Magnetic resonance imaging of pulmonary ventilation. Initial experiences with a gadolinium-DTPA-based aerosol.

Abstract:

RATIONALE AND OBJECTIVES:The authors investigate whether a modified gadolinium (Gd)-DTPA formulation can be aerosolized and used as a contrast agent for magnetic resonance (MR) ventilation imaging of the lungs. METHODS:Gadolinium-DTPA (gadopentetate dimeglumine, Schering AG, Berlin, Germany, 100 mmol Gd/L) was modified by addition of mannitol (Sigma, Deisenhofen, Germany, 10 mg/mL) and the surface active detergent Lutrol F68 (BASF, Mannheim, Germany, 2 mg/mL). The imaging was performed in an anesthetized rat model after inhalation of the contrast agent aerosol (PulmoSonic, De Vilbiss, Germany, 10-minute nebulization). T1-weighted spin echo images (repetitive time [TR]/echo time [TE] = 40/3 mseconds) were acquired at 2 T (SIS 85; Sisco, Fremont, CA) before and as long as 120 minutes after administration of the contrast agent. RESULTS:The modified Gd-DTPA aerosol elicited high and relatively homogeneous enhancement of the lung directly after nebulization. The enhancement was more pronounced than that obtained with a Gd-DTPA formulation without additives. CONCLUSIONS:Gadolinium-DTPA-based aerosol appears to be a suitable contrast agent for MR ventilation imaging in an experimental animal model. Modification by mannitol (to increase proton density through a slight additional osmotic effect) and a detergent (to reduce droplet size by decreasing surface tension) is suitable and effective in increasing signal intensity compared with Gd-DTPA without modification.

journal_name

Invest Radiol

journal_title

Investigative radiology

authors

Misselwitz B,Mühler A,Heinzelmann I,Böck JC,Weinmann HJ

doi

10.1097/00004424-199712000-00010

subject

Has Abstract

pub_date

1997-12-01 00:00:00

pages

797-801

issue

12

eissn

0020-9996

issn

1536-0210

journal_volume

32

pub_type

杂志文章
  • Comparison of gadobenate dimeglumine with gadopentetate dimeglumine for magnetic resonance imaging of liver tumors.

    abstract:RATIONALE AND OBJECTIVES:To compare gadobenate dimeglumine (Gd-BOPTA) with gadopentetate dimeglumine (Gd-DTPA) for magnetic resonance imaging of the liver. METHODS:The contrast agent Gd-BOPTA or Gd-DTPA was administered at a dose of 0.1 mmol/kg to 257 patients suspected of having malignant liver tumors. Dynamic phase ...

    journal_title:Investigative radiology

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1097/00004424-200111000-00002

    authors: Kuwatsuru R,Kadoya M,Ohtomo K,Tanimoto A,Hirohashi S,Murakami T,Tanaka Y,Yoshikawa K,Katayama H

    更新日期:2001-11-01 00:00:00

  • AUR Memorial Award 1993. A drug system (PDH) for interventional radiology. Synthesis, properties, and efficacy.

    abstract:RATIONALE AND OBJECTIVES:The authors synthesized and tested a novel hydrogel system proposed for use in extra- and intravascular radiologic interventions, such as chemoembolizations and embolizations, and as a vehicle for sustained drug release. MATERIALS:The material was specifically designed to meet the prerequisite...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199312000-00001

    authors: Weissleder R,Bogdanov A,Frank H,Nossiff N,Bogdanova A,Schaffer BK,Brady T,Wittenberg J

    更新日期:1993-12-01 00:00:00

  • Screening mammography. A risk versus risk decision.

    abstract::The potential risk of a radiologic procedure often is compared with the potential benefit of the procedure. While risk vs. benefit analysis has been useful as a step toward increased communication and understanding among radiologists, referring physicians, and the general public, it has the disadvantage that risk and ...

    journal_title:Investigative radiology

    pub_type: 杂志文章,评审

    doi:10.1097/00004424-198901000-00005

    authors: Ritenour ER,Hendee WR

    更新日期:1989-01-01 00:00:00

  • Consistency of rotator-cuff calcifications. Observations on plain radiography, sonography, computed tomography, and at needle treatment.

