Abstract:
RATIONALE AND OBJECTIVES:To evaluate the imaging characteristics of various iliac artery stents and stent-grafts in a multislice, computed tomography angiography (MSCTA) phantom study. METHODS:Twelve types of stents and three stent-grafts made of different materials (steel, nitinol, tantalum, cobalt-based alloy) were implanted in plastic tubes with an 8-mm inner diameter filled with iodinated contrast medium diluted to 200 HU. To evaluate the influence of scan parameters on artifacts, the Palmaz stent (as one example) was scanned with a four-slice scanner (Siemens VolumeZoom) with different detector collimations and pitches. All other stents were examined with a collimation of 4 x 1 mm and a table feed of 4 mm/rotation. Axial images and multiplanar reformations were evaluated regarding artifact size, lumen visibility, and intraluminal attenuation values. RESULTS:Higher pitch values caused more pronounced artifacts. Image quality and delineation of the stent struts improved with thinner detector collimation. The size of the stent-related artifacts and the visibility of the stent lumen depended on the underlying stent material and design. Pronounced artifacts, resulting in an insufficient delineation of the stent lumen, were caused by the Strecker tantalum stent and the Zenith stent. Moderate artifacts were caused by the Wallgraft, Passager, Palmaz P 395 and P 424, Bridge, Perflex, and ZA stents. Some artificial lumen narrowing but good lumen delineation was seen with the Strecker nitinol, Symphony, Memotherm, SMART, Corinthian, and Wallstent stents. CONCLUSIONS:Scanning parameters, stent material, and stent design influence lumen assessability and image quality in MSCTA. Detailed lumen assessment is impossible in the Strecker tantalum and Zenith stents and limited in the Wallgraft, Passager, Palmaz P 395 and PS 424, Bridge, Perflex, and ZA-stent stent-grafts but feasible in all other examined products.
journal_name
Invest Radioljournal_title
Investigative radiologyauthors
Maintz D,Fischbach R,Juergens KU,Allkemper T,Wessling J,Heindel Wdoi
10.1097/00004424-200112000-00004keywords:
subject
Has Abstractpub_date
2001-12-01 00:00:00pages
699-704issue
12eissn
0020-9996issn
1536-0210journal_volume
36pub_type
杂志文章abstract:OBJECTIVE:The aim of this study was to evaluate the potential of iterative metal artifact reduction (IMAR) for the improvement of computed tomography (CT)-based position emission tomography (PET) attenuation correction in the vicinity of metal implants and compare it with dual-energy-based metal artifact reduction stra...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0000000000000306
更新日期:2017-01-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:The vasoconstriction of the renal arteries is frequently considered as a crucial factor for radiocontrast-induced nephropathy. A direct effect of iodinated radiographic contrast medium (RCM) on vascular smooth muscle is supposed to be one component of the vascular response. We studied the effec...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-200208000-00005
更新日期:2002-08-01 00:00:00
abstract:OBJECTIVES:Imaging of the kidney using blood oxygen level dependent MR presents a major opportunity to examine differences in tissue oxygenation within the cortex and medulla applicable to human disease. We sought to define the differences between regions within kidneys and to optimize selection of regions of interest ...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0b013e3181b4c1e8
更新日期:2009-09-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:Magnetic resonance imaging (MRI) techniques seem to be very promising for 3D dosimetry studies, but long imaging acquisition time limits their use. A new fast T1 mapping protocol, easy to implement on a conventional MR imager, has been used to determine dose distributions on Fricke gels. METHO...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199903000-00014
更新日期:1999-03-01 00:00:00
abstract:AIM:: We sought to improve the clinical interpretation of first-pass myocardial magnetic resonance perfusion. Parametric analyses of the myocardial distribution of the contrast agent have been proposed. The objective of the present study was to compare the effectiveness of visual analysis and of a parametric approach i...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/01.rli.0000197980.89673.4b
更新日期:2006-04-01 00:00:00
abstract::Video dilution technique (VDT) is currently performed in conjunction with routine cerebral angiography to determine carotid blood flow in humans. Preliminary results indicate that the blood flows (as a percentage of cardial output) of the common, internal, and external carotid arteries are 8.5%, 5.5%, and 3.0%, respec...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198105000-00004
更新日期:1981-05-01 00:00:00
abstract:OBJECTIVE:The aim of this study was to optimize computed tomography (CT) surveillance of skeletal metastases in patients with breast cancer through the use of osseous subtraction maps between baseline and follow-up examinations created by a novel software algorithm. The new postprocessing algorithm segments the origina...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0000000000000343
