Osteosarcoma of the nude rat. A model for experimental magnetic resonance imaging studies of bone tumors.

Abstract:

:A 144cerium-induced osteosarcoma was transplanted to athymic nude rats (Han:rnu/rnu). Nineteen of the tumor-bearing animals were used to demonstrate the characteristics of the osteosarcoma on magnetic resonance imaging (MRI) in comparison with a group of nine animals that had not received any tumor transplant. The tumor-free animals showed homogeneous results in the measurements of their lower legs (T1, 800-898 mseconds; T2, 33-45 mseconds). The osteosarcomas of the tumor-bearing rats were clearly demonstrated and delineated from adjacent structures by MRI at tumor volumes between 0.3 and 7.5 cm3. A significant increase in T1 and T2 relaxation times was found, which corresponded to the increase in tumor volume. T1 relaxation times decreased slightly when tumor volumes reached greater than 5 cm3, whereas T2 relaxation times remained constant at tumor volumes greater than 2.5 cm3. Histologic changes in the structure of the tumors, occurring naturally during their growth, were proven by immersion-fixed sections embedded in paraffin and stained with hematoxylin-eosin. The water content of small and large tumors was determined by lyophilization and heat drying. Both histologic changes and differences in water content were reflected in the variations of relaxation times.

journal_name

Invest Radiol

journal_title

Investigative radiology

authors

Witzel JG,Bohndorf K,Prescher A,Adam G

keywords:

subject

Has Abstract

pub_date

1992-03-01 00:00:00

pages

205-10

issue

3

eissn

0020-9996

issn

1536-0210

journal_volume

27

pub_type

杂志文章
  • Magnetic resonance evaluation of regional left ventricular function. Effect of through-plane motion.

    abstract:RATIONALE AND OBJECTIVES:Measurements of segmental contraction of the left ventricle by standard magnetic resonance imaging (MRI) and two-dimensional echocardiography involve the comparison of diastolic and systolic time frames acquired from the same imaging plane in space. As the cone-shaped left ventricle shortens al...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199209000-00004

    authors: Pattynama PM,Doornbos J,Hermans J,van der Wall EE,de Roos A

    更新日期:1992-09-01 00:00:00

  • Low-Dose Characterization of Kidney Stones Using Spectral Detector Computed Tomography: An Ex Vivo Study.

    abstract:OBJECTIVES:The aim of this study was to investigate the feasibility of kidney stone composition analysis using spectral detector computed tomography scanner (SDCT) with normal- and low-dose imaging protocols. METHODS:A total of 154 stones harvested from nephrolithotripsy or nephrolithotomy with a known monocrystalline...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000468

    authors: Große Hokamp N,Salem J,Hesse A,Holz JA,Ritter M,Heidenreich A,Maintz D,Haneder S

    更新日期:2018-08-01 00:00:00

  • Pyelovenous and pyelolymphatic backflow during retrograde pyelography in renal vein thrombosis.

    abstract::Pyelovenous and pyelolymphatic backflow have been observed during retrograde pyelography in three patients with renal vein thrombosis. The radiographic patterns of backflow following experimental unilateral renal vein occlusion in rabbits were analyzed and correlated with the clinical findings. Capsular, perihilar, pe...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198101000-00003

    authors: Bidgood WD Jr,Cuttino JT Jr,Clark RL,Volberg FM

    更新日期:1981-01-01 00:00:00

  • Time course of satisfaction of search.

    abstract::"Satisfaction of search" (SOS) refers to the effect in which a second lesion remains undetected after detection of another lesion on the same radiograph. The objective of this study was to clarify our understanding of SOS by relating it to total time of inspection and time intervals before, between, and after discover...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199107000-00003

    authors: Berbaum KS,Franken EA Jr,Dorfman DD,Rooholamini SA,Coffman CE,Cornell SH,Cragg AH,Galvin JR,Honda H,Kao SC

    更新日期:1991-07-01 00:00:00

  • Dual-source computed tomography: advances of improved temporal resolution in coronary plaque imaging.

