Structured Reporting of Rectal Magnetic Resonance Imaging in Suspected Primary Rectal Cancer: Potential Benefits for Surgical Planning and Interdisciplinary Communication.

Abstract:

OBJECTIVES:The aim of this study was to evaluate the effect of structured reports (SRs) in comparison to nonstructured, free-text (FT) rectal magnetic resonance imaging (MRI) reports in patients with histologically proven rectal cancer and potential effects of both types of reporting on referring surgeons' satisfaction, interdisciplinary communication, and further clinical decision making. MATERIALS AND METHODS:The institutional review board approved this retrospective study with waiver of informed consent. Forty-nine patients with histologically proven rectal cancer were included in this study. All patients underwent rectal MRI for local rectal cancer staging before surgery. Free-text reports and SRs for local MR staging of rectal cancer were generated for all subjects by radiologists. Two experienced abdominal surgeons evaluated a questionnaire that included 9 questions regarding satisfaction with content, presence of reported key features, effort for information extraction, and report quality. RESULTS:Structured reports achieved significantly higher satisfaction rates with report content and clarity, and included significantly more of the 13 predefined key features compared with FT reports (SRs: mean ± SD, 12.2 ± 4.6 [range, 9-13] versus FT reports: mean ± SD, 9.2 ± 10.8 [range, 5-13]) (P < 0.001). Definite further clinical decision making (surgery vs neoadjuvant radiochemotherapy) was possible in 96% of SRs and only in 60% of FT reports (P < 0.001). In case of surgery, the reported information was considered to be sufficient for surgical planning in 94% of SRs versus only 38% in FT reports (P < 0.001). Structured report received a significantly higher overall report quality rated on a Likert scale from 1 to 6 (1, insufficient; 6, excellent) with a mean of 5.8 ± 0.42 (range, 5-6) in comparison to FT reports with 3.6 ± 1.19 (range, 1-5) (P < 0.001). CONCLUSIONS:Structured reporting of rectal MRI in patients with rectal cancer facilitates surgical planning and leads to a higher satisfaction level of referring surgeons in comparison to FT reports. Abdominal surgeons were more confident about report correctness and further clinical decision making on the basis of SRs.

journal_name

Invest Radiol

journal_title

Investigative radiology

authors

Nörenberg D,Sommer WH,Thasler W,DʼHaese J,Rentsch M,Kolben T,Schreyer A,Rist C,Reiser M,Armbruster M

doi

10.1097/RLI.0000000000000336

subject

Has Abstract

pub_date

2017-04-01 00:00:00

pages

232-239

issue

4

eissn

0020-9996

issn

1536-0210

journal_volume

52

pub_type

杂志文章
  • The effect of verification on the assessment of imaging techniques.

    abstract::In order to measure the accuracy of a diagnostic imaging technique, the correctness of each observer decision must be determined. This is often difficult in clinical cases, and various strategies are frequently used to approximate the truth. Experiments using chest radiographs as an example are reported to show the pi...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198303000-00018

    authors: Revesz G,Kundel HL,Bonitatibus M

    更新日期:1983-03-01 00:00:00

  • Effect of additional cations on the twitching reaction to intracarotid, nonionic contrast media in rabbits.

    abstract::Previous investigations in this laboratory have confirmed the observation of facial muscle twitching during intracarotid injections of nonionic contrast media (CM) in rabbits. The reaction appears to be a locally mediated effect. To further investigate this reaction, cortical electroencephalogram (EEG) and facial elec...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199009000-00010

    authors: Whisson CC,Evill CA,Sage MR,Wilson AJ

    更新日期:1990-09-01 00:00:00

  • Minimal spinal hyperostosis with low-dose isotretinoin therapy.

    abstract::Skeletal abnormalities have been reported on numerous occasions in patients who have received high doses of vitamin A and its derivatives. Recently, a new derivative, isotretinoin (Accutane, Hoffman-LaRoche, Inc.), has become available for the treatment of cystic acne. Ninety-six patients treated for a minimum of four...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198601000-00007

    authors: Kilcoyne RF,Cope R,Cunningham W,Nardella FA,Denman S,Franz TJ,Hanifin J

    更新日期:1986-01-01 00:00:00

  • Application of a Novel Iterative Denoising and Image Enhancement Technique in T1-Weighted Precontrast and Postcontrast Gradient Echo Imaging of the Abdomen: Improvement of Image Quality and Diagnostic Confidence.

