Multiplanar reconstruction in magnetic resonance evaluation of the knee. Comparison with film magnetic resonance interpretation.

Abstract:

RATIONALE AND OBJECTIVES:At many institutions, three-dimensional magnetic resonance imaging (MRI) is routinely used for examination of the knee. Multiplanar reconstruction (MPR) is a method of displaying three-dimensional datasets. The authors assessed the usefulness of MPR for evaluating knee MRI datasets by comparing readers' performance using MPR and conventional film MRIs. METHODS:Eight patients with internal derangement of the knee were studied. All had MRI datasets acquired in the sagittal plane using a three-dimensional gradient-echo fast imaging with steady-state precession (FISP) sequence. Arthroscopic surgery after MRI confirmed the presence of 6 anterior cruciate ligament (ACL) tears, 11 meniscal tears, and 5 normal menisci in this group. Four blinded readers, experienced in MRI of the knee, evaluated the images. The MRI datasets were then loaded onto a three-dimensional workstation and interpreted by the same readers using MPR. The MRI findings were correlated with arthroscopy. RESULTS:For diagnosis of tears of the ACL, sensitivity was 96% and specificity was 100% for both films and MPR. For detecting meniscal tears, sensitivity was 55% and specificity was 90%, using the filmed images, versus 64% and 85%, respectively, with MPR. These differences were not statistically significant by the sign test. Total time (technologist processing time plus radiologist reading time) for MPR was greater than for film interpretation by a factor of 1.12 (P < .05), and radiologist reading time for MPR was greater by a factor of 1.88 (P < .05). CONCLUSIONS:For sagittal three-dimensional FISP MRI datasets, real-time MPR is comparable with film interpretation for evaluation of ACL and meniscal injuries, but it increases the time required for diagnosis.

journal_name

Invest Radiol

journal_title

Investigative radiology

authors

Gay SB,Chen NC,Burch JJ,Gleason TR,Sagman AM

doi

10.1097/00004424-199302000-00011

subject

Has Abstract

pub_date

1993-02-01 00:00:00

pages

142-5

issue

2

eissn

0020-9996

issn

1536-0210

journal_volume

28

pub_type

杂志文章
  • Gelatin encapsulated nitrogen microbubbles as ultrasonic contrast agents.

    abstract::Gelatin encapsulated nitrogen microbubbles were effective ultrasonic contrast agents in in vitro phantom and in vivo rabbit V2 carcinoma studies. Intra-arterial injection of 80-micrometer gelatin encapsulated nitrogen microbubbles appeared to improve tumor visualization by rim enhancement, which persisted for several ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198005000-00013

    authors: Carroll BA,Turner RJ,Tickner EG,Boyle DB,Young SW

    更新日期:1980-05-01 00:00:00

  • Intravascular ultrasound imaging of vascular responsiveness in isolated perfused canine arteries.

    abstract::We investigated the feasibility of using intravascular ultrasound imaging to analyze vascular physiology in various arterial beds. Canine superficial femoral, external iliac, and common carotid arteries were harvested and suspended and perfused in a bath of oxygenated, heated, physiologic salt solution. A 6-Fr, 20-MHz...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199103000-00010

    authors: Wilson MW,Webb RC,Marx MV,Meyer CR,Gallagher MA,Haarer SL,Buda AJ,Williams DM

    更新日期:1991-03-01 00:00:00

  • Pharmacokinetics and safety of gadobutrol-enhanced magnetic resonance imaging in pediatric patients.

    abstract:OBJECTIVES:This clinical study investigated the pharmacokinetics and safety of gadobutrol, a magnetic resonance (MR) imaging extracellular contrast agent, in pediatric patients aged 2 to 17 years. MATERIALS AND METHODS:In this open-label, multicenter study, patients scheduled for routine contrast-enhanced MR imaging o...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e3181bfe2d2

    authors: Hahn G,Sorge I,Gruhn B,Glutig K,Hirsch W,Bhargava R,Furtner J,Born M,Schröder C,Ahlström H,Kaiser S,Moritz JD,Kunze CW,Shroff M,Stokland E,Trnkova ZJ,Schultze-Mosgau M,Reif S,Bacher-Stier C,Mentzel HJ