    abstract:OBJECTIVES:The aim of this study was to quantify image quality gains of a moving coronary plaque phantom using dual-source computed tomography (DSCT) providing 83 milliseconds temporal resolution in direct comparison to 64 slice single-source multidetector CT (MDCT) with a temporal resolution of 165 milliseconds. MATE...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/01.rli.0000254409.79193.96

    authors: Reimann AJ,Rinck D,Birinci-Aydogan A,Scheuering M,Burgstahler C,Schroeder S,Brodoefel H,Tsiflikas I,Herberts T,Flohr T,Claussen CD,Kopp AF,Heuschmid M

    更新日期:2007-03-01 00:00:00

  • A new class of contrast agents for magnetic resonance imaging based on selective reduction of water-T2 by chemical exchange.

    abstract::Compounds containing mobile protons can act as contrast agents by increasing the value of the term (1/12 - 1/11). The efficiency of this method is markedly pH- and field-dependent. There are many such compounds allowing a choice to be made based on the characteristics of the tissue or organ, magnetic field strength, a...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198809001-00058

    authors: Aime S,Nano R,Grandi M

    更新日期:1988-09-01 00:00:00

  • Dynamic contrast-enhanced ultrasound for assessment of skeletal muscle microcirculation in peripheral arterial disease.

    abstract:OBJECTIVE:: This feasibility study was performed to assess whether dynamic contrast-enhanced ultrasound (CEUS) and transient arterial occlusion are able to detect alterations in the microvascular perfusion and arterial perfusion reserve in patients suffering from peripheral arterial disease (PAD) in comparison with hea...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e3182183a77

    authors: Amarteifio E,Weber MA,Wormsbecher S,Demirel S,Krakowski-Roosen H,Jöres A,Braun S,Delorme S,Böckler D,Kauczor HU,Krix M

    更新日期:2011-08-01 00:00:00

  • Evaluation of radiologist interpretive performance using blinded reads by multiple external readers.

    abstract:OBJECTIVE:To demonstrate a method of assessing radiologic diagnostic agreement utilizing multiple blinded external readers. METHODS:Six body CT studies interpreted by one reader (primary reader) at the host institution were compiled with patient identifiers removed. Brief clinical histories that were available to the ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e3181d2ee97

    authors: Ryan AF,Semelka RC,Molina PL,Yonkers S,Vaidean G

    更新日期:2010-04-01 00:00:00

  • Percutaneous radiofrequency ablation of hepatic colorectal metastases: technique, indications, results, and new promises.

    abstract::Surgical resection is the standard of care for colorectal metastases isolated to the liver. However, only 10-25% of the patients are eligible for resection because of extent and location of the disease in the liver or concurrent medical conditions. Image-guided radiofrequency (RF) ablation is a minimally invasive tech...

    journal_title:Investigative radiology

    pub_type: 杂志文章,评审

    doi:10.1097/00004424-200411000-00007

    authors: Lencioni R,Crocetti L,Cioni D,Della Pina C,Bartolozzi C

    更新日期:2004-11-01 00:00:00

  • Solid, part-solid, or non-solid?: classification of pulmonary nodules in low-dose chest computed tomography by a computer-aided diagnosis system.

    abstract:OBJECTIVES:The purpose of this study was to develop and validate a computer-aided diagnosis (CAD) tool for automatic classification of pulmonary nodules seen on low-dose computed tomography into solid, part-solid, and non-solid. MATERIALS AND METHODS:Study lesions were randomly selected from 2 sites participating in t...

    journal_title:Investigative radiology

    pub_type: 临床试验,杂志文章,多中心研究,随机对照试验

    doi:10.1097/RLI.0000000000000121

    authors: Jacobs C,van Rikxoort EM,Scholten ET,de Jong PA,Prokop M,Schaefer-Prokop C,van Ginneken B

    更新日期:2015-03-01 00:00:00

  • Feasibility of real-time magnetic resonance-guided angioplasty and stenting of renal arteries in vitro and in Swine, using a new polyetheretherketone-based magnetic resonance-compatible guidewire.

