Nonionic contrast media iohexol and iomeprol decrease renal arterial tone: comparative studies on human and porcine isolated vascular segments.

Abstract:

RATIONALE AND OBJECTIVES:The vasoconstriction of the renal arteries is frequently considered as a crucial factor for radiocontrast-induced nephropathy. A direct effect of iodinated radiographic contrast medium (RCM) on vascular smooth muscle is supposed to be one component of the vascular response. We studied the effect of the nonionic RCM iomeprol and iohexol on the tonus of isolated human and porcine renal arteries in vitro. METHODS:In an organ bath renal arterial rings, uncontracted or precontracted by 10 micromol/L phenylephrine were incubated with increasing concentrations (15-103 mg iodine/mL) of iohexol, iomeprol, and mannitol solution isoosmolar to the contrast media. In a part of the preparations the endothelium was destroyed. Human vessels were obtained from tumor nephrectomy specimens of 10 patients. RESULTS:In human experiments iomeprol and iohexol (P < 0.05) relaxed renal arterial rings whereas mannitol produced concentration-dependent contractions. The relaxation by both contrast media was slightly attenuated upon increasing their concentration. The differences between mannitol solutions and RCM were statistically significant (P < 0.001) at concentrations of 57 mg iodine/mL and higher. Precontracted rings were significantly stronger relaxed by the RCM compared with mannitol (P < 0.001). The contrast medium induced relaxation did not depend on the presence of an intact endothelium (P > 0.05). Experiments with renal arterial segments prepared from swine showed similar results, with stronger relaxations than the human preparations. CONCLUSION:Iomeprol and iohexol relaxed isolated renal arterial segments. These observations are in contradiction with the hypothesis that contrast media induce nephropathy by a direct vasoconstrictive effect on vascular smooth muscle. They do not exclude, however, a reduction of renal blood flow by other factors like liberation of hormones.

journal_name

Invest Radiol

journal_title

Investigative radiology

authors

Uder M,Humke U,Pahl M,Jansen A,Utz J,Kramann B

doi

10.1097/00004424-200208000-00005

keywords:

subject

Has Abstract

pub_date

2002-08-01 00:00:00

pages

440-7

issue

8

eissn

0020-9996

issn

1536-0210

journal_volume

37

pub_type

杂志文章
  • Systematic evaluation and increased structure in a radiology elective.

    abstract::Diagnostic radiology is expanding, playing an increasingly central role in patient care, which heightens the importance of radiology teaching in undergraduate medical education. This study examined the impact of increased structure and systematic evaluation on student performance in a radiology elective. The evaluatio...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198505000-00003

    authors: Blane CE,Calhoun JG,Maxim BR,Martel W,Davis WK

    更新日期:1985-05-01 00:00:00

  • Black-blood diffusion-weighted EPI acquisition of the liver with parallel imaging: comparison with a standard T2-weighted sequence for detection of focal liver lesions.

    abstract:OBJECTIVES:To evaluate the performance of black-blood diffusion-weighted (DW)-EPI sequences with parallel imaging for the detection of focal liver lesions in comparison with a standard T2-weighted (T2-w) sequence. MATERIALS AND METHODS:Twenty patients with known or suspected focal liver lesions underwent liver MRI usi...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e31816200b5

    authors: Zech CJ,Herrmann KA,Dietrich O,Horger W,Reiser MF,Schoenberg SO

    更新日期:2008-04-01 00:00:00

  • Development of a macromolecular dual-modality MR-optical imaging for sentinel lymph node mapping.

    abstract:OBJECTIVE:To evaluate the effectiveness of a dual magnetic resonance-near infrared fluorescence optical imaging agent, poly(l-glutamic acid)-DTPA-Gd-NIR813, for both preoperative and intraoperative visualization and characterization of sentinel lymph nodes (SLN) in mice. MATERIALS AND METHODS:Poly(L-glutamic acid) was...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e31804f5a79

    authors: Melancon MP,Wang Y,Wen X,Bankson JA,Stephens LC,Jasser S,Gelovani JG,Myers JN,Li C

