Abstract:
OBJECTIVE:The purpose of this study was to assess the ability of a flow-sensitive alternating inversion recovery-arterial spin labeling (FAIR-ASL) technique to track renal perfusion changes during pharmacologic and physiologic alterations in renal blood flow using microspheres as a gold standard. MATERIALS AND METHODS:Fluorescent microsphere and FAIR-ASL perfusion were compared in the cortex of the kidney for 11 swine across 4 interventional time points: (1) under baseline conditions, (2) during an acetylcholine and fluid bolus challenge to increase perfusion, (3) initially after switching to isoflurane anesthesia, and (4) after 2 hours of isoflurane anesthesia. In 10 of the 11 swine, a bag of ice was placed on the hilum of 1 kidney at the beginning of isoflurane administration to further reduce perfusion in 1 kidney. RESULTS:Both ASL and microspheres tracked the expected cortical perfusion changes (P < 0.02) across the interventions, including an increase in perfusion during the acetylcholine challenge and decrease during the administration of isoflurane. Both techniques also measured lower cortical perfusion in the iced compared with the non-iced kidneys (P ≤ 0.01). The ASL values were systematically lower compared with microsphere perfusion. Very good correlation (r = 0.81, P < 0.0001) was observed between the techniques, and the relationship appeared linear for perfusion values in the expected physiologic range (microsphere perfusion <550 mL/min/100 g) although ASL values saturated for perfusion >550 mL/min/100 g. CONCLUSION:Cortical perfusion measured with ASL correlated with microspheres and reliably detected changes in renal perfusion in response to physiologic challenge.
journal_name
Invest Radioljournal_title
Investigative radiologyauthors
Artz NS,Wentland AL,Sadowski EA,Djamali A,Grist TM,Seo S,Fain SBdoi
10.1097/RLI.0b013e3181f5e101subject
Has Abstractpub_date
2011-02-01 00:00:00pages
124-31issue
2eissn
0020-9996issn
1536-0210pii
00004424-201102000-00006journal_volume
46pub_type
杂志文章abstract::The importance of evaluating medical student performance has been widely addressed in the medical education literature. Multiple-choice examinations are the preferred method of testing because they are easy to administer and score. Development of parallel or equivalent pre- and post-examinations provides objective inf...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:
更新日期:1986-09-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:Paclitaxel added to angiographic contrast medium (CM) has been shown to inhibit restenosis in the porcine coronary overstretch model. This study determined early local tissue concentrations after the administration of different paclitaxel doses and preparations. MATERIALS AND METHODS:Fifteen p...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/01.rli.0000116125.96544.64
更新日期:2004-03-01 00:00:00
abstract::We compared the damage resulting from intradermal injection of four commonly used radiographic contrast media in laboratory rats. Sixty percent meglumine diatrizoate (Reno M 60) and ioxaglate (Hexabrix) produced significantly more ulceration and crusting on gross inspection and more necrosis, edema, and hemorrhage on ...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199005000-00006
更新日期:1990-05-01 00:00:00
abstract::In this article, we propose a semiautomatic method for time-continuous contour detection in all phases of the cardiac cycle in magnetic resonance sequences. The method is based on multidimensional dynamic programming. After shape parameterization, cost hypercubes are filled with image-feature derived cost function val...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/01.rli.0000194070.88432.24
更新日期:2006-01-01 00:00:00
abstract::Observer performance in radiologic interpretation has traditionally been based upon Receiver Operating Characteristic (ROC) analysis. A statistical method that evaluates the reproducibility or consistency of radiologic interpretation is presented. Since this method is not based upon pathologic verification, it cannot ...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198411000-00024
更新日期:1984-11-01 00:00:00
abstract::Post-angioplasty restenosis (PARS) in atherosclerotic lesions of medium and small arteries occurs in about one-third of cases in the first year following percutaneous transluminal angioplasty (PTA) (early PARS). PARS includes acute spasm, dissection with reclosure, elastic recoil, fibrocellular proliferative response,...
