Retention of iodine and expression of biomarkers for renal damage in the kidney after application of iodinated contrast media in rats.

Abstract:

OBJECTIVE:Commercially available iodinated contrast media (CM) show significantly different physico-chemical properties. The relevance of the viscosity of CM may be underestimated as a contributing factor for clinically relevant renal failure as suggested by a large registry data analysis (Swedish registry study). The objective of this preclinical study is to assess differences of a low and high-viscous CM regarding their retention time in the kidney. Furthermore, we investigated the expression of marker genes for renal damage and hypoxia to evaluate a potential renal damage and hypoxia after application of iodinated CM. MATERIAL AND METHODS:After application of Iopromide 300 and Iodixanol 320 CM, the iodine concentration over time was determined using computed tomography and x-ray fluorescence analysis in healthy Han Wistar and renally impaired ZSF1 rats. The latter served as a model for age and diabetes-related renal impairment. X-ray attenuation (Hounsfield units) in the renal cortex was analyzed by 2 independent blinded readers. Furthermore, the expression of kidney injury molecule 1 (Kim-1/Havcr1) and heme oxygenase I (HO-1/HMOX1) was measured by quantitative reverse transcription-polymerase chain-reaction. RESULTS:Computed tomography and x-ray fluorescence analysis in the kidneys of animals treated with Iodixanol revealed significantly prolonged retention of iodine in the kidney as compared with animals treated with Iopromide. This difference was even more pronounced in renally impaired rats. Twenty-four hours after Iodixanol treatment, significantly increased levels of Kim-1/Havcr1 and HO-1/HMOX1 transcript levels were observed compared with the saline and Iopromide treatment. CONCLUSIONS:A prolonged retention of contrast media in the kidney was observed after administration of dimeric CM (Iodixanol 320). One possible explanation for this effect could be the high viscosity of the dimeric CM (Iodixanol 320) and the lack of dilution by osmotic diuresis. This prolonged exposure is possibly associated with higher renal toxicity as indicated by the elevated expression of biomarkers for hypoxia and renal injury.

journal_name

Invest Radiol

journal_title

Investigative radiology

authors

Jost G,Pietsch H,Sommer J,Sandner P,Lengsfeld P,Seidensticker P,Lehr S,Hütter J,Sieber MA

doi

10.1097/RLI.0b013e318190fbd2

subject

Has Abstract

pub_date

2009-02-01 00:00:00

pages

114-23

issue

2

eissn

0020-9996

issn

1536-0210

journal_volume

44

pub_type

杂志文章
  • Comprehensive assessment of renal function and vessel morphology in potential living kidney donors: an MRI-based approach.

    abstract:OBJECTIVES:To test the feasibility of a single MR-based examination allowing for the comprehensive assessment of renal anatomy, function, and vascular status in candidates for kidney transplantation. MATERIALS AND METHODS:Twelve healthy potential kidney donors (mean age: 47 +/- 14 [standard deviation] years, 3 men and...

    journal_title:Investigative radiology

    pub_type: 临床试验,杂志文章

    doi:10.1097/RLI.0b013e3181b35a70

    authors: Rossi C,Boss A,Artunc F,Yildiz S,Martirosian P,Dittmann H,Claussen CD,Heyne N,Schick F,Schlemmer HP

    更新日期:2009-11-01 00:00:00

  • Dechelation (Transmetalation): Consequences and Safety Concerns With the Linear Gadolinium-Based Contrast Agents, In View of Recent Health Care Rulings by the EMA (Europe), FDA (United States), and PMDA (Japan).

    abstract::The issue of dechelation (transmetallation) in vivo after administration of the linear gadolinium-based contrast agents, and potential safety concerns, is considered on the basis of an extensive, focused literature review. Early indications of potential problems included the high level of excess ligand used in the for...

    journal_title:Investigative radiology

    pub_type: 杂志文章,评审

    doi:10.1097/RLI.0000000000000507

    authors: Runge VM

    更新日期:2018-10-01 00:00:00

  • Assessment of osteosarcoma response to preoperative chemotherapy using dynamic FLASH gadolinium-DTPA-enhanced magnetic resonance mapping.