    abstract:RATIONALE AND OBJECTIVES:The author analyzes findings of consistency of rotator-cuff calcifications found at ultrasound (US)-guided needle treatment compared with findings of plain radiography, US, and computed tomography (CT). METHODS:Twenty patients had rotator-cuff calcifications (mean diameter, 1.5 cm; range, 1.1-...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199605000-00010

    authors: Farin PU

    更新日期:1996-05-01 00:00:00

  • Three-dimensional ultrashort echo time imaging of solid polymers on a 3-Tesla whole-body MRI scanner.

    abstract:OBJECTIVE:With the introduction of ultrashort echo time (UTE) sequences solid polymeric materials might become visible on clinical whole-body magnetic resonance (MR) scanners. The aim of this study was to characterize solid polymeric materials typically used for instruments in magnetic resonance guided interventions an...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e318188601f

    authors: Springer F,Martirosian P,Schwenzer NF,Szimtenings M,Kreisler P,Claussen CD,Schick F

    更新日期:2008-11-01 00:00:00

  • Polycystic kidney disease evaluation by magnetic resonance imaging in ischemia-reperfusion injured PKD1 knockout mouse model: comparison of T2-weighted FSE and true-FISP.

    abstract:OBJECTIVE:To investigate the efficacy of true fast imaging with steady state precession (true-FISP) compared with T2-weighted fast spin echo (T2W-FSE) in monitoring changes in cyst volume and renal expansion in an ischemia reperfusion (IR) injured PKD1 knockout (IKO) mouse model. MATERIALS AND METHODS:The animal study...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e3181be3501

    authors: Zhou X,Bao H,Takakura A,Zhou J,Albert M,Sun Y

    更新日期:2010-01-01 00:00:00

  • The detection of inflammation in collapsed lung by alterations in proton nuclear magnetic relaxation times.

    abstract::The purpose of this study was to establish the proton NMR relaxation times of collapsed but otherwise normal lung tissue and to determine whether an inflammatory process within a collapsed lung can be detected by alterations in relaxation times. The lungs of three groups of rabbits were studied: group A (n = 7) had a ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198508000-00004

    authors: Huber DJ,Kobzik L,Melanson G,Adams DF

    更新日期:1985-08-01 00:00:00

  • Microangiographic anatomy of the cat's eye.

    abstract::The microangiographic anatomy of the cat's eye is presented. The characteristic vascular pattern of each of the three distinct circulations, retinal choroidal, and ciliary is described and illustrated. ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-197501000-00007

    authors: Rothman SL,Kier EL,Deuker DK

    更新日期:1975-01-01 00:00:00

  • Experimental nephrotoxicity of the radiocontrast agents iohexol, ioxaglate, and iothalamate. An in vitro and in vivo study.

    abstract::The authors compared the renal toxicity of the low osmolality radiocontrast agents, iohexol and ioxaglate, and the ionic agent, iothalamate, at equivalent iodine dose, using experimental models in vitro and in vivo. In isolated perfused rat kidneys, all agents induced comparable biphasic hemodynamic changes, associate...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199104000-00008

    authors: Brezis M,Greenfeld Z,Herman M,Meyer JJ,Heyman SN,Rosen S

    更新日期:1991-04-01 00:00:00

  • Large-tip-angle spin-echo imaging. Theory and applications.

    abstract:RATIONALE AND OBJECTIVES:Tissue contrast phenomenology was investigated analytically and clinically for a class of magnetic resonance (MR) pulse sequences we call large-tip-angle (LTA) spin-echo (SE) imaging. In comparison to traditional SE sequences (denoted 90 degrees-180 degrees-echo), the LTA sequence is of the for...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199310000-00017

    authors: Elster AD,Provost TJ

    更新日期:1993-10-01 00:00:00

  • Contrast-enhanced magnetic resonance angiography of the carotid arteries: influence of injection rates and volumes on arterial-venous transit time.