journal_title:Investigative radiology
pub_type: 临床试验,杂志文章,多中心研究
doi:10.1097/00004424-198811000-00002
更新日期:1988-11-01 00:00:00
abstract:OBJECTIVES:The aims of this study were to present a deep learning approach for the automated classification of multiple sclerosis and its mimics and compare model performance with that of 2 expert neuroradiologists. MATERIALS AND METHODS:A total of 268 T2-weighted and T1-weighted brain magnetic resonance imagin scans ...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0000000000000735
更新日期:2020-10-26 00:00:00
abstract:RATIONALE AND OBJECTIVES:The reflux of ethanol into the peritoneal cavity during percutaneous ethanol injection therapy (PEIT) of liver neoplasms may cause pain and other side effects. This article studies the optimal injection technique to minimize the reflux of ethanol. METHODS:A technique using normal postmortem pi...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199211000-00008
更新日期:1992-11-01 00:00:00
abstract:OBJECTIVE:The aim of this study was to compare changes in the signal intensity (SI) ratio of the dentate nucleus (DN) to the pons, DN to cerebrospinal fluid (CSF), and globus pallidus (GP) to thalamus on unenhanced T1-weighted magnetic resonance imaging (MRI) scans after serial injections of the macrocyclic gadolinium-...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0000000000000227
更新日期:2015-12-01 00:00:00
abstract::Erythrocytes at various concentrations were examined with a sensitive A-mode ultrasonic scanner; simultaneous measurements were made under light microscopic control. Individual erythrocytes caused weak (about 1 dB) echoes while erythrocyte aggregates (ten to 100 cells) produced stronger echoes (up to 15 dB), grossly p...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198508000-00014
更新日期:1985-08-01 00:00:00
abstract:OBJECTIVES:Over the recent years, there have been increasing concerns that exposure to gadolinium-based contrast agents (GBCAs) may be associated with retention of Gd within the skin, bones, and solid organs in patients with normal renal function, although the clinical implications of this deposition remain to be estab...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0000000000000657
更新日期:2020-07-01 00:00:00
abstract:OBJECTIVES:The aim of this study was to assess the impact of oral water and intravenous furosemide challenges on blood oxygenation level-dependent magnetic resonance imaging measurements in the kidney and to examine the contribution of R2 (=1/T2) to changes in R2* (=1/T2*). MATERIALS AND METHODS:This Health Insurance ...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0b013e3182823591
更新日期:2013-07-01 00:00:00
abstract::The effects of an intravenously administered nitroxyl spin label (PCA) on the magnetic resonance imaging (MRI) appearance and relaxation times of acute canine myocardial infarctions were studied. Twenty-four hours after ligation of the left anterior descending coronary artery (LAD), animals were either sacrificed imme...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:
更新日期:1985-09-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:To demonstrate the usefulness of a model of the parenchymous vascularization to evaluate texture analysis methods. METHODS:Slices with thickness varying from 1 to 4 mm were reformatted from a 3D vascular model corresponding to either normal tissue perfusion or local hypervascularization. Param...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199903000-00004
更新日期:1999-03-01 00:00:00
abstract::Four-hour delayed contrast-enhanced computed tomography (DCECT) shows promise for improved detection of focal liver lesions. No previous studies have examined the use of nonionic contrast materials for DCECT. The authors undertook a case-controlled study in monkeys to define the relative efficacies of iopamidol and di...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198910000-00010
更新日期:1989-10-01 00:00:00
abstract::We evaluated the density distribution (anterior-posterior) of the right lung in 19 acutely anesthetized supine dogs using computed transmission tomography (CTT). Eleven dogs served as controls, and eight received 0.12 cc/kg of intravenously administered oleic acid. The latter were sequentially imaged over 1 hour. Nine...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:
更新日期:1984-05-01 00:00:00
abstract::Blood samples from previous contrast reactors and nonreactor controls were incubated with diatrizoate and several contrast analogues. Total complement levels were assayed. All the agents caused complement activation generally proportional to their concentration. Reactors' sera responded to lower concentrations of cont...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198307000-00018
更新日期:1983-07-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:The authors investigated whether the ability of human malignant melanoma cells to increase in cell number or their ability to remain viable was compromised by high-field strength static magnetic fields. Normal human fibroblasts also were studied to determine if any magnetic field-related altera...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199210000-00014
