Abstract:
OBJECTIVES:To evaluate the potential of quantitative assays of vascular characteristics based on dynamic contrast-enhanced magnetic resonance imaging (MRI) using a macromolecular contrast medium (MMCM) to search for and measure effects of dimethyl sulfoxide (DMSO) on cancer vasculature with microscopic correlations. MATERIAL AND METHODS:Saline-treated control (n = 8) and DMSO-treated (n = 7) human breast cancer xenografts (MDA-MB-435) in rats were imaged dynamically by MMCM-enhanced MRI using albumin-(Gd-DTPA)27-(biotin)11 (molecular weight approximately 90 kDa), before and after a 1-week, 3-dose treatment course. After the posttreatment MRI examinations, tumors were perfused with lectin and fixative and subsequently stained with RECA-1 and streptavidin for quantitative fluorescent microscopy. Quantitative MRI estimates of cancer microvessel permeability (KPS; microL/min.100 cm3) and fractional plasma volume (fPV; %) were based on a 2-compartment kinetic model. Fluorescent microscopy yielded estimates of MMCM extravasation and vascular density that were compared to the MRI results. RESULTS:DMSO decreased cancer vascular endothelial permeability significantly (P < 0.05) from tumor KPSday0 = 19.3 +/- 8.8 microL/min.100 cm3 to KPSday7 = 0 microL/min.100 cm3). K values in the saline-treated tumors did not change significantly. The amount of extravasated albumin-Gd-(DTPA)27-(biotin)11, as assayed by a fluorescently labeled streptavidin stain that strongly binds to the biotin tag on the MMCM, was significantly (P < 0.05) lower in the DMSO-treated cancers than in the control cancers (57.7% +/- 5.5% vs. 34.2% +/- 4.9%). Tumor vascular richness as reflected by the MRI-assayed fPV and by the RECA-1 and lectin-stained microscopy did not change significantly with DMSO or saline treatment. CONCLUSION:Reductions in cancer microvascular leakiness induced by a 7-day course of DMSO could be detected and measured by dynamic MMCM-enhanced MRI and were confirmed by microscopic measurements of the leaked macromolecular agents in the same cancers. Results support the robustness of an MMCM-enhanced MRI approach to the characterization of cancers and providing first evidence for an in vivo effect of DMSO on cancer blood vessels.
journal_name
Invest Radioljournal_title
Investigative radiologyauthors
Cyran CC,Sennino B,Chaopathomkul B,Fu Y,Rogut V,Shames DM,Wendland MF,McDonald DM,Brasch RCdoi
10.1097/RLI.0b013e318164b71dsubject
Has Abstractpub_date
2008-05-01 00:00:00pages
298-305issue
5eissn
0020-9996issn
1536-0210pii
00004424-200805000-00004journal_volume
43pub_type
杂志文章abstract:RATIONALE AND OBJECTIVES:Dynamic contrast enhanced (DCE) MR mammography (MRM) uses tumor capillary density differences for prognosis. The heterogeneous response of permeability-surface area products (PS = Kp<-->t) was examined in mammary tumors, as a function of contrast agent size, to determine what effect ROI size mi...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-200204000-00003
更新日期:2002-04-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:The authors studied the effect of contrast dose, use of magnetization transfer (MT), and temporal delay on the visualization of contrast enhancement with gadoteridol (Gd HP-DO3A) in a canine brain abscess model. METHODS:Alpha streptococcus brain abscesses were studied in five dogs at 1.5 tesla...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199503000-00001
更新日期:1995-03-01 00:00:00
abstract:OBJECTIVES:The objective of this study was to assess the feasibility of the combination of magnetic resonance (MR)-guided biopsy (MRGB) and diagnostic 3T MR imaging in the localization of local recurrence of prostate cancer (PCa) after external beam radiation therapy (EBRT). MATERIALS AND METHODS:Twenty-four consecuti...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0b013e3181c7bcda
更新日期:2010-03-01 00:00:00
abstract:PURPOSE:The aim of this study was to evaluate the feasibility of a prototype volume-interpolated breath-hold examination (VIBE) sequence using compressed sensing (VIBECS) for rapid multiphase arterial magnetic resonance imaging (MRI) at different temporal resolution during free-breathing in comparison with a convention...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0000000000000459
更新日期:2018-10-01 00:00:00
abstract::The authors investigated the effect on the brain of red blood cells that had been modified by contrast media. Rat blood was mixed with an equivolume of contrast media, and up to 200 microL of the mixture was infused to the internal carotid artery of the rat. Evans blue was administered intravenously to assess the inte...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198905000-00009
更新日期:1989-05-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:The authors studied the incidence and distribution of orthopedic injuries sustained in Operation Desert Shield and Desert Storm by evaluating whether existing diagnostic imaging modalities were sufficient to diagnose the types of musculoskeletal injuries incurred. The authors also sought to det...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199703000-00006
更新日期:1997-03-01 00:00:00