    abstract:RATIONALE AND OBJECTIVES:To improve the accuracy of magnetic resonance imaging (MRI) in evaluating the response of osteosarcomas to preoperative chemotherapy, the authors developed a technique of mapping tumor necrosis and viability by quantitating slope values of gadolinium-DTPA (Gd-DTPA) uptake on dynamic fast low-an...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199205000-00010

    authors: Hanna SL,Parham DM,Fairclough DL,Meyer WH,Le AH,Fletcher BD

    更新日期:1992-05-01 00:00:00

  • Computed tomography-pathologic assessment of laser-induced necrosis in rat liver.

    abstract:RATIONALE AND OBJECTIVES:Interstitial laser photocoagulation (ILP) causes localized tissue necrosis. This study was performed to determine 1) whether the changes seen on computed tomography (CT) correspond to the necrosis pathologically, and 2) which CT technique best shows the necrosis. METHODS:Eighteen Wistar rats h...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199312000-00014

    authors: Amin Z,Thurrell W,Spencer GM,Harries SA,Grant WE,Bown SG,Lees WR

    更新日期:1993-12-01 00:00:00

  • Solid, part-solid, or non-solid?: classification of pulmonary nodules in low-dose chest computed tomography by a computer-aided diagnosis system.

    abstract:OBJECTIVES:The purpose of this study was to develop and validate a computer-aided diagnosis (CAD) tool for automatic classification of pulmonary nodules seen on low-dose computed tomography into solid, part-solid, and non-solid. MATERIALS AND METHODS:Study lesions were randomly selected from 2 sites participating in t...

    journal_title:Investigative radiology

    pub_type: 临床试验,杂志文章,多中心研究,随机对照试验

    doi:10.1097/RLI.0000000000000121

    authors: Jacobs C,van Rikxoort EM,Scholten ET,de Jong PA,Prokop M,Schaefer-Prokop C,van Ginneken B

    更新日期:2015-03-01 00:00:00

  • Effect of intraarticular pressure on patellar position. Computed tomography study in cadaveric specimens.

    abstract:RATIONALE AND OBJECTIVES:The purpose of the study was to evaluate the effect of articular fluid distention on patellar position at different degrees of knee angulation. METHODS:Patellar position in 10 cadaveric knee specimens was determined with 30, 100, and 200 mm Hg joint distention at 45, 20, and 5 degrees of knee ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199602000-00001

    authors: Brossmann J,Koch S,Schwarzenberg H,Link J,Muhle C,Bull CC,Heller M

    更新日期:1996-02-01 00:00:00

  • BR1: a new ultrasonographic contrast agent based on sulfur hexafluoride-filled microbubbles.

    abstract:RATIONALE AND OBJECTIVES:The basic characteristics of BR1, a novel echo contrast agent based on stabilized sulfur hexafluoride (SF6) microbubbles have been evaluated. METHODS:The authors determined the physicochemical properties (bubble concentration, bubble size distribution, resistance to pressure, and stability) an...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199508000-00001

    authors: Schneider M,Arditi M,Barrau MB,Brochot J,Broillet A,Ventrone R,Yan F

    更新日期:1995-08-01 00:00:00

  • Contrast-enhanced magnetic resonance angiography in rabbits: evaluation of the gadolinium-based agent p846 and the iron-based blood pool agent p904 in comparison with gadoterate meglumine.

    abstract:OBJECTIVES:: To evaluate the performance of a gadolinium-based contrast compound (P846) as well as an ultra-small particle of iron oxide agent (P904) in contrast-enhanced magnetic resonance angiography (MRA) in rabbits and to compare those agents with gadoterate meglumine (Gd-DOTA) for first pass and steady state imagi...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e31821ae21f

    authors: Kinner S,Maderwald S,Parohl N,Albert J,Corot C,Robert P,Barkhausen J,Vogt FM

    更新日期:2011-08-01 00:00:00

  • Development, chemistry, and physical properties of iopamidol and its analogues.

    abstract::A series of 5-hydroxyacylamino-2,4,6-triiodo-N,N'-hydroxy-alkyl-isophtalamides was prepared in order to study the structural requirements for high water solubility and low toxicity. Among the amides substituted by 2-hydroxyethyl; 2,3-dihydroxypropyl; 1,3-dihydroxypropyl-; and 1,1-dihydroxy-methyl-2-oxyethyl- groups, t...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198011001-00065

    authors: Pitrè D,Felder E

    更新日期:1980-11-01 00:00:00

  • Increased ablation zones using a cryo-based internally cooled bipolar RF applicator in ex vivo bovine liver.