    abstract:RATIONALE AND OBJECTIVES:To assess the influence of injection rates and volumes on the arrival time of contrast material (CM) in the common carotid artery, the jugular vein and the resulting arterial-venous transit time. Additionally the relationship between injection parameters and the extent of a CM plateau was evalu...

    journal_title:Investigative radiology

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1097/01.rli.0000105040.40925.c8

    authors: Herold T,Paetzel C,Völk M,Bachthaler M,Zorger N,Feuerbach S,Strotzer M,Lenhart M

    更新日期:2004-02-01 00:00:00

  • Facilitated Diagnosis of Pneumothoraces in Newborn Mice Using X-ray Dark-Field Radiography.

    abstract:OBJECTIVE:The aim of this study was to evaluate the diagnostic value of x-ray dark-field imaging in projection radiography-based depiction of pneumothoraces in the neonatal murine lung, a potentially life-threatening medical condition that requires a timely and correct diagnosis. MATERIALS AND METHODS:By the use of a ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000285

    authors: Hellbach K,Yaroshenko A,Willer K,Pritzke T,Baumann A,Hesse N,Auweter S,Reiser MF,Eickelberg O,Pfeiffer F,Hilgendorff A,Meinel FG

    更新日期:2016-10-01 00:00:00

  • Temporal changes in the oxidation state in in vitro blood.

    abstract::The rates at which the paramagnetic compounds deoxyhemoglobin (Hb) and methemoglobin (MHb) form in vivo within an area of hemorrhage are unknown. The present experiment establishes the baseline concentrations and rates of change in paramagnetic hemoglobin concentrations, as well as the pH in normal heparinized and clo...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199003000-00006

    authors: Taber KH,Migliore PJ,Pagani JJ,Ford JJ,McLauren T,Hayman LA

    更新日期:1990-03-01 00:00:00

  • Computerized case-based instructional system for computed tomography and magnetic resonance imaging of brain tumors.

    abstract:RATIONALE AND OBJECTIVES:A computerized system that applies the case-based approach to training radiologists to diagnose brain tumors was designed. The authors attempted to provide residents a tool that supports their visual memory and inducts case-based reasoning. METHODS:A relational database with a digital image li...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199404000-00020

    authors: Macura RT,Macura KJ,Toro VE,Binet EF,Trueblood JH,Ji K

    更新日期:1994-04-01 00:00:00

  • Intravascular ultrasound imaging of vascular responsiveness in isolated perfused canine arteries.

    abstract::We investigated the feasibility of using intravascular ultrasound imaging to analyze vascular physiology in various arterial beds. Canine superficial femoral, external iliac, and common carotid arteries were harvested and suspended and perfused in a bath of oxygenated, heated, physiologic salt solution. A 6-Fr, 20-MHz...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199103000-00010

    authors: Wilson MW,Webb RC,Marx MV,Meyer CR,Gallagher MA,Haarer SL,Buda AJ,Williams DM

    更新日期:1991-03-01 00:00:00

  • Magnetic resonance imaging contrast enhancement of brain tumors at 3 tesla versus 1.5 tesla.

    abstract:RATIONALE AND OBJECTIVES:To compare the diagnostic efficacy of a standard dose of MRI contrast agent in the evaluation of primary brain tumors and metastases using a high-field 3 tesla MR unit versus a 1.5 tesla MR unit. METHODS:Sixteen patients with brain tumors were examined at both field strengths using identical a...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-200203000-00003

    authors: Nöbauer-Huhmann IM,Ba-Ssalamah A,Mlynarik V,Barth M,Schöggl A,Heimberger K,Matula C,Fog A,Kaider A,Trattnig S

    更新日期:2002-03-01 00:00:00

  • Fluorinated blood substitute retention in the rat measured by fluorine-19 magnetic resonance imaging.

    abstract:RATIONALE AND OBJECTIVES:Emulsions of perfluorocarbons (PFCs) have been tested as blood substitutes. However, evidence exists that there is long-term retention of some PFCs by the organs of the reticuloendothelial system (RES). The authors investigate organ retention of the blood substitute component, perfluorotripropy...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199208000-00012

    authors: Meyer KL,Carvlin MJ,Mukherji B,Sloviter HA,Joseph PM

    更新日期:1992-08-01 00:00:00

  • Cine phase-contrast magnetic resonance imaging for analysis of flow phenomena in experimental aortic dissection.