abstract::The authors compared the renal toxicity of the low osmolality radiocontrast agents, iohexol and ioxaglate, and the ionic agent, iothalamate, at equivalent iodine dose, using experimental models in vitro and in vivo. In isolated perfused rat kidneys, all agents induced comparable biphasic hemodynamic changes, associate...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199104000-00008
更新日期:1991-04-01 00:00:00
abstract:OBJECTIVES:The objectives of this study were to assess the feasibility of magnetic resonance cholangiography (MRC) using biliary-secreted gadoxetic acid at 7 T and to compare it with T2-weighted (w) MRC at 3 T. MATERIALS AND METHODS:Ten healthy volunteers were examined on a 7-T whole-body magnetic resonance system. T2...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0000000000000004
更新日期:2014-05-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:The author analyzes findings of consistency of rotator-cuff calcifications found at ultrasound (US)-guided needle treatment compared with findings of plain radiography, US, and computed tomography (CT). METHODS:Twenty patients had rotator-cuff calcifications (mean diameter, 1.5 cm; range, 1.1-...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199605000-00010
更新日期:1996-05-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:To compare gadobenate dimeglumine (Gd-BOPTA) with gadopentetate dimeglumine (Gd-DTPA) for magnetic resonance imaging of the liver. METHODS:The contrast agent Gd-BOPTA or Gd-DTPA was administered at a dose of 0.1 mmol/kg to 257 patients suspected of having malignant liver tumors. Dynamic phase ...
journal_title:Investigative radiology
pub_type: 临床试验,杂志文章,随机对照试验
doi:10.1097/00004424-200111000-00002
更新日期:2001-11-01 00:00:00
abstract::A 144cerium-induced osteosarcoma was transplanted to athymic nude rats (Han:rnu/rnu). Nineteen of the tumor-bearing animals were used to demonstrate the characteristics of the osteosarcoma on magnetic resonance imaging (MRI) in comparison with a group of nine animals that had not received any tumor transplant. The tum...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:
更新日期:1992-03-01 00:00:00
abstract:OBJECTIVES:Multidetector-row computed tomography coronary images are usually analyzed in mid-diastole (MD). Because of slow coronary motion also in end-systole (ES), we evaluated the impact on image quality of including ES images and defined an efficient reconstruction protocol. MATERIAL AND METHODS:In 50 coronary mul...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/01.rli.0000153930.34439.e4
更新日期:2005-03-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:Echogenic antibody-conjugated anionic liposomes have been developed that allow directed tissue targeting and acoustic enhancement. These are not efficient for gene delivery. A cationic formulation that allows directed gene delivery while retaining acoustic properties may provide more efficient ...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-200012000-00007
更新日期:2000-12-01 00:00:00
abstract:OBJECTIVES:The aim of this study was to assess the effectiveness of a model-based iterative reconstruction (MBIR) in improving image quality and diagnostic performance of ultralow-dose computed tomography (ULDCT) of the lung. MATERIALS AND METHODS:The institutional review board approved this study, and all patients pr...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0b013e3182562a89
更新日期:2012-08-01 00:00:00
abstract::A nonionic contrast medium (iohexol) was evaluated for safety and efficacy in pediatric angiocardiography in this study of 15 patients, age 6 to 82 months. Patients carried a preliminary diagnosis of congenital heart disease. Subjects were injected with iohexol, 350 mg iodine/ml of solution with an average volume of 2...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:
更新日期:1985-01-01 00:00:00
abstract::Ionic (diatrizoate, ioxaglate) and nonionic (iohexol, iosimide, iopromide, and iotrolan) contrast media (CM) were evaluated for their cytogenetic effects in lymphocytes. Heparinized blood was mixed with culture medium RPMI-1640 supplemented with phytohemagglutinin, fetal calf serum, and antibiotics. Plastic tubes cont...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198611000-00006
更新日期:1986-11-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:To improve the accuracy of magnetic resonance imaging (MRI) in evaluating the response of osteosarcomas to preoperative chemotherapy, the authors developed a technique of mapping tumor necrosis and viability by quantitating slope values of gadolinium-DTPA (Gd-DTPA) uptake on dynamic fast low-an...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199205000-00010
更新日期:1992-05-01 00:00:00
abstract:OBJECTIVES:The purposes of this study were to evaluate the reference range of quantitative computed tomography (QCT) measures of lung attenuation and airway parameter measurements in healthy nonsmoking adults and to identify sources of variation in those measures and possible means to adjust for them. MATERIALS AND ME...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0b013e318262292e
更新日期:2012-10-01 00:00:00