    abstract:OBJECTIVES:The aim of this study was to investigate the impact of a novel iterative denoising and image enhancement technique in T1-weighted precontrast and postcontrast volume-interpolated breath-hold examination (VIBE) of the abdomen on image quality, noise levels, and diagnostic confidence without change of acquisit...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000746

    authors: Gassenmaier S,Afat S,Nickel D,Kannengiesser S,Herrmann J,Hoffmann R,Othman AE

    更新日期:2020-11-18 00:00:00

  • Three-dimensional cerebral contrast-enhanced magnetic resonance venography at 3.0 Tesla: initial results using highly accelerated parallel acquisition.

    abstract:OBJECTIVE:The objective of this study was to evaluate a high spatial resolution 3-dimensional (3D) contrast-enhanced magnetic resonance (CE-MR) venography protocol for evaluation of intracranial venous system using highly accelerated parallel imaging at 3.0 T. MATERIALS AND METHODS:Ten patients (4 male, 6 female; age,...

    journal_title:Investigative radiology

    pub_type: 临床试验,杂志文章

    doi:10.1097/01.rli.0000236992.21065.04

    authors: Nael K,Fenchel M,Salamon N,Duckwiler GR,Laub G,Finn JP,Villablanca JP

    更新日期:2006-10-01 00:00:00

  • Clinical and High-Resolution CT Features of the COVID-19 Infection: Comparison of the Initial and Follow-up Changes.

    abstract:OBJECTIVES:In late December 2019, an outbreak of coronavirus disease (COVID-19) in Wuhan, China was caused by a novel coronavirus, newly named severe acute respiratory syndrome coronavirus 2. We aimed to quantify the severity of COVID-19 infection on high-resolution chest computed tomography (CT) and to determine its r...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000674

    authors: Xiong Y,Sun D,Liu Y,Fan Y,Zhao L,Li X,Zhu W

    更新日期:2020-06-01 00:00:00

  • Magnetic resonance imaging in a spinal abscess model. Preliminary report.

    abstract:RATIONAL AND OBJECTIVES:Magnetic resonance (MR) scan technique and lesion detectability were evaluated using a newly developed spinal abscess model in the New Zealand White rabbit. METHODS:To create the lesion, an epidural needle was inserted under fluoroscopic guidance in the lumbar region and advanced to penetrate t...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199804000-00008

    authors: Runge VM,Williams NM,Lee C,Timoney JF

    更新日期:1998-04-01 00:00:00

  • Potential of dose reduction after marker placement with full-field digital mammography.

    abstract:OBJECTIVES:The purpose of our study was to assess the potential for radiation dose reduction in digital postinterventional digital mammograms after marker placement. MATERIALS AND METHODS:One hundred consecutive cases of marker placement (hook-wire localization or postbiopsy clip marker placement), with 200 full-field...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/01.rli.0000163743.63063.9f

    authors: Riedl CC,Jaromi S,Floery D,Pfarl G,Fuchsjaeger MH,Helbich TH

    更新日期:2005-06-01 00:00:00

  • Incompatibility of water-soluble contrast media and intravascular pharmacologic agents. An in vitro study.

    abstract::In vitro incompatibilities between nine water-soluble contrast media and 21 intravascular pharmacologic agents were investigated using naked-eye observation and a centrifuge. Most of the previously reported incompatibilities were verified, and a few new incompatibilities were discovered: phentolamine mesylate with dia...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199201000-00008

    authors: Kim SH,Lee HK,Han MC

    更新日期:1992-01-01 00:00:00

  • A large animal model (swine) to study the diagnosis and treatment of cholelithiasis.

    abstract::Human gallstones were surgically placed into the gallbladders of 200 swine. Eight of these swine were used as a prospective series to verify that the placement and presence of human gallstones in their gallbladders caused no significant pathologic changes in the gallbladder and that the gallstones were not spontaneous...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198902000-00005

    authors: Griffith SL,Burney BT,Fry FJ,Franklin TD Jr

    更新日期:1989-02-01 00:00:00

  • Magnetic resonance evaluation of regional left ventricular function. Effect of through-plane motion.

