Renal blood oxygenation level-dependent imaging: contribution of R2 to R2* values.

Abstract:

OBJECTIVES:The aim of this study was to assess the impact of oral water and intravenous furosemide challenges on blood oxygenation level-dependent magnetic resonance imaging measurements in the kidney and to examine the contribution of R2 (=1/T2) to changes in R2* (=1/T2*). MATERIALS AND METHODS:This Health Insurance Portability and Accountability Act-compliant study had institutional review board approval, and written informed consent was obtained from all subjects. Nine healthy volunteers were imaged at 3 T on 2 visits. During each visit, a baseline fasting magnetic resonance acquisition was followed by a diuretic challenge: oral water load for the first visit and furosemide for the second. R2* and R2 values in the renal cortex and medulla were measured using multiple gradient echo and multiple spin echo sequences, respectively, and R2' values were computed as R2' = R2* - R2. Timed urinary output was also measured. RESULTS:Averaged across all subjects, the R2* response to furosemide was greater than to water and greater in the medulla than the cortex. The mean R2 responses exhibited the same trends but were uniformly smaller than the mean R2* responses. The peak changes in R2* and R2 appeared, on average, 10 to 14 minutes before peak urinary output. The median percentage contribution of R2 to R2* changes was 16% in the medulla after both challenges. In the cortex, the median contribution was 48% after water load and 58% after furosemide challenge. CONCLUSIONS:The contributions of R2 to R2* changes after water load and furosemide challenge are not negligible, especially in the renal cortex. In routine clinical practice, R2* could be used alone as a rough surrogate for R2' in the medulla. However, in the cortex, both R2 and R2* should be measured to obtain accurate values of R2'.

journal_name

Invest Radiol

journal_title

Investigative radiology

authors

Vivier PH,Storey P,Chandarana H,Yamamoto A,Tantillo K,Khan U,Zhang JL,Sigmund EE,Rusinek H,Babb JS,Bubenheim M,Lee VS

doi

10.1097/RLI.0b013e3182823591

subject

Has Abstract

pub_date

2013-07-01 00:00:00

pages

501-8

issue

7

eissn

0020-9996

issn

1536-0210

journal_volume

48

pub_type

杂志文章
  • Evaluation of iron content in human cerebral cavernous malformation using quantitative susceptibility mapping.

    abstract:OBJECTIVES:The aims of this study were to investigate and validate quantitative susceptibility mapping (QSM) for lesional iron quantification in cerebral cavernous malformations (CCMs). MATERIALS AND METHODS:Magnetic resonance imaging studies were performed in phantoms and 16 patients on a 3-T scanner. Susceptibility ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000043

    authors: Tan H,Liu T,Wu Y,Thacker J,Shenkar R,Mikati AG,Shi C,Dykstra C,Wang Y,Prasad PV,Edelman RR,Awad IA

    更新日期:2014-07-01 00:00:00

  • Constructing pre- and post-tests in a medical student elective.

    abstract::The importance of evaluating medical student performance has been widely addressed in the medical education literature. Multiple-choice examinations are the preferred method of testing because they are easy to administer and score. Development of parallel or equivalent pre- and post-examinations provides objective inf...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:

    authors: Blane CE,Calhoun JG,Vydareny KH

    更新日期:1986-09-01 00:00:00

  • Tubal sterilization by selective catheterization in an animal model.

    abstract:RATIONAL AND OBJECTIVES:The feasibility of tubal occlusion by selective salpingography was tested in an animal model; three novel occluding materials also were tested for this application. METHODS:Unilateral selective salpingography was performed in three groups of six rabbits; fallopian tubes were embolized with etha...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199402000-00007

    authors: Maubon A,Rouanet JP,Laurent A,Joujoux JM,Cover S,Courtieu C,Wassef M,Godlewski G,Honiger J,Lopez FM

    更新日期:1994-02-01 00:00:00

  • The use of continuous and discrete confidence judgments in receiver operating characteristic studies of diagnostic imaging techniques.

    abstract::Virtually all receiver operating characteristic (ROC) studies of medical imaging methods have involved data collected on a discrete confidence-rating scale, though in principle ROC studies can be conducted with either discrete or continuous scales. Continuous scales provide potential advantages in medical applications...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199202000-00016

    authors: Rockette HE,Gur D,Metz CE

    更新日期:1992-02-01 00:00:00

  • The effect of some iodinated contrast media on human plasma butyrylcholinesterase activity.