    更新日期:2007-08-01 00:00:00

  • Direct video-microscopic observation of the dynamic effects of medical ultrasound on ultrasound contrast microspheres.

    abstract:RATIONALE AND OBJECTIVES:Ultrasound can cause destruction of microbubble contrast agents used to enhance medical ultrasound imaging. This study sought to characterize the dynamics of this interaction by direct visual observation of microbubbles during insonification in vitro by a medical ultrasound imaging system. MET...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199812000-00004

    authors: Klibanov AL,Ferrara KW,Hughes MS,Wible JH Jr,Wojdyla JK,Dayton PA,Morgan KE,Brandenburger GH

    更新日期:1998-12-01 00:00:00

  • Potential of dose reduction after marker placement with full-field digital mammography.

    abstract:OBJECTIVES:The purpose of our study was to assess the potential for radiation dose reduction in digital postinterventional digital mammograms after marker placement. MATERIALS AND METHODS:One hundred consecutive cases of marker placement (hook-wire localization or postbiopsy clip marker placement), with 200 full-field...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/01.rli.0000163743.63063.9f

    authors: Riedl CC,Jaromi S,Floery D,Pfarl G,Fuchsjaeger MH,Helbich TH

    更新日期:2005-06-01 00:00:00

  • Comparison of 1.5 and 3 T BOLD MR to study oxygenation of kidney cortex and medulla in human renovascular disease.

    abstract:OBJECTIVES:Imaging of the kidney using blood oxygen level dependent MR presents a major opportunity to examine differences in tissue oxygenation within the cortex and medulla applicable to human disease. We sought to define the differences between regions within kidneys and to optimize selection of regions of interest ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e3181b4c1e8

    authors: Gloviczki ML,Glockner J,Gomez SI,Romero JC,Lerman LO,McKusick M,Textor SC

    更新日期:2009-09-01 00:00:00

  • Magnetic resonance imaging of acute myocardial infarction using a nitroxyl spin label (PCA).

    abstract::The effects of an intravenously administered nitroxyl spin label (PCA) on the magnetic resonance imaging (MRI) appearance and relaxation times of acute canine myocardial infarctions were studied. Twenty-four hours after ligation of the left anterior descending coronary artery (LAD), animals were either sacrificed imme...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:

    authors: McNamara MT,Wesbey GE,Brasch RC,Sievers R,Lipton MJ,Higgins CB

    更新日期:1985-09-01 00:00:00

  • Multislice CT angiography of the iliac arteries in the presence of various stents: in vitro evaluation of artifacts and lumen visibility.

    abstract:RATIONALE AND OBJECTIVES:To evaluate the imaging characteristics of various iliac artery stents and stent-grafts in a multislice, computed tomography angiography (MSCTA) phantom study. METHODS:Twelve types of stents and three stent-grafts made of different materials (steel, nitinol, tantalum, cobalt-based alloy) were ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-200112000-00004

    authors: Maintz D,Fischbach R,Juergens KU,Allkemper T,Wessling J,Heindel W

    更新日期:2001-12-01 00:00:00

  • Investigation of 125I as an isotopic source for mammography.

    abstract::An isotopic radiation source 125I was investigated for use in soft tissue radiaography, with particular attention to possible use in mammography for mass screening. Film sensitivities, exposure rates, absorbed doeses, contrast and resolution were determined, and compared to conventional x-ray units. It was found that ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-197509000-00007

    authors: Fairchild R,Atkins HL,Lebowitz E,Greenberg D

    更新日期:1975-09-01 00:00:00

  • Fluorinated blood substitute retention in the rat measured by fluorine-19 magnetic resonance imaging.

    abstract:RATIONALE AND OBJECTIVES:Emulsions of perfluorocarbons (PFCs) have been tested as blood substitutes. However, evidence exists that there is long-term retention of some PFCs by the organs of the reticuloendothelial system (RES). The authors investigate organ retention of the blood substitute component, perfluorotripropy...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199208000-00012

    authors: Meyer KL,Carvlin MJ,Mukherji B,Sloviter HA,Joseph PM

    更新日期:1992-08-01 00:00:00

  • Comparative transmetallation kinetics and thermodynamic stability of gadolinium-DTPA bis-glucosamide and other magnetic resonance imaging contrast media.