更新日期:2017-02-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:To investigate the capacity of manganese dipyridoxyl diphosphate (MnDPDP)-enhanced magnetic resonance imaging (MRI) to discriminate the injured myocardium from the normal myocardium in a cat model. MATERIALS AND METHODS:Fourteen cats were prepared for acute myocardial infarction with 90-minute...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:
更新日期:2005-01-01 00:00:00
abstract:OBJECTIVE:Hydration is widely accepted as an effective measure to prevent contrast media (CM)-induced acute kidney injury (AKI). Whether bicarbonate (NaHCO₃) infusion has a greater effect than saline is disputed. Effective prevention of CM-induced AKI by NaHCO₃ has been found by several clinical trials. However, others...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0b013e31822311a9
更新日期:2011-11-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:Density of trabecular bone structures in human heel bones was assessed by 3D magnetic resonance (MR) gradient echo imaging (GEI) with multiple echoes. Different spatial resolutions were applied to investigate the influence of the pixel size on signal characteristics in GEI and to find suitable ...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-200007000-00001
更新日期:2000-07-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:The authors conduct technical feasibility and performance studies on a new 0.009-inch nitinol microguidewire for potential neuroendovascular applications. METHODS:In vivo microcatheterizations of brachiocephalic arteries were performed in four pigs using the 0.009-inch nitinol microguidewire w...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199704000-00008
更新日期:1997-04-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:Interstitial laser photocoagulation (ILP) causes localized tissue necrosis. This study was performed to determine 1) whether the changes seen on computed tomography (CT) correspond to the necrosis pathologically, and 2) which CT technique best shows the necrosis. METHODS:Eighteen Wistar rats h...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199312000-00014
更新日期:1993-12-01 00:00:00
abstract::Patients with intracranial arteriovenous malformations (AVM) can expect significant mortality (15% to 20%) and morbidity (20% to 30%) over a 15-year to 20-year period. Recent advances in interventional neuroradiology, neurosurgery, neuroanesthesia, and stereotactic radiotherapy provide the opportunity to obliterate ma...
journal_title:Investigative radiology
pub_type: 杂志文章,评审
doi:10.1097/00004424-199008000-00014
更新日期:1990-08-01 00:00:00
abstract:OBJECTIVES:To prospectively evaluate accuracy of biliary anatomy depiction and quality of biliary tract visualization of magnetic resonance cholangiography (MRC) at 3.0 T in living potential liver donors (LPLDs). MATERIALS AND METHODS:Our institutional review board approved this study and did not require patient's inf...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0b013e31817e9b52
更新日期:2008-08-01 00:00:00
abstract:PURPOSE:Magnetic Resonance Imaging (MRI) has become the method of choice in the evaluation of patients with suspected cervical artery dissection (CAD). However, reliable identification of acute CAD might be impaired by the limited spatial resolution of standard 1.5 T MRI. In this preliminary study, we implemented a mul...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/01.rli.0000195836.57778.1f
更新日期:2006-02-01 00:00:00
abstract::Early detection of pancreatic ductal adenocarcinoma (PDAC) represents the most significant step toward the treatment of this aggressive lethal disease. Previously, we engineered a preclinical Thy1-targeted microbubble (MBThy1) contrast agent that specifically recognizes Thy1 antigen overexpressed in the vasculature of...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0000000000000697
更新日期:2020-11-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:The authors detect activation in the auditory cortex during cochlear electrical stimulation in deaf patients using functional magnetic resonance (MR) imaging. METHODS:Stimulating electrode was inserted gently under local anesthesia close to the round window membrane of the cochlea in seven coc...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199705000-00007
更新日期:1997-05-01 00:00:00
abstract::A silicone gel phantom material is described. It can be molded into any shape and it can contain internal cavities. The material is selfsealing allowing the cavities to be filled with liquids. A simple geometric phantom consisting of a rectangular solid with a single internal spherical cavity was fabricated and imaged...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198702000-00013
更新日期:1987-02-01 00:00:00