    abstract::The effect of three iodinated contrast media (CM) on human plasma butyrylcholinesterase (BuChE) activity was studied during the intravenous pyelography (i.v.P). BuChE is an enzyme that participates in the metabolism of acetylcholine and hydrolyzes food esters and drugs such as nondepolarizing muscle relaxants and loca...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199805000-00008

    authors: Mironidou M,Ximitidou O,Christopoulos S,Kokkas B

    更新日期:1998-05-01 00:00:00

  • Protective effects of corticosteroids in contrast material anaphylaxis.

    abstract::A prospective, randomized study of the potential protective effects of corticosteroids administered as pretreatment against contrast material (CM) reactions is reported. Patients (n = 6,763) from multiple institutions received either a single dose of steroids (32 mg of oral methylprednisolone, approximately 2 hours be...

    journal_title:Investigative radiology

    pub_type: 临床试验,杂志文章,多中心研究,随机对照试验

    doi:10.1097/00004424-198809001-00035

    authors: Lasser EC,Berry CC,Talner LB,Santini LC,Lang EK,Gerber FH,Stolberg HO

    更新日期:1988-09-01 00:00:00

  • Correlation of Histological Vessel Characteristics and Diffusion-Weighted Imaging Intravoxel Incoherent Motion-Derived Parameters in Pancreatic Ductal Adenocarcinomas and Pancreatic Neuroendocrine Tumors.

    abstract:OBJECTIVE:To investigate the correlation between intravoxel incoherent motion (IVIM) model-derived parameters and histologically determined microvascularity in pancreatic ductal adenocarcinomas (PDACs) and pancreatic neuroendocrine tumors (PNETs). MATERIALS AND METHODS:From April 2013 to May 2014, 42 patients with mal...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000187

    authors: Klau M,Mayer P,Bergmann F,Maier-Hein K,Hase J,Hackert T,Kauczor HU,Grenacher L,Stieltjes B

    更新日期:2015-11-01 00:00:00

  • Quantification of Aortic Stiffness by Ultrasound Time-Harmonic Elastography: The Effect of Intravascular Pressure on Elasticity Measures in a Porcine Model.

    abstract:OBJECTIVES:The aim of this study was to investigate blood pressure dependency of ultrasound time-harmonic elastography (THE) for quantification of aortic stiffness. MATERIALS AND METHODS:Thoracoabdominal aortas were surgically removed from 9 healthy domestic pigs and prepared for elastographic experiments. All vessels...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000618

    authors: Schaafs LA,Tzschätzsch H,Steffen IG,Braun J,Hamm B,Sack I,Elgeti T

    更新日期:2020-03-01 00:00:00

  • New contrast media designed for x-ray energy subtraction imaging in digital mammography.

    abstract:RATIONALE AND OBJECTIVES:In contrast-enhanced dual-energy subtraction imaging 2 images acquired postcontrast media administration at different energies are subtracted to highlight structures hidden in the absence of contrast media. X-ray spectra of the newly developed digital full-field mammography units (GE Senographe...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/01.RLI.0000077124.24140.bd

    authors: Lawaczeck R,Diekmann F,Diekmann S,Hamm B,Bick U,Press WR,Schirmer H,Schön K,Weinmann HJ

    更新日期:2003-09-01 00:00:00

  • Toward the Clinical Development and Validation of a Thy1-Targeted Ultrasound Contrast Agent for the Early Detection of Pancreatic Ductal Adenocarcinoma.

    abstract::Early detection of pancreatic ductal adenocarcinoma (PDAC) represents the most significant step toward the treatment of this aggressive lethal disease. Previously, we engineered a preclinical Thy1-targeted microbubble (MBThy1) contrast agent that specifically recognizes Thy1 antigen overexpressed in the vasculature of...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000697

    authors: Bam R,Daryaei I,Abou-Elkacem L,Vilches-Moure JG,Meuillet EJ,Lutz A,Marinelli ER,Unger EC,Gambhir SS,Paulmurugan R

    更新日期:2020-11-01 00:00:00

  • Role of red blood cell deformation in toxicity of contrast media in cerebral angiography.