    abstract:RATIONALE AND OBJECTIVES:The relative stability and selectivity of magnetic resonance (MR) imaging contrast agents were compared with in vitro transmetallation and ligand competition reactions. MATERIALS AND METHODS:A gadolinium (Gd)-DTPA-BIGA, Gd-DTPA-BMA, Gd-DTPA, or Gd-HP-DO3A solution was mixed with an equimolar s...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199610000-00003

    authors: Puttagunta NR,Gibby WA,Puttagunta VL

    更新日期:1996-10-01 00:00:00

  • Solid, part-solid, or non-solid?: classification of pulmonary nodules in low-dose chest computed tomography by a computer-aided diagnosis system.

    abstract:OBJECTIVES:The purpose of this study was to develop and validate a computer-aided diagnosis (CAD) tool for automatic classification of pulmonary nodules seen on low-dose computed tomography into solid, part-solid, and non-solid. MATERIALS AND METHODS:Study lesions were randomly selected from 2 sites participating in t...

    journal_title:Investigative radiology

    pub_type: 临床试验,杂志文章,多中心研究,随机对照试验

    doi:10.1097/RLI.0000000000000121

    authors: Jacobs C,van Rikxoort EM,Scholten ET,de Jong PA,Prokop M,Schaefer-Prokop C,van Ginneken B

    更新日期:2015-03-01 00:00:00

  • Mixing problems of low flow hepatic artery infusion. Improvement with small caliber double lumen balloon catheters.

    abstract::The problem of inhomogeneous mixing encountered during hepatic artery (HA) chemotherapy infusion was assessed and a practical solution examined. A glass model of the human HA distribution was used to determine mixing homogeneity of low flow (1.4 mL/minute) dye infusion into pulsatile flow (280-300 mL/minute) of a flui...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198807000-00007

    authors: Barth KH,Lutz RJ,Kremers PW,Miller DL

    更新日期:1988-07-01 00:00:00

  • Osteosarcoma of the nude rat. A model for experimental magnetic resonance imaging studies of bone tumors.

    abstract::A 144cerium-induced osteosarcoma was transplanted to athymic nude rats (Han:rnu/rnu). Nineteen of the tumor-bearing animals were used to demonstrate the characteristics of the osteosarcoma on magnetic resonance imaging (MRI) in comparison with a group of nine animals that had not received any tumor transplant. The tum...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:

    authors: Witzel JG,Bohndorf K,Prescher A,Adam G

    更新日期:1992-03-01 00:00:00

  • Magnetic resonance imaging in a spinal abscess model. Preliminary report.

    abstract:RATIONAL AND OBJECTIVES:Magnetic resonance (MR) scan technique and lesion detectability were evaluated using a newly developed spinal abscess model in the New Zealand White rabbit. METHODS:To create the lesion, an epidural needle was inserted under fluoroscopic guidance in the lumbar region and advanced to penetrate t...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199804000-00008

    authors: Runge VM,Williams NM,Lee C,Timoney JF

    更新日期:1998-04-01 00:00:00

  • Normal renal blood flow measurement using phase-contrast cine magnetic resonance imaging.

    abstract:RATIONALE AND OBJECTIVES:This study assesses the ability of a cardiac-gated phase-contrast magnetic resonance imaging (MRI) technique to measure renal blood flow (RBF) noninvasively in humans. METHODS:In nine normal volunteers, total RBF in the renal arteries and in the left renal vein was estimated by MRI and correla...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199206000-00012

    authors: Sommer G,Noorbehesht B,Pelc N,Jamison R,Pinevich AJ,Newton L,Myers B

    更新日期:1992-06-01 00:00:00

  • Thirty-two-channel coil 3T magnetic resonance-guided biopsies of prostate tumor suspicious regions identified on multimodality 3T magnetic resonance imaging: technique and feasibility.

