Abstract:
AIM:: We sought to improve the clinical interpretation of first-pass myocardial magnetic resonance perfusion. Parametric analyses of the myocardial distribution of the contrast agent have been proposed. The objective of the present study was to compare the effectiveness of visual analysis and of a parametric approach in an animal model under acquisition conditions as close as possible to clinical reality. METHOD:: Experiments were conducted in vivo with various kinds of pharmacological stimulation in normal pigs and in pigs with stenosis of the left circumflex coronary artery. First-pass MR images and parametric maps were first assessed by medical experts. MR parameters, the myocardial signal intensity variation DeltaSI, ascending up-slope, and rMBF (blood flow calculated by fast discrete ARMA deconvolution) were then compared with blood flow measurements using radioactive microspheres. RESULTS AND CONCLUSIONS:: Interobserver agreement was 57% and 81% and accuracy 53% and 81%, for visual and for parametric map analysis, respectively. For deconvolution parameters, a linear relationship y = 371 + 1.27x, r = 0.78 was obtained between rMBF calculated by ARMA and the radioactive microsphere blood flow. Moreover, the fast and robust parametric mapping of rMBF by the discrete ARMA method allows MR evaluation of myocardial perfusion independently of hemodynamic conditions.
journal_name
Invest Radioljournal_title
Investigative radiologyauthors
Carme S,Maï W,Mazzadi A,Janier M,Revel D,Magnin I,Wiart M,Neyran B,Canet-Soulas Edoi
10.1097/01.rli.0000197980.89673.4bkeywords:
subject
Has Abstractpub_date
2006-04-01 00:00:00pages
374-83issue
4eissn
0020-9996issn
1536-0210pii
00004424-200604000-00003journal_volume
41pub_type
杂志文章abstract::The problem of inhomogeneous mixing encountered during hepatic artery (HA) chemotherapy infusion was assessed and a practical solution examined. A glass model of the human HA distribution was used to determine mixing homogeneity of low flow (1.4 mL/minute) dye infusion into pulsatile flow (280-300 mL/minute) of a flui...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198807000-00007
更新日期:1988-07-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:We investigated whether it is possible to investigate degenerative changes in human tissue on a sub-100-microm resolution scale not only on special high-field small-bore MR-microscopy systems but also on a 3T whole-body MR-scanner. METHODS:Spin-spin relaxation, proton density, and diffusion mi...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/01.RLI.0000068620.17569.83
更新日期:2003-07-01 00:00:00
abstract::Human gallstones were surgically placed into the gallbladders of 200 swine. Eight of these swine were used as a prospective series to verify that the placement and presence of human gallstones in their gallbladders caused no significant pathologic changes in the gallbladder and that the gallstones were not spontaneous...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198902000-00005
更新日期:1989-02-01 00:00:00
abstract::Analysis of 46 sacroiliac joints removed in toto at random during routine autopsies was undertaken to define the pathologic and radiographic alterations of this joint in middle-aged and elderly patients. Each joint was sectioned, photographed and radiographed and large microscopic slides were prepared. Sacroiliac oste...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-197511000-00008
更新日期:1975-11-01 00:00:00
abstract:OBJECTIVE:The objective of this study was to evaluate a high spatial resolution 3-dimensional (3D) contrast-enhanced magnetic resonance (CE-MR) venography protocol for evaluation of intracranial venous system using highly accelerated parallel imaging at 3.0 T. MATERIALS AND METHODS:Ten patients (4 male, 6 female; age,...
