 00:00:00

  • Combined methods for assessment of neurotoxicity: testing of new nonionic radiographic media.

    abstract::A battery of tests for toxicity assessment of new contrast media is reviewed. Cell toxicity in a protozoan culture (Blepharisma americanum); lethal dose determination in mice; EEG Spectral analysis following cisternography in rabbits; ED50 and LD50 determination by intra- and pericerebral injection in rats; intraciste...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198011001-00053

    authors: Sovak M,Siefert HM,Ranganathan R

    更新日期:1980-11-01 00:00:00

  • Spatial resolution analysis of computed tomographic images.

    abstract::Methods are presented for the quantification of spatial resolution in x-ray computed tomographic (CT) images. Model-dependent methods are derived and compared with model independent methods for computation of the Modulation Transfer Function (MTF). These techniques are applied to phantom images of point, line, edge, a...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198603000-00012

    authors: Assimakopoulos PA,Boyd DP,Jaschke W,Lipton MJ

    更新日期:1986-03-01 00:00:00

  • Retrievable patent ductus arteriosus plug for interventional, transvenous occlusion of the patent ductus arteriosus. Evaluation in lambs and preliminary clinical results.

    abstract:RATIONALE AND OBJECTIVES:The clinically most widely used devices (Porstmann-plug, Rashkind-umbrella, Botallooccluder) have inherent specific limitations (eg, transarterial approach, residual shunts, limited retrieval). The authors assess practicability, efficacy, and tissue reaction of the new retrievable transvenous p...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199709000-00004

    authors: Grabitz RG,Schräder R,Sigler M,Seghaye MC,Dzionsko C,Handt S,Schneidt B,Von Bernuth G

    更新日期:1997-09-01 00:00:00

  • Quantification of roughness of calcific deposits in computed tomography scans of human coronary arteries.

    abstract:OBJECTIVES:The incidence of coronary artery disease has been shown to be greater in patients with calcific deposits than in those without. It has been suggested that the pattern of distribution of coronary calcific deposits within coronary arteries is of greater predictive value for acute coronary events than the overa...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e3180cc2041

    authors: Wilner WT,Mazraeshahi RM,Aboshady I,Bodmann BG,Papadakis M,Kouri D,Conyers JL,Cherukuri P,Vela D,Gladish G,Gavish L,Cody DD,Frazier L,Lukovenkov S,Madjid M,Zarrabi A,Ahmed A,Willerson JT,Casscells SW,Gertz SD

    更新日期:2007-11-01 00:00:00

  • Relative carotid blood flow measurements in dogs by high-speed CT. A preliminary study.

    abstract::A high-speed computed tomography (CT) scanner was used for measuring flow in a phantom and in the common carotid arteries of six dogs. The general ability of the scanner to assess flow using contrast media boluses was tested with the phantom. The validated simple concept was then used in the animals. The carotid blood...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198712000-00008

    authors: Ringertz HG,Jaschke W,Sievers R,Lipton MJ

    更新日期:1987-12-01 00:00:00

  • Extravascular extravasation of radiographic contrast media. Effects of conventional and low-osmolar agents in the rat thigh.

    abstract::We compared the damage resulting from intradermal injection of four commonly used radiographic contrast media in laboratory rats. Sixty percent meglumine diatrizoate (Reno M 60) and ioxaglate (Hexabrix) produced significantly more ulceration and crusting on gross inspection and more necrosis, edema, and hemorrhage on ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199005000-00006

    authors: Cohan RH,Leder RA,Bolick D,Herzberg AJ,Hedlund LW,Wheeler CT,Helms MJ,Dunnick NR

    更新日期:1990-05-01 00:00:00

  • Ultrasonic detection of osteomyelitis. Pathologic correlation in an animal model.

    abstract::The authors correlated sonographic findings with histologic findings in a rabbit model of osteomyelitis. Staphylococcus aureus osteomyelitis was induced in the femora of 11 New Zealand white rabbits. The opposite leg was used as a control. Sonographic findings showed fluid adjacent to the bone in 11 cases. The fluid w...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199202000-00002

    authors: Abiri MM,DeAngelis GA,Kirpekar M,Abou AN,Ablow RC

    更新日期:1992-02-01 00:00:00

  • Biliary tract depiction in living potential liver donors at 3.0-T magnetic resonance cholangiography.

    abstract:OBJECTIVES:To prospectively evaluate accuracy of biliary anatomy depiction and quality of biliary tract visualization of magnetic resonance cholangiography (MRC) at 3.0 T in living potential liver donors (LPLDs). MATERIALS AND METHODS:Our institutional review board approved this study and did not require patient's inf...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e31817e9b52

    authors: Kim SY,Byun JH,Hong HS,Choi EK,Lee SS,Park SH,Lee MG

    更新日期:2008-08-01 00:00:00

  • Low tube voltage improves computed tomography imaging of delayed myocardial contrast enhancement in an experimental acute myocardial infarction model.