    abstract:PURPOSE:To evaluate the feasibility of ex vivo ablation implementing a cryo-based internally cooled bipolar radiofrequency (RF) applicator and to determine the influence of power and gas pressure on the size and shape of the resulting ablation zones. MATERIALS AND METHODS:Two hundred twenty-five ablations were perform...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e3181b66d11

    authors: Rempp H,Voigtländer M,Clasen S,Kempf S,Neugebauer A,Schraml C,Schmidt D,Claussen CD,Enderle MD,Goldberg SN,Pereira PL

    更新日期:2009-12-01 00:00:00

  • Comparative transmetallation kinetics and thermodynamic stability of gadolinium-DTPA bis-glucosamide and other magnetic resonance imaging contrast media.

    abstract:RATIONALE AND OBJECTIVES:The relative stability and selectivity of magnetic resonance (MR) imaging contrast agents were compared with in vitro transmetallation and ligand competition reactions. MATERIALS AND METHODS:A gadolinium (Gd)-DTPA-BIGA, Gd-DTPA-BMA, Gd-DTPA, or Gd-HP-DO3A solution was mixed with an equimolar s...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199610000-00003

    authors: Puttagunta NR,Gibby WA,Puttagunta VL

    更新日期:1996-10-01 00:00:00

  • Mechanical and biochemical cardiac disturbances induced by bolus administration of iodinated contrast media and noniodinated solutions.

    abstract:RATIONALE AND OBJECTIVES:Bolus injection of iodinated contrast media has been observed to alter myocardial mechanical function, but the consequences on cellular metabolism are poorly documented. Modifications of metabolic parameters (intracellular pH as well as adenosine triphosphate [ATP], phosphocreatine, and inorgan...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199501000-00001

    authors: Goossens A,Vander Elst L,Van Haverbeke Y,Muller RN

    更新日期:1995-01-01 00:00:00

  • The influence of contrast medium dose on filtration fraction in the rabbit kidney.

    abstract::We have examined the effect of dose on contrast medium-induced reductions in glomerular filtration in anesthetized rabbits. The fraction of renal plasma flow that is filtered, the filtration fraction, was directly measured by the renal arteriovenous difference method using technetium-99m (99mTc) (Sn) DTPA as the trace...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198309000-00007

    authors: Harvey LA,Caldicott WJ

    更新日期:1983-09-01 00:00:00

  • Clinical and High-Resolution CT Features of the COVID-19 Infection: Comparison of the Initial and Follow-up Changes.

    abstract:OBJECTIVES:In late December 2019, an outbreak of coronavirus disease (COVID-19) in Wuhan, China was caused by a novel coronavirus, newly named severe acute respiratory syndrome coronavirus 2. We aimed to quantify the severity of COVID-19 infection on high-resolution chest computed tomography (CT) and to determine its r...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000674

    authors: Xiong Y,Sun D,Liu Y,Fan Y,Zhao L,Li X,Zhu W

    更新日期:2020-06-01 00:00:00

  • A method for evaluating the bronchial circulation. Preliminary observations.

    abstract::Due to the small size of the bronchial arteries, the bronchial circulation is difficult to study and remains poorly understood. We have utilized single photon emission computed tomography (SPECT) as a noninvasive means of studying the bronchial circulation. Imaging studies were performed in sheep before and after the ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199001000-00014

    authors: Chiles C,Newman GE,Blinder RA

    更新日期:1990-01-01 00:00:00

  • Accuracy of ultrasound in fetal femur length determination. Ultrasound phantom study.

    abstract::An ultrasound phantom was constructed simulating fetal femurs in amniotic fluid. Bones of 26, 36, 50, 58, and 70 mm, representative of gestational ages ranging from 17 to 36 weeks, were scanned with mechanical sector, phased sector, and linear array systems (ATL, Diasonics, Acuson, and GE). Measurements were made with...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198505000-00016

    authors: Gamba JL,Bowie JD,Dodson WC,Hedlund LW

    更新日期:1985-05-01 00:00:00

  • Temporal changes in the oxidation state in in vitro blood.