    abstract:OBJECTIVES:Demonstrate the usability of a new polyetheretherketone (PEEK)-based MR-compatible guidewire for renal artery catheterization, angioplasty, and stenting under MR-guidance using MR-visible markers, in vitro and in vivo. MATERIAL AND METHODS:The new 0.035'' guidewire with fiber-reinforced PEEK core, a soft ti...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e31819b00f1

    authors: Kos S,Huegli R,Hofmann E,Quick HH,Kuehl H,Aker S,Kaiser GM,Borm PJ,Jacob AL,Bilecen D

    更新日期:2009-04-01 00:00:00

  • Contrast-enhanced MRI of tumors. Comparison of Gd-DTPA and a macromolecular agent.

    abstract::The study aim was to define potential differences and advantages in magnetic resonance (MR) patterns of tumoral contrast enhancement using either a small molecular, extracellular fluid contrast enhancer [Gd-DTPA] or a macromolecular agent [albumin-(Gd-DTPA)20], designed for primary intravascular biodistribution. MR im...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198908000-00007

    authors: Wikström MG,Moseley ME,White DL,Dupon JW,Winkelhake JL,Kopplin J,Brasch RC

    更新日期:1989-08-01 00:00:00

  • Reproducibility, accuracy, and predictors of accuracy for the detection of coronary atherosclerotic plaque composition by computed tomography: an ex vivo comparison to intravascular ultrasound.

    abstract:PURPOSE:To determine the reproducibility, accuracy, and predictors of accuracy of computed tomography (CT) angiography to detect and characterize coronary atherosclerotic plaque as compared with intravascular ultrasound. METHODS:Ten ex vivo human coronary arteries were imaged in a moving phantom by dual-source CT (col...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e3181e0a541

    authors: van der Giessen AG,Toepker MH,Donelly PM,Bamberg F,Schlett CL,Raffle C,Irlbeck T,Lee H,van Walsum T,Maurovich-Horvat P,Gijsen FJ,Wentzel JJ,Hoffmann U

    更新日期:2010-11-01 00:00:00

  • Influence of soft tissue (fat and fat-free mass) on ultrasound bone velocity: an in vivo study.

    abstract:RATIONALE AND OBJECTIVES:The authors determine the relative effect of soft-tissue compartments, body fat (percent [%Bfat] and weight [Bfat kg]) and fat-free mass (FFM kg), on measurements of ultrasound bone velocity (UBV m/second). METHODS:The authors measured UBV in proximal phalanxes and body fat and fat-free mass b...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199710000-00005

    authors: Gómez M,Aguado F,Manuel J,Menéndez JM,Revilla M,Villa LF,Cortés J,Rico H

    更新日期:1997-10-01 00:00:00

  • Diatrizoate contrast agents: 2-amino-5-acetamido-, and 3,5-diamino-2,4,6-triiodobenzoates.

    abstract::We have examined the metabolic behavior of several triiodobenzoic acid derivatives because of the observed mutagenicity and cytotoxicity of 3-amino-5-acetamido-2,4,6-triiodobenzoate (I) and 3,5-diamino-2,4,6-triiodobenzoate (II). Measurements were facilitated using iodine-131 (131I)-labeled compounds. Drug retention i...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:

    authors: Weiss R,Hsu B,Wheeler L,Norman A,Riley RF

    更新日期:1981-11-01 00:00:00

  • Reduction of Metal Artifacts and Improvement in Dose Efficiency Using Photon-Counting Detector Computed Tomography and Tin Filtration.

    abstract:OBJECTIVES:The aim of this study was to investigate the impact on metal artifacts and dose efficiency of using a tin filter in combination with high-energy threshold (TH) images of a photon-counting detector (PCD) computed tomography (CT) system. MATERIALS AND METHODS:A 3D-printed spine with pedicle screws was scanned...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000535

    authors: Zhou W,Bartlett DJ,Diehn FE,Glazebrook KN,Kotsenas AL,Carter RE,Fletcher JG,McCollough CH,Leng S

    更新日期:2019-04-01 00:00:00

  • Phantom testing of peripheral artery. Absolute blood flow measurement with digital arteriography.