    更新日期:2009-12-01 00:00:00

  • Slice simulation from a model of the parenchymous vascularization to evaluate texture features: work in progress.

    abstract:RATIONALE AND OBJECTIVES:To demonstrate the usefulness of a model of the parenchymous vascularization to evaluate texture analysis methods. METHODS:Slices with thickness varying from 1 to 4 mm were reformatted from a 3D vascular model corresponding to either normal tissue perfusion or local hypervascularization. Param...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199903000-00004

    authors: Rolland Y,Bézy-Wendling J,Duvauferrier R,Coatrieux JL

    更新日期:1999-03-01 00:00:00

  • Contrast media-induced renal tubular vacuolization. A light and electron microscopic study on rat kidneys.

    abstract::The morphologic changes in healthy rat kidneys (n = 102) were studied 2 or 48 hours after intravenous injection of 1 or 3 g iodine (I)/kg of high-osmolality diatrizoate, low-osmolality iopromide and iohexol, or iso-osmolality iotrolan, as well as after 0.2 or 0.6 g/kg of the high-osmolality magnetic resonance contrast...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199110000-00009

    authors: Tervahartiala P,Kivisaari L,Kivisaari R,Virtanen I,Standertskjöld-Nordenstam CG

    更新日期:1991-10-01 00:00:00

  • Specific absorption rate as a poor indicator of magnetic resonance-related implant heating.

    abstract::Recent publications of the magnetic resonance safety profile of neurostimulators, cardiac pacemakers, and other implanted devices imply that these devices are no longer a contraindication for magnetic resonance imaging. It is very promising that patients who have these implanted devices may in the future no longer be ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/01.rli.0000185898.59140.91

    authors: Nitz WR,Brinker G,Diehl D,Frese G

    更新日期:2005-12-01 00:00:00

  • Collateral arterial formation. Lymph draining ischemic kidneys contains a neovascular stimulating agent of high molecular weight.

    abstract::An agent has been identified in lymph from rat kidneys rendered ischemic by partial renal artery occlusion that induces a striking neovascular response in a hamster cheek-pouch assay system. The factor has a high molecular weight, cannot be identified in lymph from normal kidneys, and is associated with a marked incre...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198501000-00015

    authors: Hollenberg NK,Paskins-Hurlburt AJ,Abrams HL

    更新日期:1985-01-01 00:00:00

  • Magnetic resonance evaluation of regional left ventricular function. Effect of through-plane motion.

    abstract:RATIONALE AND OBJECTIVES:Measurements of segmental contraction of the left ventricle by standard magnetic resonance imaging (MRI) and two-dimensional echocardiography involve the comparison of diastolic and systolic time frames acquired from the same imaging plane in space. As the cone-shaped left ventricle shortens al...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199209000-00004

    authors: Pattynama PM,Doornbos J,Hermans J,van der Wall EE,de Roos A

    更新日期:1992-09-01 00:00:00

  • Short-term effects of a new intravascular nitinol stent in canine arteries.

    abstract:RATIONALE AND OBJECTIVES:To evaluate the short-term effects of a new nitinol stent on canine arteries. METHODS:Eighteen nitinol mesh stents were placed in abdominal aortas, common iliac arteries, and renal arteries of six dogs. Angiography was performed to evaluate the patency rates and structural changes of arteries ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199905000-00007

    authors: Lee KW,Park JH,Chung JW,Kim WS,Lee W,Yeon KM

    更新日期:1999-05-01 00:00:00

  • Fibroblast response to gadolinium: role for platelet-derived growth factor receptor.