    abstract:RATIONALE AND OBJECTIVES:Measurements of segmental contraction of the left ventricle by standard magnetic resonance imaging (MRI) and two-dimensional echocardiography involve the comparison of diastolic and systolic time frames acquired from the same imaging plane in space. As the cone-shaped left ventricle shortens al...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199209000-00004

    authors: Pattynama PM,Doornbos J,Hermans J,van der Wall EE,de Roos A

    更新日期:1992-09-01 00:00:00

  • Extravascular extravasation of radiographic contrast media. Effects of conventional and low-osmolar agents in the rat thigh.

    abstract::We compared the damage resulting from intradermal injection of four commonly used radiographic contrast media in laboratory rats. Sixty percent meglumine diatrizoate (Reno M 60) and ioxaglate (Hexabrix) produced significantly more ulceration and crusting on gross inspection and more necrosis, edema, and hemorrhage on ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199005000-00006

    authors: Cohan RH,Leder RA,Bolick D,Herzberg AJ,Hedlund LW,Wheeler CT,Helms MJ,Dunnick NR

    更新日期:1990-05-01 00:00:00

  • Evaluation of the prostate imaging reporting and data system for the detection of prostate cancer by the results of targeted biopsy of the prostate.

    abstract:PURPOSE:The purpose of this study was to evaluate the magnetic resonance prostate imaging reporting and data system (PI-RADS) for the detection of prostate cancer by the results of magnetic resonance imaging (MRI)-guided biopsy of the prostate as a reference standard. PATIENTS AND METHODS:In 55 patients who had underg...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000030

    authors: Baur AD,Maxeiner A,Franiel T,Kilic E,Huppertz A,Schwenke C,Hamm B,Durmus T

    更新日期:2014-06-01 00:00:00

  • Ultrasound analysis of tongue, hyoid, and larynx activity during swallowing.

    abstract::Using real-time ultrasound, the motions of the tongue, hyoid bone, and larynx were monitored and timed during swallowing in ten normal subjects. A well-defined propulsive wave of the tongue was observed during swallowing a 5-cc water bolus. The body of the hyoid bone was identified on the ultrasound scan as a high ech...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198403000-00003

    authors: Shawker TH,Sonies B,Hall TE,Baum BF

    更新日期:1984-03-01 00:00:00

  • Adenosine-stress dynamic myocardial CT perfusion imaging: initial clinical experience.

    abstract:OBJECTIVE:To evaluate the feasibility of adenosine-stress dynamic myocardial volume perfusion imaging with second generation dual source computed tomography (CT) for the qualitative and quantitative assessment of myocardial blood flow (MBF) compared with stress perfusion and viability magnetic resonance imaging (MRI). ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e3181dfa2f2

    authors: Bastarrika G,Ramos-Duran L,Rosenblum MA,Kang DK,Rowe GW,Schoepf UJ

    更新日期:2010-06-01 00:00:00

  • Systolic flow displacement correlates with future ascending aortic growth in patients with bicuspid aortic valves undergoing magnetic resonance surveillance.

    abstract:OBJECTIVES:Altered systolic blood flow in the ascending aorta has been correlated with increased aortic growth in patients with bicuspid aortic valves (BAVs). We used conventional, 2-dimensional (2D) phase contrast magnetic resonance imaging (PC-MRI) to assess the relationship between altered flow and future growth in ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000064

    authors: Burris NS,Sigovan M,Knauer HA,Tseng EE,Saloner D,Hope MD

    更新日期:2014-10-01 00:00:00

  • Targeted-microbubble binding selectively to GPIIb IIIa receptors of platelet thrombi.

    abstract:RATIONALE AND OBJECTIVES:New targeted microbubbles directed to the GPIIb IIIa receptor have been developed. The objective was to determine whether targeting microbubbles to clots would enhance ultrasound imaging. Systematic studies were designed to determine whether in vitro methodology is an acceptable predictor of in...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-200211000-00001

    authors: Schumann PA,Christiansen JP,Quigley RM,McCreery TP,Sweitzer RH,Unger EC,Lindner JR,Matsunaga TO