abstract:OBJECTIVES:The objective of this study was to evaluate the use of dielectric pads for improving high spatial resolution imaging of the inner ear at 7 T. MATERIALS AND METHODS:Two sets of dielectric pads were designed using electromagnetic simulations and implemented using a deuterated suspension of barium titanate. Th...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0000000000000026
更新日期:2014-05-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:To evaluate the feasibility of mechanical thrombectomy in occluded hemodialysis access shunts by using a newly developed 5F pigtail rotation catheter. METHODS:Thrombosed hemodialysis access shunts were simulated by clotted bovine blood in silicone tubing (diameter 6 mm). After retrograde and a...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199907000-00008
更新日期:1999-07-01 00:00:00
abstract:OBJECTIVES:The aim of this study was to perform phantom measurements to prove the feasibility of single-source dual-energy computed tomography (DECT) of the extremities using a volume scan mode. In addition, we, for the first time, wanted to determine which concentrations of monosodium urate (MSU) in gout and calcium p...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0000000000000099
更新日期:2015-04-01 00:00:00
abstract:OBJECTIVES:The aim of this study was to compare a compressed-sensing free-breathing VIBE (fbVIBE) with a conventional breath-hold VIBE (bhVIBE) for dynamic contrast-enhanced imaging of the upper abdomen. MATERIALS AND METHODS:In total, 70 datasets (bhVIBE, n = 30; fbVIBE n = 40; hard-gated [hg] reconstruction, n = 30;...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0000000000000607
更新日期:2019-11-01 00:00:00
abstract:OBJECTIVE:Commercially available iodinated contrast media (CM) show significantly different physico-chemical properties. The relevance of the viscosity of CM may be underestimated as a contributing factor for clinically relevant renal failure as suggested by a large registry data analysis (Swedish registry study). The ...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0b013e318190fbd2
更新日期:2009-02-01 00:00:00
abstract:OBJECTIVES:The aim of this pilot study was to assess post-treatment apparent diffusion coefficient (ADC) changes of diffuse large B-cell lymphoma lesions on respiratory-gated whole-body diffusion-weighted imaging (DWI), with integrated (18)F-fluoro-2-deoxyglucose positron emission tomography/computed tomography (PET/CT...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0b013e3182087b03
更新日期:2011-05-01 00:00:00
abstract:OBJECTIVES:The purpose of this study was to develop and validate a computer-aided diagnosis (CAD) tool for automatic classification of pulmonary nodules seen on low-dose computed tomography into solid, part-solid, and non-solid. MATERIALS AND METHODS:Study lesions were randomly selected from 2 sites participating in t...
journal_title:Investigative radiology
pub_type: 临床试验,杂志文章,多中心研究,随机对照试验
doi:10.1097/RLI.0000000000000121
更新日期:2015-03-01 00:00:00
abstract::In order to measure the accuracy of a diagnostic imaging technique, the correctness of each observer decision must be determined. This is often difficult in clinical cases, and various strategies are frequently used to approximate the truth. Experiments using chest radiographs as an example are reported to show the pi...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198303000-00018
更新日期:1983-03-01 00:00:00
abstract::We investigated the feasibility of using intravascular ultrasound imaging to analyze vascular physiology in various arterial beds. Canine superficial femoral, external iliac, and common carotid arteries were harvested and suspended and perfused in a bath of oxygenated, heated, physiologic salt solution. A 6-Fr, 20-MHz...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199103000-00010
更新日期:1991-03-01 00:00:00
abstract:OBJECTIVES:The aim of this study was to investigate the feasibility of nonenhanced magnetic resonance angiography (MRA) of the lower extremities at 7 tesla (T). MATERIALS AND METHODS:Eight healthy volunteers were examined on a 7-T whole-body magnetic resonance system. For image acquisition, a custom-built 16-channel t...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0b013e3182839c2b
更新日期:2013-07-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:To develop a new animal model for the evaluation of the renal tolerance of contrast agent and its application to diatrizoate and iotrolan injections in comparison to saline and mannitol solution. MATERIALS AND METHODS:The nephrotoxic potential of intravenously injected contrast agents in Beagl...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/01.rli.0000087096.61127.13
更新日期:2003-11-01 00:00:00
abstract:PURPOSE:To evaluate the dependency of tumor contrast enhancement (CE) in regard to protein-binding properties of contrast agents, using 4 different agents with a wide range of protein-binding capacities in a standardized rat brain glioma model. MATERIAL AND METHODS:Sixteen rats with implanted brain gliomas were evalua...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0b013e318191a334
更新日期:2009-02-01 00:00:00