    abstract:OBJECTIVE:The purpose of this study was to assess the effects of gadolinium (Gd3+), provided as gadolinium chloride, on fibroblast function. MATERIALS AND METHODS:Human dermal fibroblasts in monolayer culture and intact skin in organ culture were exposed to the lanthanide metal (1-20 μM). RESULTS:Increased proliferat...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e3181e943d2

    authors: Bhagavathula N,Dame MK,DaSilva M,Jenkins W,Aslam MN,Perone P,Varani J

    更新日期:2010-12-01 00:00:00

  • Ultrasonic detection of osteomyelitis. Pathologic correlation in an animal model.

    abstract::The authors correlated sonographic findings with histologic findings in a rabbit model of osteomyelitis. Staphylococcus aureus osteomyelitis was induced in the femora of 11 New Zealand white rabbits. The opposite leg was used as a control. Sonographic findings showed fluid adjacent to the bone in 11 cases. The fluid w...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199202000-00002

    authors: Abiri MM,DeAngelis GA,Kirpekar M,Abou AN,Ablow RC

    更新日期:1992-02-01 00:00:00

  • The importance of nuclear magnetic relaxation dispersion (NMRD) profiles in MRI contrast media development.

    abstract::Observation of the relaxivity of MRI contrast media over a wide range of magnetic fields is not only necessary for predicting their efficiency at any field but also compulsory for understanding and improving their mechanisms of action. The best experimental approach to this problem is the field cycling method, which a...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198809001-00047

    authors: Muller RN,Vander Elst L,Rinck PA,Vallet P,Maton F,Fischer H,Roch A,Van Haverbeke Y

    更新日期:1988-09-01 00:00:00

  • Fluorinated blood substitute retention in the rat measured by fluorine-19 magnetic resonance imaging.

    abstract:RATIONALE AND OBJECTIVES:Emulsions of perfluorocarbons (PFCs) have been tested as blood substitutes. However, evidence exists that there is long-term retention of some PFCs by the organs of the reticuloendothelial system (RES). The authors investigate organ retention of the blood substitute component, perfluorotripropy...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199208000-00012

    authors: Meyer KL,Carvlin MJ,Mukherji B,Sloviter HA,Joseph PM

    更新日期:1992-08-01 00:00:00

  • Alteration of human tumor cell adhesion by high-strength static magnetic fields.

    abstract:RATIONALE AND OBJECTIVES:The authors investigated whether the ability of human malignant melanoma cells to increase in cell number or their ability to remain viable was compromised by high-field strength static magnetic fields. Normal human fibroblasts also were studied to determine if any magnetic field-related altera...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199210000-00014

    authors: Short WO,Goodwill L,Taylor CW,Job C,Arthur ME,Cress AE

    更新日期:1992-10-01 00:00:00

  • Value of in vivo T2 measurement for myocardial fibrosis assessment in diabetic mice at 11.75 T.

    abstract:OBJECTIVE:The aim of the study was to assess the value of in vivo T2 measurements to noninvasively quantify myocardial fibrosis in diabetic mice at 11.75 T. Diabetic cardiomyopathy is characterized by extracellular matrix alteration and microcirculation impairment. These conditions might provide electrical heterogeneit...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e318243e062

    authors: Bun SS,Kober F,Jacquier A,Espinosa L,Kalifa J,Bonzi MF,Kopp F,Lalevee N,Zaffran S,Deharo JC,Cozzone PJ,Bernard M

    更新日期:2012-05-01 00:00:00

  • Contrast-enhanced MRI of tumors. Comparison of Gd-DTPA and a macromolecular agent.

    abstract::The study aim was to define potential differences and advantages in magnetic resonance (MR) patterns of tumoral contrast enhancement using either a small molecular, extracellular fluid contrast enhancer [Gd-DTPA] or a macromolecular agent [albumin-(Gd-DTPA)20], designed for primary intravascular biodistribution. MR im...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198908000-00007

    authors: Wikström MG,Moseley ME,White DL,Dupon JW,Winkelhake JL,Kopplin J,Brasch RC

    更新日期:1989-08-01 00:00:00

  • Effect of lumbar puncture on flow of cerebrospinal fluid.