    更新日期:2002-11-01 00:00:00

  • A silicone gel phantom suitable for multimodality imaging.

    abstract::A silicone gel phantom material is described. It can be molded into any shape and it can contain internal cavities. The material is selfsealing allowing the cavities to be filled with liquids. A simple geometric phantom consisting of a rectangular solid with a single internal spherical cavity was fabricated and imaged...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198702000-00013

    authors: Goldstein DC,Kundel HL,Daube-Witherspoon ME,Thibault LE,Goldstein EJ

    更新日期:1987-02-01 00:00:00

  • Critical Questions Regarding Gadolinium Deposition in the Brain and Body After Injections of the Gadolinium-Based Contrast Agents, Safety, and Clinical Recommendations in Consideration of the EMA's Pharmacovigilance and Risk Assessment Committee Recommend

    abstract::For magnetic resonance, the established class of intravenous contrast media is the gadolinium-based contrast agents. In the 3 decades since initial approval, these have proven in general to be very safe for human administration. However, in 2006, a devastating late adverse reaction to administration of the less stable...

    journal_title:Investigative radiology

    pub_type: 杂志文章,评审

    doi:10.1097/RLI.0000000000000374

    authors: Runge VM

    更新日期:2017-06-01 00:00:00

  • Evaluation of CT time-density curves of lower-limb veins.

    abstract:UNLABELLED:Szapiro D, Ghaye B, Willems V, et al. Evaluation of CT time-density curves of lower-limb veins. Invest Radiol 2001;36:164-169. RATIONALE AND OBJECTIVES:To evaluate time-density curves of the lower-limb veins for optimization of CT venography. METHODS:Fifty patients referred for chest CT were randomized int...

    journal_title:Investigative radiology

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1097/00004424-200103000-00005

    authors: Szapiro D,Ghaye B,Willems V,Zhang L,Albert A,Dondelinger RF

    更新日期:2001-03-01 00:00:00

  • Percutaneous radiofrequency ablation of hepatic colorectal metastases: technique, indications, results, and new promises.

    abstract::Surgical resection is the standard of care for colorectal metastases isolated to the liver. However, only 10-25% of the patients are eligible for resection because of extent and location of the disease in the liver or concurrent medical conditions. Image-guided radiofrequency (RF) ablation is a minimally invasive tech...

    journal_title:Investigative radiology

    pub_type: 杂志文章,评审

    doi:10.1097/00004424-200411000-00007

    authors: Lencioni R,Crocetti L,Cioni D,Della Pina C,Bartolozzi C

    更新日期:2004-11-01 00:00:00

  • Noninvasive estimation of organ weights by postmortem magnetic resonance imaging and multislice computed tomography.

    abstract:OBJECTIVE:Computed tomography (CT) and magnetic resonance imaging (MRI) are introduced as an alternative to traditional autopsy. The purpose of this study was to investigate their accuracy in mass estimation of liver and spleen. METHODS:In 44 cases, the weights of spleen and liver were estimated based on MRI and CT da...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/01.rli.0000221323.38443.8d

    authors: Jackowski C,Thali MJ,Buck U,Aghayev E,Sonnenschein M,Yen K,Dirnhofer R,Vock P

    更新日期:2006-07-01 00:00:00

  • Interventional atrioseptostomy by application of monopolar high-frequency alternating current. In vitro evaluation of a new device.

    abstract:RATIONALE AND OBJECTIVES:The authors evaluate the use of a new device for interventional creation of atrial septal defects (ASD) working with high-frequency alternating current in an in vitro study with porcine atria. METHODS:The device consists of a symmetrical cage of six superelastic monofile wires, including a mic...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199702000-00003

    authors: Grabitz RG,Handt S,Vanopbroeke HJ,Seghaye MC,Franke A,Osypka P,von Bernuth G

    更新日期:1997-02-01 00:00:00

  • The effect of certain variables on the tumor and tissue distribution of tracers: VI. False-carrier effect, Part III, Fe.