    abstract::The rates at which the paramagnetic compounds deoxyhemoglobin (Hb) and methemoglobin (MHb) form in vivo within an area of hemorrhage are unknown. The present experiment establishes the baseline concentrations and rates of change in paramagnetic hemoglobin concentrations, as well as the pH in normal heparinized and clo...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199003000-00006

    authors: Taber KH,Migliore PJ,Pagani JJ,Ford JJ,McLauren T,Hayman LA

    更新日期:1990-03-01 00:00:00

  • Phase I clinical evaluation of citrate-coated monocrystalline very small superparamagnetic iron oxide particles as a new contrast medium for magnetic resonance imaging.

    abstract:RATIONALE AND OBJECTIVES:To evaluate the safety and pharmacokinetics of a newly developed MR contrast medium consisting of very small superparamagnetic iron oxide particles (VSOP) coated with citrate (VSOP-C184) in a clinical phase I trial. METHODS:A total of 18 healthy subjects received either VSOP-C184 (core diamete...

    journal_title:Investigative radiology

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1097/01.rli.0000129472.45832.b0

    authors: Taupitz M,Wagner S,Schnorr J,Kravec I,Pilgrimm H,Bergmann-Fritsch H,Hamm B

    更新日期:2004-07-01 00:00:00

  • Lung perfusion demonstrated by contrast-enhanced dynamic magnetic resonance imaging. Application to unilateral lung transplantation.

    abstract:RATIONALE AND OBJECTIVES:The authors evaluate the use of magnetic resonance (MR) to image pulmonary perfusion in healthy controls and to detect pulmonary defects in patients with unilateral lung transplantation, using dynamic images after contrast administration. METHODS:Five patients with right lung transplantation a...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199706000-00006

    authors: Berthezène Y,Croisille P,Bertocchi M,Houzard C,Bendib K,Revel D

    更新日期:1997-06-01 00:00:00

  • Segmentation-based attenuation correction in positron emission tomography/magnetic resonance: erroneous tissue identification and its impact on positron emission tomography interpretation.

    abstract:OBJECTIVES:The objective of this study was to evaluate the frequency and characteristics of artifacts in segmentation-based attenuation correction maps (μ-maps) of positron emission tomography/magnetic resonance (PET/MR) and their impact on PET interpretation and the standardized uptake value (SUV) quantification in no...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000131

    authors: Brendle C,Schmidt H,Oergel A,Bezrukov I,Mueller M,Schraml C,Pfannenberg C,la Fougère C,Nikolaou K,Schwenzer N

    更新日期:2015-05-01 00:00:00

  • Digital radiography versus conventional radiography for the detection of a skull fracture under varying exposure parameters.

    abstract:RATIONALE AND OBJECTIVES:The effect of varying exposure parameters on the detectability of a fracture with digital and conventional radiography were examined. METHODS:A macerated fractured skull was imaged by film-screen radiography (FSR) and digital storage phosphor radiography (DR) with various exposure values. Five...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199303000-00010

    authors: Langen HJ,Klein HM,Wein B,Schiwy-Bochat KH,Stargardt A,Günther RW

    更新日期:1993-03-01 00:00:00

  • Ultrahigh-field imaging of the biliary tract at 7 T: initial results of gadoxetic acid-enhanced magnetic resonance cholangiography.

    abstract:OBJECTIVES:The objectives of this study were to assess the feasibility of magnetic resonance cholangiography (MRC) using biliary-secreted gadoxetic acid at 7 T and to compare it with T2-weighted (w) MRC at 3 T. MATERIALS AND METHODS:Ten healthy volunteers were examined on a 7-T whole-body magnetic resonance system. T2...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000004

    authors: Fischer A,Kraff O,Orzada S,Nensa F,Schäfer LC,Ladd ME,Umutlu L,Lauenstein TC

    更新日期:2014-05-01 00:00:00

  • Perfusion quantitation by ultrafast computed tomography.

    abstract::Flow measurements can be made with computed tomography (CT) scanners using iodinated, nonionic contrast media as a first-pass indicator. Ultrafast CT (UFCT) is an ideal machine to make these measurements because of its short scan time (50 mseconds) and interscan delay (< or = 0.6 seconds). Additionally, UFCT can acqui...

    journal_title:Investigative radiology

    pub_type: 杂志文章,评审

    doi:10.1097/00004424-199212002-00004

    authors: Gould RG

    更新日期:1992-12-01 00:00:00

  • Tubal sterilization by selective catheterization in an animal model.