    abstract::The rate at which isotopes descend from the cisterna magna to the lumbar subarachnoid space is highly variable. In monkeys, with and without previous lumbar puncture, transit time was measured. In animals with a previous lumbar puncture, transit times were 10 to 120 minutes; in monkeys without a previous lumbar punctu...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198805000-00005

    authors: Lipman B,Palmer D,Noble J,Haughton V,Collier D

    更新日期:1988-05-01 00:00:00

  • Changes in complement and coagulation factors in a patient suffering a severe anaphylactoid reaction to injected contrast material: some considerations of pathogenesis.

    abstract::A patient, suffering a severe anaphylactoid reaction to contrast material injected for an intravenous pyelogram, developed a consumption coagulopathy and evidence of complement activation. Precontrast complement values suggested that the patient had been processing complement via the classical pathway, perhaps as a co...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198011001-00004

    authors: Lasser EC,Lang JH,Lyon SG,Hamblin AE

    更新日期:1980-11-01 00:00:00

  • Dual source dual energy MDCT: comparison of 80 kVp and weighted average 120 kVp data for conspicuity of hypo-vascular liver metastases.

    abstract:PURPOSE:To determine whether liver metastases conspicuity is improved at 80 kVp when compared with weighted average (WA) simulated 120 kVp data using dual source dual energy CT. METHODS:A total of 11 patients with 44 hypo-vascular liver metastases underwent contrast enhanced Dual Energy CT (DECT). In all cases the sub...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e3181dfda78

    authors: Robinson E,Babb J,Chandarana H,Macari M

    更新日期:2010-07-01 00:00:00

  • Characterization of ultrasmall magnetite [correction of paramagnetic magnetite] particles as superparamagnetic contrast agents in MRI.

    abstract:RATIONALE AND OBJECTIVES:Very small dextran-coated magnetite particles were developed. These particles can be used either as immunospecific contrast agents for MRI by coupling to antibodies or as an interstitial contrast agent. METHODS:The particles were synthesized from iron chloride/dextran solutions. Size was evalu...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-200009000-00006

    authors: Grimm J,Karger N,Lüsse S,Winoto-Morbach S,Krisch B,Müller-Hülsbeck S,Heller M

    更新日期:2000-09-01 00:00:00

  • Role of iodinated contrast material in the evaluation of myocardial infarction by computerized transmission tomography.

    abstract::In vivo and in vitro studies have shown that areas of myocardial infarctions can be delineated on CT scans after intravenous administration of iodinated contrast material to dogs with experimental myocardial infarctions. Within the first minute after intravenous administration of contrast material (initial myocardial ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198011001-00039

    authors: Higgins CB,Siemers PT,Newell JD,Schmidt W

    更新日期:1980-11-01 00:00:00

  • The etiology and implications of dense cavitary "photopenia" on myocardial perfusion scintigraphy.

    abstract::Dense cavitary "photopenia" was observed on 21 of 200 consecutive stress perfusion scintigrams. A prominent finding in many cases, it sometimes occupied only a portion of the region overlying the ventricular cavity, was often seen in some projections and not others, and was frequently adjacent to myocardial perfusion ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198507000-00009

    authors: Dae M,Canhasi B,Botvinick E,Olvera S,Schechtmann N,Engelstad B,Hattner R,Schiller N,O'Connell W,Faulkner D

    更新日期:1985-07-01 00:00:00

  • The retropsoas recess. Demonstration using computed tomography.

    abstract::The retropsoas recess, a previously undescribed normal anatomic variant, is reported. In most individuals, the space posterior to the belly of the psoas muscle contains fat within the posterior pararenal space. However, a retrospective review of 250 consecutive CT examinations of the abdomen revealed 11 cases (4.4%) i...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198707000-00004

    authors: Kelly RB,Mahoney PD,Frick MP

    更新日期:1987-07-01 00:00:00

  • Curved reconstructions versus three-dimensional surface rendering in the demonstration of cortical lesions in patients with extratemporal epilepsy.