    abstract::A technique to measure absolute arterial blood flow in ml/min has been developed utilizing software programs with high-speed digital recording for the off-line analysis of intra-arterial injections of contrast medium. Measurements of pulsatile flow in a phantom for a physical flow model showed that calculations with t...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198503000-00017

    authors: Forbes G,Gray JE,Felmlee JP

    更新日期:1985-03-01 00:00:00

  • Multiphase magnetic resonance angiography of the abdominal and pelvic arteries: results of a bicenter multireader analysis.

    abstract:RATIONALE AND OBJECTIVES:The objective is to assess the diagnostic accuracy and interobserver variability of multiphase 3D gadolinium-enhanced magnetic resonance angiography (3D-Gd-MRA) for assessment of abdominal and pelvic vascular disease. METHODS:In 41 patients from two different institutions multiphase 3D-Gd-MRA ...

    journal_title:Investigative radiology

    pub_type: 杂志文章,多中心研究

    doi:10.1097/00004424-200201000-00005

    authors: Schoenberg SO,Essig M,Hallscheidt P,Sharafuddin MJ,Stolpen AH,Knopp MV,Yuh WT

    更新日期:2002-01-01 00:00:00

  • Right-Angled Traction Bronchiectasis in Differentiating Idiopathic Pulmonary Fibrosis Without Honeycombing From Idiopathic Nonspecific Interstitial Pneumonia.

    abstract:OBJECTIVES:The aim of this study was to conduct a radiopathologic evaluation of right-angled traction bronchiectasis to differentiate idiopathic pulmonary fibrosis (IPF) without honeycombing from idiopathic nonspecific interstitial pneumonia (NSIP). MATERIALS AND METHODS:The derivation cohort included 78 consecutive p...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000651

    authors: Kim H,Yoon SH,Lee HJ,Song SG,Koh J,Jeon YK,Chae KJ,Jin GY,Jin KN,Lee KY,Goo JM

    更新日期:2020-06-01 00:00:00

  • Evaluation of Gd-EOB-DTPA uptake in a perfused and isolated mouse liver model: correlation between magnetic resonance imaging and monochromatic quantitative computed tomography.

    abstract:OBJECTIVES:The aim of this work was to quantitatively evaluate the pharmacokinetic pattern of Gd-EOB-DTPA in a model of isolated and perfused mouse liver by using magnetic resonance imaging (MRI) and monochromatic quantitative computed tomography (MQCT). MATERIALS AND METHODS:For MQCT, perfusions were realized with th...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/01.rli.0000174474.43772.58

    authors: Segers J,Le Duc G,Laumonier C,Troprès I,Elst LV,Muller RN

    更新日期:2005-09-01 00:00:00

  • High resolution sonography of the menisci of the knee.

    abstract::High-resolution real-time ultrasonography (5, 7.5, and 10 MHz) was used to examine the menisci of the knee in ten normal volunteers and in ten patients with knee injuries. The posterior horns of the medial and lateral menisci were easily demonstrated. Normal anatomy and pathologic changes could be imaged in the menisc...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198604000-00008

    authors: Selby B,Richardson ML,Montana MA,Teitz CC,Larson RV,Mack LA

    更新日期:1986-04-01 00:00:00

  • The effect of computed tomographic scan orientation on information loss in the three-dimensional reconstruction of tripod zygomatic fractures.

    abstract::Fractures modeled in the dried skull indicate that the initial plane of computed tomography (CT) section contributes to the accuracy of three-dimensional (3D) images generated from two-dimensional (2D) CT data. The authors retrospectively analyzed seven clinical cases of tripod zygomatic fractures that were imaged wit...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199105000-00009

    authors: Levy RA,Kellman RM,Rosenbaum AE

    更新日期:1991-05-01 00:00:00

  • Structured Reporting of Rectal Magnetic Resonance Imaging in Suspected Primary Rectal Cancer: Potential Benefits for Surgical Planning and Interdisciplinary Communication.

    abstract:OBJECTIVES:The aim of this study was to evaluate the effect of structured reports (SRs) in comparison to nonstructured, free-text (FT) rectal magnetic resonance imaging (MRI) reports in patients with histologically proven rectal cancer and potential effects of both types of reporting on referring surgeons' satisfaction...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000336

    authors: Nörenberg D,Sommer WH,Thasler W,DʼHaese J,Rentsch M,Kolben T,Schreyer A,Rist C,Reiser M,Armbruster M