    abstract:RATIONAL AND OBJECTIVES:The feasibility of tubal occlusion by selective salpingography was tested in an animal model; three novel occluding materials also were tested for this application. METHODS:Unilateral selective salpingography was performed in three groups of six rabbits; fallopian tubes were embolized with etha...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199402000-00007

    authors: Maubon A,Rouanet JP,Laurent A,Joujoux JM,Cover S,Courtieu C,Wassef M,Godlewski G,Honiger J,Lopez FM

    更新日期:1994-02-01 00:00:00

  • 3.0 Tesla high spatial resolution contrast-enhanced magnetic resonance angiography (CE-MRA) of the pulmonary circulation: initial experience with a 32-channel phased array coil using a high relaxivity contrast agent.

    abstract:PURPOSE:To evaluate the technical feasibility of high spatial resolution contrast-enhanced magnetic resonance angiography (CE-MRA) with highly accelerated parallel acquisition at 3.0 T using a 32-channel phased array coil, and a high relaxivity contrast agent. MATERIALS AND METHODS:Ten adult healthy volunteers (5 men,...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/01.rli.0000261937.77365.6a

    authors: Nael K,Fenchel M,Krishnam M,Finn JP,Laub G,Ruehm SG

    更新日期:2007-06-01 00:00:00

  • Interference of gadolinium-containing contrast-enhancing agents with colorimetric calcium laboratory testing.

    abstract:OBJECTIVES:The purpose of this study was to evaluate the extent to which various commercially available gadolinium-containing contrast-enhancing (CE) agents can interfere with the measurement of calcium levels by currently used laboratory methods, suggesting (spurious) hypocalcemia or hypercalcemia with a potential ris...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/01.rli.0000170447.45577.5e

    authors: Löwe A,Balzer T,Hirt U

    更新日期:2005-08-01 00:00:00

  • A preliminary study of MRI quantification of simulated calcified pulmonary nodules.

    abstract::The potential of magnetic resonance imaging (MRI) quantification of calcium for the evaluation of pulmonary nodules was investigated in simulated nodules. Calcium salts do not contain mobile protons and thus have no signal on MR proton images. To determine whether the absence of signal from partially calcified nodules...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198711000-00001

    authors: Gamsu G,de Geer G,Cann C,Müller N,Brito A

    更新日期:1987-11-01 00:00:00

  • Safety and efficacy of dotarem (Gd-DOTA) versus magnevist (Gd-DTPA) in magnetic resonance imaging of the central nervous system.

    abstract:RATIONALE AND OBJECTIVES:Gd-DTPA is a well-characterized, safe contrast agent frequently used in magnetic resonance imaging (MRI) of the central nervous system. The purpose of this double-blind, comparative MRI study of brain, spine, trunk, and limbs was to evaluate the safety and efficacy of Gd-DOTA versus Gd-DTPA in ...

    journal_title:Investigative radiology

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1097/00004424-199502000-00002

    authors: Oudkerk M,Sijens PE,Van Beek EJ,Kuijpers TJ

    更新日期:1995-02-01 00:00:00

  • Ultrasound bone velocity on proximal phalanges in premenopausal, perimenopausal, and postmenopausal healthy women.

    abstract:RATIONALE AND OBJECTIVES:The authors studied premenopausal, perimenopausal, and postmenopausal women to determine if ultrasound bone velocity (UBV) on proximal phalanges of women reflect bone changes related to gonadal status and age. METHODS:A total of 166 healthy women-64 postmenopausal women (mean age 58.7 +/- 9.4 ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199701000-00011

    authors: Aguado F,Revilla M,Hernández ER,Villa LF,Rico H

    更新日期:1997-01-01 00:00:00

  • Pyelovenous and pyelolymphatic backflow during retrograde pyelography in renal vein thrombosis.

    abstract::Pyelovenous and pyelolymphatic backflow have been observed during retrograde pyelography in three patients with renal vein thrombosis. The radiographic patterns of backflow following experimental unilateral renal vein occlusion in rabbits were analyzed and correlated with the clinical findings. Capsular, perihilar, pe...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198101000-00003

    authors: Bidgood WD Jr,Cuttino JT Jr,Clark RL,Volberg FM

    更新日期:1981-01-01 00:00:00