abstract::A method is presented by whichcomputed tomography scans carried out at a number of energies may be utilized to obtain cross-sectional images of density and atomic number in addition to the conventional array of linear attenuation coefficients. This type of analysis has been carried out for various substances of biolog...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-197703000-00016
更新日期:1977-03-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:We investigated whether it is possible to investigate degenerative changes in human tissue on a sub-100-microm resolution scale not only on special high-field small-bore MR-microscopy systems but also on a 3T whole-body MR-scanner. METHODS:Spin-spin relaxation, proton density, and diffusion mi...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/01.RLI.0000068620.17569.83
更新日期:2003-07-01 00:00:00
abstract:OBJECTIVE:The objective of this study was to determine the gadolinium (Gd) concentration remaining in human bone tissue after administration of standard clinical doses of 2 Gd-based contrast agents: ProHance and Omniscan. MATERIALS AND METHODS:After administration of 0.1 mmol/kg of Gd chelate to patients undergoing hi...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/01.rli.0000186569.32408.95
更新日期:2006-03-01 00:00:00
abstract::A considerable amount of concern has been felt recently for the risk of carcinogenesis from x-rays to scoliosis patients. This paper re-evaluates risk in quantitative terms by using some data measured by us and other data recently published in the literature. The risks are considerably smaller than had been estimated ...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198401000-00014
更新日期:1984-01-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:To assess the influence of injection rates and volumes on the arrival time of contrast material (CM) in the common carotid artery, the jugular vein and the resulting arterial-venous transit time. Additionally the relationship between injection parameters and the extent of a CM plateau was evalu...
journal_title:Investigative radiology
pub_type: 临床试验,杂志文章,随机对照试验
doi:10.1097/01.rli.0000105040.40925.c8
更新日期:2004-02-01 00:00:00
abstract:OBJECTIVE:Commercially available iodinated contrast media (CM) show significantly different physico-chemical properties. The relevance of the viscosity of CM may be underestimated as a contributing factor for clinically relevant renal failure as suggested by a large registry data analysis (Swedish registry study). The ...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0b013e318190fbd2
更新日期:2009-02-01 00:00:00
abstract:PURPOSE:The aim of this study was to evaluate the diagnostic performance of virtual noncalcium (VNCa) dual-energy computed tomography (DECT) reconstructions enabling visualization of bone marrow edema for characterization of incidental thoracolumbar compression fractures in routine thoracoabdominal staging computed tom...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0000000000000458
更新日期:2018-07-01 00:00:00
abstract:OBJECTIVES:The aim of this study was to assess the impact of oral water and intravenous furosemide challenges on blood oxygenation level-dependent magnetic resonance imaging measurements in the kidney and to examine the contribution of R2 (=1/T2) to changes in R2* (=1/T2*). MATERIALS AND METHODS:This Health Insurance ...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0b013e3182823591
更新日期:2013-07-01 00:00:00
abstract:OBJECTIVES:The aims of this study were to investigate and validate quantitative susceptibility mapping (QSM) for lesional iron quantification in cerebral cavernous malformations (CCMs). MATERIALS AND METHODS:Magnetic resonance imaging studies were performed in phantoms and 16 patients on a 3-T scanner. Susceptibility ...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0000000000000043
更新日期:2014-07-01 00:00:00
abstract::Altered concentrations of brain beta endorphin and spinal cord encephalin have been reported in mice with iatrogenic arachnoiditis. We measured beta-endorphin concentration in cerebrospinal fluid (CSF) in normal monkeys and in monkeys with various degrees of arachnoiditis resulting from myelography and spinal surgery ...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198803000-00006
更新日期:1988-03-01 00:00:00
abstract::Human gallstones were surgically placed into the gallbladders of 200 swine. Eight of these swine were used as a prospective series to verify that the placement and presence of human gallstones in their gallbladders caused no significant pathologic changes in the gallbladder and that the gallstones were not spontaneous...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198902000-00005
更新日期:1989-02-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:This study was conducted to determine whether significant reduction in radiation dose (250 mAs-->50 mAs), in chest computed tomography (CT) using volume acquisition affects image quality or the detectability of pathologic findings in the lung and mediastinum. METHODS:Phantom studies were condu...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199802000-00002
更新日期:1998-02-01 00:00:00