    abstract:RATIONALE AND OBJECTIVES:To compare the visibility and localization of extratemporal cortical lesions in extratemporal epilepsy by using curved reconstruction (CR) and three-dimensional surface rendering (3D SR) of 3D-acquired MR images and to study the degree of confidence with which localizations are made, particular...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-200104000-00005

    authors: Meiners LC,Scheffers JM,De Kort GA,Burger H,Van Huffelen AC,Van Rijen PC,Van Veelen CW

    更新日期:2001-04-01 00:00:00

  • Semiquantitative assessment of myocardial perfusion using magnetic resonance imaging: evaluation of appropriate thresholds and segmentation models.

    abstract:RATIONALE AND OBJECTIVES:The aim of the study was to determine optimal thresholds for semiquantitative perfusion parameters and to evaluate the influence of different segmentation models in detecting malperfused regions. MATERIAL AND METHODS:In 6 healthy subjects and 13 patients with coronary artery disease, contrast-...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/01.rli.0000133816.83192.38

    authors: Fenchel M,Kramer U,Helber U,Stauder NI,Franow A,Claussen CD,Miller S

    更新日期:2004-09-01 00:00:00

  • High permittivity dielectric pads improve high spatial resolution magnetic resonance imaging of the inner ear at 7 T.

    abstract:OBJECTIVES:The objective of this study was to evaluate the use of dielectric pads for improving high spatial resolution imaging of the inner ear at 7 T. MATERIALS AND METHODS:Two sets of dielectric pads were designed using electromagnetic simulations and implemented using a deuterated suspension of barium titanate. Th...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000026

    authors: Brink WM,van der Jagt AM,Versluis MJ,Verbist BM,Webb AG

    更新日期:2014-05-01 00:00:00

  • Correlation of flow velocity measurements by magnetic resonance phase contrast imaging and intravascular Doppler ultrasound.

    abstract:RATIONALE AND OBJECTIVES:The authors compare the magnetic resonance (MR) phase contrast flow velocity measurements in varying concentric stenoses with invasive measurements obtained with a Doppler guidewire. METHODS:Flow velocity measurements were obtained using a calibrated 0.018 inch 12 MHz Doppler guidewire and a 1...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199808000-00001

    authors: Hoppe M,Heverhagen JT,Froelich JJ,Kunisch-Hoppe M,Klose KJ,Wagner HJ

    更新日期:1998-08-01 00:00:00

  • Effect of increasing current and decreasing blood flow for transcatheter electrocoagulation (TCEC).

    abstract::Arterial occlusion by direct-current transcatheter electrocoagulation (TCEC) has been developed experimentally and used successfully in clinical situations. The major shortcoming of the technique has been the lengthy time necessary for occlusion of larger arteries. In the present study we attempted to decrease the tim...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198203000-00011

    authors: Ralston MD,Woodfield S,Halvorsen R,Pizzo SV,Thompson WM

    更新日期:1982-03-01 00:00:00

  • Magnetic resonance imaging assays for dimethyl sulfoxide effect on cancer vasculature.

    abstract:OBJECTIVES:To evaluate the potential of quantitative assays of vascular characteristics based on dynamic contrast-enhanced magnetic resonance imaging (MRI) using a macromolecular contrast medium (MMCM) to search for and measure effects of dimethyl sulfoxide (DMSO) on cancer vasculature with microscopic correlations. M...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e318164b71d

    authors: Cyran CC,Sennino B,Chaopathomkul B,Fu Y,Rogut V,Shames DM,Wendland MF,McDonald DM,Brasch RC

    更新日期:2008-05-01 00:00:00

  • Magnetization transfer and high-dose contrast in early brain infection on magnetic resonance.

    abstract:RATIONALE AND OBJECTIVES:The authors studied the effect of contrast dose, use of magnetization transfer (MT), and temporal delay on the visualization of contrast enhancement with gadoteridol (Gd HP-DO3A) in a canine brain abscess model. METHODS:Alpha streptococcus brain abscesses were studied in five dogs at 1.5 tesla...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199503000-00001

    authors: Runge VM,Wells JW,Kirsch JE

    更新日期:1995-03-01 00:00:00