    abstract:OBJECTIVE:We sought to evaluate the influence of tube voltage on the visualization of acute myocardial infarction (MI) in cardiac multislice spiral computed tomography (MSCT). MATERIALS AND METHODS:Acute MI was induced in 12 domestic pigs by a 45-minute balloon occlusion of the left anterior descending artery. Delayed...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/01.rli.0000251577.68223.84

    authors: Mahnken AH,Bruners P,Mühlenbruch G,Emmerich M,Hohl C,Günther RW,Wildberger JE

    更新日期:2007-02-01 00:00:00

  • Short-term effects of a new intravascular nitinol stent in canine arteries.

    abstract:RATIONALE AND OBJECTIVES:To evaluate the short-term effects of a new nitinol stent on canine arteries. METHODS:Eighteen nitinol mesh stents were placed in abdominal aortas, common iliac arteries, and renal arteries of six dogs. Angiography was performed to evaluate the patency rates and structural changes of arteries ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199905000-00007

    authors: Lee KW,Park JH,Chung JW,Kim WS,Lee W,Yeon KM

    更新日期:1999-05-01 00:00:00

  • Noninvasive measurement of an index of renal blood flow.

    abstract::A new technique for the noninvasive measurement of an index of renal blood flow is described. The method utilizes ultrasound determined renal volume and radionuclide assessment of the mean transit time of a pertechnetate bolus through the kidneys. From this information a value for flow is calculated according to compa...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198307000-00009

    authors: Powers TA,Rees RS,Bowen RD

    更新日期:1983-07-01 00:00:00

  • The effect of computed tomographic scan orientation on information loss in the three-dimensional reconstruction of tripod zygomatic fractures.

    abstract::Fractures modeled in the dried skull indicate that the initial plane of computed tomography (CT) section contributes to the accuracy of three-dimensional (3D) images generated from two-dimensional (2D) CT data. The authors retrospectively analyzed seven clinical cases of tripod zygomatic fractures that were imaged wit...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199105000-00009

    authors: Levy RA,Kellman RM,Rosenbaum AE

    更新日期:1991-05-01 00:00:00

  • Cine phase-contrast magnetic resonance imaging for analysis of flow phenomena in experimental aortic dissection.

    abstract::Using a 1.5 T magnetic resonance imaging (MRI) system, cine phase-contrast and magnitude images were obtained in three phantoms that simulated different anatomic configurations of aortic dissection. The dissection phantoms were made of compliant materials, and pulsatile flow was used in all experiments. Phantoms diffe...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199112000-00007

    authors: Iwai F,Sostman HD,Evans AJ,Nadel SN,Hedlund LW,Beam CA,Charles HC,Spritzer CE

    更新日期:1991-12-01 00:00:00

  • Blood velocity calculated from volumetric dynamic computed tomography angiography.

    abstract:OBJECTIVE:Though functional intravascular parameters such as blood velocity and direction of blood flow are available via imaging modalities such as Doppler ultrasound and phase contrast magnetic resonance imaging, such quantitative information is not yet supported by computed tomography (CT). In this study, we examine...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e3181ea3588

    authors: Barfett JJ,Fierstra J,Mikulis DJ,Krings T

    更新日期:2010-12-01 00:00:00

  • Helium3 polarization using spin exchange technique: application to simultaneous pulmonary ventilation/perfusion imaging in small animals.

    abstract:RATIONALE AND OBJECTIVES:To develop a simple and robust helium3 polarization system dedicated to small animal imaging. To demonstrate the potential of helium3 imaging for pulmonary ventilation and perfusion studies. METHODS:A home-built polarization system based on spin-exchange technique was used. This system was app...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:

    authors: Stupar V,Berthezène Y,Canet E,Tournier H,Dupuich D,Crémillieux Y

    更新日期:2003-06-01 00:00:00

  • Gadobutrol-enhanced, three-dimensional, dynamic MR imaging with MR cholangiography for the preoperative evaluation of bile duct cancer.

    abstract:PURPOSE:To evaluate the diagnostic performance of 1.0-M gadobutrol-enhanced, 3-dimensional (3D), dynamic MR images with 3D-MR cholangiography (MRC) in the preoperative evaluation of bile duct cancer staging and resectability. MATERIALS AND METHODS:Our institutional review board approved this retrospective study. Sixty...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e3181d2eeb1

    authors: Ryoo I,Lee JM,Chung YE,Park HS,Kim SH,Han JK,Choi BI

    更新日期:2010-04-01 00:00:00

  • An experimental evaluation of central vs. peripheral injection for intravenous digital subtraction angiography (IV-DSA).

    abstract::At a given radiation dosage and field of view, five variables are under meaningful control for intravenous digital subtraction angiography (IV-DSA): concentration and quantity of contrast media injected, volume of injectate, rate of injection, and site of injection. Some controversy exists regarding the selection of a...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198401000-00007

    authors: Rubin DL,Burbank FH,Bradley BR,Brody WR

    更新日期:1984-01-01 00:00:00