    abstract::Previous work has shown that Fe3+, when administered in the proper dose and time sequence, increases the tumor uptake of gallium-67 (67Ga) while decreasing its uptake by normal tissues. The purpose of this series of experiments was to examine further the postulate that the false carrier effect is mediated at the cellu...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198207000-00016

    authors: Stern PH,Halpern SE,Hagan PL,Chen A

    更新日期:1982-07-01 00:00:00

  • A closed-chest pulmonary artery occlusion/reperfusion model in the pig: detection of experimental pulmonary embolism with MR angiography and perfusion MR imaging.

    abstract:RATIONALE AND OBJECTIVES:To establish a pig model suitable for imitating pulmonary emboli to facilitate research in the diagnosis of pulmonary embolism. METHODS:Thirteen animals were anesthetized, mechanically ventilated, and subjected to pulmonary artery catheterization initiated from the right external jugular vein....

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-200005000-00003

    authors: Amundsen T,Kvaerness J,Aadahl P,Waage A,Bjermer L,Odegård A,Haraldseth O

    更新日期:2000-05-01 00:00:00

  • Computed Tomography for 4-Dimensional Angiography and Perfusion Imaging of the Prostate for Embolization Planning of Benign Prostatic Hyperplasia.

    abstract:OBJECTIVES:The aim of this study was to evaluate the feasibility of a computed tomography (CT) protocol enabling the visualization of the prostatic artery (PA) before prostatic artery embolization (PAE) in benign prostatic hyperplasia, which provides quantitative perfusion information of the prostate gland. MATERIALS ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000582

    authors: Kobe A,Puippe G,Klotz E,Alkadhi H,Pfammatter T

    更新日期:2019-10-01 00:00:00

  • 18F-Fluorodeoxyglucose Positron Emission Tomography/Magnetic Resonance in Lymphoma: Comparison With 18F-Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography and With the Addition of Magnetic Resonance Diffusion-Weighted Imaging.

    abstract:OBJECTIVES:The aim of this study was to compare F-fluorodeoxyglucose (FDG) positron emission tomography (PET)/magnetic resonance (MR) (with and without diffusion-weighted imaging [DWI]) to F-FDG PET/computed tomography (CT), with regard to the assessment of nodal and extranodal involvement, in patients with Hodgkin lym...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000218

    authors: Giraudo C,Raderer M,Karanikas G,Weber M,Kiesewetter B,Dolak W,Simonitsch-Klupp I,Mayerhoefer ME

    更新日期:2016-03-01 00:00:00

  • Low-Dose Characterization of Kidney Stones Using Spectral Detector Computed Tomography: An Ex Vivo Study.

    abstract:OBJECTIVES:The aim of this study was to investigate the feasibility of kidney stone composition analysis using spectral detector computed tomography scanner (SDCT) with normal- and low-dose imaging protocols. METHODS:A total of 154 stones harvested from nephrolithotripsy or nephrolithotomy with a known monocrystalline...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000468

    authors: Große Hokamp N,Salem J,Hesse A,Holz JA,Ritter M,Heidenreich A,Maintz D,Haneder S

    更新日期:2018-08-01 00:00:00

  • Dual source dual energy MDCT: comparison of 80 kVp and weighted average 120 kVp data for conspicuity of hypo-vascular liver metastases.

    abstract:PURPOSE:To determine whether liver metastases conspicuity is improved at 80 kVp when compared with weighted average (WA) simulated 120 kVp data using dual source dual energy CT. METHODS:A total of 11 patients with 44 hypo-vascular liver metastases underwent contrast enhanced Dual Energy CT (DECT). In all cases the sub...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e3181dfda78

    authors: Robinson E,Babb J,Chandarana H,Macari M

    更新日期:2010-07-01 00:00:00

  • Magnetic resonance imaging of pulmonary ventilation. Initial experiences with a gadolinium-DTPA-based aerosol.

    abstract:RATIONALE AND OBJECTIVES:The authors investigate whether a modified gadolinium (Gd)-DTPA formulation can be aerosolized and used as a contrast agent for magnetic resonance (MR) ventilation imaging of the lungs. METHODS:Gadolinium-DTPA (gadopentetate dimeglumine, Schering AG, Berlin, Germany, 100 mmol Gd/L) was modifie...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199712000-00010

    authors: Misselwitz B,Mühler A,Heinzelmann I,Böck JC,Weinmann HJ

    更新日期:1997-12-01 00:00:00