journal_title:Investigative radiology
pub_type: 临床试验,杂志文章
doi:10.1097/01.rli.0000236992.21065.04
更新日期:2006-10-01 00:00:00
abstract::Dense cavitary "photopenia" was observed on 21 of 200 consecutive stress perfusion scintigrams. A prominent finding in many cases, it sometimes occupied only a portion of the region overlying the ventricular cavity, was often seen in some projections and not others, and was frequently adjacent to myocardial perfusion ...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198507000-00009
更新日期:1985-07-01 00:00:00
abstract:RATIONALE AND OBJECTIVE:The purpose of this study was to investigate the feasibility, efficacy, and safety of ultrasound-guided percutaneous cryotherapy of stage T1 breast cancers. MATERIALS AND METHODS:Thirty patients with biopsy-confirmed breast cancers with tumor diameters of 15 mm or smaller (range, 5-15 mm; media...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/01.rli.0000166935.56971.ff
更新日期:2005-07-01 00:00:00
abstract:OBJECTIVE:We sought to evaluate the influence of tube voltage on the visualization of acute myocardial infarction (MI) in cardiac multislice spiral computed tomography (MSCT). MATERIALS AND METHODS:Acute MI was induced in 12 domestic pigs by a 45-minute balloon occlusion of the left anterior descending artery. Delayed...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/01.rli.0000251577.68223.84
更新日期:2007-02-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:To investigate postmortem metabolic and morphologic alterations in the dog brain thalamus and to contribute diagnostic aids in medicolegal science. METHODS:A homogeneous group of 17 dogs was used for in vivo 1H magnetic resonance (MR) spectroscopy and electron microscopic studies, which were p...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199505000-00001
更新日期:1995-05-01 00:00:00
abstract:OBJECTIVES:To prospectively evaluate the image quality and diagnostic accuracy of magnetic resonance cholangiopancreatography (MRCP) at 3.0 T compared with that at 1.5 T used for patients. MATERIALS AND METHODS:This study was approved by our institutional review board, and informed consent was obtained from all patien...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0b013e3181b4c0ae
更新日期:2009-09-01 00:00:00
abstract:OBJECTIVE:The purpose of this study was to assess the ability of a flow-sensitive alternating inversion recovery-arterial spin labeling (FAIR-ASL) technique to track renal perfusion changes during pharmacologic and physiologic alterations in renal blood flow using microspheres as a gold standard. MATERIALS AND METHODS...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0b013e3181f5e101
更新日期:2011-02-01 00:00:00
abstract:OBJECTIVES:Multidetector-row computed tomography coronary images are usually analyzed in mid-diastole (MD). Because of slow coronary motion also in end-systole (ES), we evaluated the impact on image quality of including ES images and defined an efficient reconstruction protocol. MATERIAL AND METHODS:In 50 coronary mul...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/01.rli.0000153930.34439.e4
更新日期:2005-03-01 00:00:00
abstract:OBJECTIVES:The aim of this study was to investigate the impact of impaired renal function on gadolinium (Gd) retention in various organs after Gd-based contrast agent injection. MATERIALS AND METHODS:After local animal care and review committee approval, 23 normal mice and 26 with renal failure were divided into 4 tre...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0000000000000295
更新日期:2016-10-01 00:00:00
abstract:OBJECTIVES:Dynamic contrast-enhanced imaging allows assessing functional information in addition to morphology using various modalities. Several applications have been established in clinical practice; however, there is no standard with respect to injection protocols or postprocessing algorithms. The purpose of this st...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0b013e318250a72c
更新日期:2012-08-01 00:00:00
abstract:PURPOSE:The aim of this study was to investigate if a quantitative evaluation of a magnetic resonance (MR) perfusion examination of the myocardium can achieve a comparable diagnostic accuracy as a semiquantitative evaluation. METHODS:A total of 31 patients with suspected coronary artery disease underwent MR imaging an...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0b013e31824f54cb
更新日期:2012-06-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:Optimal dose schedules and total dose of ionizing radiation for human central nervous system malignancy are not known. An animal model has been developed for the investigation of rat central nervous system response to proton irradiation using magnetic resonance imaging (MRI). A clinical MRI dev...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199504000-00003
更新日期:1995-04-01 00:00:00
abstract::The importance of evaluating medical student performance has been widely addressed in the medical education literature. Multiple-choice examinations are the preferred method of testing because they are easy to administer and score. Development of parallel or equivalent pre- and post-examinations provides objective inf...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:
更新日期:1986-09-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:The vasoconstriction of the renal arteries is frequently considered as a crucial factor for radiocontrast-induced nephropathy. A direct effect of iodinated radiographic contrast medium (RCM) on vascular smooth muscle is supposed to be one component of the vascular response. We studied the effec...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-200208000-00005
更新日期:2002-08-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:The objective is to assess the diagnostic accuracy and interobserver variability of multiphase 3D gadolinium-enhanced magnetic resonance angiography (3D-Gd-MRA) for assessment of abdominal and pelvic vascular disease. METHODS:In 41 patients from two different institutions multiphase 3D-Gd-MRA ...