    abstract::The authors investigated the effect on the brain of red blood cells that had been modified by contrast media. Rat blood was mixed with an equivolume of contrast media, and up to 200 microL of the mixture was infused to the internal carotid artery of the rat. Evans blue was administered intravenously to assess the inte...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198905000-00009

    authors: Miyazawa T,Nakagawa H,Oshino N

    更新日期:1989-05-01 00:00:00

  • Multiplanar reconstruction in magnetic resonance evaluation of the knee. Comparison with film magnetic resonance interpretation.

    abstract:RATIONALE AND OBJECTIVES:At many institutions, three-dimensional magnetic resonance imaging (MRI) is routinely used for examination of the knee. Multiplanar reconstruction (MPR) is a method of displaying three-dimensional datasets. The authors assessed the usefulness of MPR for evaluating knee MRI datasets by comparing...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199302000-00011

    authors: Gay SB,Chen NC,Burch JJ,Gleason TR,Sagman AM

    更新日期:1993-02-01 00:00:00

  • Pyelovenous and pyelolymphatic backflow during retrograde pyelography in renal vein thrombosis.

    abstract::Pyelovenous and pyelolymphatic backflow have been observed during retrograde pyelography in three patients with renal vein thrombosis. The radiographic patterns of backflow following experimental unilateral renal vein occlusion in rabbits were analyzed and correlated with the clinical findings. Capsular, perihilar, pe...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198101000-00003

    authors: Bidgood WD Jr,Cuttino JT Jr,Clark RL,Volberg FM

    更新日期:1981-01-01 00:00:00

  • Dual Plasma Sampling Method to Determine the Hepatic and Renal Clearance of the 2 Diastereoisomers of Gd-EOB-DTPA.

    abstract:OBJECTIVES:The aim of this study was to develop a method to determine hepatic and renal clearance of the 2 diastereoisomers (Gd-A, Gd-B) of Gd-EOB-DTPA separately. MATERIALS AND METHODS:Between July 2017 and February 2018, 41 patients with hepatic disease were prospectively included. For each patient, 1 mL of iopromid...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000622

    authors: Yuan X,Wang S,Shi W,Cai Y,Chen Y,Chen M,Peng Y,Ao G

    更新日期:2020-03-01 00:00:00

  • Low tube voltage improves computed tomography imaging of delayed myocardial contrast enhancement in an experimental acute myocardial infarction model.

    abstract:OBJECTIVE:We sought to evaluate the influence of tube voltage on the visualization of acute myocardial infarction (MI) in cardiac multislice spiral computed tomography (MSCT). MATERIALS AND METHODS:Acute MI was induced in 12 domestic pigs by a 45-minute balloon occlusion of the left anterior descending artery. Delayed...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/01.rli.0000251577.68223.84

    authors: Mahnken AH,Bruners P,Mühlenbruch G,Emmerich M,Hohl C,Günther RW,Wildberger JE

    更新日期:2007-02-01 00:00:00

  • Delayed Gadolinium Leakage in Ocular Structures: A Potential Marker for Age- and Vascular Risk Factor-Related Small Vessel Disease?

    abstract:BACKGROUND:Gadolinium leakage in ocular structures (GLOS) was recently observed in fluid-attenuated inversion recovery (FLAIR) images obtained the day after an initial gadolinium injection in stroke patients. The specificity of GLOS to stroke and its mechanisms remain unclear. OBJECTIVE:We investigated the factors ass...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000757

    authors: Galmiche C,Moal B,Marnat G,Sagnier S,Schweitzer C,Dousset V,Sibon I,Tourdias T

    更新日期:2021-01-19 00:00:00

  • Pulmonary density distribution in experimental noncardiac canine pulmonary edema evaluated by computed transmission tomography.

    abstract::We evaluated the density distribution (anterior-posterior) of the right lung in 19 acutely anesthetized supine dogs using computed transmission tomography (CTT). Eleven dogs served as controls, and eight received 0.12 cc/kg of intravenously administered oleic acid. The latter were sequentially imaged over 1 hour. Nine...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:

    authors: Slutsky RA,Long S,Peck WW,Higgins CB,Mattrey R

    更新日期:1984-05-01 00:00:00

  • Reduction of Metal Artifacts and Improvement in Dose Efficiency Using Photon-Counting Detector Computed Tomography and Tin Filtration.