    abstract:OBJECTIVES:To test the technique and feasibility of translating tumor suspicious region maps in the prostate, obtained by multimodality, anatomic, and functional 3T magnetic resonance imaging (MRI) data to 32-channel coil, T2-weighted (T2-w), 3T MR images, for directing MR-guided biopsies. Furthermore, to evaluate the ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e31817d0506

    authors: Hambrock T,Fütterer JJ,Huisman HJ,Hulsbergen-vandeKaa C,van Basten JP,van Oort I,Witjes JA,Barentsz JO

    更新日期:2008-10-01 00:00:00

  • In vivo and in vitro evaluation of Gd-DTPA-polylysine as a macromolecular contrast agent for magnetic resonance imaging.

    abstract::Polylysine covalently linked to moieties of gadopentetate (Gd-DTPA), for use as a macromolecular blood pool marker for contrast material-enhanced magnetic resonance imaging (MRI), was characterized by means of physicochemical measurements and pharmacokinetics in rats and rabbits and compared with Gd-DTPA. Gd-DTPA-poly...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199111000-00008

    authors: Schuhmann-Giampieri G,Schmitt-Willich H,Frenzel T,Press WR,Weinmann HJ

    更新日期:1991-11-01 00:00:00

  • Reduction of Metal Artifacts and Improvement in Dose Efficiency Using Photon-Counting Detector Computed Tomography and Tin Filtration.

    abstract:OBJECTIVES:The aim of this study was to investigate the impact on metal artifacts and dose efficiency of using a tin filter in combination with high-energy threshold (TH) images of a photon-counting detector (PCD) computed tomography (CT) system. MATERIALS AND METHODS:A 3D-printed spine with pedicle screws was scanned...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000535

    authors: Zhou W,Bartlett DJ,Diehn FE,Glazebrook KN,Kotsenas AL,Carter RE,Fletcher JG,McCollough CH,Leng S

    更新日期:2019-04-01 00:00:00

  • Clinical comparison between a currently available single-loop and an investigational dual-channel endorectal receive coil for prostate magnetic resonance imaging: a feasibility study at 1.5 and 3 T.

    abstract:OBJECTIVES:The objectives of this study were to test the feasibility of an investigational dual-channel next-generation endorectal coil (NG-ERC) in vivo, to quantitatively assess signal-to-noise ratio (SNR), and to get an impression of image quality compared with the current clinically available single-loop endorectal ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e3182a56678

    authors: Vos EK,Sambandamurthy S,Kamel M,McKenney R,van Uden MJ,Hoeks CM,Yakar D,Scheenen TW,Fütterer JJ

    更新日期:2014-01-01 00:00:00

  • Pyelovenous and pyelolymphatic backflow during retrograde pyelography in renal vein thrombosis.

    abstract::Pyelovenous and pyelolymphatic backflow have been observed during retrograde pyelography in three patients with renal vein thrombosis. The radiographic patterns of backflow following experimental unilateral renal vein occlusion in rabbits were analyzed and correlated with the clinical findings. Capsular, perihilar, pe...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198101000-00003

    authors: Bidgood WD Jr,Cuttino JT Jr,Clark RL,Volberg FM

    更新日期:1981-01-01 00:00:00

  • Development of echogenic, plasmid-incorporated, tissue-targeted cationic liposomes that can be used for directed gene delivery.

    abstract:RATIONALE AND OBJECTIVES:Echogenic antibody-conjugated anionic liposomes have been developed that allow directed tissue targeting and acoustic enhancement. These are not efficient for gene delivery. A cationic formulation that allows directed gene delivery while retaining acoustic properties may provide more efficient ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-200012000-00007

    authors: Tiukinhoy SD,Mahowald ME,Shively VP,Nagaraj A,Kane BJ,Klegerman ME,MacDonald RC,McPherson DD,Matsumura JS

    更新日期:2000-12-01 00:00:00

  • Digital radiography versus conventional radiography for the detection of a skull fracture under varying exposure parameters.

    abstract:RATIONALE AND OBJECTIVES:The effect of varying exposure parameters on the detectability of a fracture with digital and conventional radiography were examined. METHODS:A macerated fractured skull was imaged by film-screen radiography (FSR) and digital storage phosphor radiography (DR) with various exposure values. Five...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199303000-00010

    authors: Langen HJ,Klein HM,Wein B,Schiwy-Bochat KH,Stargardt A,Günther RW

    更新日期:1993-03-01 00:00:00

  • Noninvasive inductive stent heating: alternative approach to prevent instent restenosis?