journal_title:Investigative radiology
pub_type: 杂志文章,多中心研究
doi:10.1097/00004424-200201000-00005
更新日期:2002-01-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:To develop a computer-assisted analysis of complex joint motion based on standard fluoroscopic sequences. MATERIALS AND METHODS:Fluoroscopic sequences of 10 normal shoulders and 20 patients after total shoulder arthroplasty were recorded during abduction and adduction. The analysis of the shou...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-200202000-00004
更新日期:2002-02-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:The object of this study was to determine by flow cytometry the cellular and DNA content of the washings of core biopsy samples and needles obtained during stereotactic core biopsies of clinically occult suspicious lesions. METHODS:Fourteen-gauge core multipass biopsy inner-needle saline washi...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199801000-00008
更新日期:1998-01-01 00:00:00
abstract::Magnetic resonance (MR) methods have been used to study the metabolic and vascular response of model tumors to tumor necrosis factor (TNF). Magnetic resonance measurements demonstrated acute reductions in tumor blood flow, measured from tumor uptake of D2O, and in tumor adenosine triphosphate (ATP), measured by 31P ma...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198912000-00022
更新日期:1989-12-01 00:00:00
abstract::The issue of dechelation (transmetallation) in vivo after administration of the linear gadolinium-based contrast agents, and potential safety concerns, is considered on the basis of an extensive, focused literature review. Early indications of potential problems included the high level of excess ligand used in the for...
journal_title:Investigative radiology
pub_type: 杂志文章,评审
doi:10.1097/RLI.0000000000000507
更新日期:2018-10-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:To evaluate the imaging characteristics of various iliac artery stents and stent-grafts in a multislice, computed tomography angiography (MSCTA) phantom study. METHODS:Twelve types of stents and three stent-grafts made of different materials (steel, nitinol, tantalum, cobalt-based alloy) were ...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-200112000-00004
更新日期:2001-12-01 00:00:00
abstract:OBJECTIVE:To investigate the efficacy of true fast imaging with steady state precession (true-FISP) compared with T2-weighted fast spin echo (T2W-FSE) in monitoring changes in cyst volume and renal expansion in an ischemia reperfusion (IR) injured PKD1 knockout (IKO) mouse model. MATERIALS AND METHODS:The animal study...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0b013e3181be3501
更新日期:2010-01-01 00:00:00
abstract:PURPOSE:The aim of this study was to compare qualitative and quantitative image quality and geometric distortion of 4 magnetic resonance diffusion-weighted imaging (DWI) sequences of the prostate using comparable imaging parameters and similar acquisition times. METHODS AND MATERIALS:Axial T2-weighted turbo spin echo ...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0000000000000429
更新日期:2018-04-01 00:00:00
abstract::Various water soluble contrast media (WSCM) were injected subcutaneously into 970 hind feet of 485 rats. Gross morphologic changes were seen after the injection and analyzed as a function of various physicochemical characteristics of WSCM. The WSCM of larger volume, higher osmolality, higher iodine content, and meglum...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199006000-00011
更新日期:1990-06-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:The objective of the present study was to compare the data regarding the ability of real-time myocardial contrast echocardiography (MCE) to assess altered myocardial blood flow produced by graded coronary stenoses between open- and closed-chest canine models. MATERIALS AND METHODS:Three grades...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-200301000-00006
更新日期:2003-01-01 00:00:00
abstract:PURPOSE:To prospectively determine the accuracy of 1.5 Tesla (T) and 3 T magnetic resonance angiography (MRA) versus digital subtraction angiography (DSA) in the depiction of infrageniculate arteries in patients with symptomatic peripheral arterial disease. PATIENTS AND METHODS:A prospective 1.5 T, 3 T MRA, and DSA co...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/01.rli.0000262581.52315.ef
更新日期:2007-06-01 00:00:00
abstract:INTRODUCTION:Attenuation correction for magnetic resonance (MR) coils is a new challenge that came about with the development of combined MR and positron emission tomography (PET) imaging. This task is difficult because such coils are not directly visible on either PET or MR acquisitions with current combined scanners ...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0b013e3182a530f8
更新日期:2014-02-01 00:00:00