    更新日期:2017-04-01 00:00:00

  • Clinical safety and diagnostic value of the gadolinium chelate gadoterate meglumine (Gd-DOTA).

    abstract:OBJECTIVE:The purpose of this study was to assess the diagnostic value and safety of the contrast agent gadoterate meglumine (Gd-DOTA, DOTAREM, Guerbet, Roissy CdG Cedex, France) in the setting of a postmarketing surveillance study. MATERIALS AND METHODS:Between January 2004 and October 2005, radiologists in 61 radiol...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/01.rli.0000248893.01067.e5

    authors: Herborn CU,Honold E,Wolf M,Kemper J,Kinner S,Adam G,Barkhausen J

    更新日期:2007-01-01 00:00:00

  • Comparison of left ventricular ejection fraction and regional contractility fraction pre and post coronary angiography.

    abstract::Thirty patients [four normals, eight with mild and 18 with severe coronary artery disease (CAD)] were studied to evaluate left ventricular function type and post coronary angiography. The end diastolic volume (EDV), end systolic volume (ESV), ejection fraction (EF) and the regional contractility fractions (RCF) of eig...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-197603000-00009

    authors: Sos TA,Baltaxe HA

    更新日期:1976-03-01 00:00:00

  • Detection of emphysema with computed tomography. Correlation with pulmonary function tests and chest radiography.

    abstract::We studied 60 male patients who had concurrent chest films (CXR), computed tomography scans (CT) and pulmonary function tests (PFT) to assess the sensitivity of CT and conventional films in detecting emphysema compared with PFT. We also sought to determine whether emphysema could be diagnosed by CT in patients with no...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198804000-00004

    authors: Sanders C,Nath PH,Bailey WC

    更新日期:1988-04-01 00:00:00

  • Attenuation correction for flexible magnetic resonance coils in combined magnetic resonance/positron emission tomography imaging.

    abstract:INTRODUCTION:Attenuation correction for magnetic resonance (MR) coils is a new challenge that came about with the development of combined MR and positron emission tomography (PET) imaging. This task is difficult because such coils are not directly visible on either PET or MR acquisitions with current combined scanners ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e3182a530f8

    authors: Eldib M,Bini J,Calcagno C,Robson PM,Mani V,Fayad ZA

    更新日期:2014-02-01 00:00:00

  • Comparison of vascular opacification after bolus injection of iodixanol-320 iohexol-350.

    abstract:RATIONALE AND OBJECTIVES:The vascular opacification characteristics of a new nonionic, dimeric contrast agent, iodixanol, have been compared with a nonionic, monomeric agent, iohexol, using ultrafast computed tomography (UFCT). METHODS:In 10 experiments with mongrel dogs, the contrast agents were alternately injected ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199212000-00011

    authors: Gould R,Brasch RC,Sievers R,Baxter A,Aicher K

    更新日期:1992-12-01 00:00:00

  • Image mottle in abdominal CT.

    abstract:RATIONALE AND OBJECTIVES:To investigate image mottle in conventional CT images of the abdomen as a function of radiographic technique factors and patient size. METHODS:Water-filled phantoms simulating the abdomens of adult (32 cm in diameter) and pediatric (16 cm in diameter) patients were used to investigate image mo...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199904000-00005

    authors: Ende JF,Huda W,Ros PR,Litwiller AL

    更新日期:1999-04-01 00:00:00

  • A method for the study of regional ischemic dysfunction in the intact dog. Permanent endocardial markers and the pressure-length loop.

    abstract::A radiographic method for use in the closed-chest dog is described which allows the quantitation of segmental mechanical performance. Previous work has shown that the area of the pressure-length loop (an approximation of a stress-strain integral) is a useful measure of the mechanical work performed by a segment of myo...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-197611000-00010

    authors: Ringertz HG,Carlsson E,Tyberg JV

    更新日期:1976-11-01 00:00:00