    abstract::Using a 1.5 T magnetic resonance imaging (MRI) system, cine phase-contrast and magnitude images were obtained in three phantoms that simulated different anatomic configurations of aortic dissection. The dissection phantoms were made of compliant materials, and pulsatile flow was used in all experiments. Phantoms diffe...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199112000-00007

    authors: Iwai F,Sostman HD,Evans AJ,Nadel SN,Hedlund LW,Beam CA,Charles HC,Spritzer CE

    更新日期:1991-12-01 00:00:00

  • Osteosarcoma of the nude rat. A model for experimental magnetic resonance imaging studies of bone tumors.

    abstract::A 144cerium-induced osteosarcoma was transplanted to athymic nude rats (Han:rnu/rnu). Nineteen of the tumor-bearing animals were used to demonstrate the characteristics of the osteosarcoma on magnetic resonance imaging (MRI) in comparison with a group of nine animals that had not received any tumor transplant. The tum...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:

    authors: Witzel JG,Bohndorf K,Prescher A,Adam G

    更新日期:1992-03-01 00:00:00

  • Comparison of Routine Brain Imaging at 3 T and 7 T.

    abstract:OBJECTIVE:The aim of this study was to compare quantitative and semiquantitative parameters (signal-to-noise ratio [SNR], contrast-to-noise ratio [CNR], image quality, diagnostic confidence) from a standard brain magnetic resonance imaging examination encompassing common neurological disorders such as demyelinating dis...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000256

    authors: Springer E,Dymerska B,Cardoso PL,Robinson SD,Weisstanner C,Wiest R,Schmitt B,Trattnig S

    更新日期:2016-08-01 00:00:00

  • Improving CT-Based PET Attenuation Correction in the Vicinity of Metal Implants by an Iterative Metal Artifact Reduction Algorithm of CT Data and Its Comparison to Dual-Energy-Based Strategies: A Phantom Study.

    abstract:OBJECTIVE:The aim of this study was to evaluate the potential of iterative metal artifact reduction (IMAR) for the improvement of computed tomography (CT)-based position emission tomography (PET) attenuation correction in the vicinity of metal implants and compare it with dual-energy-based metal artifact reduction stra...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000306

    authors: Schabel C,Gatidis S,Bongers M,Hüttig F,Bier G,Kupferschlaeger J,Bamberg F,la Fougère C,Nikolaou K,Pfannenberg C

    更新日期:2017-01-01 00:00:00

  • Temperature-Sensitive Frozen-Tissue Imaging for Cryoablation Monitoring Using STIR-UTE MRI.

    abstract:PURPOSE:The aim of this study was to develop a method to delineate the lethally frozen-tissue region (temperature less than -40°C) arising from interventional cryoablation procedures using a short tau inversion-recovery ultrashort echo-time (STIR-UTE) magnetic resonance (MR) imaging sequence. This method could serve as...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000642

    authors: Tokuda J,Wang Q,Tuncali K,Seethamraju RT,Tempany CM,Schmidt EJ

    更新日期:2020-05-01 00:00:00

  • The effect of some iodinated contrast media on human plasma butyrylcholinesterase activity.

    abstract::The effect of three iodinated contrast media (CM) on human plasma butyrylcholinesterase (BuChE) activity was studied during the intravenous pyelography (i.v.P). BuChE is an enzyme that participates in the metabolism of acetylcholine and hydrolyzes food esters and drugs such as nondepolarizing muscle relaxants and loca...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199805000-00008

    authors: Mironidou M,Ximitidou O,Christopoulos S,Kokkas B

    更新日期:1998-05-01 00:00:00

  • Saturation kinetics of iopanoate in dogs with an intact enterohepatic circulation. Before and after phenobarbital induction.