    abstract:OBJECTIVES:The aim of this study was to investigate the impact on metal artifacts and dose efficiency of using a tin filter in combination with high-energy threshold (TH) images of a photon-counting detector (PCD) computed tomography (CT) system. MATERIALS AND METHODS:A 3D-printed spine with pedicle screws was scanned...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000535

    authors: Zhou W,Bartlett DJ,Diehn FE,Glazebrook KN,Kotsenas AL,Carter RE,Fletcher JG,McCollough CH,Leng S

    更新日期:2019-04-01 00:00:00

  • Contrast media for CT. An analysis of the early pharmacokinetics.

    abstract::Iohexol and meglumine-sodium diatrizoate were injected intravenously into 18 pigs as either a 99:1 or 1:99 mixture. Blood samples were taken for 30 minutes and the concentration of each of the two contrast media was measured by means of a double labeling technique with 125I and 131I. Relative concentrations of iohexol...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198511000-00016

    authors: Jensen LI,Dean PB,Nyman U,Golman K

    更新日期:1985-11-01 00:00:00

  • Comparison of Fenestra VC Contrast-enhanced computed tomography imaging with gadopentetate dimeglumine and ferucarbotran magnetic resonance imaging for the in vivo evaluation of murine liver damage after ischemia and reperfusion.

    abstract:OBJECTIVES:Comparison of intravenous Fenestra VC-enhanced computed tomography (CT) with gadopentetate dimeglumine and Ferucarbotran contrast-enhanced magnetic resonance imaging (MRI) for the in vivo imaging of hepatic ischemia/reperfusion injury (IRI) in a murine model. MATERIAL AND METHODS:After induction of hepatic ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e318155aa2e

    authors: Choukèr A,Lizak M,Schimel D,Helmberger T,Ward JM,Despres D,Kaufmann I,Bruns C,Löhe F,Ohta A,Sitkovsky MV,Klaunberg B,Thiel M

    更新日期:2008-02-01 00:00:00

  • Normal renal blood flow measurement using phase-contrast cine magnetic resonance imaging.

    abstract:RATIONALE AND OBJECTIVES:This study assesses the ability of a cardiac-gated phase-contrast magnetic resonance imaging (MRI) technique to measure renal blood flow (RBF) noninvasively in humans. METHODS:In nine normal volunteers, total RBF in the renal arteries and in the left renal vein was estimated by MRI and correla...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199206000-00012

    authors: Sommer G,Noorbehesht B,Pelc N,Jamison R,Pinevich AJ,Newton L,Myers B

    更新日期:1992-06-01 00:00:00

  • Long-term effect of irradiation on lymph node uptake of interstitially delivered nanoparticulate contrast media.

    abstract:RATIONALE AND OBJECTIVES:To characterize the long-term effects of therapeutic doses of ionizing radiation on the uptake and distribution of percutaneously delivered particulate contrast media in normal lymph nodes. METHODS:Two milliliters of an iodinated nanoparticle suspension (76 mg I/mL) was injected subcutaneously...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-200003000-00007

    authors: Wisner ER,Théon A,Griffey SM,McIntire GL

    更新日期:2000-03-01 00:00:00

  • Magnetic resonance imaging of acute myocardial infarction using a nitroxyl spin label (PCA).

    abstract::The effects of an intravenously administered nitroxyl spin label (PCA) on the magnetic resonance imaging (MRI) appearance and relaxation times of acute canine myocardial infarctions were studied. Twenty-four hours after ligation of the left anterior descending coronary artery (LAD), animals were either sacrificed imme...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:

    authors: McNamara MT,Wesbey GE,Brasch RC,Sievers R,Lipton MJ,Higgins CB

    更新日期:1985-09-01 00:00:00

  • A direct comparison of noninvasive coronary angiography by electron beam tomography and navigator-echo-based magnetic resonance imaging for the detection of restenosis following coronary angioplasty.

    abstract:RATIONALE AND OBJECTIVES:To compare electron beam tomography (EBT) with MR imaging (MRI) for detection of restenosis after coronary angioplasty (PTCA). METHODS:One hundred eighteen patients after PTCA were investigated. By EBT, 50 axial images were acquired (3-mm slice thickness, 120-160 mL radiographic contrast agent...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-200207000-00005

    authors: Ropers D,Regenfus M,Stilianakis N,Birke S,Kessler W,Moshage W,Laub G,Daniel WG,Achenbach S