    abstract:RATIONALE AND OBJECTIVES:To test noninvasive inductive heating of implanted vascular stents as an alternative approach for reduction or prevention of neointimal hyperplasia. METHODS:Calorimetric pretests were performed to get an orientation on the different parameters of influence for inductive heating of stents. The ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/01.rli.0000117881.42422.72

    authors: Floren MG,Günther RW,Schmitz-Rode T

    更新日期:2004-05-01 00:00:00

  • Computed tomography-pathologic assessment of laser-induced necrosis in rat liver.

    abstract:RATIONALE AND OBJECTIVES:Interstitial laser photocoagulation (ILP) causes localized tissue necrosis. This study was performed to determine 1) whether the changes seen on computed tomography (CT) correspond to the necrosis pathologically, and 2) which CT technique best shows the necrosis. METHODS:Eighteen Wistar rats h...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199312000-00014

    authors: Amin Z,Thurrell W,Spencer GM,Harries SA,Grant WE,Bown SG,Lees WR

    更新日期:1993-12-01 00:00:00

  • Contrast gradient and the detection of lung nodules.

    abstract::The effects of edge gradient and blur on the detection pulmonary nodules were studied, using a test series of 175 artificial nodules on 30 chest films. The nodules were of homogeneous texture, about 1 cm in diameter and had a mean contrast of .12. Six observers viewed the film set, scoring both location and confidence...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-197901000-00004

    authors: Kundel HL,Revesz G,Toto L

    更新日期:1979-01-01 00:00:00

  • A double-blind comparative study of Hexabrix and Renografin-76 in aortography and visceral arteriography.

    abstract::A diatrizoate compound (Renografin-76) and low osmolality Hexabrix were compared in a double-blind study of 50 adults undergoing arteriographic examination. Subjective and objective assessment of pain reaction for each contrast injection rated lower overall for Hexabrix. Discomfort associated with Renografin was great...

    journal_title:Investigative radiology

    pub_type: 临床试验,杂志文章

    doi:10.1097/00004424-198411001-00012

    authors: Barth KH,Mertens MA

    更新日期:1984-11-01 00:00:00

  • Helium3 polarization using spin exchange technique: application to simultaneous pulmonary ventilation/perfusion imaging in small animals.

    abstract:RATIONALE AND OBJECTIVES:To develop a simple and robust helium3 polarization system dedicated to small animal imaging. To demonstrate the potential of helium3 imaging for pulmonary ventilation and perfusion studies. METHODS:A home-built polarization system based on spin-exchange technique was used. This system was app...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:

    authors: Stupar V,Berthezène Y,Canet E,Tournier H,Dupuich D,Crémillieux Y

    更新日期:2003-06-01 00:00:00

  • Intravascular ultrasound imaging of vascular responsiveness in isolated perfused canine arteries.

    abstract::We investigated the feasibility of using intravascular ultrasound imaging to analyze vascular physiology in various arterial beds. Canine superficial femoral, external iliac, and common carotid arteries were harvested and suspended and perfused in a bath of oxygenated, heated, physiologic salt solution. A 6-Fr, 20-MHz...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199103000-00010

    authors: Wilson MW,Webb RC,Marx MV,Meyer CR,Gallagher MA,Haarer SL,Buda AJ,Williams DM

    更新日期:1991-03-01 00:00:00

  • Contrast-enhanced magnetic resonance angiography of the renal arteries. Original investigation.

    abstract:RATIONALE AND OBJECTIVES:The authors determine the value of contrast-enhanced, three-dimensional (3D) magnetic resonance angiography (MRA) in the assessment of the renal arteries in comparison with conventional arteriography (CA). METHODS:One hundred three patients (71 m, 32 f) were evaluated with both CA and 3D MRA. ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199809000-00021

    authors: Hany TF,Leung DA,Pfammatter T,Debatin JF

    更新日期:1998-09-01 00:00:00