    abstract::Capacity-limited elimination of sodium iopanoate and a reproducible apparent transport maximum (Tm) were demonstrated in nonoperated dogs having an intact enterohepatic circulation and normal endogenous bile salt pool. Using a multiple infusion technique, estimation of apparent Tm of iopanoate in the liver was possibl...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-197601000-00007

    authors: Herzog RJ,Nelson JA,Staubus AE

    更新日期:1976-01-01 00:00:00

  • Digital mammography using iodine-based contrast media: initial clinical experience with dynamic contrast medium enhancement.

    abstract:PURPOSE:We sought to evaluate the potential of dynamic contrast enhancement after the intravenous administration of an iodine-based contrast medium in full-field digital mammography. MATERIAL AND METHODS:A protocol for image acquisition was established for contrast-enhanced mammography and the mammography unit (Senogr...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/01.rli.0000167421.83203.4e

    authors: Diekmann F,Diekmann S,Jeunehomme F,Muller S,Hamm B,Bick U

    更新日期:2005-07-01 00:00:00

  • Dual-Energy Computed Tomography-Based Display of Bone Marrow Edema in Incidental Vertebral Compression Fractures: Diagnostic Accuracy and Characterization in Oncological Patients Undergoing Routine Staging Computed Tomography.

    abstract:PURPOSE:The aim of this study was to evaluate the diagnostic performance of virtual noncalcium (VNCa) dual-energy computed tomography (DECT) reconstructions enabling visualization of bone marrow edema for characterization of incidental thoracolumbar compression fractures in routine thoracoabdominal staging computed tom...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000458

    authors: Frellesen C,Azadegan M,Martin SS,Otani K,DʼAngelo T,Booz C,Eichler K,Panahi B,Kaup M,Bauer RW,Vogl TJ,Wichmann JL

    更新日期:2018-07-01 00:00:00

  • A Standardized Parameter-Free Algorithm for Combined Intravoxel Incoherent Motion and Diffusion Kurtosis Analysis of Diffusion Imaging Data.

    abstract:OBJECTIVES:The aims of this study were to implement and systematically evaluate the performance of a new parameter-free segmented algorithm for analysis of diffusion imaging data using a combined intravoxel incoherent motion and diffusion kurtosis imaging (IVIM-DKI) model of spin diffusion in comparison with the simple...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000223

    authors: Wurnig MC,Kenkel D,Filli L,Boss A

    更新日期:2016-03-01 00:00:00

  • The effects of radiographic contrast media on myocardial contractility and coronary resistance: osmolality, ionic concentration, and viscosity.

    abstract::With the ongoing development of new contrast agents, questions develop concerning the cardiac effects of these drugs. We used the perfused rat heart model to investigate the effects on cardiac and coronary function of hypertonic ionic (sodium chloride) and nonionic (glucose) solutions and conventional and low osmolali...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199003000-00009

    authors: Fleetwood G,Bettmann MA,Gordon JL

    更新日期:1990-03-01 00:00:00

  • Whole-body diffusion-weighted imaging with apparent diffusion coefficient mapping for treatment response assessment in patients with diffuse large B-cell lymphoma: pilot study.

    abstract:OBJECTIVES:The aim of this pilot study was to assess post-treatment apparent diffusion coefficient (ADC) changes of diffuse large B-cell lymphoma lesions on respiratory-gated whole-body diffusion-weighted imaging (DWI), with integrated (18)F-fluoro-2-deoxyglucose positron emission tomography/computed tomography (PET/CT...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e3182087b03

    authors: Lin C,Itti E,Luciani A,Zegai B,Lin SJ,Kuhnowski F,Pigneur F,Gaillard I,Paone G,Meignan M,Haioun C,Rahmouni A

    更新日期:2011-05-01 00:00:00

  • A computer program for the localization of small areas in roentgenological images.

    abstract::A method and associated algorithm are presented which allow a simple and accurate determination to be made of the location of small symmetric areas presented in roentgenological images. The method utilizes an operator to visually spot object positions but eliminates the need for critical positoning accuracy on the ope...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-197603000-00007

    authors: Keller RA,Baily NA