    更新日期:2002-07-01 00:00:00

  • Solid, part-solid, or non-solid?: classification of pulmonary nodules in low-dose chest computed tomography by a computer-aided diagnosis system.

    abstract:OBJECTIVES:The purpose of this study was to develop and validate a computer-aided diagnosis (CAD) tool for automatic classification of pulmonary nodules seen on low-dose computed tomography into solid, part-solid, and non-solid. MATERIALS AND METHODS:Study lesions were randomly selected from 2 sites participating in t...

    journal_title:Investigative radiology

    pub_type: 临床试验,杂志文章,多中心研究,随机对照试验

    doi:10.1097/RLI.0000000000000121

    authors: Jacobs C,van Rikxoort EM,Scholten ET,de Jong PA,Prokop M,Schaefer-Prokop C,van Ginneken B

    更新日期:2015-03-01 00:00:00

  • Quantitative computed tomography of the lungs and airways in healthy nonsmoking adults.

    abstract:OBJECTIVES:The purposes of this study were to evaluate the reference range of quantitative computed tomography (QCT) measures of lung attenuation and airway parameter measurements in healthy nonsmoking adults and to identify sources of variation in those measures and possible means to adjust for them. MATERIALS AND ME...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e318262292e

    authors: Zach JA,Newell JD Jr,Schroeder J,Murphy JR,Curran-Everett D,Hoffman EA,Westgate PM,Han MK,Silverman EK,Crapo JD,Lynch DA,COPDGene Investigators.

    更新日期:2012-10-01 00:00:00

  • Consistency of rotator-cuff calcifications. Observations on plain radiography, sonography, computed tomography, and at needle treatment.

    abstract:RATIONALE AND OBJECTIVES:The author analyzes findings of consistency of rotator-cuff calcifications found at ultrasound (US)-guided needle treatment compared with findings of plain radiography, US, and computed tomography (CT). METHODS:Twenty patients had rotator-cuff calcifications (mean diameter, 1.5 cm; range, 1.1-...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199605000-00010

    authors: Farin PU

    更新日期:1996-05-01 00:00:00

  • Assessment of osteosarcoma response to preoperative chemotherapy using dynamic FLASH gadolinium-DTPA-enhanced magnetic resonance mapping.

    abstract:RATIONALE AND OBJECTIVES:To improve the accuracy of magnetic resonance imaging (MRI) in evaluating the response of osteosarcomas to preoperative chemotherapy, the authors developed a technique of mapping tumor necrosis and viability by quantitating slope values of gadolinium-DTPA (Gd-DTPA) uptake on dynamic fast low-an...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199205000-00010

    authors: Hanna SL,Parham DM,Fairclough DL,Meyer WH,Le AH,Fletcher BD

    更新日期:1992-05-01 00:00:00

  • Increased urine histamine and contrast media reactions.

    abstract::Urine samples were collected from 200 subjects undergoing intravenous pyelography. The urine histamine levels were compared with those of 132 normal control subjects, 11 subjects with systemic mastocytosis, six subjects with idiopathic anaphylaxis, and ten subjects experiencing mild anaphylactic reactions during aller...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198403000-00007

    authors: Kaliner M,Dyer J,Merlin S,Shelton A,Greenhill A,Treadwell G,McKenna W,Lieberman P

    更新日期:1984-03-01 00:00:00

  • The uptake of manganese dipyridoxal-diphosphate by chemically induced hepatocellular carcinoma in rats. A correlation between contrast-media-enhanced magnetic resonance imaging, tumor differentiation, and vascularization.

    abstract:OBJECTIVES AND RATIONALE:Negative enhancement of implanted liver tumors has been achieved in preclinical studies on manganese dipyridoxal-diphosphate (Mn-DPDP), a new hepatobiliary specific contrast agent for magnetic resonance imaging (MRI). The authors investigated the effects of Mn-DPDP on primary liver cancer and i...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199306000-00011

    authors: Ni Y,Marchal G,Zhang X,Van Hecke P,Michiels J,Yu J,Rummeny E,Lodemann KP,Baert AL

    更新日期:1993-06-01 00:00:00