更新日期:1992-10-01 00:00:00
abstract::Effectiveness of terbutaline, a potent uterine muscle relaxant, for differentiation of temporary and anatomic interstitial fallopian tube obstruction (IFTO) at hysterosalpingography (HSG) was explored. In 43 IFTO evaluated, HSG after terbutaline showed patency in only one of 16 tubes in which IFTO was caused by spasm ...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198803000-00010
更新日期:1988-03-01 00:00:00
abstract::A patient, suffering a severe anaphylactoid reaction to contrast material injected for an intravenous pyelogram, developed a consumption coagulopathy and evidence of complement activation. Precontrast complement values suggested that the patient had been processing complement via the classical pathway, perhaps as a co...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198011001-00004
更新日期:1980-11-01 00:00:00
abstract::The application of intravenous, intrathecal, and inhalation enhancement techniques to the CT evaluation of the nonhuman primate (Papio cynocephalus/anubis) is described. The falx cerebri cortical vasculature, vein of Galen, straight sinus and tentorium cerebelli were defined with intravenous enhancement. Intrathecal C...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-197901000-00014
更新日期:1979-01-01 00:00:00
abstract:OBJECTIVES:Contrast-enhanced ultrasound imaging is increasingly being used in the clinic for assessment of tissue vascularity. The purpose of our study was to evaluate the effect of different contrast administration parameters on the in vivo ultrasound imaging signal in tumor-bearing mice using a maximum intensity pers...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0b013e3181f9202d
更新日期:2011-03-01 00:00:00
abstract:OBJECTIVES:Altered systolic blood flow in the ascending aorta has been correlated with increased aortic growth in patients with bicuspid aortic valves (BAVs). We used conventional, 2-dimensional (2D) phase contrast magnetic resonance imaging (PC-MRI) to assess the relationship between altered flow and future growth in ...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0000000000000064
更新日期:2014-10-01 00:00:00
abstract:OBJECTIVE:To evaluate the effectiveness of a dual magnetic resonance-near infrared fluorescence optical imaging agent, poly(l-glutamic acid)-DTPA-Gd-NIR813, for both preoperative and intraoperative visualization and characterization of sentinel lymph nodes (SLN) in mice. MATERIALS AND METHODS:Poly(L-glutamic acid) was...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0b013e31804f5a79
更新日期:2007-08-01 00:00:00
abstract::Previous investigations in this laboratory have confirmed the observation of facial muscle twitching during intracarotid injections of nonionic contrast media (CM) in rabbits. The reaction appears to be a locally mediated effect. To further investigate this reaction, cortical electroencephalogram (EEG) and facial elec...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199009000-00010
更新日期:1990-09-01 00:00:00
abstract::A radiographic method for use in the closed-chest dog is described which allows the quantitation of segmental mechanical performance. Previous work has shown that the area of the pressure-length loop (an approximation of a stress-strain integral) is a useful measure of the mechanical work performed by a segment of myo...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-197611000-00010
更新日期:1976-11-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:Validation of new positron emission tomography (PET) tracers or magnetic (MR) imaging contrast agents is based on isolated rodent heart preparations. The use of larger animals could provide a more direct validation using the devices used for humans. METHODS:An isolated pig heart preparation ha...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199711000-00010
更新日期:1997-11-01 00:00:00
abstract::The authors evaluated double-blind comparative and open-label clinical trials in 1,186 patients who received ioversol to evaluate the safety and efficacy of ioversol, a new nonionic low-osmolality contrast medium, at iodine concentrations of 32%, 24%, and 16%. The results indicate that ioversol was well tolerated in a...
journal_title:Investigative radiology
pub_type: 临床试验,杂志文章
doi:10.1097/00004424-198906001-00020
更新日期:1989-06-01 00:00:00
abstract:PURPOSE:The aim of this study was to develop a method to delineate the lethally frozen-tissue region (temperature less than -40°C) arising from interventional cryoablation procedures using a short tau inversion-recovery ultrashort echo-time (STIR-UTE) magnetic resonance (MR) imaging sequence. This method could serve as...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0000000000000642
更新日期:2020-05-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:To compare gadobenate dimeglumine (Gd-BOPTA) with gadopentetate dimeglumine (Gd-DTPA) for magnetic resonance imaging of the liver. METHODS:The contrast agent Gd-BOPTA or Gd-DTPA was administered at a dose of 0.1 mmol/kg to 257 patients suspected of having malignant liver tumors. Dynamic phase ...
journal_title:Investigative radiology
pub_type: 临床试验,杂志文章,随机对照试验
doi:10.1097/00004424-200111000-00002
更新日期:2001-11-01 00:00:00